CVE-2022-40147 (GCVE-0-2022-40147)
Vulnerability from cvelistv5
Published
2022-10-11 00:00
Modified
2024-08-03 12:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-295 - Improper Certificate Validation
Summary
A vulnerability has been identified in Industrial Edge Management (All versions < V1.5.1). The affected software does not properly validate the server certificate when initiating a TLS connection. This could allow an attacker to spoof a trusted entity by interfering in the communication path between the client and the intended server.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | Industrial Edge Management |
Version: All versions < V1.5.1 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:39.697Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-649853.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Industrial Edge Management",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.5.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Industrial Edge Management (All versions \u003c V1.5.1). The affected software does not properly validate the server certificate when initiating a TLS connection. This could allow an attacker to spoof a trusted entity by interfering in the communication path between the client and the intended server."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295: Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-11T00:00:00",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-649853.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-40147",
"datePublished": "2022-10-11T00:00:00",
"dateReserved": "2022-09-07T00:00:00",
"dateUpdated": "2024-08-03T12:14:39.697Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-40147\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-10-11T11:15:10.417\",\"lastModified\":\"2024-11-21T07:20:58.717\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Industrial Edge Management (All versions \u003c V1.5.1). The affected software does not properly validate the server certificate when initiating a TLS connection. This could allow an attacker to spoof a trusted entity by interfering in the communication path between the client and the intended server.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Industrial Edge Management (Todas las versiones anteriores a V1.5.1). El software afectado no comprueba apropiadamente el certificado del servidor cuando es iniciada una conexi\u00f3n TLS. Esto podr\u00eda permitir a un atacante falsificar una entidad confiable interfiriendo en la ruta de comunicaci\u00f3n entre el cliente y el servidor previsto\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:industrial_edge_management:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.5.1\",\"matchCriteriaId\":\"CF90D278-A614-4A5B-AFD9-94B0EF0F8700\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-649853.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-649853.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…