CVE-2021-22809 (GCVE-0-2021-22809)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.517Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:44", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22809", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22809", "datePublished": "2022-01-28T19:09:44", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.517Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-22809\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2022-01-28T20:15:09.933\",\"lastModified\":\"2024-11-21T05:50:42.767\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior\"},{\"lang\":\"es\",\"value\":\"Una CWE-125: Se presenta una vulnerabilidad de Lectura Fuera De L\u00edmites que podr\u00eda causar una divulgaci\u00f3n involuntaria de datos cuando es cargado un archivo de configuraci\u00f3n *.gd1 malicioso en la herramienta GUIcon. Producto afectado: Eurotherm by Schneider Electric GUIcon Versi\u00f3n 2.0 (Build 683.003) y anteriores\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:guicon:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.0\",\"matchCriteriaId\":\"12BF8CCC-2CA6-4C98-AD08-43120B8184BC\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
fkie_cve-2021-22809
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | guicon | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:guicon:*:*:*:*:*:*:*:*", "matchCriteriaId": "12BF8CCC-2CA6-4C98-AD08-43120B8184BC", "versionEndIncluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" }, { "lang": "es", "value": "Una CWE-125: Se presenta una vulnerabilidad de Lectura Fuera De L\u00edmites que podr\u00eda causar una divulgaci\u00f3n involuntaria de datos cuando es cargado un archivo de configuraci\u00f3n *.gd1 malicioso en la herramienta GUIcon. Producto afectado: Eurotherm by Schneider Electric GUIcon Versi\u00f3n 2.0 (Build 683.003) y anteriores" } ], "id": "CVE-2021-22809", "lastModified": "2024-11-21T05:50:42.767", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-01-28T20:15:09.933", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
ghsa-gx8q-f4px-p448
Vulnerability from github
A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
{ "affected": [], "aliases": [ "CVE-2021-22809" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-01-28T20:15:00Z", "severity": "MODERATE" }, "details": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior", "id": "GHSA-gx8q-f4px-p448", "modified": "2022-02-03T00:00:24Z", "published": "2022-01-29T00:00:46Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-22809" }, { "type": "WEB", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "schema_version": "1.4.0", "severity": [] }
gsd-2021-22809
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-22809", "description": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior", "id": "GSD-2021-22809" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-22809" ], "details": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior", "id": "GSD-2021-22809", "modified": "2023-12-13T01:23:24.820852Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22809", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:guicon:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.0", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22809" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } }, "lastModifiedDate": "2022-02-02T21:26Z", "publishedDate": "2022-01-28T20:15Z" } } }
ICSA-21-313-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael Heinzl" ], "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may allow an attacker to execute arbitrary code on the host PC, leading to sensitive information disclosure or unintended user actions.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-313-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-313-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-313-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-313-02" } ], "title": "Schneider Electric GUIcon", "tracking": { "current_release_date": "2021-11-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-313-02", "initial_release_date": "2021-11-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-09T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-313-02 Schneider Electric GUIcon" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 2.0 (Build 683.003) ", "product": { "name": "GUIcon: Versions 2.0 (Build 683.003) and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "GUIcon" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-22807", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "This vulnerability may cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool.CVE-2021-22807 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22807" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "The only known method for an attacker to exploit these vulnerabilities is to create a malicious GUIcon *.gd1 configuration file and then trick a user into opening it with the GUIcon software. The mitigation for these vulnerabilities is to ensure any GUIcon *.gd1 file loaded into the tool is from a trusted source.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-313-07", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "category": "mitigation", "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Install physical controls to prevent unauthorized personnel from accessing industrial control and safety systems, components, peripheral equipment, and networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never connect programming software to any network other than the network intended for that device.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Scan all methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/download/document/7EN52-0390/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22808", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "This vulnerability may cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool.CVE-2021-22808 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22808" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "The only known method for an attacker to exploit these vulnerabilities is to create a malicious GUIcon *.gd1 configuration file and then trick a user into opening it with the GUIcon software. The mitigation for these vulnerabilities is to ensure any GUIcon *.gd1 file loaded into the tool is from a trusted source.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-313-07", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "category": "mitigation", "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Install physical controls to prevent unauthorized personnel from accessing industrial control and safety systems, components, peripheral equipment, and networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never connect programming software to any network other than the network intended for that device.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Scan all methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/download/document/7EN52-0390/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22809", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "This vulnerability may cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool.CVE-2021-22809 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22809" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "The only known method for an attacker to exploit these vulnerabilities is to create a malicious GUIcon *.gd1 configuration file and then trick a user into opening it with the GUIcon software. The mitigation for these vulnerabilities is to ensure any GUIcon *.gd1 file loaded into the tool is from a trusted source.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-313-07", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "category": "mitigation", "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Install physical controls to prevent unauthorized personnel from accessing industrial control and safety systems, components, peripheral equipment, and networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never connect programming software to any network other than the network intended for that device.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Scan all methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/download/document/7EN52-0390/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
icsa-21-313-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael Heinzl" ], "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may allow an attacker to execute arbitrary code on the host PC, leading to sensitive information disclosure or unintended user actions.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "France", "title": "Company headquarters location" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-313-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-313-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-313-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-313-02" } ], "title": "Schneider Electric GUIcon", "tracking": { "current_release_date": "2021-11-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-313-02", "initial_release_date": "2021-11-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-09T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-313-02 Schneider Electric GUIcon" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 2.0 (Build 683.003) ", "product": { "name": "GUIcon: Versions 2.0 (Build 683.003) and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "GUIcon" } ], "category": "vendor", "name": "Schneider Electric Software, LLC" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-22807", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "This vulnerability may cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool.CVE-2021-22807 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22807" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "The only known method for an attacker to exploit these vulnerabilities is to create a malicious GUIcon *.gd1 configuration file and then trick a user into opening it with the GUIcon software. The mitigation for these vulnerabilities is to ensure any GUIcon *.gd1 file loaded into the tool is from a trusted source.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-313-07", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "category": "mitigation", "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Install physical controls to prevent unauthorized personnel from accessing industrial control and safety systems, components, peripheral equipment, and networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never connect programming software to any network other than the network intended for that device.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Scan all methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/download/document/7EN52-0390/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22808", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "This vulnerability may cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool.CVE-2021-22808 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22808" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "The only known method for an attacker to exploit these vulnerabilities is to create a malicious GUIcon *.gd1 configuration file and then trick a user into opening it with the GUIcon software. The mitigation for these vulnerabilities is to ensure any GUIcon *.gd1 file loaded into the tool is from a trusted source.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-313-07", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "category": "mitigation", "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Install physical controls to prevent unauthorized personnel from accessing industrial control and safety systems, components, peripheral equipment, and networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never connect programming software to any network other than the network intended for that device.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Scan all methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/download/document/7EN52-0390/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-22809", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "This vulnerability may cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool.CVE-2021-22809 has been assigned to this vulnerability. A CVSS v3 base score of 4.4 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22809" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "The only known method for an attacker to exploit these vulnerabilities is to create a malicious GUIcon *.gd1 configuration file and then trick a user into opening it with the GUIcon software. The mitigation for these vulnerabilities is to ensure any GUIcon *.gd1 file loaded into the tool is from a trusted source.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information about these issues, please refer to the original Schneider Electric publication SEVD-2021-313-07", "product_ids": [ "CSAFPID-0001" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "category": "mitigation", "details": "Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Install physical controls to prevent unauthorized personnel from accessing industrial control and safety systems, components, peripheral equipment, and networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never connect programming software to any network other than the network intended for that device.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Scan all methods of mobile data exchange with the isolated network, such as CDs, USB drives, etc., before use in the terminals or any node connected to these networks.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.se.com/us/en/download/document/7EN52-0390/" } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
CERTFR-2021-AVI-853
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
N/A | N/A | Momentum MDI (171CBU*), MC80 (BMKC8*), HART (BMEAH*) toutes versions | ||
N/A | N/A | versadac, toutes versions | ||
Schneider Electric | N/A | EPack toutes versions | ||
N/A | N/A | EPC2000 toutes versions | ||
N/A | N/A | Modicon M262 Logic Controllers firmware version 5.1.5.35 et antérieures | ||
N/A | N/A | SCD6000 Industrial RTU Version antérieures à SCD6000 is SY-1101211_Mand | ||
N/A | N/A | SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E et 357E RTUs avec le firmware V8.18.1 et antérieures | ||
N/A | N/A | NMC embedded devices | ||
N/A | N/A | BMENOC0321, BMENOC0301, BMENOC0311, BMENOS0300 toutes versions | ||
N/A | N/A | BMECRA31210, BMXCRA31200, BMXCRA31210, 140CRA31200, 140CRA31908 toutes versions | ||
Schneider Electric | N/A | Modicon M241/M251 Logic Controllers firmware version 5.1.9.21 et antérieures | ||
Symfony | process | EcoStruxure Process Expert versions antérieures à V2021 | ||
N/A | N/A | Tricon Communication Modules versions antérieures à 11.8 | ||
N/A | N/A | TelevisAir V3.0 Dongle BTLE (part number ADBT42* et antérieures) | ||
Schneider Electric | Modicon M340 | Modicon M580 CPU (BMEP* and BMEH*), Modicon M340 CPU (BMXP34*), BMXNOM0200 toutes versions | ||
Schneider Electric | N/A | Easy Harmony GXU (HMIGXU Series) et Easy Harmony ET6 (HMIET Series) Vijeo Designer Basic V1.2 family et antérieures | ||
Schneider Electric | N/A | T2750 PAC, toutes versions | ||
Schneider Electric | N/A | Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) et antérieures | ||
N/A | N/A | HMISTO Series HMISTU/S5T Series toutes versions | ||
Schneider Electric | N/A | TCSEGPA23F14F, BMECXM0100 toutes versions | ||
N/A | N/A | HMISCU,HMIGTU, HMIG2U, HMIG3U, HMIG3X, HMIGTO Series Vijeo Designer (V6.2 SP11) family et antérieures | ||
N/A | N/A | BMXNOE0100, BMXNOE0110, BMXNGD0100, BMXNOC0401 toutes versions | ||
N/A | N/A | Pro-face GP4100 Series, GP4000E Series, GP4000M Series toutes versions | ||
N/A | N/A | Pro-face SP-5B00, SP-5B10, SP-5B90, ST6000 Series (GP-ProEX model), ET6000 Series GP-Pro EX V4.09.300 et antérieures | ||
N/A | N/A | Momentum ENT (170ENT11*) toutes versions | ||
Schneider Electric | N/A | nanodac toutes versions | ||
Schneider Electric | N/A | Network Management Card 2 (NMC2) | ||
Schneider Electric | N/A | Schneider Electric Software Update, V2.3.0 à V2.5.1 | ||
N/A | N/A | Network Management Card 3 (NMC3) | ||
N/A | N/A | 6100A, 6180A, 6100XIO, 6180XIO, AeroDAQ toutes versions | ||
Schneider Electric | N/A | BMXNOM0200 toutes versions | ||
N/A | N/A | BMENOP0300, BMXNOR0200 toutes versions | ||
Schneider Electric | N/A | Modicon LMC078 toutes versions | ||
Schneider Electric | N/A | E+PLC400 toutes versions | ||
N/A | N/A | Pro-face GP4000 Series, LT4000M Series, GP4000H Series GP-Pro EX V4.09.300 et antérieures |
Title | Publication Time | Tags | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Momentum MDI (171CBU*), MC80 (BMKC8*), HART (BMEAH*) toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "versadac, toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "EPack toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EPC2000 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon M262 Logic Controllers firmware version 5.1.5.35 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "SCD6000 Industrial RTU Version ant\u00e9rieures \u00e0 SCD6000 is SY-1101211_Mand", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E et 357E RTUs avec le firmware V8.18.1 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "NMC embedded devices", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "BMENOC0321, BMENOC0301, BMENOC0311, BMENOS0300 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "BMECRA31210, BMXCRA31200, BMXCRA31210, 140CRA31200, 140CRA31908 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon M241/M251 Logic Controllers firmware version 5.1.9.21 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure Process Expert versions ant\u00e9rieures \u00e0 V2021", "product": { "name": "process", "vendor": { "name": "Symfony", "scada": false } } }, { "description": "Tricon Communication Modules versions ant\u00e9rieures \u00e0 11.8", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "TelevisAir V3.0 Dongle BTLE (part number ADBT42* et ant\u00e9rieures)", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon M580 CPU (BMEP* and BMEH*), Modicon M340 CPU (BMXP34*), BMXNOM0200 toutes versions", "product": { "name": "Modicon M340", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Easy Harmony GXU (HMIGXU Series) et Easy Harmony ET6 (HMIET Series) Vijeo Designer Basic V1.2 family et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "T2750 PAC, toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "HMISTO Series HMISTU/S5T Series toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "TCSEGPA23F14F, BMECXM0100 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "HMISCU,HMIGTU, HMIG2U, HMIG3U, HMIG3X, HMIGTO Series Vijeo Designer (V6.2 SP11) family et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "BMXNOE0100, BMXNOE0110, BMXNGD0100, BMXNOC0401 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Pro-face GP4100 Series, GP4000E Series, GP4000M Series toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Pro-face SP-5B00, SP-5B10, SP-5B90, ST6000 Series (GP-ProEX model), ET6000 Series GP-Pro EX V4.09.300 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Momentum ENT (170ENT11*) toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "nanodac toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Network Management Card 2 (NMC2)", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Schneider Electric Software Update, V2.3.0 \u00e0 V2.5.1", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Network Management Card 3 (NMC3)", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "6100A, 6180A, 6100XIO, 6180XIO, AeroDAQ toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "BMXNOM0200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "BMENOP0300, BMXNOR0200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon LMC078 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "E+PLC400 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Pro-face GP4000 Series, LT4000M Series, GP4000H Series GP-Pro EX V4.09.300 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-22808", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22808" }, { "name": "CVE-2021-34527", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34527" }, { "name": "CVE-2021-22811", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22811" }, { "name": "CVE-2021-22813", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22813" }, { "name": "CVE-2020-35198", "url": "https://www.cve.org/CVERecord?id=CVE-2020-35198" }, { "name": "CVE-2021-22807", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22807" }, { "name": "CVE-2021-22810", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22810" }, { "name": "CVE-2021-22815", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22815" }, { "name": "CVE-2021-1675", "url": "https://www.cve.org/CVERecord?id=CVE-2021-1675" }, { "name": "CVE-2021-22812", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22812" }, { "name": "CVE-2021-22809", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22809" }, { "name": "CVE-2021-22814", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22814" }, { "name": "CVE-2020-28895", "url": "https://www.cve.org/CVERecord?id=CVE-2020-28895" }, { "name": "CVE-2021-22799", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22799" }, { "name": "CVE-2021-22816", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22816" } ], "initial_release_date": "2021-11-09T00:00:00", "last_revision_date": "2021-11-09T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-853", "revisions": [ { "description": "Version initiale", "revision_date": "2021-11-09T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-07 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-01 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-06 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-06" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-04 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-04" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-02 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-03 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ] }
cnvd-2022-08934
Vulnerability from cnvd
目前厂商已发布升级补丁以修复漏洞,补丁获取链接: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07
Name | Schneider Electric guicon <=2.0 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2021-22809" } }, "description": "Schneider Electric Eurotherm by Schneider Electric GUIcon\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u5957\u56fe\u5f62\u7528\u6237\u754c\u9762\u7f16\u7a0b\u8f6f\u4ef6\u3002\n\nSchneider Electric Eurotherm by Schneider Electric GUIcon\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5f53\u6076\u610f*.gd1\u914d\u7f6e\u6587\u4ef6\u52a0\u8f7d\u5230GUIcon\u5de5\u5177\u4e2d\u65f6\uff0c\u8be5\u6f0f\u6d1e\u53ef\u80fd\u5bfc\u81f4\u4efb\u610f\u4ee3\u7801\u6267\u884c\u3002 \u76ee\u524d\u6ca1\u6709\u8be6\u7ec6\u7684\u6f0f\u6d1e\u7ec6\u8282\u63d0\u4f9b\u3002", "formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u53d1\u5e03\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6f0f\u6d1e\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a\r\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2022-08934", "openTime": "2022-02-09", "patchDescription": "Schneider Electric Eurotherm by Schneider Electric GUIcon\u662f\u6cd5\u56fd\u65bd\u8010\u5fb7\u7535\u6c14\uff08Schneider Electric\uff09\u516c\u53f8\u7684\u4e00\u5957\u56fe\u5f62\u7528\u6237\u754c\u9762\u7f16\u7a0b\u8f6f\u4ef6\u3002\r\n\r\nSchneider Electric Eurotherm by Schneider Electric GUIcon\u5b58\u5728\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5f53\u6076\u610f*.gd1\u914d\u7f6e\u6587\u4ef6\u52a0\u8f7d\u5230GUIcon\u5de5\u5177\u4e2d\u65f6\uff0c\u8be5\u6f0f\u6d1e\u53ef\u80fd\u5bfc\u81f4\u4efb\u610f\u4ee3\u7801\u6267\u884c\u3002\u76ee\u524d\u6ca1\u6709\u8be6\u7ec6\u7684\u6f0f\u6d1e\u7ec6\u8282\u63d0\u4f9b\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Schneider Electric Eurotherm by Schneider Electric GUIcon\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2022-08934\uff09\u7684\u8865\u4e01", "products": { "product": "Schneider Electric guicon \u003c=2.0" }, "referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2021-22809", "serverity": "\u4e2d", "submitTime": "2021-11-11", "title": "Schneider Electric Eurotherm by Schneider Electric GUIcon\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2022-08934\uff09" }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.