CVE-2025-50121 (GCVE-0-2025-50121)
Vulnerability from cvelistv5 – Published: 2025-07-11 09:14 – Updated: 2025-11-03 20:05- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure™ IT Data Center Expert |
Affected:
8.3 , ≤ Prior to
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-50121",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-11T15:09:11.955744Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-11T15:15:05.184Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T20:05:35.286Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/6"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure\u2122 IT Data Center Expert",
"vendor": "Schneider Electric",
"versions": [
{
"lessThanOrEqual": "Prior to",
"status": "affected",
"version": "8.3",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-07-08T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\u0026nbsp;CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\nover the web interface HTTP when enabled. HTTP is disabled by default."
}
],
"value": "A\u00a0CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\nover the web interface HTTP when enabled. HTTP is disabled by default."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.5,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-13T23:28:32.348Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2025-50121",
"datePublished": "2025-07-11T09:14:55.415Z",
"dateReserved": "2025-06-12T13:53:23.602Z",
"dateUpdated": "2025-11-03T20:05:35.286Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-50121\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2025-07-11T10:15:23.120\",\"lastModified\":\"2025-11-03T20:19:11.977\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A\u00a0CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\\nover the web interface HTTP when enabled. HTTP is disabled by default.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad CWE-78: Neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del sistema operativo (\u0027Inyecci\u00f3n de comandos del sistema operativo\u0027) que podr\u00eda causar la ejecuci\u00f3n remota de c\u00f3digo no autenticado al crear una carpeta maliciosa a trav\u00e9s de la interfaz web HTTP cuando est\u00e1 habilitada. HTTP est\u00e1 deshabilitado de forma predeterminada.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.5,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"HIGH\",\"subIntegrityImpact\":\"LOW\",\"subAvailabilityImpact\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"http://seclists.org/fulldisclosure/2025/Jul/6\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"http://seclists.org/fulldisclosure/2025/Jul/6\"}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2025-11-03T20:05:35.286Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-50121\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-11T15:09:11.955744Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-11T15:10:30.543Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"LOW\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"EcoStruxure\\u2122 IT Data Center Expert\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.3\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"Prior to\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-07-08T05:00:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A\\u00a0CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\\nover the web interface HTTP when enabled. HTTP is disabled by default.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A\u0026nbsp;CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\\nover the web interface HTTP when enabled. HTTP is disabled by default.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2025-07-13T23:28:32.348Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-50121\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-11-03T20:05:35.286Z\", \"dateReserved\": \"2025-06-12T13:53:23.602Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2025-07-11T09:14:55.415Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
ICSA-25-203-06
Vulnerability from csaf_cisa - Published: 2025-07-08 04:00 - Updated: 2025-07-08 04:00Notes
{
"document": {
"acknowledgments": [
{
"organization": "Schneider Electric CPCERT",
"summary": "reporting these vulnerabilities to CISA."
},
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc.",
"summary": "reporting these vulnerabilities to Schneider Electric."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure\u2122 IT Data Center Expert (DCE)\r\nproduct. \r\nThe EcoStruxure\u2122 IT Data Center Expert product is a scalable monitoring software that collects, organizes, \r\nand distributes critical device information providing a comprehensive view of equipment. \r\nFailure to apply the remediation provided below may risk information disclosure, and remote compromise of \r\nthe offer which could result in disruption of operations and access to system data.",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 (CVSS v4.0) https://www.first.org/cvss/calculator/4.0 . CVSS v3.1 will be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u0027s environment."
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/contacts.jsp if you need assistance removing a patch. "
},
{
"category": "description",
"text": "EcoStruxure\u2122 IT Data Center Expert is Formerly known as StruxureWare Data Center Expert"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2025-189-01 from a direct conversion of their vendor\u0027s Common Security Advisory Framework (CSAF) advisory. This is republished to CISA\u0027s website as a means of increasing visibility and is provided \"as-is\" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "EcoStruxure\u2122 IT Data Center Expert - SEVD-2025-189-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-189-01.json"
},
{
"category": "self",
"summary": "EcoStruxure\u2122 IT Data Center Expert - SEVD-2025-189-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-189-01.pdf"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-203-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-203-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-25-203-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-203-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric EcoStruxture IT Data Center Expert",
"tracking": {
"current_release_date": "2025-07-08T04:00:00.000000Z",
"generator": {
"date": "2025-07-22T14:29:49.415255Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-25-203-06",
"initial_release_date": "2025-07-08T04:00:00.000000Z",
"revision_history": [
{
"date": "2025-07-08T04:00:00.000000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=8.3",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 IT Data Center Expert Version 8.3 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 IT Data Center Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "9.0",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 IT Data Center Expert Version 9.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 IT Data Center Expert"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50121",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\r\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\r\nover the web interface HTTP when enabled. HTTP is disabled by default.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002"
],
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-50121"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50122",
"cwe": {
"id": "CWE-331",
"name": "Insufficient Entropy"
},
"notes": [
{
"category": "description",
"text": "CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the \r\npassword generation algorithm is reverse engineered with access to installation or upgrade artifacts.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002"
],
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-50122"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50123",
"cwe": {
"id": "CWE-94",
"name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that could cause remote \r\ncommand execution by a privileged account when the server is accessed via a console and through \r\nexploitation of the hostname input.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002"
],
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-50123"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50125",
"cwe": {
"id": "CWE-918",
"name": "Server-Side Request Forgery (SSRF)"
},
"notes": [
{
"category": "description",
"text": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthenticated remote \r\ncode execution when the server is accessed via the network with knowledge of hidden URLs and manipulation \r\nof host request header.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002"
],
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-50125"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50124",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "description",
"text": "CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the \r\nserver is accessed by a privileged account via a console and through exploitation of a setup script.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002"
],
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-50124"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-6438",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "description",
"text": "CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could \r\ncause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access\r\nwhen the server is accessed via the network using an application account.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFPID-0002"
],
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"CSAFPID-0001"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"CSAFPID-0002"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2025-6438"
}
]
}
FKIE_CVE-2025-50121
Vulnerability from fkie_nvd - Published: 2025-07-11 10:15 - Updated: 2025-11-03 20:19| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A\u00a0CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\nover the web interface HTTP when enabled. HTTP is disabled by default."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad CWE-78: Neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del sistema operativo (\u0027Inyecci\u00f3n de comandos del sistema operativo\u0027) que podr\u00eda causar la ejecuci\u00f3n remota de c\u00f3digo no autenticado al crear una carpeta maliciosa a trav\u00e9s de la interfaz web HTTP cuando est\u00e1 habilitada. HTTP est\u00e1 deshabilitado de forma predeterminada."
}
],
"id": "CVE-2025-50121",
"lastModified": "2025-11-03T20:19:11.977",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.5,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2025-07-11T10:15:23.120",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://seclists.org/fulldisclosure/2025/Jul/6"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
CERTFR-2025-AVI-0565
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure | EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module versions antérieures à 2024 pour la vulnérabilité CVE-2025-6788 | ||
| Schneider Electric | EcoStruxure | EcoStruxure IT Data Center Expert versions antérieures ou égales à 8.3 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Monitoring Expert (PME) versions antérieures à 2023 R2 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Operation (EPO) 2022 versions antérieures ou égales à CU6 pour les vulnérabilités CVE-2023-50447, CVE-2024-28219, CVE-2022-45198, CVE-2023-5217, CVE-2023-35945 et CVE-2023-44487. | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module versions antérieures à 2022 pour la vulnérabilité CVE-2025-6788 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Monitoring Expert (PME) versions antérieures à 2023 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Monitoring Expert (PME) versions antérieures à 2024 R2 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Monitoring Expert (PME) versions antérieures à 2024 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Operation (EPO) 2024 versions antérieures ou égales à CU1 pour les vulnérabilités CVE-2023-50447, CVE-2024-28219, CVE-2022-45198, CVE-2023-5217, CVE-2023-35945 et CVE-2023-44487. |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module versions ant\u00e9rieures \u00e0 2024 pour la vuln\u00e9rabilit\u00e9 CVE-2025-6788",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure IT Data Center Expert versions ant\u00e9rieures ou \u00e9gales \u00e0 8.3",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions ant\u00e9rieures \u00e0 2023 R2",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Operation (EPO) 2022 versions ant\u00e9rieures ou \u00e9gales \u00e0 CU6 pour les vuln\u00e9rabilit\u00e9s CVE-2023-50447, CVE-2024-28219, CVE-2022-45198, CVE-2023-5217, CVE-2023-35945 et CVE-2023-44487.",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module versions ant\u00e9rieures \u00e0 2022 pour la vuln\u00e9rabilit\u00e9 CVE-2025-6788",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions ant\u00e9rieures \u00e0 2023",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions ant\u00e9rieures \u00e0 2024 R2",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions ant\u00e9rieures \u00e0 2024",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Operation (EPO) 2024 versions ant\u00e9rieures ou \u00e9gales \u00e0 CU1 pour les vuln\u00e9rabilit\u00e9s CVE-2023-50447, CVE-2024-28219, CVE-2022-45198, CVE-2023-5217, CVE-2023-35945 et CVE-2023-44487.",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2025-50122",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50122"
},
{
"name": "CVE-2023-50447",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-50447"
},
{
"name": "CVE-2023-44487",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44487"
},
{
"name": "CVE-2025-50121",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50121"
},
{
"name": "CVE-2025-50125",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50125"
},
{
"name": "CVE-2024-28219",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-28219"
},
{
"name": "CVE-2022-45198",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45198"
},
{
"name": "CVE-2023-35945",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35945"
},
{
"name": "CVE-2025-6438",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-6438"
},
{
"name": "CVE-2025-6788",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-6788"
},
{
"name": "CVE-2025-50123",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50123"
},
{
"name": "CVE-2023-5217",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-5217"
},
{
"name": "CVE-2025-50124",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50124"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0565",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-07-08T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Falsification de requ\u00eates c\u00f4t\u00e9 serveur (SSRF)"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2025-07-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-189-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
},
{
"published_at": "2025-07-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-189-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-04.pdf"
},
{
"published_at": "2025-07-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-189-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-03.pdf"
}
]
}
CERTFR-2025-AVI-0565
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | EcoStruxure | EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module versions antérieures à 2024 pour la vulnérabilité CVE-2025-6788 | ||
| Schneider Electric | EcoStruxure | EcoStruxure IT Data Center Expert versions antérieures ou égales à 8.3 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Monitoring Expert (PME) versions antérieures à 2023 R2 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Operation (EPO) 2022 versions antérieures ou égales à CU6 pour les vulnérabilités CVE-2023-50447, CVE-2024-28219, CVE-2022-45198, CVE-2023-5217, CVE-2023-35945 et CVE-2023-44487. | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module versions antérieures à 2022 pour la vulnérabilité CVE-2025-6788 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Monitoring Expert (PME) versions antérieures à 2023 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Monitoring Expert (PME) versions antérieures à 2024 R2 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Monitoring Expert (PME) versions antérieures à 2024 | ||
| Schneider Electric | EcoStruxure | EcoStruxure Power Operation (EPO) 2024 versions antérieures ou égales à CU1 pour les vulnérabilités CVE-2023-50447, CVE-2024-28219, CVE-2022-45198, CVE-2023-5217, CVE-2023-35945 et CVE-2023-44487. |
| Title | Publication Time | Tags | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module versions ant\u00e9rieures \u00e0 2024 pour la vuln\u00e9rabilit\u00e9 CVE-2025-6788",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure IT Data Center Expert versions ant\u00e9rieures ou \u00e9gales \u00e0 8.3",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions ant\u00e9rieures \u00e0 2023 R2",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Operation (EPO) 2022 versions ant\u00e9rieures ou \u00e9gales \u00e0 CU6 pour les vuln\u00e9rabilit\u00e9s CVE-2023-50447, CVE-2024-28219, CVE-2022-45198, CVE-2023-5217, CVE-2023-35945 et CVE-2023-44487.",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module versions ant\u00e9rieures \u00e0 2022 pour la vuln\u00e9rabilit\u00e9 CVE-2025-6788",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions ant\u00e9rieures \u00e0 2023",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions ant\u00e9rieures \u00e0 2024 R2",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions ant\u00e9rieures \u00e0 2024",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Operation (EPO) 2024 versions ant\u00e9rieures ou \u00e9gales \u00e0 CU1 pour les vuln\u00e9rabilit\u00e9s CVE-2023-50447, CVE-2024-28219, CVE-2022-45198, CVE-2023-5217, CVE-2023-35945 et CVE-2023-44487.",
"product": {
"name": "EcoStruxure",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2025-50122",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50122"
},
{
"name": "CVE-2023-50447",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-50447"
},
{
"name": "CVE-2023-44487",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44487"
},
{
"name": "CVE-2025-50121",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50121"
},
{
"name": "CVE-2025-50125",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50125"
},
{
"name": "CVE-2024-28219",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-28219"
},
{
"name": "CVE-2022-45198",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45198"
},
{
"name": "CVE-2023-35945",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35945"
},
{
"name": "CVE-2025-6438",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-6438"
},
{
"name": "CVE-2025-6788",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-6788"
},
{
"name": "CVE-2025-50123",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50123"
},
{
"name": "CVE-2023-5217",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-5217"
},
{
"name": "CVE-2025-50124",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-50124"
}
],
"links": [],
"reference": "CERTFR-2025-AVI-0565",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2025-07-08T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "Falsification de requ\u00eates c\u00f4t\u00e9 serveur (SSRF)"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2025-07-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-189-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
},
{
"published_at": "2025-07-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-189-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-04.pdf"
},
{
"published_at": "2025-07-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2025-189-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-03.pdf"
}
]
}
NCSC-2025-0221
Vulnerability from csaf_ncscnl - Published: 2025-07-09 08:38 - Updated: 2025-07-09 08:38Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE"
}
},
"lang": "nl",
"notes": [
{
"category": "legal_disclaimer",
"text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings."
},
{
"category": "description",
"text": "Schneider Electric heeft kwetsbaarheden verholpen in EcoStruxture IT Datacenter Expert.",
"title": "Feiten"
},
{
"category": "description",
"text": "De kwetsbaarheden omvatten onder andere onvoldoende controle over speciale elementen in OS-commando\u0027s, wat kan leiden tot ongeauthenticeerde externe code-executie. Daarnaast is er een probleem met onvoldoende entropie in wachtwoordgeneratie-algoritmen, wat kan resulteren in het ontdekken van rootwachtwoorden. Verder is er een kwetsbaarheid gerelateerd aan onjuiste controle van codegeneratie, wat kan leiden tot externe opdrachtuitvoering via hostname-invoer. Ook is er een Server-Side Request Forgery (SSRF) kwetsbaarheid die ongeauthenticeerde externe code-executie mogelijk maakt door manipulatie van verborgen URL\u0027s. Bovendien is er een probleem met onjuiste privilegebeheer, wat kan leiden tot privilege-escalatie. Tot slot kan er ongeautoriseerde bestandstoegang plaatsvinden door het misbruiken van SOAP API-aanroepen en XML externe entiteiten injectie.",
"title": "Interpretaties"
},
{
"category": "description",
"text": "Schneider Electric heeft updates uitgebracht om de kwetsbaarheden te verhelpen. Zie bijgevoegde referenties voor meer informatie.",
"title": "Oplossingen"
},
{
"category": "general",
"text": "medium",
"title": "Kans"
},
{
"category": "general",
"text": "high",
"title": "Schade"
},
{
"category": "general",
"text": "Insufficient Entropy",
"title": "CWE-331"
},
{
"category": "general",
"text": "Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"title": "CWE-94"
},
{
"category": "general",
"text": "Server-Side Request Forgery (SSRF)",
"title": "CWE-918"
},
{
"category": "general",
"text": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"title": "CWE-78"
},
{
"category": "general",
"text": "Improper Restriction of XML External Entity Reference",
"title": "CWE-611"
},
{
"category": "general",
"text": "Improper Privilege Management",
"title": "CWE-269"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "cert@ncsc.nl",
"name": "Nationaal Cyber Security Centrum",
"namespace": "https://www.ncsc.nl/"
},
"references": [
{
"category": "external",
"summary": "Reference - schneider",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-189-01.pdf"
}
],
"title": "Kwetsbaarheden verholpen in Schneider Electric EcoStruxture IT Datacenter Expert",
"tracking": {
"current_release_date": "2025-07-09T08:38:05.336146Z",
"generator": {
"date": "2025-06-05T14:45:00Z",
"engine": {
"name": "V.A.",
"version": "1.1"
}
},
"id": "NCSC-2025-0221",
"initial_release_date": "2025-07-09T08:38:05.336146Z",
"revision_history": [
{
"date": "2025-07-09T08:38:05.336146Z",
"number": "1.0.0",
"summary": "Initiele versie"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:schneider/\u003c=8.3",
"product": {
"name": "vers:schneider/\u003c=8.3",
"product_id": "CSAFPID-2963461"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 IT Data Center Expert"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-50121",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "other",
"text": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"title": "CWE-78"
}
],
"product_status": {
"known_affected": [
"CSAFPID-2963461"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-50121 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-50121.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-2963461"
]
}
],
"title": "CVE-2025-50121"
},
{
"cve": "CVE-2025-50122",
"cwe": {
"id": "CWE-331",
"name": "Insufficient Entropy"
},
"notes": [
{
"category": "other",
"text": "Insufficient Entropy",
"title": "CWE-331"
}
],
"product_status": {
"known_affected": [
"CSAFPID-2963461"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-50122 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-50122.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-2963461"
]
}
],
"title": "CVE-2025-50122"
},
{
"cve": "CVE-2025-50123",
"cwe": {
"id": "CWE-94",
"name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)"
},
"notes": [
{
"category": "other",
"text": "Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"title": "CWE-94"
}
],
"product_status": {
"known_affected": [
"CSAFPID-2963461"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-50123 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-50123.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-2963461"
]
}
],
"title": "CVE-2025-50123"
},
{
"cve": "CVE-2025-50125",
"cwe": {
"id": "CWE-918",
"name": "Server-Side Request Forgery (SSRF)"
},
"notes": [
{
"category": "other",
"text": "Server-Side Request Forgery (SSRF)",
"title": "CWE-918"
}
],
"product_status": {
"known_affected": [
"CSAFPID-2963461"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-50125 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-50125.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-2963461"
]
}
],
"title": "CVE-2025-50125"
},
{
"cve": "CVE-2025-50124",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "other",
"text": "Improper Privilege Management",
"title": "CWE-269"
}
],
"product_status": {
"known_affected": [
"CSAFPID-2963461"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-50124 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-50124.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-2963461"
]
}
],
"title": "CVE-2025-50124"
},
{
"cve": "CVE-2025-6438",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "other",
"text": "Improper Restriction of XML External Entity Reference",
"title": "CWE-611"
}
],
"product_status": {
"known_affected": [
"CSAFPID-2963461"
]
},
"references": [
{
"category": "self",
"summary": "CVE-2025-6438 | NCSC-NL Website",
"url": "https://vulnerabilities.ncsc.nl/csaf/v2/2025/cve-2025-6438.json"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFPID-2963461"
]
}
],
"title": "CVE-2025-6438"
}
]
}
CVE-2025-50121
Vulnerability from csaf_se - Published: 2025-07-08 04:00 - Updated: 2025-07-08 04:00Notes
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure\u2122 IT Data Center Expert (DCE)\r\nproduct. \r\nThe EcoStruxure\u2122 IT Data Center Expert product is a scalable monitoring software that collects, organizes, \r\nand distributes critical device information providing a comprehensive view of equipment. \r\nFailure to apply the remediation provided below may risk information disclosure, and remote compromise of \r\nthe offer which could result in disruption of operations and access to system data.",
"title": "Overview"
},
{
"category": "other",
"text": "The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 (CVSS v4.0) https://www.first.org/cvss/calculator/4.0 . CVSS v3.1 will be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer\u0027s environment."
},
{
"category": "other",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center https://www.se.com/us/en/work/support/contacts.jsp if you need assistance removing a patch. "
},
{
"category": "description",
"text": "EcoStruxure\u2122 IT Data Center Expert is Formerly known as StruxureWare Data Center Expert"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "EcoStruxure\u2122 IT Data Center Expert - SEVD-2025-189-01 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
},
{
"category": "self",
"summary": "EcoStruxure\u2122 IT Data Center Expert - SEVD-2025-189-01 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2025-189-01.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390"
}
],
"title": "EcoStruxure\u2122 IT Data Center Expert",
"tracking": {
"current_release_date": "2025-07-08T04:00:00.000Z",
"generator": {
"date": "2025-07-07T04:00:00.000Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2025-189-01",
"initial_release_date": "2025-07-08T04:00:00.000Z",
"revision_history": [
{
"date": "2025-07-08T04:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=8.3",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 IT Data Center Expert Version 8.3 and prior",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 IT Data Center Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "9.0",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 IT Data Center Expert Version 9.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 IT Data Center Expert"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50121",
"cwe": {
"id": "CWE-78",
"name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\r\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\r\nover the web interface HTTP when enabled. HTTP is disabled by default.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-50121"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50122",
"cwe": {
"id": "CWE-331",
"name": "Insufficient Entropy"
},
"notes": [
{
"category": "description",
"text": "CWE-331: Insufficient Entropy vulnerability exists that could cause root password discovery when the \r\npassword generation algorithm is reverse engineered with access to installation or upgrade artifacts.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-50122"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50123",
"cwe": {
"id": "CWE-94",
"name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)"
},
"notes": [
{
"category": "description",
"text": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability exists that could cause remote \r\ncommand execution by a privileged account when the server is accessed via a console and through \r\nexploitation of the hostname input.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-50123"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50125",
"cwe": {
"id": "CWE-918",
"name": "Server-Side Request Forgery (SSRF)"
},
"notes": [
{
"category": "description",
"text": "CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthenticated remote \r\ncode execution when the server is accessed via the network with knowledge of hidden URLs and manipulation \r\nof host request header.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-50125"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-50124",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "description",
"text": "CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the \r\nserver is accessed by a privileged account via a console and through exploitation of a setup script.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-50124"
},
{
"acknowledgments": [
{
"names": [
"Jaggar Henry",
"Jim Becher"
],
"organization": "KoreLogic, Inc."
}
],
"cve": "CVE-2025-6438",
"cwe": {
"id": "CWE-611",
"name": "Improper Restriction of XML External Entity Reference"
},
"notes": [
{
"category": "description",
"text": "CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could \r\ncause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access\r\nwhen the server is accessed via the network using an application account.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 9.0 of EcoStruxure\u2122 IT Data Center Expert includes fixes \r\nfor these vulnerabilities and is available upon request from \r\nSchneider Electric\u2019s Customer Care Center.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately apply the following \r\nmitigations to reduce the risk of exploit:\r\n\u2022 Harden the DCE instance according to the cybersecurity best practices documented in the \r\nEcoStruxure\u2122 IT Data Center Expert Security Handbook",
"product_ids": [
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://community.se.com/t5/DCE-Security/EcoStruxure-IT-Data-Center-Expert-Security-Handbook/ta-p/446553"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-6438"
}
]
}
GHSA-4GH4-J9HH-74H5
Vulnerability from github – Published: 2025-07-11 12:30 – Updated: 2025-11-03 21:34CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created over the web interface HTTP when enabled. HTTP is disabled by default.
{
"affected": [],
"aliases": [
"CVE-2025-50121"
],
"database_specific": {
"cwe_ids": [
"CWE-78"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-07-11T10:15:23Z",
"severity": "CRITICAL"
},
"details": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\nvulnerability exists that could cause unauthenticated remote code execution when a malicious folder is created\nover the web interface HTTP when enabled. HTTP is disabled by default.",
"id": "GHSA-4gh4-j9hh-74h5",
"modified": "2025-11-03T21:34:05Z",
"published": "2025-07-11T12:30:32Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-50121"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-189-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-189-01.pdf"
},
{
"type": "WEB",
"url": "http://seclists.org/fulldisclosure/2025/Jul/6"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"type": "CVSS_V3"
},
{
"score": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.