CVE-2025-12047 (GCVE-0-2025-12047)
Vulnerability from cvelistv5
Published
2025-11-12 19:18
Modified
2025-11-12 21:03
CWE
  • CWE-295 - Improper Certificate Validation
Summary
A vulnerability was reported in the Lenovo Scanner pro application during an internal security assessment that, under certain circumstances, could allow an attacker on the same logical network to disclose sensitive user files from the application.
Impacted products
Vendor Product Version
Lenovo Scanner Pro Version: 0   < 1.2.7
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12047",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-12T20:37:17.874476Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-12T21:03:27.695Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Android"
          ],
          "product": "Scanner Pro",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.2.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:lenovo:scanner_pro:*:*:android:*:*:*:*:*",
                  "versionEndExcluding": "1.2.7",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability was reported in the Lenovo Scanner pro application during an internal security assessment that, under certain circumstances, could allow an attacker on the same logical network to disclose sensitive user files from the application.\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability was reported in the Lenovo Scanner pro application during an internal security assessment that, under certain circumstances, could allow an attacker on the same logical network to disclose sensitive user files from the application."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295: Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-12T19:18:57.396Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "url": "https://iknow.lenovo.com.cn/detail/434327"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eUpdate Lenovo Scanner Pro application to version 1.2.7 or later.\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/div\u003e"
            }
          ],
          "value": "Update Lenovo Scanner Pro application to version 1.2.7 or later."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.3.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2025-12047",
    "datePublished": "2025-11-12T19:18:57.396Z",
    "dateReserved": "2025-10-21T20:07:41.750Z",
    "dateUpdated": "2025-11-12T21:03:27.695Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-12047\",\"sourceIdentifier\":\"psirt@lenovo.com\",\"published\":\"2025-11-12T20:15:37.647\",\"lastModified\":\"2025-11-14T16:42:30.503\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was reported in the Lenovo Scanner pro application during an internal security assessment that, under certain circumstances, could allow an attacker on the same logical network to disclose sensitive user files from the application.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"psirt@lenovo.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.0,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"psirt@lenovo.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.6,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"psirt@lenovo.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]}],\"references\":[{\"url\":\"https://iknow.lenovo.com.cn/detail/434327\",\"source\":\"psirt@lenovo.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-12047\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-11-12T20:37:17.874476Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-11-12T20:37:20.972Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 6, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.3, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Lenovo\", \"product\": \"Scanner Pro\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.2.7\", \"versionType\": \"custom\"}], \"platforms\": [\"Android\"], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Update Lenovo Scanner Pro application to version 1.2.7 or later.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003e\u003cdiv\u003e\u003cdiv\u003e\u003cp\u003eUpdate Lenovo Scanner Pro application to version 1.2.7 or later.\u003c/p\u003e\u003c/div\u003e\u003c/div\u003e\u003c/div\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://iknow.lenovo.com.cn/detail/434327\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.3.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was reported in the Lenovo Scanner pro application during an internal security assessment that, under certain circumstances, could allow an attacker on the same logical network to disclose sensitive user files from the application.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A vulnerability was reported in the Lenovo Scanner pro application during an internal security assessment that, under certain circumstances, could allow an attacker on the same logical network to disclose sensitive user files from the application.\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-295\", \"description\": \"CWE-295: Improper Certificate Validation\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:lenovo:scanner_pro:*:*:android:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"1.2.7\", \"versionStartIncluding\": \"0\"}], \"operator\": \"OR\"}], \"operator\": \"OR\"}], \"providerMetadata\": {\"orgId\": \"da227ddf-6e25-4b41-b023-0f976dcaca4b\", \"shortName\": \"lenovo\", \"dateUpdated\": \"2025-11-12T19:18:57.396Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-12047\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-11-12T21:03:27.695Z\", \"dateReserved\": \"2025-10-21T20:07:41.750Z\", \"assignerOrgId\": \"da227ddf-6e25-4b41-b023-0f976dcaca4b\", \"datePublished\": \"2025-11-12T19:18:57.396Z\", \"assignerShortName\": \"lenovo\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…