CVE-2022-29095
Vulnerability from cvelistv5
Published
2022-06-10 20:05
Modified
2024-09-16 23:56
Severity ?
EPSS score ?
Summary
Dell SupportAssist Client Consumer versions (3.10.4 and prior) and Dell SupportAssist Client Commercial versions (3.1.1 and prior) contain a cross-site scripting vulnerability. A remote unauthenticated malicious user could potentially exploit this vulnerability under specific conditions leading to execution of malicious code on a vulnerable system.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | SupportAssist Consumer |
Version: unspecified < |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T06:10:59.261Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000200456/dsa-2022-139-dell-supportassist-for-home-pcs-and-business-pcs-security-update-for-multiple-security-vulnerabilities" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SupportAssist Consumer", "vendor": "Dell", "versions": [ { "lessThanOrEqual": "3.10.4", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2022-06-09T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell SupportAssist Client Consumer versions (3.10.4 and prior) and Dell SupportAssist Client Commercial versions (3.1.1 and prior) contain a cross-site scripting vulnerability. A remote unauthenticated malicious user could potentially exploit this vulnerability under specific conditions leading to execution of malicious code on a vulnerable system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-16", "description": "CWE-16: Configuration", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-06-10T20:05:20", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/kbdoc/en-us/000200456/dsa-2022-139-dell-supportassist-for-home-pcs-and-business-pcs-security-update-for-multiple-security-vulnerabilities" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2022-06-09", "ID": "CVE-2022-29095", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SupportAssist Consumer", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "3.10.4" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell SupportAssist Client Consumer versions (3.10.4 and prior) and Dell SupportAssist Client Commercial versions (3.1.1 and prior) contain a cross-site scripting vulnerability. A remote unauthenticated malicious user could potentially exploit this vulnerability under specific conditions leading to execution of malicious code on a vulnerable system." } ] }, "impact": { "cvss": { "baseScore": 8.3, "baseSeverity": "High", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-16: Configuration" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/kbdoc/en-us/000200456/dsa-2022-139-dell-supportassist-for-home-pcs-and-business-pcs-security-update-for-multiple-security-vulnerabilities", "refsource": "MISC", "url": "https://www.dell.com/support/kbdoc/en-us/000200456/dsa-2022-139-dell-supportassist-for-home-pcs-and-business-pcs-security-update-for-multiple-security-vulnerabilities" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2022-29095", "datePublished": "2022-06-10T20:05:20.356928Z", "dateReserved": "2022-04-12T00:00:00", "dateUpdated": "2024-09-16T23:56:57.157Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-29095\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2022-06-10T20:15:08.473\",\"lastModified\":\"2024-11-21T06:58:28.460\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell SupportAssist Client Consumer versions (3.10.4 and prior) and Dell SupportAssist Client Commercial versions (3.1.1 and prior) contain a cross-site scripting vulnerability. A remote unauthenticated malicious user could potentially exploit this vulnerability under specific conditions leading to execution of malicious code on a vulnerable system.\"},{\"lang\":\"es\",\"value\":\"Dell SupportAssist Client Consumer versiones (3.10.4 y anteriores) y Dell SupportAssist Client Commercial (3.1.1 y anteriores) contienen una vulnerabilidad de tipo cross-site scripting. Un usuario remoto malicioso no autenticado podr\u00eda explotar esta vulnerabilidad bajo condiciones espec\u00edficas que conllevan a una ejecuci\u00f3n de c\u00f3digo malicioso en un sistema vulnerable\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H\",\"baseScore\":8.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H\",\"baseScore\":9.6,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:H/Au:N/C:C/I:C/A:C\",\"baseScore\":7.6,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"HIGH\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":4.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-16\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:supportassist_for_business_pcs:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.1.1\",\"matchCriteriaId\":\"4B04FBAC-E9D5-4F49-B261-43084F08EA31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:supportassist_for_home_pcs:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.10.4\",\"matchCriteriaId\":\"12FEDD17-E770-4EFB-AC84-83A83A5D07B1\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000200456/dsa-2022-139-dell-supportassist-for-home-pcs-and-business-pcs-security-update-for-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000200456/dsa-2022-139-dell-supportassist-for-home-pcs-and-business-pcs-security-update-for-multiple-security-vulnerabilities\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.