var-202208-0785
Vulnerability from variot
A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information. Siemens' simcenter star-ccm+ viewer There is a vulnerability related to information leakage.Information may be obtained
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0785", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simcenter star-ccm\\+ viewer", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simcenter star-ccm+ viewer", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simcenter star-ccm+ viewer", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2719" } ], "trust": 0.6 }, "cve": "CVE-2022-34659", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2022-34659", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-34659", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2022-34659", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2022-34659", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202208-2719", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Simcenter STAR-CCM+ (All versions only if the Power-on-Demand public license server is used). Affected applications expose user, host and display name of users, when the public license server is used. This could allow an attacker to retrieve this information. Siemens\u0027 simcenter star-ccm+ viewer There is a vulnerability related to information leakage.Information may be obtained", "sources": [ { "db": "NVD", "id": "CVE-2022-34659" }, { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "VULMON", "id": "CVE-2022-34659" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-34659", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-555707", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-22-223-01", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU90767165", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-014798", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2022.4038", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202208-2719", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-34659", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-34659" }, { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "id": "VAR-202208-0785", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.225 }, "last_update_date": "2024-08-14T14:17:45.385000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens Simcenter STAR-CCM+ Repair measures for information disclosure vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=204575" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2719" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.0 }, { "problemtype": "information leak (CWE-200) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-555707.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu90767165/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-34659" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-223-01" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-223-01" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-34659/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.4038" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/200.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-223-01" } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-34659" }, { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2022-34659" }, { "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "db": "NVD", "id": "CVE-2022-34659" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-34659" }, { "date": "2023-09-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "date": "2022-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "date": "2022-08-10T12:15:12.143000", "db": "NVD", "id": "CVE-2022-34659" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-10T00:00:00", "db": "VULMON", "id": "CVE-2022-34659" }, { "date": "2023-09-21T08:10:00", "db": "JVNDB", "id": "JVNDB-2022-014798" }, { "date": "2022-08-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-2719" }, { "date": "2022-08-16T15:58:26.020000", "db": "NVD", "id": "CVE-2022-34659" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2719" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens\u0027 \u00a0simcenter\u00a0star-ccm+\u00a0viewer\u00a0 Vulnerability regarding information leakage in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-014798" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-2719" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…