CVE-2023-5149 (GCVE-0-2023-5149)
Vulnerability from cvelistv5
Published
2023-09-25 01:00
Modified
2024-08-02 07:52
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
VLAI Severity ?
EPSS score ?
CWE
- CWE-434 - Unrestricted Upload
Summary
** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. This issue affects some unknown processing of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240245 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.
References
| URL | Tags | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:52:07.574Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.240245"
},
{
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.240245"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-7000_upload_%20userattestation.md"
},
{
"tags": [
"related",
"x_transferred"
],
"url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DAR-7000",
"vendor": "D-Link",
"versions": [
{
"status": "affected",
"version": "20151231"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "analyst",
"value": "llixixioo (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. This issue affects some unknown processing of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240245 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in D-Link DAR-7000 bis 20151231 ausgemacht. Sie wurde als kritisch eingestuft. Davon betroffen ist unbekannter Code der Datei /useratte/userattestation.php. Mittels dem Manipulieren des Arguments web_img mit unbekannten Daten kann eine unrestricted upload-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "CWE-434 Unrestricted Upload",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-24T19:30:25.597Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.240245"
},
{
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.240245"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/llixixi/cve/blob/main/D-LINK-DAR-7000_upload_%20userattestation.md"
},
{
"tags": [
"related"
],
"url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354"
}
],
"tags": [
"unsupported-when-assigned"
],
"timeline": [
{
"lang": "en",
"time": "2023-09-24T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2023-09-24T00:00:00.000Z",
"value": "CVE reserved"
},
{
"lang": "en",
"time": "2023-09-24T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2023-10-14T19:26:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "D-Link DAR-7000 userattestation.php unrestricted upload"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2023-5149",
"datePublished": "2023-09-25T01:00:09.724Z",
"dateReserved": "2023-09-24T15:56:24.556Z",
"dateUpdated": "2024-08-02T07:52:07.574Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2023-5149\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2023-09-25T01:15:19.503\",\"lastModified\":\"2024-11-21T08:41:09.863\",\"vulnStatus\":\"Modified\",\"cveTags\":[{\"sourceIdentifier\":\"cna@vuldb.com\",\"tags\":[\"unsupported-when-assigned\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. This issue affects some unknown processing of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240245 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.\"},{\"lang\":\"es\",\"value\":\"** NO SOPORTADO CUANDO EST\u00c1 ASIGNADO ** ** NO SOPORTADO CUANDO EST\u00c1 ASIGNADO ** Se encontr\u00f3 una vulnerabilidad en D-Link DAR-7000 hasta 20151231. Se calific\u00f3 como cr\u00edtica. Este problema afecta un procesamiento desconocido del archivo /useratte/userattestation.php. La manipulaci\u00f3n del argumento web_img conduce a una carga sin restricciones. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-240245. NOTA: Esta vulnerabilidad solo afecta a productos que ya no son compatibles con el mantenedor. NOTA: Se contact\u00f3 primeramente con el proveedor y se confirm\u00f3 de inmediato que el producto ha llegado al final de su vida \u00fatil. Deber\u00eda retirarse y reemplazarse.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-434\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dlink:dar-7000_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2015-12-31\",\"matchCriteriaId\":\"495BA542-4BC4-42FD-874F-3F7B1EB3E625\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dlink:dar-7000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1500AB3C-D11B-4683-86AC-FEB6AF6AD69F\"}]}]}],\"references\":[{\"url\":\"https://github.com/llixixi/cve/blob/main/D-LINK-DAR-7000_upload_%20userattestation.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.240245\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?id.240245\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://github.com/llixixi/cve/blob/main/D-LINK-DAR-7000_upload_%20userattestation.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10354\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.240245\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?id.240245\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…