CVE-2025-14884 (GCVE-0-2025-14884)
Vulnerability from cvelistv5
Published
2025-12-18 17:02
Modified
2025-12-18 18:51
CWE
Summary
A vulnerability was detected in D-Link DIR-605 202WWB03. Affected by this issue is some unknown functionality of the component Firmware Update Service. Performing manipulation results in command injection. The attack can be initiated remotely. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
Impacted products
Vendor Product Version
D-Link DIR-605 Version: 202WWB03
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14884",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-18T18:44:43.253973Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-18T18:51:29.216Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Firmware Update Service"
          ],
          "product": "DIR-605",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "202WWB03"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "tian (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in D-Link DIR-605 202WWB03. Affected by this issue is some unknown functionality of the component Firmware Update Service. Performing manipulation results in command injection. The attack can be initiated remotely. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 8.3,
            "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-18T17:02:11.629Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-337372 | D-Link DIR-605 Firmware Update Service command injection",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.337372"
        },
        {
          "name": "VDB-337372 | CTI Indicators (IOB, IOC, TTP)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.337372"
        },
        {
          "name": "Submit #715465 | D-Link DIR605 B1v202WWB03 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.715465"
        },
        {
          "tags": [
            "exploit",
            "patch"
          ],
          "url": "https://tzh00203.notion.site/D-Link-DIR605-B1v202WWB03-Command-Injection-in-Firmware-Update-2cab5c52018a80de8df7f427ac2faf0e?source=copy_link"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-18T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-18T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-18T13:21:04.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DIR-605 Firmware Update Service command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14884",
    "datePublished": "2025-12-18T17:02:11.629Z",
    "dateReserved": "2025-12-18T12:16:00.834Z",
    "dateUpdated": "2025-12-18T18:51:29.216Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-14884\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-12-18T17:15:47.480\",\"lastModified\":\"2025-12-19T18:00:18.330\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[{\"sourceIdentifier\":\"cna@vuldb.com\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was detected in D-Link DIR-605 202WWB03. Affected by this issue is some unknown functionality of the component Firmware Update Service. Performing manipulation results in command injection. The attack can be initiated remotely. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:M/C:C/I:C/A:C\",\"baseScore\":8.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"MULTIPLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":6.4,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-74\"},{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"references\":[{\"url\":\"https://tzh00203.notion.site/D-Link-DIR605-B1v202WWB03-Command-Injection-in-Firmware-Update-2cab5c52018a80de8df7f427ac2faf0e?source=copy_link\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?ctiid.337372\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?id.337372\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?submit.715465\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://www.dlink.com/\",\"source\":\"cna@vuldb.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-14884\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-12-18T18:44:43.253973Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-12-18T18:44:47.926Z\"}}], \"cna\": {\"tags\": [\"unsupported-when-assigned\"], \"title\": \"D-Link DIR-605 Firmware Update Service command injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"tian (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.6, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 8.3, \"vectorString\": \"AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"D-Link\", \"modules\": [\"Firmware Update Service\"], \"product\": \"DIR-605\", \"versions\": [{\"status\": \"affected\", \"version\": \"202WWB03\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-12-18T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-12-18T01:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-12-18T13:21:04.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.337372\", \"name\": \"VDB-337372 | D-Link DIR-605 Firmware Update Service command injection\", \"tags\": [\"vdb-entry\"]}, {\"url\": \"https://vuldb.com/?ctiid.337372\", \"name\": \"VDB-337372 | CTI Indicators (IOB, IOC, TTP)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.715465\", \"name\": \"Submit #715465 | D-Link DIR605 B1v202WWB03 Command Injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://tzh00203.notion.site/D-Link-DIR605-B1v202WWB03-Command-Injection-in-Firmware-Update-2cab5c52018a80de8df7f427ac2faf0e?source=copy_link\", \"tags\": [\"exploit\", \"patch\"]}, {\"url\": \"https://www.dlink.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was detected in D-Link DIR-605 202WWB03. Affected by this issue is some unknown functionality of the component Firmware Update Service. Performing manipulation results in command injection. The attack can be initiated remotely. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"Command Injection\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-74\", \"description\": \"Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-12-18T17:02:11.629Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-14884\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-12-18T18:51:29.216Z\", \"dateReserved\": \"2025-12-18T12:16:00.834Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-12-18T17:02:11.629Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…