CVE-2024-33893
Vulnerability from cvelistv5
Published
2024-08-02 00:00
Modified
2024-10-30 19:18
Summary
Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are vulnerable to XSS when displaying the logs due to improper input sanitization. This is fixed in version 21.2s10 and 22.1s3.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-33893",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-05T19:39:40.611876Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T19:18:21.436Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-18T08:02:59.637Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2024/Aug/19"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are vulnerable to XSS when displaying the logs due to improper input sanitization. This is fixed in version 21.2s10 and 22.1s3."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-12T15:24:04.691161",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.ewon.biz/products/cosy/ewon-cosy-wifi"
        },
        {
          "url": "https://www.hms-networks.com/cyber-security"
        },
        {
          "url": "https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-07-29-001--ewon-several-cosy--vulnerabilities.pdf"
        },
        {
          "url": "https://blog.syss.com/posts/hacking-a-secure-industrial-remote-access-gateway/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-33893",
    "datePublished": "2024-08-02T00:00:00",
    "dateReserved": "2024-04-28T00:00:00",
    "dateUpdated": "2024-10-30T19:18:21.436Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-33893\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2024-08-02T18:16:18.743\",\"lastModified\":\"2024-11-21T09:17:40.830\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cosy+ devices running a firmware 21.x below 21.2s10 or a firmware 22.x below 22.1s3 are vulnerable to XSS when displaying the logs due to improper input sanitization. This is fixed in version 21.2s10 and 22.1s3.\"},{\"lang\":\"es\",\"value\":\"Los dispositivos Cosy+ que ejecutan un firmware 21.x inferior a 21.2s10 o un firmware 22.x inferior a 22.1s3 son vulnerables a XSS cuando muestran los registros debido a una sanitizaci\u00f3n de entrada inadecuada. Esto se solucion\u00f3 en las versiones 21.2s10 y 22.1s3.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hms-networks:ewon_cosy\\\\+_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"21.0\",\"versionEndIncluding\":\"21.2s10\",\"matchCriteriaId\":\"0D2D5C2F-AA95-47DF-BD24-8A2C355BBEC6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hms-networks:ewon_cosy\\\\+_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"22.0\",\"versionEndIncluding\":\"22.1s3\",\"matchCriteriaId\":\"9048EBCA-4083-4C50-8499-A6FA6346AAA0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hms-networks:ewon_cosy\\\\+_4g_apac:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"26AE4359-63AD-4451-AACD-D621B9D422C7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hms-networks:ewon_cosy\\\\+_4g_eu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"95A7AEB3-53A0-4B77-8DFB-8E92E4B24462\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hms-networks:ewon_cosy\\\\+_4g_jp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A0C2B08D-D645-4C04-B010-4FF85642F7B5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hms-networks:ewon_cosy\\\\+_4g_na:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B85678D5-71F7-47EA-A21F-272BA9C02B33\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hms-networks:ewon_cosy\\\\+_ethernet:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F5917C5-AD12-4FB3-9DBB-D757DC053427\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hms-networks:ewon_cosy\\\\+_wifi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D1475F50-11AB-4290-8D1D-FFCA2245B0B3\"}]}]}],\"references\":[{\"url\":\"https://blog.syss.com/posts/hacking-a-secure-industrial-remote-access-gateway/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://hmsnetworks.blob.core.windows.net/nlw/docs/default-source/products/cybersecurity/security-advisory/hms-security-advisory-2024-07-29-001--ewon-several-cosy--vulnerabilities.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.ewon.biz/products/cosy/ewon-cosy-wifi\",\"source\":\"cve@mitre.org\",\"tags\":[\"Product\"]},{\"url\":\"https://www.hms-networks.com/cyber-security\",\"source\":\"cve@mitre.org\",\"tags\":[\"VDB Entry\",\"Vendor Advisory\"]},{\"url\":\"http://seclists.org/fulldisclosure/2024/Aug/19\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.