CVE-2024-47864
Vulnerability from cvelistv5
Published
2024-12-23 00:18
Modified
2024-12-24 00:39
Summary
home 5G HR02, Wi-Fi STATION SH-52B, and Wi-Fi STATION SH-54C contain a buffer overflow vulnerability in the hidden debug function. A remote unauthenticated attacker may get the web console of the product down.
Impacted products
Vendor Product Version
Sharp Corporation Wi-Fi STATION SH-52B Version: S3.87.11 and earlier
Sharp Corporation Wi-Fi STATION SH-54C Version: S6.60.00 and earlier
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-47864",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-24T00:35:27.338755Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-24T00:39:37.171Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "home 5G HR02",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "S5.82.00 and earlier"
            }
          ]
        },
        {
          "product": "Wi-Fi STATION SH-52B",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "S3.87.11 and earlier"
            }
          ]
        },
        {
          "product": "Wi-Fi STATION SH-54C",
          "vendor": "Sharp Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "S6.60.00 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "home 5G HR02, Wi-Fi STATION SH-52B, and Wi-Fi STATION SH-54C contain a buffer overflow vulnerability in the hidden debug function. A remote unauthenticated attacker may get the web console of the product down."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer overflow",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-23T00:18:03.318Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://k-tai.sharp.co.jp/support/info/info083.html"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN61635834/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-47864",
    "datePublished": "2024-12-23T00:18:03.318Z",
    "dateReserved": "2024-12-02T06:03:34.435Z",
    "dateUpdated": "2024-12-24T00:39:37.171Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-47864\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2024-12-23T01:15:07.553\",\"lastModified\":\"2024-12-23T01:15:07.553\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"home 5G HR02, Wi-Fi STATION SH-52B, and Wi-Fi STATION SH-54C contain a buffer overflow vulnerability in the hidden debug function. A remote unauthenticated attacker may get the web console of the product down.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"vultures@jpcert.or.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"vultures@jpcert.or.jp\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"references\":[{\"url\":\"https://jvn.jp/en/jp/JVN61635834/\",\"source\":\"vultures@jpcert.or.jp\"},{\"url\":\"https://k-tai.sharp.co.jp/support/info/info083.html\",\"source\":\"vultures@jpcert.or.jp\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.