CVE-2023-5680
Vulnerability from cvelistv5
Published
2024-02-13 14:05
Modified
2024-08-02 08:07
Summary
Cleaning an ECS-enabled cache may cause excessive CPU load
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-5680",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-13T18:02:52.507926Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:28:30.667Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:07:32.499Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "CVE-2023-5680",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://kb.isc.org/docs/cve-2023-5680"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20240503-0005/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "BIND 9",
          "vendor": "ISC",
          "versions": [
            {
              "lessThanOrEqual": "9.11.37-S1",
              "status": "affected",
              "version": "9.11.3-S1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.16.45-S1",
              "status": "affected",
              "version": "9.16.8-S1",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.18.21-S1",
              "status": "affected",
              "version": "9.18.11-S1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "ISC would like to thank Yann Kerherve and Ask Bj\u00f8rn Hansen for bringing this vulnerability to our attention."
        }
      ],
      "datePublic": "2024-02-13T00:00:00Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "If a resolver cache has a very large number of ECS records stored for the same name, the process of cleaning the cache database node for this name can significantly impair query performance. \nThis issue affects BIND 9 versions 9.11.3-S1 through 9.11.37-S1, 9.16.8-S1 through 9.16.45-S1, and 9.18.11-S1 through 9.18.21-S1."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "We are not aware of any active exploits."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "By sending specific queries to a resolver, an attacker can degrade `named`\u0027s query-handling performance. In the worst-case scenario, a resolver can become entirely unresponsive."
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-13T14:05:19.783Z",
        "orgId": "404fd4d2-a609-4245-b543-2c944a302a22",
        "shortName": "isc"
      },
      "references": [
        {
          "name": "CVE-2023-5680",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://kb.isc.org/docs/cve-2023-5680"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20240503-0005/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to the patched release most closely related to your current version of BIND 9: 9.16.48-S1 or 9.18.24-S1."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Cleaning an ECS-enabled cache may cause excessive CPU load",
      "workarounds": [
        {
          "lang": "en",
          "value": "There is no workaround for this issue other than disabling the ECS feature entirely."
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "404fd4d2-a609-4245-b543-2c944a302a22",
    "assignerShortName": "isc",
    "cveId": "CVE-2023-5680",
    "datePublished": "2024-02-13T14:05:19.783Z",
    "dateReserved": "2023-10-20T11:13:31.862Z",
    "dateUpdated": "2024-08-02T08:07:32.499Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-5680\",\"sourceIdentifier\":\"security-officer@isc.org\",\"published\":\"2024-02-13T14:15:45.850\",\"lastModified\":\"2024-11-21T08:42:15.870\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"If a resolver cache has a very large number of ECS records stored for the same name, the process of cleaning the cache database node for this name can significantly impair query performance. \\nThis issue affects BIND 9 versions 9.11.3-S1 through 9.11.37-S1, 9.16.8-S1 through 9.16.45-S1, and 9.18.11-S1 through 9.18.21-S1.\"},{\"lang\":\"es\",\"value\":\"Si un cach\u00e9 de resoluci\u00f3n tiene una gran cantidad de registros ECS almacenados para el mismo nombre, el proceso de limpieza del nodo de la base de datos del cach\u00e9 para este nombre puede afectar significativamente el rendimiento de la consulta. Este problema afecta a las versiones de BIND 9, 9.11.3-S1 a 9.11.37-S1, 9.16.8-S1 a 9.16.45-S1 y 9.18.11-S1 a 9.18.21-S1.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security-officer@isc.org\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.3:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"C2FE13E1-0646-46FC-875B-CB4C34E20101\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.3:s4:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"39995ADF-74CC-4035-ADB2-010F676FCEC7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.4:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"37F4F055-5DE3-45FC-82DE-E17679E7B939\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.5:s3:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"1AA16E51-819C-4A1B-B66E-1C60C1782C0D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.5:s5:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"91533F9F-C0E5-4E84-8A4C-F744F956BF97\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.5:s6:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"46E6A4BD-D69B-4A70-821D-5612DD1315EF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.6:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"8AF9D390-0D5B-4963-A2D3-BF1E7CD95E9D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.7:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"AB2B92F1-6BA8-41CA-9000-E0633462CC28\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.8:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"02CA4635-7DFC-408E-A837-856E0F96CA1B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.12:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"3CABCB08-B838-45F7-AA87-77C6B8767DD0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.21:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"5CC1F26C-4757-4C87-BD8B-2FA456A88C6F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.27:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"582A4948-B64F-45D4-807A-846A85BB6B42\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.29:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"F22E7F6A-0714-480D-ACDF-5027FD6697B2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.35:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"255AEB06-F071-4433-93E5-9436086C1A6D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.11.37:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"EF14D712-5FCF-492F-BE3E-745109E9D6E5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.8:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"288EAD80-574B-4839-9C2C-81D6D088A733\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.11:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"3595F024-F910-4356-8B5B-D478960FF574\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.12:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"1B20F152-D0C3-4F07-83B3-5EA6B116F005\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.13:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"94661BA2-27F8-4FFE-B844-9404F735579D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.14:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"53593603-E2AF-4925-A6E6-109F097A0FF2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.21:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"751E37C2-8BFD-4306-95C1-8C01CE495FA4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.32:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"CC432820-F1A2-4132-A673-2620119553C5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.36:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"F70347F2-6750-4497-B8F4-2036F4F4443A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.16.43:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"A4B53B73-DB81-4AC1-A4E6-89BB305D6514\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.18.11:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"16A7E0D1-35A1-4899-9FF2-14279C137C14\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.18.18:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"0233AEF2-9911-48AE-AE97-F217E3337AAF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:isc:bind:9.18.21:s1:*:*:supported_preview:*:*:*\",\"matchCriteriaId\":\"DFE3AE03-DBB5-4891-8EF2-BF30AA6F66FD\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*\",\"matchCriteriaId\":\"3A756737-1CC4-42C2-A4DF-E1C893B4E2D5\"}]}]}],\"references\":[{\"url\":\"https://kb.isc.org/docs/cve-2023-5680\",\"source\":\"security-officer@isc.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20240503-0005/\",\"source\":\"security-officer@isc.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://kb.isc.org/docs/cve-2023-5680\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20240503-0005/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.