CVE-2022-27612 (GCVE-0-2022-27612)
Vulnerability from cvelistv5 – Published: 2022-07-28 07:10 – Updated: 2024-09-17 00:45
VLAI?
Summary
Buffer copy without checking size of input ('Classic Buffer Overflow') vulnerability in cgi component in Synology Audio Station before 6.5.4-3367 allows remote attackers to execute arbitrary commands via unspecified vectors.
Severity ?
7.3 (High)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Synology | Audio Station |
Affected:
unspecified , < 6.5.4-3367
(custom)
|
Date Public ?
2022-07-25 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:32:59.706Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.synology.com/security/advisory/Synology_SA_21_21"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Audio Station",
"vendor": "Synology",
"versions": [
{
"lessThan": "6.5.4-3367",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-07-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Buffer copy without checking size of input (\u0027Classic Buffer Overflow\u0027) vulnerability in cgi component in Synology Audio Station before 6.5.4-3367 allows remote attackers to execute arbitrary commands via unspecified vectors."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-28T07:10:12.000Z",
"orgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
"shortName": "synology"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.synology.com/security/advisory/Synology_SA_21_21"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@synology.com",
"DATE_PUBLIC": "2022-07-25T15:06:01.657529",
"ID": "CVE-2022-27612",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Audio Station",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "6.5.4-3367"
}
]
}
}
]
},
"vendor_name": "Synology"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer copy without checking size of input (\u0027Classic Buffer Overflow\u0027) vulnerability in cgi component in Synology Audio Station before 6.5.4-3367 allows remote attackers to execute arbitrary commands via unspecified vectors."
}
]
},
"impact": {
"cvss": {
"baseScore": "7.3",
"vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.synology.com/security/advisory/Synology_SA_21_21",
"refsource": "CONFIRM",
"url": "https://www.synology.com/security/advisory/Synology_SA_21_21"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
"assignerShortName": "synology",
"cveId": "CVE-2022-27612",
"datePublished": "2022-07-28T07:10:12.295Z",
"dateReserved": "2022-03-21T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:45:58.126Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-27612",
"date": "2026-05-07",
"epss": "0.01926",
"percentile": "0.83488"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:synology:audio_station:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.5.4-3367\", \"matchCriteriaId\": \"9865C484-7CDC-4E34-BF95-C4302925FB88\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Buffer copy without checking size of input (\u0027Classic Buffer Overflow\u0027) vulnerability in cgi component in Synology Audio Station before 6.5.4-3367 allows remote attackers to execute arbitrary commands via unspecified vectors.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de la copia del b\\u00fafer sin comprobar el tama\\u00f1o de la entrada (\\\"Desbordamiento de B\\u00fafer Cl\\u00e1sico\\\") en el componente cgi de Synology Audio Station versiones anteriores a 6.5.4-3367, permite a atacantes remotos ejecutar comandos arbitrarios por medio de vectores no especificados\"}]",
"id": "CVE-2022-27612",
"lastModified": "2024-11-21T06:56:01.463",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"security@synology.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
"published": "2022-07-28T07:15:07.897",
"references": "[{\"url\": \"https://www.synology.com/security/advisory/Synology_SA_21_21\", \"source\": \"security@synology.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.synology.com/security/advisory/Synology_SA_21_21\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "security@synology.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"security@synology.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-120\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-120\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-27612\",\"sourceIdentifier\":\"security@synology.com\",\"published\":\"2022-07-28T07:15:07.897\",\"lastModified\":\"2024-11-21T06:56:01.463\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer copy without checking size of input (\u0027Classic Buffer Overflow\u0027) vulnerability in cgi component in Synology Audio Station before 6.5.4-3367 allows remote attackers to execute arbitrary commands via unspecified vectors.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de la copia del b\u00fafer sin comprobar el tama\u00f1o de la entrada (\\\"Desbordamiento de B\u00fafer Cl\u00e1sico\\\") en el componente cgi de Synology Audio Station versiones anteriores a 6.5.4-3367, permite a atacantes remotos ejecutar comandos arbitrarios por medio de vectores no especificados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security@synology.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security@synology.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:synology:audio_station:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.5.4-3367\",\"matchCriteriaId\":\"9865C484-7CDC-4E34-BF95-C4302925FB88\"}]}]}],\"references\":[{\"url\":\"https://www.synology.com/security/advisory/Synology_SA_21_21\",\"source\":\"security@synology.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.synology.com/security/advisory/Synology_SA_21_21\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…