CVE-2025-36035 (GCVE-0-2025-36035)
Vulnerability from cvelistv5 – Published: 2025-09-14 12:52 – Updated: 2025-09-15 15:59
VLAI
EPSS
VEX
Title
IBM PowerVM Hypervisor denial of service
Summary
IBM PowerVM Hypervisor FW950.00 through FW950.E0, FW1050.00 through FW1050.50, and FW1060.00 through FW1060.40 could allow a local privileged user to cause a denial of service by issuing a specially crafted IBM i hypervisor call that would disclose memory contents or consume excessive memory resources.
Severity
6.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-15 15:58 UTC
CWE
- CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7244813 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| IBM | PowerVM Hypervisor |
Affected:
FW950.00 , ≤ FW950.E0
(semver)
Affected: FW1050.00 , ≤ FW1050.50 (semver) Affected: FW1060.00 , ≤ FW1060.40 (semver) cpe:2.3:o:ibm:power9_system_firmware:fw950.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power9_system_firmware:fw950.E0:*:*:*:*:*:*:* cpe:2.3:o:ibm:power9_system_firmware:fw1050.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power9_system_firmware:fw1050.50:*:*:*:*:*:*:* cpe:2.3:o:ibm:power9_system_firmware:fw1060.00:*:*:*:*:*:*:* cpe:2.3:o:ibm:power9_system_firmware:fw1060.40:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-36035",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T15:58:51.498887Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T15:59:00.889Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power9_system_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw950.E0:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1050.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1050.50:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1060.40:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "PowerVM Hypervisor",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "FW950.E0",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1050.50",
"status": "affected",
"version": "FW1050.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.40",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM PowerVM Hypervisor FW950.00 through FW950.E0, FW1050.00 through FW1050.50, and FW1060.00 through FW1060.40 could allow a local privileged user to cause a denial of service by issuing a specially crafted IBM i hypervisor call that would disclose memory contents or consume excessive memory resources."
}
],
"value": "IBM PowerVM Hypervisor FW950.00 through FW950.E0, FW1050.00 through FW1050.50, and FW1060.00 through FW1060.40 could allow a local privileged user to cause a denial of service by issuing a specially crafted IBM i hypervisor call that would disclose memory contents or consume excessive memory resources."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-14T12:52:48.871Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7244813"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install 950.E1(950_182)/950.F0(950_192) or newer to remediate this vulnerability.\u003cbr\u003ePower 9\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System L922 (9008-22L)\u003c/li\u003e\u003cli\u003eIBM Power System S922 (9009-22A, 9009-22G)\u003c/li\u003e\u003cli\u003eIBM Power System H922 (9223-22H, 9223-22S)\u003c/li\u003e\u003cli\u003eIBM Power System S914 (9009-41A, 9009-41G)\u003c/li\u003e\u003cli\u003eIBM Power System S924 (9009-42A, 9009-42G)\u003c/li\u003e\u003cli\u003eIBM Power System H924 (9223-42H, 9223-42S)\u003c/li\u003e\u003cli\u003eIBM Power System E950 (9040-MR9)\u003c/li\u003e\u003cli\u003eIBM Power System E980 (9080-M9S)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cbr\u003eCustomers with the products below should install FW1050.51(1050_095)/FW1050.60(1050_090), FW1060.41(1060_120), or newer to remediate this vulnerability.\u003cbr\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1080 (9080-HEX)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1050.51(1050_113)/FW1050.60(1050_108), FW1060.41(1060_120), or newer to remediate this vulnerability.\u003cbr\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1022 (9105-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1024 (9105-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1022s (9105-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1014 (9105-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1022 (9786-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1024 (9786-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1050 (9043-MRX)\u003c/li\u003e\u003cli\u003eIBM Power System S1012 (9028-21B)\u003c/li\u003e\u003c/ol\u003e\n\n\u003cbr\u003e"
}
],
"value": "Customers with the products below should install 950.E1(950_182)/950.F0(950_192) or newer to remediate this vulnerability.\nPower 9\n\n * IBM Power System L922 (9008-22L)\n * IBM Power System S922 (9009-22A, 9009-22G)\n * IBM Power System H922 (9223-22H, 9223-22S)\n * IBM Power System S914 (9009-41A, 9009-41G)\n * IBM Power System S924 (9009-42A, 9009-42G)\n * IBM Power System H924 (9223-42H, 9223-42S)\n * IBM Power System E950 (9040-MR9)\n * IBM Power System E980 (9080-M9S)\n\nCustomers with the products below should install FW1050.51(1050_095)/FW1050.60(1050_090), FW1060.41(1060_120), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System E1080 (9080-HEX)\n\u00a0\n\nCustomers with the products below should install FW1050.51(1050_113)/FW1050.60(1050_108), FW1060.41(1060_120), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System S1022 (9105-22A)\n * IBM Power System S1024 (9105-42A)\n * IBM Power System S1022s (9105-22B)\n * IBM Power System S1014 (9105-41B)\n * IBM Power System L1022 (9786-22H)\n * IBM Power System L1024 (9786-42H)\n * IBM Power System E1050 (9043-MRX)\n * IBM Power System S1012 (9028-21B)"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM PowerVM Hypervisor denial of service",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2025-36035",
"datePublished": "2025-09-14T12:52:48.871Z",
"dateReserved": "2025-04-15T21:16:09.684Z",
"dateUpdated": "2025-09-15T15:59:00.889Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-36035",
"date": "2026-09-28",
"epss": "0.00131",
"percentile": "0.02263"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"cpes": [
"cpe:2.3:o:ibm:power9_system_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw950.E0:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1050.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1050.50:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1060.40:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "PowerVM Hypervisor",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "FW950.E0",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1050.50",
"status": "affected",
"version": "FW1050.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.40",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
}
]
}
],
"source": "psirt@us.ibm.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:powervm_hypervisor:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C075224C-3299-4E1F-BC3B-11EB6BDCF705",
"versionEndIncluding": "FW950.E0",
"versionStartIncluding": "FW950.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e950_\\(9040-mr9\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "9FF58E5C-0A54-4F2F-A426-0BFD1EACE991",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_e980_\\(9080-m9s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "9BE56BD8-DB0F-4151-9428-42F1B6452D99",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_h922_\\(9223-22h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "633D5D2E-300A-4896-8F90-57F9B7AFE01E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_h922_\\(9223-22s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E7851003-8D6B-4FE8-87D7-BE968E85E448",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_h924_\\(\\(9223-42s\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "D1F77E3F-524F-491E-AE7B-FAEE4DC251F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_h924_\\(9223-42h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "24CC25C2-BE64-4022-A229-D639CED27B00",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_l922_\\(9008-22l\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "61493605-7807-498B-9DD7-48B244AD0415",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s914_\\(9009-41a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "5D9CA070-A7E4-451A-9C3C-D2622E7A9A92",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s914_\\(9009-41g\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "003F591A-ACCD-497E-BF8A-DE090321D778",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s922_\\(9009-22a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "8AB350B1-3964-485A-AAB3-55558DD375BD",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s922_\\(9009-22g\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "95E5E77F-A5BB-46E7-B6B6-B02F242DE829",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s924_\\(9009-42a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "65A41386-AAE5-409C-9355-2EEB07F01926",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s924_\\(9009-42g\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "4038C5DB-DF9C-4661-9590-F6A0CD4D15D5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:powervm_hypervisor:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7B2026A2-926D-402B-8181-8AC2E90F4AC2",
"versionEndIncluding": "FW1050.50",
"versionStartIncluding": "FW1050.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:powervm_hypervisor:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B633D94D-3566-44D8-BA35-62F7942E8DB5",
"versionEndIncluding": "FW1060.40",
"versionStartIncluding": "FW1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1080_\\(9080-hex\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "DF85251B-E02C-4293-98F0-D331BF51CAC4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:powervm_hypervisor:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7B2026A2-926D-402B-8181-8AC2E90F4AC2",
"versionEndIncluding": "FW1050.50",
"versionStartIncluding": "FW1050.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:powervm_hypervisor:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B633D94D-3566-44D8-BA35-62F7942E8DB5",
"versionEndIncluding": "FW1060.40",
"versionStartIncluding": "FW1060.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ibm:power_system_e1050_\\(9043-mrx\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "061D193E-84BC-4DE7-96C4-B75D11769ED5",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_l1022_\\(9786-22h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2C09090-C18F-464A-8DEF-E23B5990E2A4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_l1024_\\(9786-42h\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "0170400B-89A7-4B44-9AA7-9A168C9CAE9C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s1012_\\(9028-21b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "7BED85F2-8CCB-417C-A739-23828966A036",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s1014_\\(9105-41b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "ECD54B80-5754-4C19-AE0C-F539DEF96DCB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s1022_\\(9105-22a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E3E15C41-9CBD-4F66-A176-07B3E9BBD81D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s1022s_\\(9105-22b\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "564A665A-7B94-40CE-A4D9-CDD0CCF52B2E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:ibm:power_system_s1024_\\(9105-42a\\):-:*:*:*:*:*:*:*",
"matchCriteriaId": "E49EE658-B8AE-48F7-A765-92BA3A630AA0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "IBM PowerVM Hypervisor FW950.00 through FW950.E0, FW1050.00 through FW1050.50, and FW1060.00 through FW1060.40 could allow a local privileged user to cause a denial of service by issuing a specially crafted IBM i hypervisor call that would disclose memory contents or consume excessive memory resources."
}
],
"id": "CVE-2025-36035",
"lastModified": "2026-06-17T09:14:24.130",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.5,
"impactScore": 4.7,
"source": "psirt@us.ibm.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 4.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-36035",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T15:58:51.498887Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-09-14T13:15:32.450",
"references": [
{
"source": "psirt@us.ibm.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.ibm.com/support/pages/node/7244813"
}
],
"sourceIdentifier": "psirt@us.ibm.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-770"
}
],
"source": "psirt@us.ibm.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-09-16T13:27:03+00:00",
"cve": "CVE-2025-36035",
"id": "CVE-2025-36035",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "IBM PowerVM Hypervisor denial of service",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-36035.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-36035",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T15:58:51.498887Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T15:58:55.264Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:o:ibm:power9_system_firmware:fw950.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw950.E0:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1050.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1050.50:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1060.00:*:*:*:*:*:*:*",
"cpe:2.3:o:ibm:power9_system_firmware:fw1060.40:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "PowerVM Hypervisor",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "FW950.E0",
"status": "affected",
"version": "FW950.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1050.50",
"status": "affected",
"version": "FW1050.00",
"versionType": "semver"
},
{
"lessThanOrEqual": "FW1060.40",
"status": "affected",
"version": "FW1060.00",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM PowerVM Hypervisor FW950.00 through FW950.E0, FW1050.00 through FW1050.50, and FW1060.00 through FW1060.40 could allow a local privileged user to cause a denial of service by issuing a specially crafted IBM i hypervisor call that would disclose memory contents or consume excessive memory resources."
}
],
"value": "IBM PowerVM Hypervisor FW950.00 through FW950.E0, FW1050.00 through FW1050.50, and FW1060.00 through FW1060.40 could allow a local privileged user to cause a denial of service by issuing a specially crafted IBM i hypervisor call that would disclose memory contents or consume excessive memory resources."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-14T12:52:48.871Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7244813"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCustomers with the products below should install 950.E1(950_182)/950.F0(950_192) or newer to remediate this vulnerability.\u003cbr\u003ePower 9\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System L922 (9008-22L)\u003c/li\u003e\u003cli\u003eIBM Power System S922 (9009-22A, 9009-22G)\u003c/li\u003e\u003cli\u003eIBM Power System H922 (9223-22H, 9223-22S)\u003c/li\u003e\u003cli\u003eIBM Power System S914 (9009-41A, 9009-41G)\u003c/li\u003e\u003cli\u003eIBM Power System S924 (9009-42A, 9009-42G)\u003c/li\u003e\u003cli\u003eIBM Power System H924 (9223-42H, 9223-42S)\u003c/li\u003e\u003cli\u003eIBM Power System E950 (9040-MR9)\u003c/li\u003e\u003cli\u003eIBM Power System E980 (9080-M9S)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cbr\u003eCustomers with the products below should install FW1050.51(1050_095)/FW1050.60(1050_090), FW1060.41(1060_120), or newer to remediate this vulnerability.\u003cbr\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System E1080 (9080-HEX)\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCustomers with the products below should install FW1050.51(1050_113)/FW1050.60(1050_108), FW1060.41(1060_120), or newer to remediate this vulnerability.\u003cbr\u003ePower 10\u003c/p\u003e\u003col\u003e\u003cli\u003eIBM Power System S1022 (9105-22A)\u003c/li\u003e\u003cli\u003eIBM Power System S1024 (9105-42A)\u003c/li\u003e\u003cli\u003eIBM Power System S1022s (9105-22B)\u003c/li\u003e\u003cli\u003eIBM Power System S1014 (9105-41B)\u003c/li\u003e\u003cli\u003eIBM Power System L1022 (9786-22H)\u003c/li\u003e\u003cli\u003eIBM Power System L1024 (9786-42H)\u003c/li\u003e\u003cli\u003eIBM Power System E1050 (9043-MRX)\u003c/li\u003e\u003cli\u003eIBM Power System S1012 (9028-21B)\u003c/li\u003e\u003c/ol\u003e\n\n\u003cbr\u003e"
}
],
"value": "Customers with the products below should install 950.E1(950_182)/950.F0(950_192) or newer to remediate this vulnerability.\nPower 9\n\n * IBM Power System L922 (9008-22L)\n * IBM Power System S922 (9009-22A, 9009-22G)\n * IBM Power System H922 (9223-22H, 9223-22S)\n * IBM Power System S914 (9009-41A, 9009-41G)\n * IBM Power System S924 (9009-42A, 9009-42G)\n * IBM Power System H924 (9223-42H, 9223-42S)\n * IBM Power System E950 (9040-MR9)\n * IBM Power System E980 (9080-M9S)\n\nCustomers with the products below should install FW1050.51(1050_095)/FW1050.60(1050_090), FW1060.41(1060_120), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System E1080 (9080-HEX)\n\u00a0\n\nCustomers with the products below should install FW1050.51(1050_113)/FW1050.60(1050_108), FW1060.41(1060_120), or newer to remediate this vulnerability.\nPower 10\n\n * IBM Power System S1022 (9105-22A)\n * IBM Power System S1024 (9105-42A)\n * IBM Power System S1022s (9105-22B)\n * IBM Power System S1014 (9105-41B)\n * IBM Power System L1022 (9786-22H)\n * IBM Power System L1024 (9786-42H)\n * IBM Power System E1050 (9043-MRX)\n * IBM Power System S1012 (9028-21B)"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM PowerVM Hypervisor denial of service",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2025-36035",
"datePublished": "2025-09-14T12:52:48.871Z",
"dateReserved": "2025-04-15T21:16:09.684Z",
"dateUpdated": "2025-09-14T12:52:48.871Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…