GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2023-6374 (GCVE-0-2023-6374)

Vulnerability from cvelistv5 – Published: 2024-01-30 09:00 – Updated: 2025-06-09 18:35
VLAI
Summary
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-02-06 05:00 UTC
CWE
  • CWE-294 - Authentication Bypass by Capture-replay
References
Impacted products
Vendor Product Version CPE status
Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 Affected: All serial numbers
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:28:21.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-019_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU99497477"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6374",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-06T05:00:26.339109Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-09T18:35:44.426Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC WS Series WS0-GETH00200",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All serial numbers"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules."
            }
          ],
          "value": "Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-294",
              "description": "CWE-294 Authentication Bypass by Capture-replay",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-31T08:19:20.707Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-019_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU99497477"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-6374",
    "datePublished": "2024-01-30T09:00:14.800Z",
    "dateReserved": "2023-11-29T00:52:59.717Z",
    "dateUpdated": "2025-06-09T18:35:44.426Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-6374",
      "date": "2026-09-15",
      "epss": "0.00755",
      "percentile": "0.53204"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mitsubishielectric:melsec_ws0-geth00200_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"31C1CF5D-1E46-4E97-85D2-C92C40D1EADF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mitsubishielectric:melsec_ws0-geth00200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2309DB7C-07CA-4821-A7A2-F461652E62C8\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad de omisi\\u00f3n de autenticaci\\u00f3n mediante Capture-replay en Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200, todos los n\\u00fameros de serie permite a un atacante remoto no autenticado omitir la autenticaci\\u00f3n mediante un ataque de Capture-replay e iniciar sesi\\u00f3n ilegalmente en el m\\u00f3dulo afectado. Como resultado, el atacante remoto que ha iniciado sesi\\u00f3n ilegalmente puede revelar o alterar los programas y par\\u00e1metros de los m\\u00f3dulos.\"}]",
      "id": "CVE-2023-6374",
      "lastModified": "2024-11-21T08:43:43.890",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 5.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2024-01-30T09:15:47.520",
      "references": "[{\"url\": \"https://jvn.jp/vu/JVNVU99497477\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-03\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-019_en.pdf\", \"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU99497477\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-019_en.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-294\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-6374\",\"sourceIdentifier\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"published\":\"2024-01-30T09:15:47.520\",\"lastModified\":\"2026-06-17T06:50:38.030\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n mediante Capture-replay en Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200, todos los n\u00fameros de serie permite a un atacante remoto no autenticado omitir la autenticaci\u00f3n mediante un ataque de Capture-replay e iniciar sesi\u00f3n ilegalmente en el m\u00f3dulo afectado. Como resultado, el atacante remoto que ha iniciado sesi\u00f3n ilegalmente puede revelar o alterar los programas y par\u00e1metros de los m\u00f3dulos.\"}],\"affected\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"affectedData\":[{\"vendor\":\"Mitsubishi Electric Corporation\",\"product\":\"MELSEC WS Series WS0-GETH00200\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"All serial numbers\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-02-06T05:00:26.339109Z\",\"id\":\"CVE-2023-6374\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-294\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:melsec_ws0-geth00200_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31C1CF5D-1E46-4E97-85D2-C92C40D1EADF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:melsec_ws0-geth00200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2309DB7C-07CA-4821-A7A2-F461652E62C8\"}]}]}],\"references\":[{\"url\":\"https://jvn.jp/vu/JVNVU99497477\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-03\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-019_en.pdf\",\"source\":\"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://jvn.jp/vu/JVNVU99497477\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-019_en.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-29T00:37:19+00:00",
      "cve": "CVE-2023-6374",
      "id": "CVE-2023-6374",
      "initial_release_date": "2023-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2023-6374",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-6374.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"cna\": {\"affected\": [{\"defaultStatus\": \"unaffected\", \"product\": \"MELSEC WS Series WS0-GETH00200\", \"vendor\": \"Mitsubishi Electric Corporation\", \"versions\": [{\"status\": \"affected\", \"version\": \"All serial numbers\"}]}], \"descriptions\": [{\"lang\": \"en\", \"supportingMedia\": [{\"base64\": false, \"type\": \"text/html\", \"value\": \"Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules.\"}], \"value\": \"Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules.\"}], \"impacts\": [{\"capecId\": \"CAPEC-115\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-115 Authentication Bypass\"}]}], \"metrics\": [{\"cvssV3_1\": {\"attackComplexity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"availabilityImpact\": \"NONE\", \"baseScore\": 5.9, \"baseSeverity\": \"MEDIUM\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"scope\": \"UNCHANGED\", \"userInteraction\": \"NONE\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"version\": \"3.1\"}, \"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"problemTypes\": [{\"descriptions\": [{\"cweId\": \"CWE-294\", \"description\": \"CWE-294 Authentication Bypass by Capture-replay\", \"lang\": \"en\", \"type\": \"CWE\"}]}], \"providerMetadata\": {\"orgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"shortName\": \"Mitsubishi\", \"dateUpdated\": \"2024-01-31T08:19:20.707Z\"}, \"references\": [{\"tags\": [\"vendor-advisory\"], \"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-019_en.pdf\"}, {\"tags\": [\"government-resource\"], \"url\": \"https://jvn.jp/vu/JVNVU99497477\"}, {\"tags\": [\"government-resource\"], \"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-03\"}], \"source\": {\"discovery\": \"UNKNOWN\"}, \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}}, \"adp\": [{\"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T08:28:21.738Z\"}, \"title\": \"CVE Program Container\", \"references\": [{\"tags\": [\"vendor-advisory\", \"x_transferred\"], \"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-019_en.pdf\"}, {\"tags\": [\"government-resource\", \"x_transferred\"], \"url\": \"https://jvn.jp/vu/JVNVU99497477\"}, {\"tags\": [\"government-resource\", \"x_transferred\"], \"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-03\"}]}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-6374\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-02-06T05:00:26.339109Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-09T18:35:37.444Z\"}}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-6374\", \"assignerOrgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"Mitsubishi\", \"dateReserved\": \"2023-11-29T00:52:59.717Z\", \"datePublished\": \"2024-01-30T09:00:14.800Z\", \"dateUpdated\": \"2025-06-09T18:35:44.426Z\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…