CVE-2025-54496 (GCVE-0-2025-54496)
Vulnerability from cvelistv5
Published
2025-11-04 21:36
Modified
2025-11-04 21:46
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
8.4 (High) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.4 (High) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
A maliciously crafted project file may cause a heap-based buffer
overflow in
Fuji Electric Monitouch V-SFT-6, which may allow the attacker to execute arbitrary code.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Monitouch V-SFT-6 |
Version: 6.2.7.0 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54496",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-04T21:46:28.137824Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-04T21:46:35.254Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Monitouch V-SFT-6",
"vendor": "Fuji Electric",
"versions": [
{
"status": "affected",
"version": "6.2.7.0"
},
{
"status": "unaffected",
"version": "6.2.8.0"
},
{
"status": "unaffected",
"version": "6.2.9.0 or newer."
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Rocco Calvi with TecSecurity working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A maliciously crafted project file may cause a heap-based buffer \noverflow in \nFuji Electric Monitouch V-SFT-6, which may allow the attacker to execute arbitrary code."
}
],
"value": "A maliciously crafted project file may cause a heap-based buffer \noverflow in \nFuji Electric Monitouch V-SFT-6, which may allow the attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-04T21:36:46.018Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://felib.fujielectric.co.jp/en/document_search?tab=software\u0026document1%5B1%5D=M10009\u0026document2%5B1%5D=M20104\u0026product1%5B1%5D=P10003\u0026product2%5B1%5D=P20023\u0026product3%5B1%5D=P30623\u0026product4%5B1%5D=S11133\u0026discontinued%5B1%5D=0\u0026count=20\u0026sort=en_title\u0026page=1\u0026region=en-glb"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-308-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-308-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Fuji Electric has addressed these vulnerabilities in their October release (V-SFT V6.2.8.0). They recommend users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://felib.fujielectric.co.jp/en/document_search?tab=software\u0026amp;document1%5B1%5D=M10009\u0026amp;document2%5B1%5D=M20104\u0026amp;product1%5B1%5D=P10003\u0026amp;product2%5B1%5D=P20023\u0026amp;product3%5B1%5D=P30623\u0026amp;product4%5B1%5D=S11133\u0026amp;discontinued%5B1%5D=0\u0026amp;count=20\u0026amp;sort=en_title\u0026amp;page=1\u0026amp;region=en-glb\"\u003eupdate to V6.2.9.0 or newer.\u003c/a\u003e\n\n\u003cbr\u003e"
}
],
"value": "Fuji Electric has addressed these vulnerabilities in their October release (V-SFT V6.2.8.0). They recommend users update to V6.2.9.0 or newer. https://felib.fujielectric.co.jp/en/document_search"
}
],
"source": {
"advisory": "ICSA-25-308-01",
"discovery": "EXTERNAL"
},
"title": "Fuji Electric Monitouch V-SFT-6 Heap-based Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-54496",
"datePublished": "2025-11-04T21:36:46.018Z",
"dateReserved": "2025-07-30T19:03:10.137Z",
"dateUpdated": "2025-11-04T21:46:35.254Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-54496\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2025-11-04T22:16:28.560\",\"lastModified\":\"2025-11-06T19:45:30.990\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A maliciously crafted project file may cause a heap-based buffer \\noverflow in \\nFuji Electric Monitouch V-SFT-6, which may allow the attacker to execute arbitrary code.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-122\"}]}],\"references\":[{\"url\":\"https://felib.fujielectric.co.jp/en/document_search?tab=software\u0026document1%5B1%5D=M10009\u0026document2%5B1%5D=M20104\u0026product1%5B1%5D=P10003\u0026product2%5B1%5D=P20023\u0026product3%5B1%5D=P30623\u0026product4%5B1%5D=S11133\u0026discontinued%5B1%5D=0\u0026count=20\u0026sort=en_title\u0026page=1\u0026region=en-glb\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-308-01.json\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-25-308-01\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-54496\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-11-04T21:46:28.137824Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-11-04T21:46:31.623Z\"}}], \"cna\": {\"title\": \"Fuji Electric Monitouch V-SFT-6 Heap-based Buffer Overflow\", \"source\": {\"advisory\": \"ICSA-25-308-01\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Rocco Calvi with TecSecurity working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.4, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"ACTIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Fuji Electric\", \"product\": \"Monitouch V-SFT-6\", \"versions\": [{\"status\": \"affected\", \"version\": \"6.2.7.0\"}, {\"status\": \"unaffected\", \"version\": \"6.2.8.0\"}, {\"status\": \"unaffected\", \"version\": \"6.2.9.0 or newer.\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Fuji Electric has addressed these vulnerabilities in their October release (V-SFT V6.2.8.0). They recommend users update to V6.2.9.0 or newer. https://felib.fujielectric.co.jp/en/document_search\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Fuji Electric has addressed these vulnerabilities in their October release (V-SFT V6.2.8.0). They recommend users \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://felib.fujielectric.co.jp/en/document_search?tab=software\u0026amp;document1%5B1%5D=M10009\u0026amp;document2%5B1%5D=M20104\u0026amp;product1%5B1%5D=P10003\u0026amp;product2%5B1%5D=P20023\u0026amp;product3%5B1%5D=P30623\u0026amp;product4%5B1%5D=S11133\u0026amp;discontinued%5B1%5D=0\u0026amp;count=20\u0026amp;sort=en_title\u0026amp;page=1\u0026amp;region=en-glb\\\"\u003eupdate to V6.2.9.0 or newer.\u003c/a\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://felib.fujielectric.co.jp/en/document_search?tab=software\u0026document1%5B1%5D=M10009\u0026document2%5B1%5D=M20104\u0026product1%5B1%5D=P10003\u0026product2%5B1%5D=P20023\u0026product3%5B1%5D=P30623\u0026product4%5B1%5D=S11133\u0026discontinued%5B1%5D=0\u0026count=20\u0026sort=en_title\u0026page=1\u0026region=en-glb\"}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-25-308-01\"}, {\"url\": \"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-308-01.json\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A maliciously crafted project file may cause a heap-based buffer \\noverflow in \\nFuji Electric Monitouch V-SFT-6, which may allow the attacker to execute arbitrary code.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A maliciously crafted project file may cause a heap-based buffer \\noverflow in \\nFuji Electric Monitouch V-SFT-6, which may allow the attacker to execute arbitrary code.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-122\", \"description\": \"CWE-122\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-11-04T21:36:46.018Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-54496\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-11-04T21:46:35.254Z\", \"dateReserved\": \"2025-07-30T19:03:10.137Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2025-11-04T21:36:46.018Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…