CVE-2023-31408 (GCVE-0-2023-31408)
Vulnerability from cvelistv5 – Published: 2023-05-15 10:55 – Updated: 2026-06-01 07:26
VLAI
EPSS
VEX
Summary
Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with
Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote
attacker to potentially steal user credentials that are stored in the user’s browsers local storage via
cross-site-scripting attacks.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-23 17:32 UTC
CWE
- CWE-312 - (Cleartext Storage of Sensitive Information)
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://sick.com/psirt | issue-tracking |
| https://sick.com/.well-known/csaf/white/2023/sca-… | vendor-advisory |
| https://sick.com/.well-known/csaf/white/2023/sca-… | x_csaf |
Impacted products
7 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| SICK AG | SICK FTMG-ESD15AXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
guessed | |
| SICK AG | SICK FTMG-ESD20AXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
guessed | |
| SICK AG | SICK FTMG-ESD25AXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
guessed | |
| SICK AG | SICK FTMG-ESN40SXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
guessed | |
| SICK AG | SICK FTMG-ESN50SXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
guessed | |
| SICK AG | SICK FTMG-ESR40SXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
guessed | |
| SICK AG | SICK FTMG-ESR50SXX AIR FLOW SENSOR |
Affected:
all firmware versions
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:53:30.909Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-31408",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-23T17:32:58.739667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-23T17:33:18.976Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD15AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD20AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD25AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with\nPartnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote\nattacker to potentially steal user credentials that are stored in the user\u2019s browsers local storage via\ncross-site-scripting attacks."
}
],
"value": "Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with\nPartnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote\nattacker to potentially steal user credentials that are stored in the user\u2019s browsers local storage via\ncross-site-scripting attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 (Cleartext Storage of Sensitive Information)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T07:26:36.816Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
}
],
"source": {
"discovery": "INTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please make sure that you apply general security practices when operating the SICK FTMg\nlike network segmentation. The following General Security Practices and Operating Guidelines could\nmitigate the associated security risk."
}
],
"value": "Please make sure that you apply general security practices when operating the SICK FTMg\nlike network segmentation. The following General Security Practices and Operating Guidelines could\nmitigate the associated security risk."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-31408",
"datePublished": "2023-05-15T10:55:39.301Z",
"dateReserved": "2023-04-27T18:35:47.417Z",
"dateUpdated": "2026-06-01T07:26:36.816Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-31408",
"date": "2026-09-22",
"epss": "0.00428",
"percentile": "0.36665"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esd20axx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E3882685-8678-47E4-995C-C3F6D9AD5668",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esd20axx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "16AD808F-900B-41EE-B90A-F9D67AAAD6BE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esd25axx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49D930E8-415C-4183-87A1-8D7F44247B67",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esd25axx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "24618A95-328C-47C9-B8EF-B4DF6E65D68E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esn40sxx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1DCC9C0B-7CCE-44E5-B25D-67BF971B4541",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esn40sxx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "290B016B-20B7-40C1-B825-6ED4774C4861",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esn50sxx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E23D6018-1DFB-4516-82C9-3A3B09C2CBF9",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esn50sxx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1B113D9E-8E61-4F9C-9E5B-2030EEFB133B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esr50sxx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "77F2683F-B1B5-4033-97D4-ADF77B6B50E8",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esr50sxx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A02547D3-5E40-41B3-A7B4-D63F60A5F80B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esr40sxx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9075A02A-C627-43DA-ACF7-776197B518C5",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esr40sxx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7B887993-18A8-493F-97A1-A788FBD5A5B9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esd15axx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E9219CD8-34CE-45A2-904A-E7B1740706C2",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esd15axx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF162AA9-6645-4032-8D29-BAE2D60FBD9B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "\nCleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with\nPartnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote\nattacker to potentially steal user credentials that are stored in the user\u2019s browsers local storage via\ncross-site-scripting attacks.\n\n"
}
],
"id": "CVE-2023-31408",
"lastModified": "2024-11-21T08:01:48.083",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "psirt@sick.de",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-05-15T11:15:09.477",
"references": [
{
"source": "psirt@sick.de",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
},
{
"source": "psirt@sick.de",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"source": "psirt@sick.de",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/psirt"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/psirt"
}
],
"sourceIdentifier": "psirt@sick.de",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "psirt@sick.de",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD15AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD20AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD25AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
}
],
"source": "psirt@sick.de"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esd20axx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E3882685-8678-47E4-995C-C3F6D9AD5668",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esd20axx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "16AD808F-900B-41EE-B90A-F9D67AAAD6BE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esd25axx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49D930E8-415C-4183-87A1-8D7F44247B67",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esd25axx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "24618A95-328C-47C9-B8EF-B4DF6E65D68E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esn40sxx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1DCC9C0B-7CCE-44E5-B25D-67BF971B4541",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esn40sxx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "290B016B-20B7-40C1-B825-6ED4774C4861",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esn50sxx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E23D6018-1DFB-4516-82C9-3A3B09C2CBF9",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esn50sxx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1B113D9E-8E61-4F9C-9E5B-2030EEFB133B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esr50sxx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "77F2683F-B1B5-4033-97D4-ADF77B6B50E8",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esr50sxx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A02547D3-5E40-41B3-A7B4-D63F60A5F80B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esr40sxx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9075A02A-C627-43DA-ACF7-776197B518C5",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esr40sxx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7B887993-18A8-493F-97A1-A788FBD5A5B9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sick:ftmg-esd15axx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E9219CD8-34CE-45A2-904A-E7B1740706C2",
"versionEndExcluding": "2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sick:ftmg-esd15axx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF162AA9-6645-4032-8D29-BAE2D60FBD9B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with\nPartnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote\nattacker to potentially steal user credentials that are stored in the user\u2019s browsers local storage via\ncross-site-scripting attacks."
}
],
"id": "CVE-2023-31408",
"lastModified": "2026-06-17T05:56:52.877",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "psirt@sick.de",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-31408",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-23T17:32:58.739667Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-05-15T11:15:09.477",
"references": [
{
"source": "psirt@sick.de",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
},
{
"source": "psirt@sick.de",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"source": "psirt@sick.de",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/psirt"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://sick.com/psirt"
}
],
"sourceIdentifier": "psirt@sick.de",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "psirt@sick.de",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-06-01T16:03:08+00:00",
"cve": "CVE-2023-31408",
"id": "CVE-2023-31408",
"initial_release_date": "2023-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2023-31408",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-31408.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:53:30.909Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"issue-tracking",
"x_transferred"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"tags": [
"x_csaf",
"x_transferred"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-31408",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-23T17:32:58.739667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-23T17:33:07.364Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD15AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD20AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESD25AXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESN50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR40SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
},
{
"defaultStatus": "affected",
"product": "SICK FTMG-ESR50SXX AIR FLOW SENSOR",
"vendor": "SICK AG",
"versions": [
{
"status": "affected",
"version": "all firmware versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with\nPartnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote\nattacker to potentially steal user credentials that are stored in the user\u2019s browsers local storage via\ncross-site-scripting attacks."
}
],
"value": "Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with\nPartnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote\nattacker to potentially steal user credentials that are stored in the user\u2019s browsers local storage via\ncross-site-scripting attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312 (Cleartext Storage of Sensitive Information)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-01T07:26:36.816Z",
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"shortName": "SICK AG"
},
"references": [
{
"tags": [
"issue-tracking"
],
"url": "https://sick.com/psirt"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.pdf"
},
{
"tags": [
"x_csaf"
],
"url": "https://sick.com/.well-known/csaf/white/2023/sca-2023-0004.json"
}
],
"source": {
"discovery": "INTERNAL"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Please make sure that you apply general security practices when operating the SICK FTMg\nlike network segmentation. The following General Security Practices and Operating Guidelines could\nmitigate the associated security risk."
}
],
"value": "Please make sure that you apply general security practices when operating the SICK FTMg\nlike network segmentation. The following General Security Practices and Operating Guidelines could\nmitigate the associated security risk."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
"assignerShortName": "SICK AG",
"cveId": "CVE-2023-31408",
"datePublished": "2023-05-15T10:55:39.301Z",
"dateReserved": "2023-04-27T18:35:47.417Z",
"dateUpdated": "2026-06-01T07:26:36.816Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…