Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-34659 (GCVE-0-2022-34659)
Vulnerability from cvelistv5
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | Simcenter STAR-CCM+ |
Version: All versions only if the Power-on-Demand public license server is used |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T09:15:15.695Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Simcenter STAR-CCM+", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions only if the Power-on-Demand public license server is used" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:17:55", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-34659", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Simcenter STAR-CCM+", "version": { "version_data": [ { "version_value": "All versions only if the Power-on-Demand public license server is used" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-34659", "datePublished": "2022-08-10T11:17:56", "dateReserved": "2022-06-27T00:00:00", "dateUpdated": "2024-08-03T09:15:15.695Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-34659\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-08-10T12:15:12.143\",\"lastModified\":\"2024-11-21T07:09:55.463\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Simcenter STAR-CCM+ (Todas las versiones s\u00f3lo si es usado el servidor de licencias p\u00fablicas Power-on-Demand). Las aplicaciones afectadas exponen el usuario, el host y el nombre de pantalla de los usuarios, cuando se usa el servidor p\u00fablico de licencias. Esto podr\u00eda permitir a un atacante recuperar esta informaci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simcenter_star-ccm\\\\+_viewer:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3C21E9FD-B467-43FF-8ECE-DDA5FC3521D4\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}" } }
gsd-2022-34659
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-34659", "description": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.", "id": "GSD-2022-34659" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-34659" ], "details": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.", "id": "GSD-2022-34659", "modified": "2023-12-13T01:19:19.280428Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-34659", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Simcenter STAR-CCM+", "version": { "version_data": [ { "version_value": "All versions only if the Power-on-Demand public license server is used" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simcenter_star-ccm\\+_viewer:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-34659" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-200" } ] } ] }, "references": { "reference_data": [ { "name": "N/A", "refsource": "CONFIRM", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-08-16T15:58Z", "publishedDate": "2022-08-10T12:15Z" } } }
ghsa-7jc3-54w2-9q65
Vulnerability from github
A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.
{ "affected": [], "aliases": [ "CVE-2022-34659" ], "database_specific": { "cwe_ids": [ "CWE-200" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-08-10T12:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.", "id": "GHSA-7jc3-54w2-9q65", "modified": "2022-08-17T00:00:23Z", "published": "2022-08-11T00:00:38Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-34659" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "type": "CVSS_V3" } ] }
icsa-22-223-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Simcenter STAR-CCM+ contains an information disclosure vulnerability\nwhen using the Power-on-Demand public license server. An attacker\ncould access a system\u0027s host, user, and display name. Siemens is\npreparing updates and recommends specific countermeasures for products\nwhere updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-555707: Information Disclosure Vulnerability in Simcenter STAR-CCM+ - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-555707.json" }, { "category": "self", "summary": "SSA-555707: Information Disclosure Vulnerability in Simcenter STAR-CCM+ - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-555707.txt" }, { "category": "self", "summary": "SSA-555707: Information Disclosure Vulnerability in Simcenter STAR-CCM+ - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-22-223-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-223-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-223-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Simcenter STAR-CCM+", "tracking": { "current_release_date": "2022-08-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-223-01", "initial_release_date": "2022-08-09T00:00:00.000000Z", "revision_history": [ { "date": "2022-08-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All_versions_only_if_the_Power-on-Demand_public_license_server_is_used", "product": { "name": "Simcenter STAR-CCM+", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Simcenter STAR-CCM+" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-34659", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Set the environmental variable STARLICENSEHIDE to 1. This will send\nthe string \"unknown\" for the user, host and display name instead of\nthe real values. The setting is supported since version V8.04 (June\n2013) of Simcenter STAR-CCM+", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid using sensitive or personal data in user, host and display names", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-34659" } ] }
ICSA-22-223-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting this vulnerability to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "Simcenter STAR-CCM+ contains an information disclosure vulnerability\nwhen using the Power-on-Demand public license server. An attacker\ncould access a system\u0027s host, user, and display name. Siemens is\npreparing updates and recommends specific countermeasures for products\nwhere updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect\nnetwork access to devices with appropriate mechanisms. In order to\noperate the devices in a protected IT environment, Siemens recommends\nto configure the environment according to Siemens\u0027 operational\nguidelines for Industrial Security (Download:\nhttps://www.siemens.com/cert/operational-guidelines-industrial-\nsecurity), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found\nat: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-555707: Information Disclosure Vulnerability in Simcenter STAR-CCM+ - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-555707.json" }, { "category": "self", "summary": "SSA-555707: Information Disclosure Vulnerability in Simcenter STAR-CCM+ - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-555707.txt" }, { "category": "self", "summary": "SSA-555707: Information Disclosure Vulnerability in Simcenter STAR-CCM+ - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-22-223-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-223-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-223-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Simcenter STAR-CCM+", "tracking": { "current_release_date": "2022-08-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-223-01", "initial_release_date": "2022-08-09T00:00:00.000000Z", "revision_history": [ { "date": "2022-08-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "All_versions_only_if_the_Power-on-Demand_public_license_server_is_used", "product": { "name": "Simcenter STAR-CCM+", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Simcenter STAR-CCM+" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2022-34659", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "Set the environmental variable STARLICENSEHIDE to 1. This will send\nthe string \"unknown\" for the user, host and display name instead of\nthe real values. The setting is supported since version V8.04 (June\n2013) of Simcenter STAR-CCM+", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid using sensitive or personal data in user, host and display names", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2022-34659" } ] }
CERTFR-2022-AVI-718
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | Teamcenter V12.4 versions antérieures à 12.4.0.15 | ||
Siemens | N/A | CP-8000 (6MF2101-1AB10-0AA0) toutes versions | ||
Siemens | N/A | SCALANCE W-1700 IEEE 802.11ac toutes versions | ||
Siemens | N/A | Soft Starter ES versions antérieures à 16 | ||
Siemens | N/A | Soft Starter ES versions antérieures à 15.1 | ||
Siemens | N/A | SCALANCE XB-200 toutes versions | ||
Siemens | N/A | SCALANCE XR-500 toutes versions | ||
Siemens | N/A | Teamcenter V13.1 versions antérieures à 13.1.0.10 | ||
Siemens | N/A | CP-8021 (6MF2802-1AA00) toutes versions | ||
Siemens | N/A | Simcenter STAR-CCM+ | ||
Siemens | N/A | CP-8022 (6MF2802-2AA00) toutes versions | ||
Siemens | N/A | SCALANCE XC-200 toutes versions | ||
Siemens | N/A | SCALANCE XP-200 toutes versions | ||
Siemens | N/A | SCALANCE XM-400 toutes versions | ||
Siemens | N/A | SCALANCE XF-200BA toutes versions | ||
Siemens | N/A | Teamcenter V13.0 versions antérieures à 13.0.0.10 | ||
Siemens | N/A | CP-8000 (6MF2101-0AB10-0AA0) toutes versions | ||
Siemens | N/A | SCALANCE W-700 IEEE 802.11n toutes versions | ||
Siemens | N/A | SCALANCE M-800 / S615 toutes versions | ||
Siemens | N/A | SIMOCODE ES versions antérieures à 16 | ||
Siemens | N/A | Teamcenter V13.3 versions antérieures à 13.3.0.5 | ||
Siemens | N/A | SCALANCE W-700 IEEE 802.11ax toutes versions | ||
Siemens | N/A | SCALANCE XR-300WG toutes versions | ||
Siemens | N/A | Teamcenter V13.2 versions antérieures à 13.2.0.9 | ||
Siemens | N/A | SIMOCODE ES versions antérieures à 15.1 | ||
Siemens | N/A | Teamcenter V14.0 versions antérieures à 14.0.0.2 | ||
Siemens | N/A | SCALANCE SC-600 versions antérieures à 2.3.1 |
Title | Publication Time | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Teamcenter V12.4 versions ant\u00e9rieures \u00e0 12.4.0.15", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP-8000 (6MF2101-1AB10-0AA0) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W-1700 IEEE 802.11ac toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Soft Starter ES versions ant\u00e9rieures \u00e0 16", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Soft Starter ES versions ant\u00e9rieures \u00e0 15.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XB-200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR-500 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.1 versions ant\u00e9rieures \u00e0 13.1.0.10", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP-8021 (6MF2802-1AA00) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Simcenter STAR-CCM+", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP-8022 (6MF2802-2AA00) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XC-200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XP-200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XM-400 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XF-200BA toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.0 versions ant\u00e9rieures \u00e0 13.0.0.10", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "CP-8000 (6MF2101-0AB10-0AA0) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W-700 IEEE 802.11n toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE M-800 / S615 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMOCODE ES versions ant\u00e9rieures \u00e0 16", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.3 versions ant\u00e9rieures \u00e0 13.3.0.5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W-700 IEEE 802.11ax toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE XR-300WG toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V13.2 versions ant\u00e9rieures \u00e0 13.2.0.9", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMOCODE ES versions ant\u00e9rieures \u00e0 15.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Teamcenter V14.0 versions ant\u00e9rieures \u00e0 14.0.0.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 2.3.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-46304", "url": "https://www.cve.org/CVERecord?id=CVE-2021-46304" }, { "name": "CVE-2020-7587", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7587" }, { "name": "CVE-2020-7588", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7588" }, { "name": "CVE-2022-34661", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34661" }, { "name": "CVE-2022-36325", "url": "https://www.cve.org/CVERecord?id=CVE-2022-36325" }, { "name": "CVE-2020-7581", "url": "https://www.cve.org/CVERecord?id=CVE-2020-7581" }, { "name": "CVE-2022-36323", "url": "https://www.cve.org/CVERecord?id=CVE-2022-36323" }, { "name": "CVE-2022-36324", "url": "https://www.cve.org/CVERecord?id=CVE-2022-36324" }, { "name": "CVE-2022-34659", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34659" }, { "name": "CVE-2022-34660", "url": "https://www.cve.org/CVERecord?id=CVE-2022-34660" } ], "initial_release_date": "2022-08-09T00:00:00", "last_revision_date": "2022-08-09T00:00:00", "links": [], "reference": "CERTFR-2022-AVI-718", "revisions": [ { "description": "Version initiale", "revision_date": "2022-08-09T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Injection de code indirecte \u00e0 distance (XSS)" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-841348 du 9 ao\u00fbt 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-841348.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-555707 du 9 ao\u00fbt 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-555707.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-759952 du 9 ao\u00fbt 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-759952.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-185638 du 9 ao\u00fbt 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-185638.html" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-710008 du 9 ao\u00fbt 2022", "url": "https://cert-portal.siemens.com/productcert/html/ssa-710008.html" } ] }
cnvd-2022-56477
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-555707.html
Name | Siemens Simcenter STAR-CCM+ null |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2022-34659" } }, "description": "Simcenter STAR-CCM+\u662f\u4e00\u4e2a\u591a\u7269\u7406\u8ba1\u7b97\u6d41\u4f53\u52a8\u529b\u5b66\uff08CFD\uff09\u8f6f\u4ef6\uff0c\u7528\u4e8e\u6a21\u62df\u5728\u771f\u5b9e\u4e16\u754c\u6761\u4ef6\u4e0b\u8fd0\u884c\u7684\u4ea7\u54c1\u3002\n\nSiemens Simcenter STAR-CCM+\u5b58\u5728\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u662f\u7531\u4e8e\u4f7f\u7528\u516c\u5171\u8bb8\u53ef\u8bc1\u670d\u52a1\u5668\u65f6\uff0c\u53d7\u5f71\u54cd\u7684\u5e94\u7528\u7a0b\u5e8f\u4f1a\u516c\u5f00\u7528\u6237\u3001\u4e3b\u673a\u548c\u663e\u793a\u540d\u79f0\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u68c0\u7d22\u6b64\u4fe1\u606f\u3002", "formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-555707.html", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2022-56477", "openTime": "2022-08-12", "patchDescription": "Simcenter STAR-CCM+\u662f\u4e00\u4e2a\u591a\u7269\u7406\u8ba1\u7b97\u6d41\u4f53\u52a8\u529b\u5b66\uff08CFD\uff09\u8f6f\u4ef6\uff0c\u7528\u4e8e\u6a21\u62df\u5728\u771f\u5b9e\u4e16\u754c\u6761\u4ef6\u4e0b\u8fd0\u884c\u7684\u4ea7\u54c1\u3002\r\n\r\nSiemens Simcenter STAR-CCM+\u5b58\u5728\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u662f\u7531\u4e8e\u4f7f\u7528\u516c\u5171\u8bb8\u53ef\u8bc1\u670d\u52a1\u5668\u65f6\uff0c\u53d7\u5f71\u54cd\u7684\u5e94\u7528\u7a0b\u5e8f\u4f1a\u516c\u5f00\u7528\u6237\u3001\u4e3b\u673a\u548c\u663e\u793a\u540d\u79f0\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u68c0\u7d22\u6b64\u4fe1\u606f\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens Simcenter STAR-CCM+\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": "Siemens Simcenter STAR-CCM+ null" }, "serverity": "\u4e2d", "submitTime": "2022-08-09", "title": "Siemens Simcenter STAR-CCM+\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e" }
var-202208-0785
Vulnerability from variot
A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information. Siemens' simcenter star-ccm+ viewer There is a vulnerability related to information leakage.Information may be obtained
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0785", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simcenter star-ccm\\+ viewer", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simcenter star-ccm+ viewer", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simcenter star-ccm+ viewer", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2719" } ], "trust": 0.6 }, "cve": "CVE-2022-34659", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-34659", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-34659", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-34659", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-34659", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202208-2719", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information. Siemens\u0027 simcenter star-ccm+ viewer There is a vulnerability related to information leakage.Information may be obtained", "sources": [ { "db": "NVD", "id": "CVE-2022-34659" }, { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "VULMON", "id": "CVE-2022-34659" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-34659", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-555707", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-22-223-01", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU90767165", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-014798", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2022.4038", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202208-2719", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-34659", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-34659" }, { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "id": "VAR-202208-0785", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.225 }, "last_update_date": "2024-08-14T14:17:45.385000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens Simcenter STAR-CCM+ Repair measures for information disclosure vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=204575" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2719" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.0 }, { "problemtype": "information leak (CWE-200) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90767165/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34659" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-01" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-01" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-34659/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.4038" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/200.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-01" } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-34659" }, { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2022-34659" }, { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-34659" }, { "date": "2023-09-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "date": "2022-08-10T12:15:12.143000", "db": "NVD", "id": "CVE-2022-34659" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-34659" }, { "date": "2023-09-21T08:10:00", "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "date": "2022-08-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "date": "2022-08-16T15:58:26.020000", "db": "NVD", "id": "CVE-2022-34659" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2719" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0simcenter\u00a0star-ccm+\u00a0viewer\u00a0 Vulnerability regarding information leakage in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014798" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2719" } ], "trust": 0.6 } }
fkie_cve-2022-34659
Vulnerability from fkie_nvd
URL | Tags | ||
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf | Mitigation, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
siemens | simcenter_star-ccm\+_viewer | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simcenter_star-ccm\\+_viewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C21E9FD-B467-43FF-8ECE-DDA5FC3521D4", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Simcenter STAR-CCM+ (Todas las versiones s\u00f3lo si es usado el servidor de licencias p\u00fablicas Power-on-Demand). Las aplicaciones afectadas exponen el usuario, el host y el nombre de pantalla de los usuarios, cuando se usa el servidor p\u00fablico de licencias. Esto podr\u00eda permitir a un atacante recuperar esta informaci\u00f3n" } ], "id": "CVE-2022-34659", "lastModified": "2024-11-21T07:09:55.463", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-08-10T12:15:12.143", "references": [ { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.