CVE-2024-8518 (GCVE-0-2024-8518)
Vulnerability from cvelistv5 – Published: 2024-10-08 10:12 – Updated: 2024-10-08 13:51- CWE-20 - Improper Input Validation
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | Zelio Soft 2 |
Affected:
Versions prior to 5.4.2.2
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8518",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-08T12:43:34.444260Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T13:51:42.894Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Zelio Soft 2",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to 5.4.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\n2 application when a specially crafted project file is loaded by an application user."
}
],
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\n2 application when a specially crafted project file is loaded by an application user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T10:12:52.204Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-8518",
"datePublished": "2024-10-08T10:12:52.204Z",
"dateReserved": "2024-09-06T14:42:44.193Z",
"dateUpdated": "2024-10-08T13:51:42.894Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-8518",
"date": "2026-05-27",
"epss": "0.00045",
"percentile": "0.1388"
},
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\\n2 application when a specially crafted project file is loaded by an application user.\"}, {\"lang\": \"es\", \"value\": \"CWE-20: Existe una vulnerabilidad de validaci\\u00f3n de entrada incorrecta que podr\\u00eda provocar un bloqueo de la aplicaci\\u00f3n Zelio Soft 2 cuando un usuario de la aplicaci\\u00f3n carga un archivo de proyecto especialmente manipulado.\"}]",
"id": "CVE-2024-8518",
"lastModified": "2024-10-10T12:56:30.817",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L\", \"baseScore\": 3.3, \"baseSeverity\": \"LOW\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 1.4}]}",
"published": "2024-10-08T10:15:05.340",
"references": "[{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf\", \"source\": \"cybersecurity@se.com\"}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-8518\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-10-08T10:15:05.340\",\"lastModified\":\"2024-10-10T12:56:30.817\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\\n2 application when a specially crafted project file is loaded by an application user.\"},{\"lang\":\"es\",\"value\":\"CWE-20: Existe una vulnerabilidad de validaci\u00f3n de entrada incorrecta que podr\u00eda provocar un bloqueo de la aplicaci\u00f3n Zelio Soft 2 cuando un usuario de la aplicaci\u00f3n carga un archivo de proyecto especialmente manipulado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf\",\"source\":\"cybersecurity@se.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-8518\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-08T12:43:34.444260Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-08T12:44:38.488Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 3.3, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"LOW\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"Zelio Soft 2\", \"versions\": [{\"status\": \"affected\", \"version\": \"Versions prior to 5.4.2.2\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\\n2 application when a specially crafted project file is loaded by an application user.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\\n2 application when a specially crafted project file is loaded by an application user.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2024-10-08T10:12:52.204Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-8518\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-08T13:51:42.894Z\", \"dateReserved\": \"2024-09-06T14:42:44.193Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2024-10-08T10:12:52.204Z\", \"assignerShortName\": \"schneider\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2024-AVI-0845
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Harmony iPC – HMIBSC IIoT Edge Box Core (cette famille de produits est en fin de vie et ne recevra plus de correctifs de sécurité) | ||
| Schneider Electric | N/A | EVlink Home Smart versions antérieures à 2.0.6.0.0 | ||
| Schneider Electric | N/A | System Monitor application dans les séries Harmony Industrial PC HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP toutes versions, aucun correctif n'est disponible, l'éditeur recommande de désinstaller le composant | ||
| Schneider Electric | N/A | Schneider Charge versions antérieures à 1.13.4 | ||
| Schneider Electric | N/A | Zelio Soft 2 versions antérieures à 5.4.2.2 | ||
| Schneider Electric | N/A | EcoStruxure EV Charging Expert versions antérieures à V6.0.0 | ||
| Schneider Electric | N/A | Easergy Studio versions antérieures à 9.3.4 | ||
| Schneider Electric | N/A | System Monitor application dans les séries Pro-face Industrial PC PS5000 toutes versions, aucun correctif n'est disponible, l'éditeur recommande de désinstaller le composant | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert (PME) versions 2022 sans le dernier correctif de sécurité | ||
| Schneider Electric | N/A | EcoStruxure IT Data Center Expert versions antérieures à 8.2 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Harmony iPC \u2013 HMIBSC IIoT Edge Box Core (cette famille de produits est en fin de vie et ne recevra plus de correctifs de s\u00e9curit\u00e9)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVlink Home Smart versions ant\u00e9rieures \u00e0 2.0.6.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "System Monitor application dans les s\u00e9ries Harmony Industrial PC HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP toutes versions, aucun correctif n\u0027est disponible, l\u0027\u00e9diteur recommande de d\u00e9sinstaller le composant",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Charge versions ant\u00e9rieures \u00e0 1.13.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Zelio Soft 2 versions ant\u00e9rieures \u00e0 5.4.2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure EV Charging Expert versions ant\u00e9rieures \u00e0 V6.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy Studio versions ant\u00e9rieures \u00e0 9.3.4 ",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "System Monitor application dans les s\u00e9ries Pro-face Industrial PC PS5000 toutes versions, aucun correctif n\u0027est disponible, l\u0027\u00e9diteur recommande de d\u00e9sinstaller le composant",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions 2022 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure IT Data Center Expert versions ant\u00e9rieures \u00e0 8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-8518",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8518"
},
{
"name": "CVE-2024-8531",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8531"
},
{
"name": "CVE-2024-8884",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8884"
},
{
"name": "CVE-2024-8070",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8070"
},
{
"name": "CVE-2024-9002",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-9002"
},
{
"name": "CVE-2024-9005",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-9005"
},
{
"name": "CVE-2024-8530",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8530"
},
{
"name": "CVE-2024-8422",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8422"
}
],
"links": [],
"reference": "CERTFR-2024-AVI-0845",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-10-08T00:00:00.000000"
},
{
"description": "Ajout du bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-04 du 10 octobre 2024.",
"revision_date": "2024-10-09T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-03.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-08",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-08\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-08.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-05.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-06",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-04.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-01.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-02.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-07",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-07.pdf"
}
]
}
CERTFR-2024-AVI-0845
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et une atteinte à la confidentialité des données.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Harmony iPC – HMIBSC IIoT Edge Box Core (cette famille de produits est en fin de vie et ne recevra plus de correctifs de sécurité) | ||
| Schneider Electric | N/A | EVlink Home Smart versions antérieures à 2.0.6.0.0 | ||
| Schneider Electric | N/A | System Monitor application dans les séries Harmony Industrial PC HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP toutes versions, aucun correctif n'est disponible, l'éditeur recommande de désinstaller le composant | ||
| Schneider Electric | N/A | Schneider Charge versions antérieures à 1.13.4 | ||
| Schneider Electric | N/A | Zelio Soft 2 versions antérieures à 5.4.2.2 | ||
| Schneider Electric | N/A | EcoStruxure EV Charging Expert versions antérieures à V6.0.0 | ||
| Schneider Electric | N/A | Easergy Studio versions antérieures à 9.3.4 | ||
| Schneider Electric | N/A | System Monitor application dans les séries Pro-face Industrial PC PS5000 toutes versions, aucun correctif n'est disponible, l'éditeur recommande de désinstaller le composant | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert (PME) versions 2022 sans le dernier correctif de sécurité | ||
| Schneider Electric | N/A | EcoStruxure IT Data Center Expert versions antérieures à 8.2 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Harmony iPC \u2013 HMIBSC IIoT Edge Box Core (cette famille de produits est en fin de vie et ne recevra plus de correctifs de s\u00e9curit\u00e9)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EVlink Home Smart versions ant\u00e9rieures \u00e0 2.0.6.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "System Monitor application dans les s\u00e9ries Harmony Industrial PC HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP toutes versions, aucun correctif n\u0027est disponible, l\u0027\u00e9diteur recommande de d\u00e9sinstaller le composant",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Charge versions ant\u00e9rieures \u00e0 1.13.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Zelio Soft 2 versions ant\u00e9rieures \u00e0 5.4.2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure EV Charging Expert versions ant\u00e9rieures \u00e0 V6.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy Studio versions ant\u00e9rieures \u00e0 9.3.4 ",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "System Monitor application dans les s\u00e9ries Pro-face Industrial PC PS5000 toutes versions, aucun correctif n\u0027est disponible, l\u0027\u00e9diteur recommande de d\u00e9sinstaller le composant",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert (PME) versions 2022 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure IT Data Center Expert versions ant\u00e9rieures \u00e0 8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2024-8518",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8518"
},
{
"name": "CVE-2024-8531",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8531"
},
{
"name": "CVE-2024-8884",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8884"
},
{
"name": "CVE-2024-8070",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8070"
},
{
"name": "CVE-2024-9002",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-9002"
},
{
"name": "CVE-2024-9005",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-9005"
},
{
"name": "CVE-2024-8530",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8530"
},
{
"name": "CVE-2024-8422",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8422"
}
],
"links": [],
"reference": "CERTFR-2024-AVI-0845",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-10-08T00:00:00.000000"
},
{
"description": "Ajout du bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-04 du 10 octobre 2024.",
"revision_date": "2024-10-09T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Schneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-03",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-03.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-08",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-08\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-08.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-05",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-05.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-06",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-04",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-04.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-01",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-01.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-02",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-02.pdf"
},
{
"published_at": "2024-10-08",
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2024-282-07",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-07.pdf"
}
]
}
BDU:2024-09623
Vulnerability from fstec - Published: 08.10.2024{
"CVSS 2.0": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
"CVSS 3.0": "AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 5.4.2.2 (Zelio Soft 2)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439: \nhttps://download.schneider-electric.com/doc/SEVD-2024-282-06/SEVD-2024-282-06.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "08.10.2024",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "15.11.2024",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "15.11.2024",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2024-09623",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2024-8518",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Zelio Soft 2",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Zelio Soft 2 \u0434\u043b\u044f \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0440\u0435\u043b\u0435 Zelio Logic, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u043e\u0439 \u0432\u0432\u0435\u0434\u0435\u043d\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0432\u0432\u043e\u0434\u0438\u043c\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445 (CWE-20)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Zelio Soft 2 \u0434\u043b\u044f \u0438\u043d\u0442\u0435\u043b\u043b\u0435\u043a\u0442\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0440\u0435\u043b\u0435 Zelio Logic \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u043e\u0439 \u0432\u0432\u0435\u0434\u0435\u043d\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u043f\u0443\u0442\u0451\u043c \u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u043e\u0437\u0434\u0430\u043d\u043d\u043e\u0433\u043e \u0444\u0430\u0439\u043b\u0430 \u043f\u0440\u043e\u0435\u043a\u0442\u0430",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://download.schneider-electric.com/doc/SEVD-2024-282-06/SEVD-2024-282-06.pdf \nhttps://nvd.nist.gov/vuln/detail/CVE-2024-8518 \nhttps://www.prio-n.com/kb/vulnerability/CVE-2024-8518",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u0421\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-20",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041d\u0438\u0437\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 2,1)\n\u041d\u0438\u0437\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 3,3)"
}
FKIE_CVE-2024-8518
Vulnerability from fkie_nvd - Published: 2024-10-08 10:15 - Updated: 2026-04-15 00:35| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\n2 application when a specially crafted project file is loaded by an application user."
},
{
"lang": "es",
"value": "CWE-20: Existe una vulnerabilidad de validaci\u00f3n de entrada incorrecta que podr\u00eda provocar un bloqueo de la aplicaci\u00f3n Zelio Soft 2 cuando un usuario de la aplicaci\u00f3n carga un archivo de proyecto especialmente manipulado."
}
],
"id": "CVE-2024-8518",
"lastModified": "2026-04-15T00:35:42.020",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
},
"published": "2024-10-08T10:15:05.340",
"references": [
{
"source": "cybersecurity@se.com",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
GHSA-J6RP-5G87-GHHJ
Vulnerability from github – Published: 2024-10-08 12:30 – Updated: 2024-10-08 12:30CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft 2 application when a specially crafted project file is loaded by an application user.
{
"affected": [],
"aliases": [
"CVE-2024-8518"
],
"database_specific": {
"cwe_ids": [
"CWE-20"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2024-10-08T10:15:05Z",
"severity": "LOW"
},
"details": "CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft\n2 application when a specially crafted project file is loaded by an application user.",
"id": "GHSA-j6rp-5g87-ghhj",
"modified": "2024-10-08T12:30:21Z",
"published": "2024-10-08T12:30:21Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-8518"
},
{
"type": "WEB",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"type": "CVSS_V3"
}
]
}
ICSA-24-284-14
Vulnerability from csaf_cisa - Published: 2024-10-10 06:00 - Updated: 2024-10-10 06:00{
"document": {
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro Zero Day Initiative",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow an attacker to achieve arbitrary code execution, cause a denial-of-service condition, or loss of confidentiality and integrity.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Energy, Critical Manufacturing",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-24-284-14 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-284-14.json"
},
{
"category": "self",
"summary": "ICSA Advisory ICSA-24-284-14 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-284-14"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Schneider Electric Zelio Soft 2",
"tracking": {
"current_release_date": "2024-10-10T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-24-284-14",
"initial_release_date": "2024-10-10T06:00:00.000000Z",
"revision_history": [
{
"date": "2024-10-10T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.4.2.2",
"product": {
"name": "Schneider Electric Zelio Soft 2: \u003c5.4.2.2",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Zelio Soft 2"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-8422",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "A Use After Free vulnerability exists that could cause arbitrary code execution, denial-of-service and loss of confidentiality \u0026 integrity if an application user opens a malicious Zelio Soft 2 project file.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8422"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends that customers update to Version 5.4.2.2. It can be updated through the Schneider Electric Software Update (SESU) application and is also available for download here.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range/542-zeliosoft/#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2024-8518",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft 2 application if a specially crafted project file is loaded by an application user.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "www.cve.org",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-8518"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends that customers update to Version 5.4.2.2. It can be updated through the Schneider Electric Software Update (SESU) application and is also available for download here.",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.se.com/ww/en/product-range/542-zeliosoft/#software-and-firmware"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
SEVD-2024-282-06
Vulnerability from csaf_se - Published: 2024-10-08 00:00 - Updated: 2024-10-08 00:00CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when application user opens a malicious Zelio Soft 2 project file.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Zelio Soft 2 Versions prior to 5.4.2.2
Schneider Electric / Zelio Soft 2
|
<5.4.2.2 |
Vendor Fix
fix
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Zelio Soft 2 Version 5.4.2.2
Schneider Electric / Zelio Soft 2
|
5.4.2.2 |
CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft 2 application when a specially crafted project file is loaded by an application user.
CWE-20 - Improper Input Validation| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Zelio Soft 2 Versions prior to 5.4.2.2
Schneider Electric / Zelio Soft 2
|
<5.4.2.2 |
Vendor Fix
fix
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Zelio Soft 2 Version 5.4.2.2
Schneider Electric / Zelio Soft 2
|
5.4.2.2 |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of vulnerabilities in its Zelio Soft 2 product. \r\nThe Zelio Soft 2 software for Zelio Logic smart relays (SR2/ SR3) enables programming in \r\nLADDER language or in function block diagram (FBD) language simulation, monitoring and \r\nsupervision uploading and downloading of programs output of personalized files automatic \r\ncompiling of programs.\r\nFailure to apply the fix provided below may risk remote code execution, which could result in \r\nresource exhaustion, information disclosure, or denial of service.",
"title": "Overview"
},
{
"category": "summary",
"text": "Customers should use appropriate patching methodologies when applying these patches to \r\ntheir systems. We strongly recommend the use of back-ups and evaluating the impact of these \r\npatches in a Test and Development environment or on an offline infrastructure. Contact \r\nSchneider Electric\u2019s Customer Care Center if you need assistance removing a patch. ",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "Zelio Soft 2 - SEVD-2024-282-06 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-06.pdf"
},
{
"category": "self",
"summary": "Zelio Soft 2 - SEVD-2024-282-06 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2024-282-06.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "Zelio Soft 2",
"tracking": {
"current_release_date": "2024-10-08T00:00:00.000Z",
"generator": {
"date": "2024-10-08T00:00:00Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2024-282-06",
"initial_release_date": "2024-10-08T00:00:00.000Z",
"revision_history": [
{
"date": "2024-10-08T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c5.4.2.2",
"product": {
"name": "Schneider Electric Zelio Soft 2 Versions prior to 5.4.2.2",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Zelio Soft 2"
},
{
"branches": [
{
"category": "product_version",
"name": "5.4.2.2",
"product": {
"name": "Schneider Electric Zelio Soft 2 Version 5.4.2.2",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Zelio Soft 2"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"rgod"
],
"organization": "Trend Micro Zero Day Initiative"
}
],
"cve": "CVE-2024-8422",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "description",
"text": "CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial \r\nof service and loss of confidentiality \u0026 integrity when application user opens a malicious Zelio \r\nSoft 2 project file.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 5.4.2.2 of Zelio Soft 2 includes a fix for these \r\nvulnerabilities and can be updated through the Schneider \r\nElectric Software Update (SESU) application and is also \r\navailable for download here:\r\nhttps://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Encrypt project files when stored and restrict the access to only trusted users. \r\n\u2022 When exchanging files over the network, use secure communication protocols. \r\n\u2022 Only open project files received from a trusted source.\r\n\u2022 Compute a hash of the project files and regularly check the consistency of this hash to \r\nverify the integrity before usage.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2024-8422"
},
{
"acknowledgments": [
{
"names": [
"Jie Chen"
],
"organization": "nsfocus"
}
],
"cve": "CVE-2024-8518",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "description",
"text": "CWE-20: Improper Input Validation vulnerability exists that could cause a crash of the Zelio Soft \r\n2 application when a specially crafted project file is loaded by an application user.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2"
],
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Version 5.4.2.2 of Zelio Soft 2 includes a fix for these \r\nvulnerabilities and can be updated through the Schneider \r\nElectric Software Update (SESU) application and is also \r\navailable for download here:\r\nhttps://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range/542-zelio-soft/#software-and-firmware"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit: \r\n\u2022 Encrypt project files when stored and restrict the access to only trusted users. \r\n\u2022 When exchanging files over the network, use secure communication protocols. \r\n\u2022 Only open project files received from a trusted source.\r\n\u2022 Compute a hash of the project files and regularly check the consistency of this hash to \r\nverify the integrity before usage.",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
}
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2024-8518"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.