cnvd-2015-00648
Vulnerability from cnvd
Title
Schneider Electric ETG3000 FactoryCast HMI Gateway未授权访问漏洞
Description
Schneider Electric ETG3000 FactoryCast HMI Gateway是基于Web的SCADA系统。
Schneider Electric ETG3000 FactoryCast HMI Gateway存在未授权访问漏洞,允许攻击者利用漏洞获得未经授权的访问,其包含文件的配置细节等敏感信息。
Severity
中
VLAI Severity ?
Patch Name
Schneider Electric ETG3000 FactoryCast HMI Gateway未授权访问漏洞的补丁
Patch Description
Schneider Electric ETG3000 FactoryCast HMI Gateway是基于Web的SCADA系统。
Schneider Electric ETG3000 FactoryCast HMI Gateway存在未授权访问漏洞,允许攻击者利用漏洞获得未经授权的访问,其包含文件的配置细节等敏感信息。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description
用户可联系供应商获得补丁信息: http://www.schneider-electric.com/site/home/index.cfm/ww/?selectCountry=true
Reference
http://www.securityfocus.com/bid/72254
Impacted products
| Name | Schneider Electric ETG3000 FactoryCast HMI Gateway |
|---|
{
"bids": {
"bid": {
"bidNumber": "72254"
}
},
"cves": {
"cve": {
"cveNumber": "CVE-2014-9197"
}
},
"description": "Schneider Electric ETG3000 FactoryCast HMI Gateway\u662f\u57fa\u4e8eWeb\u7684SCADA\u7cfb\u7edf\u3002\r\n\r\nSchneider Electric ETG3000 FactoryCast HMI Gateway\u5b58\u5728\u672a\u6388\u6743\u8bbf\u95ee\u6f0f\u6d1e\uff0c\u5141\u8bb8\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u83b7\u5f97\u672a\u7ecf\u6388\u6743\u7684\u8bbf\u95ee\uff0c\u5176\u5305\u542b\u6587\u4ef6\u7684\u914d\u7f6e\u7ec6\u8282\u7b49\u654f\u611f\u4fe1\u606f\u3002",
"discovererName": "Narendra Shinde of Qualys Security",
"formalWay": "\u7528\u6237\u53ef\u8054\u7cfb\u4f9b\u5e94\u5546\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttp://www.schneider-electric.com/site/home/index.cfm/ww/?selectCountry=true",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2015-00648",
"openTime": "2015-01-27",
"patchDescription": "Schneider Electric ETG3000 FactoryCast HMI Gateway\u662f\u57fa\u4e8eWeb\u7684SCADA\u7cfb\u7edf\u3002\r\nSchneider Electric ETG3000 FactoryCast HMI Gateway\u5b58\u5728\u672a\u6388\u6743\u8bbf\u95ee\u6f0f\u6d1e\uff0c\u5141\u8bb8\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u83b7\u5f97\u672a\u7ecf\u6388\u6743\u7684\u8bbf\u95ee\uff0c\u5176\u5305\u542b\u6587\u4ef6\u7684\u914d\u7f6e\u7ec6\u8282\u7b49\u654f\u611f\u4fe1\u606f\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric ETG3000 FactoryCast HMI Gateway\u672a\u6388\u6743\u8bbf\u95ee\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Schneider Electric ETG3000 FactoryCast HMI Gateway"
},
"referenceLink": "http://www.securityfocus.com/bid/72254",
"serverity": "\u4e2d",
"submitTime": "2015-01-22",
"title": "Schneider Electric ETG3000 FactoryCast HMI Gateway\u672a\u6388\u6743\u8bbf\u95ee\u6f0f\u6d1e"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…