CVE-2021-33738 (GCVE-0-2021-33738)
Vulnerability from cvelistv5
- CWE-125 - Out-of-bounds Read
| URL | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT2Go |
Version: All versions < V13.2.0.2 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:58:22.886Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.2"
}
]
},
{
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:39",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-33738",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2.0.2"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2.0.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-33738",
"datePublished": "2021-08-10T10:35:33",
"dateReserved": "2021-05-28T00:00:00",
"dateUpdated": "2024-08-03T23:58:22.886Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2021-33738\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-08-10T11:15:09.197\",\"lastModified\":\"2024-11-21T06:09:28.897\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.2), Teamcenter Visualization (Todas las versiones anteriores a V13.2.0.2). La biblioteca plmxmlAdapterSE70.dll de las aplicaciones afectadas no comprueba apropiadamente los datos suministrados por el usuario cuando analiza los archivos PAR. Esto podr\u00eda resultar en una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-13405)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.2\",\"matchCriteriaId\":\"FB703B83-3389-470A-B6D7-F8E6A2ACEC62\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.2.0.2\",\"matchCriteriaId\":\"960C485F-738E-4E5C-ABA5-32E1A260C6A8\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-981/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-981/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
}
}
cnvd-2021-61121
Vulnerability from cnvd
用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf
| Name | ['SIEMENS JT2Go < V13.2.0.2', 'SIEMENS Teamcenter Visualization < V13.2.0.2'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2021-33738"
}
},
"description": "Siemens Jt2go\u662f\u4e00\u6b3eJT\u6587\u4ef6\u67e5\u770b\u5668\u3002Siemens Teamcenter Visualization\u662f\u4e00\u4e2a\u53ef\u4e3a\u8bbe\u8ba12D\u30013D\u573a\u666f\u63d0\u4f9b\u56e2\u961f\u534f\u4f5c\u529f\u80fd\u7684\u8f6f\u4ef6\u3002\u3002\n\nSiemens Jt2go\u548cSiemens Teamcenter Visualization\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5e94\u7528\u7a0b\u5e8f\u4e2d\u7684plmxmlAdapterSE70.dll\u5e93\u7f3a\u4e4f\u5bf9\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\u7684\u6b63\u786e\u9a8c\u8bc1\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6cc4\u9732\u4fe1\u606f\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-61121",
"openTime": "2021-08-11",
"patchDescription": "Siemens Jt2go\u662f\u4e00\u6b3eJT\u6587\u4ef6\u67e5\u770b\u5668\u3002Siemens Teamcenter Visualization\u662f\u4e00\u4e2a\u53ef\u4e3a\u8bbe\u8ba12D\u30013D\u573a\u666f\u63d0\u4f9b\u56e2\u961f\u534f\u4f5c\u529f\u80fd\u7684\u8f6f\u4ef6\u3002\u3002\r\n\r\nSiemens Jt2go\u548cSiemens Teamcenter Visualization\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5e94\u7528\u7a0b\u5e8f\u4e2d\u7684plmxmlAdapterSE70.dll\u5e93\u7f3a\u4e4f\u5bf9\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\u7684\u6b63\u786e\u9a8c\u8bc1\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6cc4\u9732\u4fe1\u606f\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Jt2go\u548cSiemens Teamcenter Visualization\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff08CNVD-2021-61121\uff09\u7684\u8865\u4e01",
"products": {
"product": [
"SIEMENS JT2Go \u003c V13.2.0.2",
"SIEMENS Teamcenter Visualization \u003c V13.2.0.2"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf",
"serverity": "\u4f4e",
"submitTime": "2021-08-11",
"title": "Siemens Jt2go\u548cSiemens Teamcenter Visualization\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e\uff08CNVD-2021-61121\uff09"
}
ICSA-21-222-03
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
},
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
},
{
"organization": "Open Design Alliance",
"summary": "coordination efforts"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens has released version V13.2.0.2 for JT2Go and Teamcenter Visualization to fix three vulnerabilities that could be triggered while parsing DGN or PAR files. If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potential arbitrary code execution.\n\nSiemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products.\n\nNote:\n\n- This advisory also covers security vulnerabilities recently disclosed by Open Design Alliance [0]\n\n[0] https://www.opendesign.com/security-advisories",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-938030: DGN and PAR File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.2 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-938030.json"
},
{
"category": "self",
"summary": "SSA-938030: DGN and PAR File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.2 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-938030.txt"
},
{
"category": "self",
"summary": "SSA-938030: DGN and PAR File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.2 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-222-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-222-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-222-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-222-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens JT2Go and Teamcenter Visualization (Update A)",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-222-03",
"initial_release_date": "2021-08-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-08-10T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-09-14T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added download links for the fix releases"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.2.0.2",
"product": {
"name": "JT2Go",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "JT2Go"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.2.0.2",
"product": {
"name": "Teamcenter Visualization",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-32946",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "summary",
"text": "An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Open Design Alliance Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2021-32946 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-32946 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32946.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-32946"
},
{
"cve": "CVE-2021-32952",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write issue exists in the DGN file-reading procedure in the Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2021-32952 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-32952 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32952.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-32952"
},
{
"cve": "CVE-2021-33738",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2021-33738 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-33738 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-33738.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-33738"
}
]
}
icsa-21-222-03
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting this vulnerability to CISA."
},
{
"organization": "Trend Micro Zero Day Initiative",
"summary": "coordinated disclosure"
},
{
"organization": "Open Design Alliance",
"summary": "coordination efforts"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens has released version V13.2.0.2 for JT2Go and Teamcenter Visualization to fix three vulnerabilities that could be triggered while parsing DGN or PAR files. If a user is tricked to open a malicious file with the affected products, this could lead the application to crash or potential arbitrary code execution.\n\nSiemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products.\n\nNote:\n\n- This advisory also covers security vulnerabilities recently disclosed by Open Design Alliance [0]\n\n[0] https://www.opendesign.com/security-advisories",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-938030: DGN and PAR File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.2 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-938030.json"
},
{
"category": "self",
"summary": "SSA-938030: DGN and PAR File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.2 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-938030.txt"
},
{
"category": "self",
"summary": "SSA-938030: DGN and PAR File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.2.0.2 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-222-03 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-222-03.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-222-03 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-222-03"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens JT2Go and Teamcenter Visualization (Update A)",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-222-03",
"initial_release_date": "2021-08-10T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-08-10T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2021-09-14T00:00:00.000000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added download links for the fix releases"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "3",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.2.0.2",
"product": {
"name": "JT2Go",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "JT2Go"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV13.2.0.2",
"product": {
"name": "Teamcenter Visualization",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Teamcenter Visualization"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-32946",
"cwe": {
"id": "CWE-754",
"name": "Improper Check for Unusual or Exceptional Conditions"
},
"notes": [
{
"category": "summary",
"text": "An improper check for unusual or exceptional conditions issue exists within the parsing DGN files from Open Design Alliance Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of the user-supplied data. This may result in several of out-of-bounds problems and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2021-32946 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-32946 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32946.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-32946"
},
{
"cve": "CVE-2021-32952",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An out-of-bounds write issue exists in the DGN file-reading procedure in the Drawings SDK (Version 2022.4 and prior) resulting from the lack of proper validation of user-supplied data. This can result in a write past the end of an allocated buffer and allow attackers to cause a denial-of-service condition or execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2021-32952 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-32952 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32952.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-32952"
},
{
"cve": "CVE-2021-33738",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2021-33738 - JT2Go",
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"summary": "CVE-2021-33738 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-33738.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
},
{
"category": "vendor_fix",
"details": "Update to V13.2.0.2 or later version",
"product_ids": [
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2021-33738"
}
]
}
fkie_cve-2021-33738
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf | Vendor Advisory | |
| productcert@siemens.com | https://www.zerodayinitiative.com/advisories/ZDI-21-981/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-21-981/ | Third Party Advisory, VDB Entry |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | jt2go | * | |
| siemens | teamcenter_visualization | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FB703B83-3389-470A-B6D7-F8E6A2ACEC62",
"versionEndExcluding": "13.2.0.2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"matchCriteriaId": "960C485F-738E-4E5C-ABA5-32E1A260C6A8",
"versionEndExcluding": "13.2.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones anteriores a V13.2.0.2), Teamcenter Visualization (Todas las versiones anteriores a V13.2.0.2). La biblioteca plmxmlAdapterSE70.dll de las aplicaciones afectadas no comprueba apropiadamente los datos suministrados por el usuario cuando analiza los archivos PAR. Esto podr\u00eda resultar en una lectura fuera de l\u00edmites m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante podr\u00eda aprovechar esta vulnerabilidad para filtrar informaci\u00f3n en el contexto del proceso actual. (ZDI-CAN-13405)"
}
],
"id": "CVE-2021-33738",
"lastModified": "2024-11-21T06:09:28.897",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-08-10T11:15:09.197",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
ghsa-64rg-cj2r-7j3g
Vulnerability from github
A vulnerability has been identified in JT2Go (All versions < V13.2.0.2), Teamcenter Visualization (All versions < V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)
{
"affected": [],
"aliases": [
"CVE-2021-33738"
],
"database_specific": {
"cwe_ids": [
"CWE-125"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-08-10T11:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)",
"id": "GHSA-64rg-cj2r-7j3g",
"modified": "2022-05-24T19:10:37Z",
"published": "2022-05-24T19:10:37Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-33738"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"type": "WEB",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981"
}
],
"schema_version": "1.4.0",
"severity": []
}
CERTFR-2021-AVI-608
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC NET CP 1545-1 | ||
| Siemens | N/A | SIMATIC Drive Controller family versions antérieures à V2.9.2 | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller | ||
| Siemens | N/A | TIM 1531 IRC (incl. SIPLUS NET variants) versions antérieures à V2.2 | ||
| Siemens | N/A | Automation License Manager 6 versions antérieures à V6.0 SP9 Update 2 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) versions antérieures à V2.9.2 | ||
| Siemens | N/A | SINEC NMS versions antérieures à V1.0 SP2 | ||
| Siemens | N/A | Automation License Manager 5 | ||
| Siemens | N/A | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) versions V4.4.x antérieures à V4.4.1 | ||
| Siemens | N/A | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) versions V4.5.x antérieures à V4.5.1 | ||
| Siemens | N/A | SIMATIC S7 PLCSIM Advanced versions antérieures à V4 | ||
| Siemens | N/A | T2Go versions antérieures à V13.2.0.2 | ||
| Siemens | N/A | Solid Edge SE2021 versions antérieures à SE2021MP7 | ||
| Siemens | N/A | Teamcenter Visualization versions antérieures à V13.2.0.2 | ||
| Siemens | N/A | SGT-100, SGT-200, SGT-300, SGT-400, SGT-A20, SGT-A35 et SGT-A65 | ||
| Siemens | N/A | de nombreux produits SIMATIC et SINUMERIK (cf. avis de sécurité ssa-309571) | ||
| Siemens | N/A | SIMATIC NET CP 1543-1 (incl. SIPLUS NET variants) versions antérieures à V3.0 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU 515SP PC2 (incl. SIPLUS variants) |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC NET CP 1545-1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Drive Controller family versions ant\u00e9rieures \u00e0 V2.9.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 1531 IRC (incl. SIPLUS NET variants) versions ant\u00e9rieures \u00e0 V2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Automation License Manager 6 versions ant\u00e9rieures \u00e0 V6.0 SP9 Update 2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) versions ant\u00e9rieures \u00e0 V2.9.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC NMS versions ant\u00e9rieures \u00e0 V1.0 SP2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Automation License Manager 5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants) versions V4.4.x ant\u00e9rieures \u00e0 V4.4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants) versions V4.5.x ant\u00e9rieures \u00e0 V4.5.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7 PLCSIM Advanced versions ant\u00e9rieures \u00e0 V4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "T2Go versions ant\u00e9rieures \u00e0 V13.2.0.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2021 versions ant\u00e9rieures \u00e0 SE2021MP7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions ant\u00e9rieures \u00e0 V13.2.0.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SGT-100, SGT-200, SGT-300, SGT-400, SGT-A20, SGT-A35 et SGT-A65",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "de nombreux produits SIMATIC et SINUMERIK (cf. avis de s\u00e9curit\u00e9 ssa-309571)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 1543-1 (incl. SIPLUS NET variants) versions ant\u00e9rieures \u00e0 V3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU 515SP PC2 (incl. SIPLUS variants)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-33721",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33721"
},
{
"name": "CVE-2021-32944",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32944"
},
{
"name": "CVE-2021-37178",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37178"
},
{
"name": "CVE-2021-32936",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32936"
},
{
"name": "CVE-2016-20009",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-20009"
},
{
"name": "CVE-2021-33717",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33717"
},
{
"name": "CVE-2021-32946",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32946"
},
{
"name": "CVE-2020-12360",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12360"
},
{
"name": "CVE-2020-9272",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9272"
},
{
"name": "CVE-2021-32938",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32938"
},
{
"name": "CVE-2021-32940",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32940"
},
{
"name": "CVE-2020-8703",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8703"
},
{
"name": "CVE-2020-12357",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12357"
},
{
"name": "CVE-2021-32948",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32948"
},
{
"name": "CVE-2021-37172",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37172"
},
{
"name": "CVE-2020-24513",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24513"
},
{
"name": "CVE-2021-32952",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32952"
},
{
"name": "CVE-2020-24507",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24507"
},
{
"name": "CVE-2021-33738",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33738"
},
{
"name": "CVE-2020-12358",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-12358"
},
{
"name": "CVE-2021-32950",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32950"
},
{
"name": "CVE-2020-9273",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9273"
},
{
"name": "CVE-2021-37180",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37180"
},
{
"name": "CVE-2020-8670",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8670"
},
{
"name": "CVE-2020-8704",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8704"
},
{
"name": "CVE-2021-25659",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25659"
},
{
"name": "CVE-2020-24486",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24486"
},
{
"name": "CVE-2020-24506",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24506"
},
{
"name": "CVE-2020-24512",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24512"
},
{
"name": "CVE-2021-37179",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37179"
},
{
"name": "CVE-2020-24511",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24511"
},
{
"name": "CVE-2020-28397",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28397"
}
],
"initial_release_date": "2021-08-10T00:00:00",
"last_revision_date": "2021-08-10T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-608",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-08-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-309571 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-865327 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-365397 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-365397.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-938030 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-679335 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-679335.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-553445 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-553445.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-158827 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-158827.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-818688 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-818688.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-756744 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756744.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-830194 du 10 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-830194.pdf"
}
]
}
var-202108-1316
Vulnerability from variot
A vulnerability has been identified in JT2Go (All versions < V13.2.0.2), Teamcenter Visualization (All versions < V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds read. Zero Day Initiative To this vulnerability ZDI-CAN-13405 Was numbered.Information may be obtained. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{
"affected_products": {
"_id": null,
"data": [
{
"_id": null,
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "13.2.0.2"
},
{
"_id": null,
"model": "jt2go",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "13.2.0.2"
},
{
"_id": null,
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "13.2.0.2"
},
{
"_id": null,
"model": "jt2go",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"_id": null,
"model": "jt2go",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-981"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-009793"
},
{
"db": "NVD",
"id": "CVE-2021-33738"
}
]
},
"configurations": {
"_id": null,
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "13.2.0.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "13.2.0.2",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-33738"
}
]
},
"credits": {
"_id": null,
"data": "Mat Powell of Trend Micro Zero Day Initiative",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-981"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-953"
}
],
"trust": 1.3
},
"cve": "CVE-2021-33738",
"cvss": {
"_id": null,
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2021-33738",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 3.3,
"baseSeverity": "Low",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2021-33738",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.8,
"id": "CVE-2021-33738",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-33738",
"trust": 1.8,
"value": "LOW"
},
{
"author": "ZDI",
"id": "CVE-2021-33738",
"trust": 0.7,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202104-975",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202108-953",
"trust": 0.6,
"value": "LOW"
},
{
"author": "VULMON",
"id": "CVE-2021-33738",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-981"
},
{
"db": "VULMON",
"id": "CVE-2021-33738"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-009793"
},
{
"db": "NVD",
"id": "CVE-2021-33738"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-953"
}
]
},
"description": {
"_id": null,
"data": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405). JT2Go and Teamcenter Visualization Is vulnerable to an out-of-bounds read. Zero Day Initiative To this vulnerability ZDI-CAN-13405 Was numbered.Information may be obtained. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-33738"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-009793"
},
{
"db": "ZDI",
"id": "ZDI-21-981"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "VULMON",
"id": "CVE-2021-33738"
}
],
"trust": 2.88
},
"external_ids": {
"_id": null,
"data": [
{
"db": "NVD",
"id": "CVE-2021-33738",
"trust": 4.0
},
{
"db": "ZDI",
"id": "ZDI-21-981",
"trust": 3.2
},
{
"db": "SIEMENS",
"id": "SSA-938030",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-21-222-03",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU99791395",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-009793",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-13405",
"trust": 0.7
},
{
"db": "CS-HELP",
"id": "SB2021041363",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.2702",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2021081107",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202108-953",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-33738",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-981"
},
{
"db": "VULMON",
"id": "CVE-2021-33738"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-009793"
},
{
"db": "NVD",
"id": "CVE-2021-33738"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-953"
}
]
},
"id": "VAR-202108-1316",
"iot": {
"_id": null,
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.15799868
},
"last_update_date": "2023-12-18T11:12:42.949000Z",
"patch": {
"_id": null,
"data": [
{
"title": "SSA-938030",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"title": "",
"trust": 0.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-03https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"title": "Siemens Teamcenter Visualization and Siemens Jt2go Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=159347"
},
{
"title": "Arch Linux Issues: ",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=arch_linux_issues\u0026qid=cve-2021-33738 log"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=e0bde73e6fac136c31fc4dfabb276eae"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-981"
},
{
"db": "VULMON",
"id": "CVE-2021-33738"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-009793"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-953"
}
]
},
"problemtype_data": {
"_id": null,
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds read (CWE-125) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-009793"
},
{
"db": "NVD",
"id": "CVE-2021-33738"
}
]
},
"references": {
"_id": null,
"data": [
{
"trust": 2.6,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-981/"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"trust": 1.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-03"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu99791395/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-33738"
},
{
"trust": 0.7,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-222-03https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2021081107"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.2702"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/125.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://security.archlinux.org/cve-2021-33738"
},
{
"trust": 0.1,
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-938030.txt"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-981"
},
{
"db": "VULMON",
"id": "CVE-2021-33738"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-009793"
},
{
"db": "NVD",
"id": "CVE-2021-33738"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-953"
}
]
},
"sources": {
"_id": null,
"data": [
{
"db": "ZDI",
"id": "ZDI-21-981",
"ident": null
},
{
"db": "VULMON",
"id": "CVE-2021-33738",
"ident": null
},
{
"db": "JVNDB",
"id": "JVNDB-2021-009793",
"ident": null
},
{
"db": "NVD",
"id": "CVE-2021-33738",
"ident": null
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975",
"ident": null
},
{
"db": "CNNVD",
"id": "CNNVD-202108-953",
"ident": null
}
]
},
"sources_release_date": {
"_id": null,
"data": [
{
"date": "2021-08-18T00:00:00",
"db": "ZDI",
"id": "ZDI-21-981",
"ident": null
},
{
"date": "2021-08-10T00:00:00",
"db": "VULMON",
"id": "CVE-2021-33738",
"ident": null
},
{
"date": "2022-05-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-009793",
"ident": null
},
{
"date": "2021-08-10T11:15:09.197000",
"db": "NVD",
"id": "CVE-2021-33738",
"ident": null
},
{
"date": "2021-04-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-975",
"ident": null
},
{
"date": "2021-08-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202108-953",
"ident": null
}
]
},
"sources_update_date": {
"_id": null,
"data": [
{
"date": "2021-08-18T00:00:00",
"db": "ZDI",
"id": "ZDI-21-981",
"ident": null
},
{
"date": "2021-08-18T00:00:00",
"db": "VULMON",
"id": "CVE-2021-33738",
"ident": null
},
{
"date": "2022-05-24T08:26:00",
"db": "JVNDB",
"id": "JVNDB-2021-009793",
"ident": null
},
{
"date": "2021-09-21T16:27:35.173000",
"db": "NVD",
"id": "CVE-2021-33738",
"ident": null
},
{
"date": "2021-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-975",
"ident": null
},
{
"date": "2021-08-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202108-953",
"ident": null
}
]
},
"threat_type": {
"_id": null,
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202108-953"
}
],
"trust": 0.6
},
"title": {
"_id": null,
"data": "JT2Go\u00a0 and \u00a0Teamcenter\u00a0Visualization\u00a0 Out-of-bounds read vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-009793"
}
],
"trust": 0.8
},
"type": {
"_id": null,
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
}
],
"trust": 0.6
}
}
gsd-2021-33738
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2021-33738",
"description": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)",
"id": "GSD-2021-33738"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-33738"
],
"details": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)",
"id": "GSD-2021-33738",
"modified": "2023-12-13T01:23:18.113660Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-33738",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2.0.2"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2.0.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "13.2.0.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "13.2.0.2",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-33738"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2.0.2), Teamcenter Visualization (All versions \u003c V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-938030.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-981/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4
}
},
"lastModifiedDate": "2021-09-21T16:27Z",
"publishedDate": "2021-08-10T11:15Z"
}
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.