Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2023-40732 (GCVE-0-2023-40732)
Vulnerability from cvelistv5
Published
2023-09-12 09:32
Modified
2025-02-27 20:55
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-613 - Insufficient Session Expiration
Summary
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | QMS Automotive |
Version: All versions < V12.39 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:38:51.290Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-40732",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:49:48.425507Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-27T20:55:18.275Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "QMS Automotive",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V12.39"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613: Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:32:32.841Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-40732",
"datePublished": "2023-09-12T09:32:32.841Z",
"dateReserved": "2023-08-21T10:57:08.486Z",
"dateUpdated": "2025-02-27T20:55:18.275Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2023-40732\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-09-12T10:15:29.593\",\"lastModified\":\"2024-11-21T08:20:02.943\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en QMS Automotive (todas las versiones \u0026lt; V12.39). El m\u00f3dulo QMS.Mobile la aplicaci\u00f3n afectada no invalida el token de sesi\u00f3n al cerrar sesi\u00f3n. Esto podr\u00eda permitir a un atacante realizar ataques de secuestro de sesi\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N\",\"baseScore\":3.9,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.3,\"impactScore\":2.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N\",\"baseScore\":3.9,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.3,\"impactScore\":2.5}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-613\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:qms_automotive:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.39\",\"matchCriteriaId\":\"17162BBB-9C4B-4347-B2F6-F8E40D67C954\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"cna\": {\"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-09-12T09:32:32.841Z\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.\"}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"QMS Automotive\", \"versions\": [{\"version\": \"All versions \u003c V12.39\", \"status\": \"affected\"}], \"defaultStatus\": \"unknown\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C\", \"baseScore\": 3.9, \"baseSeverity\": \"LOW\"}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"cweId\": \"CWE-613\", \"description\": \"CWE-613: Insufficient Session Expiration\", \"type\": \"CWE\"}]}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf\"}]}, \"adp\": [{\"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T18:38:51.290Z\"}, \"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf\", \"tags\": [\"x_transferred\"]}]}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-40732\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-26T21:49:48.425507Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-26T20:37:28.653Z\"}}]}",
"cveMetadata": "{\"cveId\": \"CVE-2023-40732\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"siemens\", \"dateReserved\": \"2023-08-21T10:57:08.486Z\", \"datePublished\": \"2023-09-12T09:32:32.841Z\", \"dateUpdated\": \"2025-02-27T20:55:18.275Z\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
ghsa-q6jw-jggw-87g5
Vulnerability from github
Published
2023-09-14 18:32
Modified
2024-04-04 07:40
Severity ?
VLAI Severity ?
Details
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.
{
"affected": [],
"aliases": [
"CVE-2023-40732"
],
"database_specific": {
"cwe_ids": [
"CWE-613"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-09-12T10:15:29Z",
"severity": "LOW"
},
"details": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.",
"id": "GHSA-q6jw-jggw-87g5",
"modified": "2024-04-04T07:40:44Z",
"published": "2023-09-14T18:32:40Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-40732"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"type": "CVSS_V3"
}
]
}
icsa-23-257-03
Vulnerability from csaf_cisa
Published
2023-09-12 00:00
Modified
2025-05-06 06:00
Summary
Siemans QMS Automotive
Notes
Summary
QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition.
Siemens has released an update for QMS Automotive and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition. \n\nSiemens has released an update for QMS Automotive and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-147266.json"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-147266.html"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-147266.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-257-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-257-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-257-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-257-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemans QMS Automotive",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-257-03",
"initial_release_date": "2023-09-12T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-09-12T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.39",
"product": {
"name": "QMS Automotive",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "QMS Automotive"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-43958",
"cwe": {
"id": "CWE-256",
"name": "Plaintext Storage of a Password"
},
"notes": [
{
"category": "summary",
"text": "User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-43958"
},
{
"cve": "CVE-2023-40724",
"cwe": {
"id": "CWE-316",
"name": "Cleartext Storage of Sensitive Information in Memory"
},
"notes": [
{
"category": "summary",
"text": "User credentials are found in memory as plaintext. An attacker could perform a memory dump, and get access to credentials, and use it for impersonation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40724"
},
{
"cve": "CVE-2023-40725",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application returns inconsistent error messages in response to invalid user credentials during login session. This allows an attacker to enumerate usernames, and identify valid usernames.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40725"
},
{
"cve": "CVE-2023-40726",
"cwe": {
"id": "CWE-550",
"name": "Server-generated Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application server responds with sensitive information about the server. This could allow an attacker to directly access the database.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40726"
},
{
"cve": "CVE-2023-40727",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application uses weak outdated application signing mechanism. This could allow an attacker to tamper the application code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40727"
},
{
"cve": "CVE-2023-40728",
"cwe": {
"id": "CWE-922",
"name": "Insecure Storage of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application stores sensitive application data in an external insecure storage. This could allow an attacker to alter content, leading to arbitrary code execution or denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40728"
},
{
"cve": "CVE-2023-40729",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application lacks security control to prevent unencrypted communication without HTTPS. An attacker who managed to gain machine-in-the-middle position could manipulate, or steal confidential information.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40729"
},
{
"cve": "CVE-2023-40730",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application lacks sufficient authorization checks. This could allow an attacker to access confidential information, perform administrative functions, or lead to a denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40730"
},
{
"cve": "CVE-2023-40731",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40731"
},
{
"cve": "CVE-2023-40732",
"cwe": {
"id": "CWE-613",
"name": "Insufficient Session Expiration"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40732"
}
]
}
ICSA-23-257-03
Vulnerability from csaf_cisa
Published
2023-09-12 00:00
Modified
2025-05-06 06:00
Summary
Siemans QMS Automotive
Notes
Summary
QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition.
Siemens has released an update for QMS Automotive and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "QMS Automotive before V12.39 contains multiple vulnerabilities that could allow an attacker to perform malicious code injection, information disclosure or lead to a denial of service condition. \n\nSiemens has released an update for QMS Automotive and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-147266.json"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-147266.html"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
},
{
"category": "self",
"summary": "SSA-147266: Multiple Vulnerabilities in QMS Automotive before V12.39 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-147266.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-257-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-257-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-257-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-257-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemans QMS Automotive",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-257-03",
"initial_release_date": "2023-09-12T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-09-12T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV12.39",
"product": {
"name": "QMS Automotive",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "QMS Automotive"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-43958",
"cwe": {
"id": "CWE-256",
"name": "Plaintext Storage of a Password"
},
"notes": [
{
"category": "summary",
"text": "User credentials are stored in plaintext in the database without any hashing mechanism. This could allow an attacker to gain access to credentials and impersonate other users.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:U/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-43958"
},
{
"cve": "CVE-2023-40724",
"cwe": {
"id": "CWE-316",
"name": "Cleartext Storage of Sensitive Information in Memory"
},
"notes": [
{
"category": "summary",
"text": "User credentials are found in memory as plaintext. An attacker could perform a memory dump, and get access to credentials, and use it for impersonation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40724"
},
{
"cve": "CVE-2023-40725",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application returns inconsistent error messages in response to invalid user credentials during login session. This allows an attacker to enumerate usernames, and identify valid usernames.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.0,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40725"
},
{
"cve": "CVE-2023-40726",
"cwe": {
"id": "CWE-550",
"name": "Server-generated Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application server responds with sensitive information about the server. This could allow an attacker to directly access the database.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40726"
},
{
"cve": "CVE-2023-40727",
"cwe": {
"id": "CWE-347",
"name": "Improper Verification of Cryptographic Signature"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application uses weak outdated application signing mechanism. This could allow an attacker to tamper the application code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40727"
},
{
"cve": "CVE-2023-40728",
"cwe": {
"id": "CWE-922",
"name": "Insecure Storage of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application stores sensitive application data in an external insecure storage. This could allow an attacker to alter content, leading to arbitrary code execution or denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40728"
},
{
"cve": "CVE-2023-40729",
"cwe": {
"id": "CWE-319",
"name": "Cleartext Transmission of Sensitive Information"
},
"notes": [
{
"category": "summary",
"text": "The affected application lacks security control to prevent unencrypted communication without HTTPS. An attacker who managed to gain machine-in-the-middle position could manipulate, or steal confidential information.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40729"
},
{
"cve": "CVE-2023-40730",
"cwe": {
"id": "CWE-284",
"name": "Improper Access Control"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application lacks sufficient authorization checks. This could allow an attacker to access confidential information, perform administrative functions, or lead to a denial-of-service condition.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40730"
},
{
"cve": "CVE-2023-40731",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"category": "summary",
"text": "The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40731"
},
{
"cve": "CVE-2023-40732",
"cwe": {
"id": "CWE-613",
"name": "Insufficient Session Expiration"
},
"notes": [
{
"category": "summary",
"text": "The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V12.39 or later version. The patch is available upon request from customer support",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-40732"
}
]
}
gsd-2023-40732
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-40732",
"id": "GSD-2023-40732"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-40732"
],
"details": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.",
"id": "GSD-2023-40732",
"modified": "2023-12-13T01:20:44.079512Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2023-40732",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QMS Automotive",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V12.39"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 3.9,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-613",
"lang": "eng",
"value": "CWE-613: Insufficient Session Expiration"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:qms_automotive:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "12.39",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2023-40732"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-613"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.9,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.3,
"impactScore": 2.5
}
},
"lastModifiedDate": "2023-09-14T16:49Z",
"publishedDate": "2023-09-12T10:15Z"
}
}
}
fkie_cve-2023-40732
Vulnerability from fkie_nvd
Published
2023-09-12 10:15
Modified
2024-11-21 08:20
Severity ?
3.9 (Low) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N
3.9 (Low) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N
3.9 (Low) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N
Summary
A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | qms_automotive | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:qms_automotive:*:*:*:*:*:*:*:*",
"matchCriteriaId": "17162BBB-9C4B-4347-B2F6-F8E40D67C954",
"versionEndExcluding": "12.39",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in QMS Automotive (All versions \u003c V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en QMS Automotive (todas las versiones \u0026lt; V12.39). El m\u00f3dulo QMS.Mobile la aplicaci\u00f3n afectada no invalida el token de sesi\u00f3n al cerrar sesi\u00f3n. Esto podr\u00eda permitir a un atacante realizar ataques de secuestro de sesi\u00f3n."
}
],
"id": "CVE-2023-40732",
"lastModified": "2024-11-21T08:20:02.943",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.9,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.3,
"impactScore": 2.5,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.9,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.3,
"impactScore": 2.5,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-09-12T10:15:29.593",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-147266.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-613"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
CERTFR-2023-AVI-0733
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMIT Simulation Platform toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Teamcenter Visualization versions 14.1.x antérieures à 14.1.0.11 | ||
| Siemens | N/A | PSS(R)ODMS V13.0 toutes versions | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller V2 versions antérieures à 21.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Parasolid versions 36.0.x antérieures à 36.0.142 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Teamcenter Visualization versions 14.2.x antérieures à 14.2.0.6 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Parasolid versions 35.0.x antérieures à 35.0.253 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Parasolid versions 34.1.x antérieures à 34.1.258 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | PSS(R)CAPE versions 14.x antérieures à 14.2023-08-23 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | PSS(R)ODMS versions 13.1.x antérieures à 13.1.12.1 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Teamcenter Visualization versions 14.3.x antérieures à 14.3.0.1 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) versions antérieures à 2.2 | ||
| Siemens | N/A | Teamcenter Visualization versions 13.3.x antérieures à 13.3.0.12 | ||
| Siemens | N/A | RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | PSS(R)E versions 34.x antérieures à 34.9.6 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) versions antérieures à 2.2 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC WinCC OA versions 3.19.x antérieures à 3.19 P006 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | PSS(R)CAPE versions 15.x antérieures à 15.0.22 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) versions antérieures à 21.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | Parasolid versions 35.1.x antérieures à 35.1.184 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | PSS(R)E V35 toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | JT2Go versions antérieures à 14.3.0.1 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | QMS Automotive versions antérieures à 12.39 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0) versions antérieures à 3.0.3 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0) versions antérieures à 2.9.7 | ||
| Siemens | N/A | RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0) versions antérieures à 1.0.212N | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0) versions antérieures à 3.0.3 |
References
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "RUGGEDCOM APE1808 ELAN CC (6GK6015-0AL20-0GP1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMIT Simulation Platform toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517H-3 PN (6ES7517-3HP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DJ01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.1.x ant\u00e9rieures \u00e0 14.1.0.11",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)ODMS V13.0 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 ADM CC (6GK6015-0AL20-0GL1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518F-4 PN/DP (6ES7518-4FP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller V2 versions ant\u00e9rieures \u00e0 21.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TL03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511T-1 PN (6ES7511-1TK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions 36.0.x ant\u00e9rieures \u00e0 36.0.142",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FP03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S1 (6GK6015-0AL20-1AB0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UL03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP (6ES7517-3UP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S3 CC (6GK6015-0AL20-1AD1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP (6ES7518-4UP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S5 CC (6GK6015-0AL20-1AF1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK02-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.2.x ant\u00e9rieures \u00e0 14.2.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 CLOUDCONNECT (6GK6015-0AL20-0GM0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL (6AG2510-1DJ01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions 35.0.x ant\u00e9rieures \u00e0 35.0.253",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions 34.1.x ant\u00e9rieures \u00e0 34.1.258",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AL03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL (6AG2516-3AN02-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S3 (6GK6015-0AL20-1AD0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517T-3 PN/DP (6ES7517-3TP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK (6ES7518-4FP00-3AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN (6ES7516-2GN00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1514SPT F-2 PN (6ES7514-2WN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1518F-4 PN/DP (6AG1518-4FP00-4AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516T-3 PN/DP (6ES7516-3TN00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 CKP CC (6GK6015-0AL20-0GK1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-P CC (6GK6015-0AL20-1AA1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S5 (6GK6015-0AL20-1AF0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 CKP (6GK6015-0AL20-0GK0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL (6AG2515-2RM00-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518HF-4 PN (6ES7518-4JP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)CAPE versions 14.x ant\u00e9rieures \u00e0 14.2023-08-23",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RM00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AL01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL (6AG2516-3AN01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 ADM (6GK6015-0AL20-0GL0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1518-4 PN/DP (6AG1518-4AP00-4AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)ODMS versions 13.1.x ant\u00e9rieures \u00e0 13.1.12.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP F-1 PN (6AG1512-1SK01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SK03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL (6AG2511-1AK02-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512C-1 PN (6ES7512-1CK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FL03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516F-3 PN/DP (6ES7516-3FN01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.3.x ant\u00e9rieures \u00e0 14.3.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515-2 PN (6ES7515-2AM02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1510SP-1 PN (6ES7510-1DK03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP F-1 PN (6AG1510-1SJ01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 CLOUDCONNECT CC (6GK6015-0AL20-0GM1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515F-2 PN (6AG1515-2FM02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518-4 PN/DP (6ES7518-4AP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AP03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TM01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL (6AG2510-1SJ01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516-3 PN/DP (6ES7516-3AN01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN (6ES7516-2PN00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN (6ES7513-2GL00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP (6ES7516-3UN00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 SAM-L (6GK6015-0AL20-0GN0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511-1 PN (6ES7511-1AK02-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513R-1 PN (6ES7513-1RL00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP-1 PN (6AG1512-1DK01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512SP F-1 PN (6ES7512-1SM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 SAM-L CC (6GK6015-0AL20-0GN1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) versions ant\u00e9rieures \u00e0 2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 13.3.x ant\u00e9rieures \u00e0 13.3.0.12",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808W10 CC (6GK6015-0AL20-0GJ1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)E versions 34.x ant\u00e9rieures \u00e0 34.9.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511F-1 PN (6ES7511-1FK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1517F-3 PN/DP (6ES7517-3FP00-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL (6AG2515-2FM01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1517H-3 PN (6AG1517-3HP00-4AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) versions ant\u00e9rieures \u00e0 2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513-1 PN (6ES7513-1AM03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK02-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA versions 3.19.x ant\u00e9rieures \u00e0 3.19 P006",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)CAPE versions 15.x ant\u00e9rieures \u00e0 15.0.22",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) versions ant\u00e9rieures \u00e0 21.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808W10 (6GK6015-0AL20-0GJ0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN (6ES7513-2PL00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL (6AG2511-1AK01-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515F-2 PN (6ES7515-2FM01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions 35.1.x ant\u00e9rieures \u00e0 35.1.184",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515T-2 PN (6ES7515-2TN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1518HF-4 PN (6AG1518-4JP00-4AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513F-1 PN (6AG1513-1FL02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1510SP-1 PN (6AG1510-1DJ01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)E V35 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1510SP F-1 PN (6ES7510-1SJ01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL (6AG2512-1DK01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511F-1 PN (6AG1511-1FK02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL (6AG2516-3FN02-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515R-2 PN (6AG1515-2RM00-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511C-1 PN (6ES7511-1CK00-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL (6AG2512-1SK01-1AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-S1 CC (6GK6015-0AL20-1AB1) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1511TF-1 PN (6ES7511-1UK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1514SPT-2 PN (6ES7514-2VN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516-3 PN/DP (6AG1516-3AN02-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 14.3.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515R-2 PN (6ES7515-2RN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "QMS Automotive versions ant\u00e9rieures \u00e0 12.39",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1514SP-2 PN (6ES7514-2DN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1516F-3 PN/DP (6AG1516-3FN01-2AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 ELAN (6GK6015-0AL20-0GP0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL (6AG2515-2FM02-4AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1513F-1 PN (6ES7513-1FL01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1511-1 PN (6AG1511-1AK01-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1500 CPU 1513-1 PN (6AG1513-1AL02-7AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1515TF-2 PN (6ES7515-2UM01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1512SP-1 PN (6ES7512-1DK01-0AB0) versions ant\u00e9rieures \u00e0 2.9.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808CLA-P (6GK6015-0AL20-1AA0) versions ant\u00e9rieures \u00e0 1.0.212N",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1514SP F-2 PN (6ES7514-2SN03-0AB0) versions ant\u00e9rieures \u00e0 3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-40728",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40728"
},
{
"name": "CVE-2022-35894",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35894"
},
{
"name": "CVE-2022-32953",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32953"
},
{
"name": "CVE-2023-40724",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40724"
},
{
"name": "CVE-2023-27373",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27373"
},
{
"name": "CVE-2023-3935",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3935"
},
{
"name": "CVE-2023-38072",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38072"
},
{
"name": "CVE-2023-38075",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38075"
},
{
"name": "CVE-2022-30283",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30283"
},
{
"name": "CVE-2023-38073",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38073"
},
{
"name": "CVE-2023-40730",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40730"
},
{
"name": "CVE-2023-24932",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24932"
},
{
"name": "CVE-2023-40732",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40732"
},
{
"name": "CVE-2022-32475",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32475"
},
{
"name": "CVE-2022-29275",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29275"
},
{
"name": "CVE-2022-35893",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35893"
},
{
"name": "CVE-2022-32954",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32954"
},
{
"name": "CVE-2023-40725",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40725"
},
{
"name": "CVE-2021-38578",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-38578"
},
{
"name": "CVE-2022-32469",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32469"
},
{
"name": "CVE-2022-43958",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43958"
},
{
"name": "CVE-2023-41033",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41033"
},
{
"name": "CVE-2022-27405",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27405"
},
{
"name": "CVE-2022-40982",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40982"
},
{
"name": "CVE-2023-38071",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38071"
},
{
"name": "CVE-2022-35895",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35895"
},
{
"name": "CVE-2023-40726",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40726"
},
{
"name": "CVE-2022-24350",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24350"
},
{
"name": "CVE-2023-38070",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38070"
},
{
"name": "CVE-2022-32470",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32470"
},
{
"name": "CVE-2023-38074",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38074"
},
{
"name": "CVE-2022-35896",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35896"
},
{
"name": "CVE-2022-36338",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36338"
},
{
"name": "CVE-2017-5715",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-5715"
},
{
"name": "CVE-2023-28831",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28831"
},
{
"name": "CVE-2022-32477",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32477"
},
{
"name": "CVE-2023-40727",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40727"
},
{
"name": "CVE-2022-32471",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32471"
},
{
"name": "CVE-2023-40731",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40731"
},
{
"name": "CVE-2023-31041",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-31041"
},
{
"name": "CVE-2023-40729",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-40729"
},
{
"name": "CVE-2022-30772",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30772"
},
{
"name": "CVE-2023-38076",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38076"
},
{
"name": "CVE-2023-41032",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41032"
},
{
"name": "CVE-2022-24351",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24351"
}
],
"initial_release_date": "2023-09-12T00:00:00",
"last_revision_date": "2023-09-12T00:00:00",
"links": [],
"reference": "CERTFR-2023-AVI-0733",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-09-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Certaines d\u0027entre elles\npermettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire\n\u00e0 distance, un d\u00e9ni de service \u00e0 distance et une \u00e9l\u00e9vation de\nprivil\u00e8ges.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-278349 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-981975.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-147266 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-147266.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-240541 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-957369.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-957369 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-240541.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-190839 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-190839.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-981975 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-711309.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-711309 du 12 septembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-278349.html"
}
]
}
cnvd-2023-71216
Vulnerability from cnvd
Title
Siemens QMS Automotive代码问题漏洞(CNVD-2023-71216)
Description
Siemens QMS Automotive是德国西门子(Siemens)公司的一个汽车行业的质量管理系统。
Siemens QMS Automotive存在代码问题漏洞,该漏洞源于受影响应用程序的QMS.Mobile模块不会在注销时使会话令牌失效。攻击者可利用该漏洞执行会话劫持攻击。
Severity
低
VLAI Severity ?
Patch Name
Siemens QMS Automotive代码问题漏洞(CNVD-2023-71216)的补丁
Patch Description
Siemens QMS Automotive是德国西门子(Siemens)公司的一个汽车行业的质量管理系统。
Siemens QMS Automotive存在代码问题漏洞,该漏洞源于受影响应用程序的QMS.Mobile模块不会在注销时使会话令牌失效。攻击者可利用该漏洞执行会话劫持攻击。目前,供应商发布了安全公告及相关补丁信息,修复了此漏洞。
Formal description
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-147266.html
Reference
https://cert-portal.siemens.com/productcert/html/ssa-147266.html
Impacted products
| Name | Siemens QMS Automotive < V12.39 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2023-40732"
}
},
"description": "Siemens QMS Automotive\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u6c7d\u8f66\u884c\u4e1a\u7684\u8d28\u91cf\u7ba1\u7406\u7cfb\u7edf\u3002\n\nSiemens QMS Automotive\u5b58\u5728\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u53d7\u5f71\u54cd\u5e94\u7528\u7a0b\u5e8f\u7684QMS.Mobile\u6a21\u5757\u4e0d\u4f1a\u5728\u6ce8\u9500\u65f6\u4f7f\u4f1a\u8bdd\u4ee4\u724c\u5931\u6548\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884c\u4f1a\u8bdd\u52ab\u6301\u653b\u51fb\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-147266.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2023-71216",
"openTime": "2023-09-22",
"patchDescription": "Siemens QMS Automotive\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u4e2a\u6c7d\u8f66\u884c\u4e1a\u7684\u8d28\u91cf\u7ba1\u7406\u7cfb\u7edf\u3002\r\n\r\nSiemens QMS Automotive\u5b58\u5728\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u53d7\u5f71\u54cd\u5e94\u7528\u7a0b\u5e8f\u7684QMS.Mobile\u6a21\u5757\u4e0d\u4f1a\u5728\u6ce8\u9500\u65f6\u4f7f\u4f1a\u8bdd\u4ee4\u724c\u5931\u6548\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u6267\u884c\u4f1a\u8bdd\u52ab\u6301\u653b\u51fb\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens QMS Automotive\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\uff08CNVD-2023-71216\uff09\u7684\u8865\u4e01",
"products": {
"product": "Siemens QMS Automotive \u003c V12.39"
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-147266.html",
"serverity": "\u4f4e",
"submitTime": "2023-09-14",
"title": "Siemens QMS Automotive\u4ee3\u7801\u95ee\u9898\u6f0f\u6d1e\uff08CNVD-2023-71216\uff09"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…