CVE-2021-26588 (GCVE-0-2021-26588)

Vulnerability from cvelistv5 – Published: 2021-10-11 16:46 – Updated: 2024-08-03 20:26
VLAI
Summary
A potential security vulnerability has been identified in HPE 3PAR StoreServ, HPE Primera Storage and HPE Alletra 9000 Storage array firmware. An unauthenticated user could remotely exploit the low complexity issue to execute code as administrator. This vulnerability impacts completely the confidentiality, integrity, availability of the array. HPE has made the following software updates and mitigation information to resolve the vulnerability in 3PAR, Primera and Alletra 9000 firmware.
CWE
  • remote arbitrary code execution
Assigner
hpe
References
Impacted products
Vendor Product Version
n/a HP 3PAR StoreServ 10000 Storage; HP 3PAR StoreServ 7000 Storage; HPE 3PAR StoreServ 8000 Storage; HPE Primera 600 Storage; HPE 3PAR StoreServ 20000; HPE Alletra 9000; HPE 3PAR StoreServ 9000 Storage Affected: 3.3.1 MU1 up to 3.3.1 MU2 P157 or 3.3.1 up to 3.3.1 MU5 P156 or 3.3.1 MU1 up to 3.3.2 GA P01
Affected: 4.0.0 to 4.2.8 or 4.0.0 to 4.3.3
Affected: 9.3.0 to 9.3.3 or 9.3.0 to 9.4.0
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:26:25.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst04191en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HP 3PAR StoreServ 10000 Storage; HP 3PAR StoreServ 7000 Storage; HPE 3PAR StoreServ 8000 Storage; HPE Primera 600 Storage; HPE 3PAR StoreServ 20000; HPE Alletra 9000; HPE 3PAR StoreServ 9000 Storage",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "3.3.1 MU1 up to 3.3.1 MU2 P157 or 3.3.1 up to 3.3.1 MU5 P156 or 3.3.1 MU1 up to 3.3.2 GA P01"
            },
            {
              "status": "affected",
              "version": "4.0.0 to 4.2.8 or 4.0.0 to 4.3.3"
            },
            {
              "status": "affected",
              "version": "9.3.0 to 9.3.3 or 9.3.0 to 9.4.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential security vulnerability has been identified in HPE 3PAR StoreServ, HPE Primera Storage and HPE Alletra 9000 Storage array firmware. An unauthenticated user could remotely exploit the low complexity issue to execute code as administrator. This vulnerability impacts completely the confidentiality, integrity, availability of the array. HPE has made the following software updates and mitigation information to resolve the vulnerability in 3PAR, Primera and Alletra 9000 firmware."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote arbitrary code execution",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-11T16:46:31.000Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst04191en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-26588",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HP 3PAR StoreServ 10000 Storage; HP 3PAR StoreServ 7000 Storage; HPE 3PAR StoreServ 8000 Storage; HPE Primera 600 Storage; HPE 3PAR StoreServ 20000; HPE Alletra 9000; HPE 3PAR StoreServ 9000 Storage",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "3.3.1 MU1 up to 3.3.1 MU2 P157 or 3.3.1 up to 3.3.1 MU5 P156 or 3.3.1 MU1 up to 3.3.2 GA P01"
                          },
                          {
                            "version_value": "3.3.1 MU1 up to 3.3.1 MU2 P157 or 3.3.1 up to 3.3.1 MU5 P156 or 3.3.1 MU1 up to 3.3.2 GA P01"
                          },
                          {
                            "version_value": "3.3.1 MU1 up to 3.3.1 MU2 P157 or 3.3.1 up to 3.3.1 MU5 P156 or 3.3.1 MU1 up to 3.3.2 GA P01"
                          },
                          {
                            "version_value": "4.0.0 to 4.2.8 or 4.0.0 to 4.3.3"
                          },
                          {
                            "version_value": "3.3.1 MU1 up to 3.3.1 MU2 P157 or 3.3.1 up to 3.3.1 MU5 P156 or 3.3.1 MU1 up to 3.3.2 GA P01"
                          },
                          {
                            "version_value": "9.3.0 to 9.3.3 or 9.3.0 to 9.4.0"
                          },
                          {
                            "version_value": "3.3.1 MU1 up to 3.3.1 MU2 P157 or 3.3.1 up to 3.3.1 MU5 P156 or 3.3.1 MU1 up to 3.3.2 GA P01"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential security vulnerability has been identified in HPE 3PAR StoreServ, HPE Primera Storage and HPE Alletra 9000 Storage array firmware. An unauthenticated user could remotely exploit the low complexity issue to execute code as administrator. This vulnerability impacts completely the confidentiality, integrity, availability of the array. HPE has made the following software updates and mitigation information to resolve the vulnerability in 3PAR, Primera and Alletra 9000 firmware."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote arbitrary code execution"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst04191en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst04191en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-26588",
    "datePublished": "2021-10-11T16:46:31.000Z",
    "dateReserved": "2021-02-02T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:26:25.484Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-26588",
      "date": "2026-06-23",
      "epss": "0.01755",
      "percentile": "0.75027"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:3par_os:3.3.1_mp5_p156:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EBA14C6B-DC85-4967-871D-995A214DF650\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:3par_os:3.3.1_mu1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0DA9430C-3E6A-4B41-8698-6B558B0E8D42\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:3par_os:3.3.1_mu2_p157:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9C5481A2-0E44-4D74-BEDF-AC645ECA538D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:3par_os:3.3.2_ga_p_01:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9C5B3494-DD68-4E7E-9B9A-44E8C5B883D8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:3par_storeserv_10400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B6CC3E21-536F-438C-B9BC-A9C965D4B1A0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:3par_storeserv_10800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8681B6DC-A597-49CE-8763-197D88394C58\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:3par_storeserv_20000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C5F433CD-74B1-4890-A9D7-16FC9AB1628B\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:3par_storeserv_7200c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BF319281-FEFD-4AC8-B05E-0EBD68F8DA01\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:3par_storeserv_7400c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4F9E5415-E4EA-42D4-8730-3399CEE3105E\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:3par_storeserv_7440c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"53AAF6FE-E50F-4CC1-BB86-F09A4046C48B\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:3par_storeserv_8000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"21765026-DACF-43E9-8B81-6AB502DE2027\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:3par_storeserv_9000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1B18B186-70B1-4696-ACCF-66384C7277D1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:primera_630_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"4.0.0\", \"versionEndIncluding\": \"4.3.3\", \"matchCriteriaId\": \"F09A1455-5CA7-4203-B03F-39A97000A485\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:primera_630:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BD9B90D0-A8EE-42F1-8A74-9450B53932C6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:primera_650_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"4.0.0\", \"versionEndIncluding\": \"4.3.3\", \"matchCriteriaId\": \"BAA5B481-1873-4F23-9ED8-EB4831953D2A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:primera_650:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FD31A941-0615-4F72-85FE-910ECDEF5AC1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:primera_670_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"4.0.0\", \"versionEndIncluding\": \"4.3.3\", \"matchCriteriaId\": \"1923BB7D-FAB9-4497-A939-8A3222AB77F3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:primera_670:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1608FC66-D97B-4726-8341-4D5F97FF92F7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:alletra_9060_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.3.0\", \"versionEndIncluding\": \"9.4.0\", \"matchCriteriaId\": \"8D7505F3-31EE-4E01-9EE4-B8878231E898\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:alletra_9060:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"73817B8A-351E-4008-8F06-2C4B6EA5D738\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hpe:alletra_9080_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.3.0\", \"versionEndIncluding\": \"9.4.0\", \"matchCriteriaId\": \"9FC96F77-9877-4999-8D0A-84966D41BB55\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hpe:alletra_9080:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"473D7C5D-81A8-4D75-BB9E-AE04A96742E6\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A potential security vulnerability has been identified in HPE 3PAR StoreServ, HPE Primera Storage and HPE Alletra 9000 Storage array firmware. An unauthenticated user could remotely exploit the low complexity issue to execute code as administrator. This vulnerability impacts completely the confidentiality, integrity, availability of the array. HPE has made the following software updates and mitigation information to resolve the vulnerability in 3PAR, Primera and Alletra 9000 firmware.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una posible vulnerabilidad de seguridad en el firmware de HPE 3PAR StoreServ, HPE Primera Storage and HPE Alletra 9000 Storage array. Un usuario no autenticado podr\\u00eda explotar remotamente el problema de baja complejidad para ejecutar c\\u00f3digo como administrador. Esta vulnerabilidad afecta completamente la confidencialidad, integridad y disponibilidad de la matriz. HPE ha realizado las siguientes actualizaciones de software e informaci\\u00f3n de mitigaci\\u00f3n para resolver la vulnerabilidad en el firmware de 3PAR, Primera y Alletra 9000\"}]",
      "id": "CVE-2021-26588",
      "lastModified": "2024-11-21T05:56:32.380",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-10-11T17:15:07.637",
      "references": "[{\"url\": \"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst04191en_us\", \"source\": \"security-alert@hpe.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst04191en_us\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "security-alert@hpe.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-26588\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2021-10-11T17:15:07.637\",\"lastModified\":\"2024-11-21T05:56:32.380\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A potential security vulnerability has been identified in HPE 3PAR StoreServ, HPE Primera Storage and HPE Alletra 9000 Storage array firmware. An unauthenticated user could remotely exploit the low complexity issue to execute code as administrator. This vulnerability impacts completely the confidentiality, integrity, availability of the array. HPE has made the following software updates and mitigation information to resolve the vulnerability in 3PAR, Primera and Alletra 9000 firmware.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una posible vulnerabilidad de seguridad en el firmware de HPE 3PAR StoreServ, HPE Primera Storage and HPE Alletra 9000 Storage array. Un usuario no autenticado podr\u00eda explotar remotamente el problema de baja complejidad para ejecutar c\u00f3digo como administrador. Esta vulnerabilidad afecta completamente la confidencialidad, integridad y disponibilidad de la matriz. HPE ha realizado las siguientes actualizaciones de software e informaci\u00f3n de mitigaci\u00f3n para resolver la vulnerabilidad en el firmware de 3PAR, Primera y Alletra 9000\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:3par_os:3.3.1_mp5_p156:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EBA14C6B-DC85-4967-871D-995A214DF650\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:3par_os:3.3.1_mu1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0DA9430C-3E6A-4B41-8698-6B558B0E8D42\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:3par_os:3.3.1_mu2_p157:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C5481A2-0E44-4D74-BEDF-AC645ECA538D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:3par_os:3.3.2_ga_p_01:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C5B3494-DD68-4E7E-9B9A-44E8C5B883D8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:3par_storeserv_10400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6CC3E21-536F-438C-B9BC-A9C965D4B1A0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:3par_storeserv_10800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8681B6DC-A597-49CE-8763-197D88394C58\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:3par_storeserv_20000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C5F433CD-74B1-4890-A9D7-16FC9AB1628B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:3par_storeserv_7200c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF319281-FEFD-4AC8-B05E-0EBD68F8DA01\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:3par_storeserv_7400c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F9E5415-E4EA-42D4-8730-3399CEE3105E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:3par_storeserv_7440c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"53AAF6FE-E50F-4CC1-BB86-F09A4046C48B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:3par_storeserv_8000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21765026-DACF-43E9-8B81-6AB502DE2027\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:3par_storeserv_9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B18B186-70B1-4696-ACCF-66384C7277D1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:primera_630_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0.0\",\"versionEndIncluding\":\"4.3.3\",\"matchCriteriaId\":\"F09A1455-5CA7-4203-B03F-39A97000A485\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:primera_630:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD9B90D0-A8EE-42F1-8A74-9450B53932C6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:primera_650_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0.0\",\"versionEndIncluding\":\"4.3.3\",\"matchCriteriaId\":\"BAA5B481-1873-4F23-9ED8-EB4831953D2A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:primera_650:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD31A941-0615-4F72-85FE-910ECDEF5AC1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:primera_670_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0.0\",\"versionEndIncluding\":\"4.3.3\",\"matchCriteriaId\":\"1923BB7D-FAB9-4497-A939-8A3222AB77F3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:primera_670:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1608FC66-D97B-4726-8341-4D5F97FF92F7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:alletra_9060_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.3.0\",\"versionEndIncluding\":\"9.4.0\",\"matchCriteriaId\":\"8D7505F3-31EE-4E01-9EE4-B8878231E898\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:alletra_9060:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"73817B8A-351E-4008-8F06-2C4B6EA5D738\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hpe:alletra_9080_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.3.0\",\"versionEndIncluding\":\"9.4.0\",\"matchCriteriaId\":\"9FC96F77-9877-4999-8D0A-84966D41BB55\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hpe:alletra_9080:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"473D7C5D-81A8-4D75-BB9E-AE04A96742E6\"}]}]}],\"references\":[{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst04191en_us\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbst04191en_us\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…