GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-0928 (GCVE-0-2024-0928)

Vulnerability from cvelistv5 – Published: 2024-01-26 15:31 – Updated: 2025-06-17 21:19
VLAI
Title
Tenda AC10U fromDhcpListClient stack-based overflow
Summary
A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-01-26 20:40 UTC
CWE
  • CWE-121 - Stack-based Buffer Overflow
References
URL Tags
https://vuldb.com/?id.252133 vdb-entrytechnical-description
https://vuldb.com/?ctiid.252133 signaturepermissions-required
https://github.com/yaoyue123/iot/blob/main/Tenda/… exploit
Impacted products
Vendor Product Version CPE status
Tenda AC10U Affected: 15.03.06.49_multi_TDE01
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:18:18.976Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.252133"
          },
          {
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.252133"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromDhcpListClient_1.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0928",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-26T20:40:16.864820Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-17T21:19:31.739Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10U",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.49_multi_TDE01"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "chenjun ma (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC10U 15.03.06.49_multi_TDE01 wurde eine kritische Schwachstelle ausgemacht. Dabei geht es um die Funktion fromDhcpListClient. Mit der Manipulation des Arguments page/listN mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-26T15:31:03.551Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.252133"
        },
        {
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.252133"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromDhcpListClient_1.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-01-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-01-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-01-26T09:26:52.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10U fromDhcpListClient stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-0928",
    "datePublished": "2024-01-26T15:31:03.551Z",
    "dateReserved": "2024-01-26T08:21:32.378Z",
    "dateUpdated": "2025-06-17T21:19:31.739Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-0928",
      "date": "2026-09-18",
      "epss": "0.01057",
      "percentile": "0.62928"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D1C36BB3-509E-4120-B2EC-F4D061A71F2A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BFF286BB-A1D3-4E51-AB31-B5A531A8B440",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "es",
          "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC10U 15.03.06.49_multi_TDE01. Ha sido declarada cr\u00edtica. La funci\u00f3n fromDhcpListClient es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento page/listN conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. La explotaci\u00f3n ha sido divulgada al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-252133. NOTA: Se contact\u00f3 primeramente con proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
        }
      ],
      "id": "CVE-2024-0928",
      "lastModified": "2024-11-21T08:47:46.417",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "MULTIPLE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 6.4,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "cna@vuldb.com",
            "type": "Secondary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 4.7,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 1.2,
            "impactScore": 3.4,
            "source": "cna@vuldb.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2024-01-26T16:15:21.707",
      "references": [
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromDhcpListClient_1.md"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?ctiid.252133"
        },
        {
          "source": "cna@vuldb.com",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?id.252133"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromDhcpListClient_1.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?ctiid.252133"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://vuldb.com/?id.252133"
        }
      ],
      "sourceIdentifier": "cna@vuldb.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-121"
            }
          ],
          "source": "cna@vuldb.com",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "AC10U",
                "vendor": "Tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.06.49_multi_TDE01"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D1C36BB3-509E-4120-B2EC-F4D061A71F2A",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BFF286BB-A1D3-4E51-AB31-B5A531A8B440",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "es",
            "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC10U 15.03.06.49_multi_TDE01. Ha sido declarada cr\u00edtica. La funci\u00f3n fromDhcpListClient es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento page/listN conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. La explotaci\u00f3n ha sido divulgada al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-252133. NOTA: Se contact\u00f3 primeramente con proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
          }
        ],
        "id": "CVE-2024-0928",
        "lastModified": "2026-06-17T06:54:35.220",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "MULTIPLE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 6.4,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 3.4,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-0928",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-26T20:40:16.864820Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-01-26T16:15:21.707",
        "references": [
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromDhcpListClient_1.md"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required",
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?ctiid.252133"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required",
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?id.252133"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromDhcpListClient_1.md"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Permissions Required",
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?ctiid.252133"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Permissions Required",
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?id.252133"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-121"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T19:00:07+00:00",
      "cve": "CVE-2024-0928",
      "id": "CVE-2024-0928",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Tenda AC10U fromDhcpListClient stack-based overflow",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-0928.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:18:18.976Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "vdb-entry",
                  "technical-description",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?id.252133"
              },
              {
                "tags": [
                  "signature",
                  "permissions-required",
                  "x_transferred"
                ],
                "url": "https://vuldb.com/?ctiid.252133"
              },
              {
                "tags": [
                  "exploit",
                  "x_transferred"
                ],
                "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromDhcpListClient_1.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-0928",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-26T20:40:16.864820Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T21:19:12.275Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AC10U",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "15.03.06.49_multi_TDE01"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "chenjun ma (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the function fromDhcpListClient. The manipulation of the argument page/listN leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "In Tenda AC10U 15.03.06.49_multi_TDE01 wurde eine kritische Schwachstelle ausgemacht. Dabei geht es um die Funktion fromDhcpListClient. Mit der Manipulation des Arguments page/listN mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5.8,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121 Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-26T15:31:03.551Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.252133"
            },
            {
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.252133"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/fromDhcpListClient_1.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-01-26T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-01-26T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-01-26T09:26:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda AC10U fromDhcpListClient stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-0928",
        "datePublished": "2024-01-26T15:31:03.551Z",
        "dateReserved": "2024-01-26T08:21:32.378Z",
        "dateUpdated": "2025-06-17T21:19:31.739Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…