CVE-2022-24069 (GCVE-0-2022-24069)

Vulnerability from cvelistv5 – Published: 2022-02-02 23:46 – Updated: 2026-08-11 12:22
VLAI
Summary
An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.0 before 05.08.41, 5.1 before 05.16.29, 5.2 before 05.26.29, 5.3 before 05.35.29, 5.4 before 05.43.29, and 5.5 before 05.51.29. An SMM callout vulnerability allows an attacker to hijack the execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
CWE
  • n/a
Impacted products
Vendor Product Version CPE status
Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
guessed Create a notification for this product.
Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
guessed Create a notification for this product.
Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
guessed Create a notification for this product.
Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
guessed Create a notification for this product.
Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
guessed Create a notification for this product.
Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T19:13:01.180Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220216-0002/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
          },
          {
            "url": "https://www.kb.cert.org/vuls/id/796611"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "defaultStatus": "unknown",
            "product": "RUGGEDCOM APE1808 - BIOS",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V1.0.202N",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC Field PG M5",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V22.01.10",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC Field PG M6",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V26.01.13",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC127E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V27.01.09",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC227G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC277G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC\u00a0IPC277G PRO",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC327G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC377G",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V28.01.04",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC427E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC477E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC477E PRO",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC627E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC647E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC677E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC IPC847E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V25.02.12",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIMATIC ITP1000",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V23.01.10",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "defaultStatus": "unknown",
            "product": "SIPLUS IPC427E",
            "vendor": "Siemens",
            "versions": [
              {
                "lessThan": "V21.01.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-11T12:22:31.135Z",
          "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "shortName": "siemens-SADP"
        },
        "references": [
          {
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
          }
        ],
        "x_adpType": "supplier"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.0 before 05.08.41, 5.1 before 05.16.29, 5.2 before 05.26.29, 5.3 before 05.35.29, 5.4 before 05.43.29, and 5.5 before 05.51.29. An SMM callout vulnerability allows an attacker to hijack the execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T19:06:38.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220216-0002/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2022-24069",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.0 before 05.08.41, 5.1 before 05.16.29, 5.2 before 05.26.29, 5.3 before 05.35.29, 5.4 before 05.43.29, and 5.5 before 05.51.29. An SMM callout vulnerability allows an attacker to hijack the execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.insyde.com/security-pledge",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220216-0002/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220216-0002/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2022-24069",
    "datePublished": "2022-02-02T23:46:35.000Z",
    "dateReserved": "2022-01-27T00:00:00.000Z",
    "dateUpdated": "2026-08-11T12:22:31.135Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-24069",
      "date": "2026-08-19",
      "epss": "0.00301",
      "percentile": "0.22807"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"5.1\", \"versionEndExcluding\": \"5.16.29\", \"matchCriteriaId\": \"D26CDAE4-0D04-4EB2-8A8C-CDEBDF8BA38C\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"5.2\", \"versionEndExcluding\": \"5.26.29\", \"matchCriteriaId\": \"E0546FD8-0648-46EB-893F-411F869077E5\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"5.3\", \"versionEndExcluding\": \"5.35.29\", \"matchCriteriaId\": \"89966555-5DD1-4C61-B3B2-7AF7AF7D24D9\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"5.0\", \"versionEndExcluding\": \"5.08.29\", \"matchCriteriaId\": \"95221F93-8BE6-47E3-BFB4-E7603C320F0D\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"5.4\", \"versionEndExcluding\": \"5.43.29\", \"matchCriteriaId\": \"FD4E7284-5376-4853-9C28-77867BCB1446\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"5.5\", \"versionEndExcluding\": \"5.51.29\", \"matchCriteriaId\": \"BE5BACC3-58DF-4CD6-A204-565CD002AC77\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.0 before 05.08.41, 5.1 before 05.16.29, 5.2 before 05.26.29, 5.3 before 05.35.29, 5.4 before 05.43.29, and 5.5 before 05.51.29. An SMM callout vulnerability allows an attacker to hijack the execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.\"}, {\"lang\": \"es\", \"value\": \"Se ha detectado un problema en AhciBusDxe en InsydeH2O con el kernel versi\\u00f3n 5.0 anteriores a 05.08.41, versiones 5.1 anteriores a 05.16.29, versiones 5.2 anteriores a 05.26.29, versiones 5.3 anteriores a 05.35.29, versiones 5.4 anteriores a 05.43.29 y versiones 5.5 anteriores a 05.51.29. Una vulnerabilidad en la llamada SMM permite a un atacante secuestrar el flujo de ejecuci\\u00f3n del c\\u00f3digo que es ejecutado en el modo de administraci\\u00f3n del sistema. Una explotaci\\u00f3n de este problema podr\\u00eda conllevar a una escalada de privilegios al SMM\"}]",
      "id": "CVE-2022-24069",
      "lastModified": "2024-11-21T06:49:45.807",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 8.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.5, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-02-03T00:15:07.723",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20220216-0002/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.insyde.com/security-pledge\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20220216-0002/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.insyde.com/security-pledge\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-24069\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-02-03T00:15:07.723\",\"lastModified\":\"2026-08-11T13:17:24.720\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.0 before 05.08.41, 5.1 before 05.16.29, 5.2 before 05.26.29, 5.3 before 05.35.29, 5.4 before 05.43.29, and 5.5 before 05.51.29. An SMM callout vulnerability allows an attacker to hijack the execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.\"},{\"lang\":\"es\",\"value\":\"Se ha detectado un problema en AhciBusDxe en InsydeH2O con el kernel versi\u00f3n 5.0 anteriores a 05.08.41, versiones 5.1 anteriores a 05.16.29, versiones 5.2 anteriores a 05.26.29, versiones 5.3 anteriores a 05.35.29, versiones 5.4 anteriores a 05.43.29 y versiones 5.5 anteriores a 05.51.29. Una vulnerabilidad en la llamada SMM permite a un atacante secuestrar el flujo de ejecuci\u00f3n del c\u00f3digo que es ejecutado en el modo de administraci\u00f3n del sistema. Una explotaci\u00f3n de este problema podr\u00eda conllevar a una escalada de privilegios al SMM\"}],\"affected\":[{\"source\":\"cve@mitre.org\",\"affectedData\":[{\"vendor\":\"n/a\",\"product\":\"n/a\",\"versions\":[{\"version\":\"n/a\",\"status\":\"affected\"}]}]},{\"source\":\"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e\",\"affectedData\":[{\"vendor\":\"Siemens\",\"product\":\"RUGGEDCOM APE1808 - BIOS\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V1.0.202N\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC Field PG M5\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V22.01.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC Field PG M6\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V26.01.13\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC127E\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V27.01.09\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC227G\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V28.01.04\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC277G\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V28.01.04\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC\u00a0IPC277G PRO\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V28.01.04\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC327G\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V28.01.04\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC377G\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V28.01.04\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC427E\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V21.01.17\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC477E\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V21.01.17\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC477E PRO\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V21.01.17\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC627E\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V25.02.12\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC647E\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V25.02.12\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC677E\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V25.02.12\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC IPC847E\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V25.02.12\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIMATIC ITP1000\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V23.01.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"Siemens\",\"product\":\"SIPLUS IPC427E\",\"defaultStatus\":\"unknown\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"V21.01.17\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.5,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.1\",\"versionEndExcluding\":\"5.16.29\",\"matchCriteriaId\":\"D26CDAE4-0D04-4EB2-8A8C-CDEBDF8BA38C\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.2\",\"versionEndExcluding\":\"5.26.29\",\"matchCriteriaId\":\"E0546FD8-0648-46EB-893F-411F869077E5\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.3\",\"versionEndExcluding\":\"5.35.29\",\"matchCriteriaId\":\"89966555-5DD1-4C61-B3B2-7AF7AF7D24D9\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.0\",\"versionEndExcluding\":\"5.08.29\",\"matchCriteriaId\":\"95221F93-8BE6-47E3-BFB4-E7603C320F0D\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4\",\"versionEndExcluding\":\"5.43.29\",\"matchCriteriaId\":\"FD4E7284-5376-4853-9C28-77867BCB1446\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.5\",\"versionEndExcluding\":\"5.51.29\",\"matchCriteriaId\":\"BE5BACC3-58DF-4CD6-A204-565CD002AC77\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20220216-0002/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.insyde.com/security-pledge\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20220216-0002/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.insyde.com/security-pledge\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.kb.cert.org/vuls/id/796611\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-306654.html\",\"source\":\"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e\"}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-29T02:00:31+00:00",
      "cve": "CVE-2022-24069",
      "id": "CVE-2022-24069",
      "initial_release_date": "2022-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2022-24069",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-24069.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…