Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
Vendor | Product | Description | ||
---|---|---|---|---|
N/A | N/A | Momentum MDI (171CBU*), MC80 (BMKC8*), HART (BMEAH*) toutes versions | ||
N/A | N/A | versadac, toutes versions | ||
Schneider Electric | N/A | EPack toutes versions | ||
N/A | N/A | EPC2000 toutes versions | ||
N/A | N/A | Modicon M262 Logic Controllers firmware version 5.1.5.35 et antérieures | ||
N/A | N/A | SCD6000 Industrial RTU Version antérieures à SCD6000 is SY-1101211_Mand | ||
N/A | N/A | SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E et 357E RTUs avec le firmware V8.18.1 et antérieures | ||
N/A | N/A | NMC embedded devices | ||
N/A | N/A | BMENOC0321, BMENOC0301, BMENOC0311, BMENOS0300 toutes versions | ||
N/A | N/A | BMECRA31210, BMXCRA31200, BMXCRA31210, 140CRA31200, 140CRA31908 toutes versions | ||
Schneider Electric | N/A | Modicon M241/M251 Logic Controllers firmware version 5.1.9.21 et antérieures | ||
Symfony | process | EcoStruxure Process Expert versions antérieures à V2021 | ||
N/A | N/A | Tricon Communication Modules versions antérieures à 11.8 | ||
N/A | N/A | TelevisAir V3.0 Dongle BTLE (part number ADBT42* et antérieures) | ||
Schneider Electric | Modicon M340 | Modicon M580 CPU (BMEP* and BMEH*), Modicon M340 CPU (BMXP34*), BMXNOM0200 toutes versions | ||
Schneider Electric | N/A | Easy Harmony GXU (HMIGXU Series) et Easy Harmony ET6 (HMIET Series) Vijeo Designer Basic V1.2 family et antérieures | ||
Schneider Electric | N/A | T2750 PAC, toutes versions | ||
Schneider Electric | N/A | Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) et antérieures | ||
N/A | N/A | HMISTO Series HMISTU/S5T Series toutes versions | ||
Schneider Electric | N/A | TCSEGPA23F14F, BMECXM0100 toutes versions | ||
N/A | N/A | HMISCU,HMIGTU, HMIG2U, HMIG3U, HMIG3X, HMIGTO Series Vijeo Designer (V6.2 SP11) family et antérieures | ||
N/A | N/A | BMXNOE0100, BMXNOE0110, BMXNGD0100, BMXNOC0401 toutes versions | ||
N/A | N/A | Pro-face GP4100 Series, GP4000E Series, GP4000M Series toutes versions | ||
N/A | N/A | Pro-face SP-5B00, SP-5B10, SP-5B90, ST6000 Series (GP-ProEX model), ET6000 Series GP-Pro EX V4.09.300 et antérieures | ||
N/A | N/A | Momentum ENT (170ENT11*) toutes versions | ||
Schneider Electric | N/A | nanodac toutes versions | ||
Schneider Electric | N/A | Network Management Card 2 (NMC2) | ||
Schneider Electric | N/A | Schneider Electric Software Update, V2.3.0 à V2.5.1 | ||
N/A | N/A | Network Management Card 3 (NMC3) | ||
N/A | N/A | 6100A, 6180A, 6100XIO, 6180XIO, AeroDAQ toutes versions | ||
Schneider Electric | N/A | BMXNOM0200 toutes versions | ||
N/A | N/A | BMENOP0300, BMXNOR0200 toutes versions | ||
Schneider Electric | N/A | Modicon LMC078 toutes versions | ||
Schneider Electric | N/A | E+PLC400 toutes versions | ||
N/A | N/A | Pro-face GP4000 Series, LT4000M Series, GP4000H Series GP-Pro EX V4.09.300 et antérieures |
References
Title | Publication Time | Tags | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Momentum MDI (171CBU*), MC80 (BMKC8*), HART (BMEAH*) toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "versadac, toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "EPack toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EPC2000 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon M262 Logic Controllers firmware version 5.1.5.35 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "SCD6000 Industrial RTU Version ant\u00e9rieures \u00e0 SCD6000 is SY-1101211_Mand", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E et 357E RTUs avec le firmware V8.18.1 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "NMC embedded devices", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "BMENOC0321, BMENOC0301, BMENOC0311, BMENOS0300 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "BMECRA31210, BMXCRA31200, BMXCRA31210, 140CRA31200, 140CRA31908 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon M241/M251 Logic Controllers firmware version 5.1.9.21 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "EcoStruxure Process Expert versions ant\u00e9rieures \u00e0 V2021", "product": { "name": "process", "vendor": { "name": "Symfony", "scada": false } } }, { "description": "Tricon Communication Modules versions ant\u00e9rieures \u00e0 11.8", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "TelevisAir V3.0 Dongle BTLE (part number ADBT42* et ant\u00e9rieures)", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon M580 CPU (BMEP* and BMEH*), Modicon M340 CPU (BMXP34*), BMXNOM0200 toutes versions", "product": { "name": "Modicon M340", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Easy Harmony GXU (HMIGXU Series) et Easy Harmony ET6 (HMIET Series) Vijeo Designer Basic V1.2 family et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "T2750 PAC, toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "HMISTO Series HMISTU/S5T Series toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "TCSEGPA23F14F, BMECXM0100 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "HMISCU,HMIGTU, HMIG2U, HMIG3U, HMIG3X, HMIGTO Series Vijeo Designer (V6.2 SP11) family et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "BMXNOE0100, BMXNOE0110, BMXNGD0100, BMXNOC0401 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Pro-face GP4100 Series, GP4000E Series, GP4000M Series toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Pro-face SP-5B00, SP-5B10, SP-5B90, ST6000 Series (GP-ProEX model), ET6000 Series GP-Pro EX V4.09.300 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Momentum ENT (170ENT11*) toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "nanodac toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Network Management Card 2 (NMC2)", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Schneider Electric Software Update, V2.3.0 \u00e0 V2.5.1", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Network Management Card 3 (NMC3)", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "6100A, 6180A, 6100XIO, 6180XIO, AeroDAQ toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "BMXNOM0200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "BMENOP0300, BMXNOR0200 toutes versions", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } }, { "description": "Modicon LMC078 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "E+PLC400 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Schneider Electric", "scada": true } } }, { "description": "Pro-face GP4000 Series, LT4000M Series, GP4000H Series GP-Pro EX V4.09.300 et ant\u00e9rieures", "product": { "name": "N/A", "vendor": { "name": "N/A", "scada": false } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2021-22808", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22808" }, { "name": "CVE-2021-34527", "url": "https://www.cve.org/CVERecord?id=CVE-2021-34527" }, { "name": "CVE-2021-22811", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22811" }, { "name": "CVE-2021-22813", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22813" }, { "name": "CVE-2020-35198", "url": "https://www.cve.org/CVERecord?id=CVE-2020-35198" }, { "name": "CVE-2021-22807", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22807" }, { "name": "CVE-2021-22810", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22810" }, { "name": "CVE-2021-22815", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22815" }, { "name": "CVE-2021-1675", "url": "https://www.cve.org/CVERecord?id=CVE-2021-1675" }, { "name": "CVE-2021-22812", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22812" }, { "name": "CVE-2021-22809", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22809" }, { "name": "CVE-2021-22814", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22814" }, { "name": "CVE-2020-28895", "url": "https://www.cve.org/CVERecord?id=CVE-2020-28895" }, { "name": "CVE-2021-22799", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22799" }, { "name": "CVE-2021-22816", "url": "https://www.cve.org/CVERecord?id=CVE-2021-22816" } ], "initial_release_date": "2021-11-09T00:00:00", "last_revision_date": "2021-11-09T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-853", "revisions": [ { "description": "Version initiale", "revision_date": "2021-11-09T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-07 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-01 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-06 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-06" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-04 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-04" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-02 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-03 du 9 novembre 2021", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ] }
CVE-2021-22812 (GCVE-0-2021-22812)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.609Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:46", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22812", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22812", "datePublished": "2022-01-28T19:09:46", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.609Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22799 (GCVE-0-2021-22799)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.475Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:41", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22799", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22799", "datePublished": "2022-01-28T19:09:42", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.475Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-35198 (GCVE-0-2020-35198)
Vulnerability from cvelistv5
Published
2021-05-12 10:55
Modified
2024-08-04 17:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
References
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:02:06.842Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-19T23:22:42", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35198", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Wind River VxWorks 7. The memory allocator has a possible integer overflow in calculating a memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=security-notices", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-35198" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2022.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35198", "datePublished": "2021-05-12T10:55:47", "dateReserved": "2020-12-12T00:00:00", "dateUpdated": "2024-08-04T17:02:06.842Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22810 (GCVE-0-2021-22810)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.458Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:44", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22810", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22810", "datePublished": "2022-01-28T19:09:44", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.458Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22811 (GCVE-0-2021-22811)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.457Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:45", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22811", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22811", "datePublished": "2022-01-28T19:09:45", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.457Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-34527 (GCVE-0-2021-34527)
Vulnerability from cvelistv5
Published
2021-07-02 21:25
Modified
2025-07-30 01:38
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Remote Code Execution
Summary
<p>A remote code execution vulnerability exists when the Windows Print Spooler service improperly performs privileged file operations. An attacker who successfully exploited this vulnerability could run arbitrary code with SYSTEM privileges. An attacker could then install programs; view, change, or delete data; or create new accounts with full user rights.</p>
<p>UPDATE July 7, 2021: The security update for Windows Server 2012, Windows Server 2016 and Windows 10, Version 1607 have been released. Please see the Security Updates table for the applicable update for your system. We recommend that you install these updates immediately. If you are unable to install these updates, see the FAQ and Workaround sections in this CVE for information on how to help protect your system from this vulnerability.</p>
<p>In addition to installing the updates, in order to secure your system, you must confirm that the following registry settings are set to 0 (zero) or are not defined (<strong>Note</strong>: These registry keys do not exist by default, and therefore are already at the secure setting.), also that your Group Policy setting are correct (see FAQ):</p>
<ul>
<li>HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Microsoft\Windows NT\Printers\PointAndPrint</li>
<li>NoWarningNoElevationOnInstall = 0 (DWORD) or not defined (default setting)</li>
<li>UpdatePromptSettings = 0 (DWORD) or not defined (default setting)</li>
</ul>
<p><strong>Having NoWarningNoElevationOnInstall set to 1 makes your system vulnerable by design.</strong></p>
<p>UPDATE July 6, 2021: Microsoft has completed the investigation and has released security updates to address this vulnerability. Please see the Security Updates table for the applicable update for your system. We recommend that you install these updates immediately. If you are unable to install these updates, see the FAQ and Workaround sections in this CVE for information on how to help protect your system from this vulnerability. See also <a href="https://support.microsoft.com/topic/31b91c02-05bc-4ada-a7ea-183b129578a7">KB5005010: Restricting installation of new printer drivers after applying the July 6, 2021 updates</a>.</p>
<p>Note that the security updates released on and after July 6, 2021 contain protections for CVE-2021-1675 and the additional remote code execution exploit in the Windows Print Spooler service known as “PrintNightmare”, documented in CVE-2021-34527.</p>
References
URL | Tags | |
---|---|---|
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft | Windows 10 Version 1809 |
Version: 10.0.0 < 10.0.17763.2029 cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.2029:*:*:*:*:*:x86:* cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.2029:*:*:*:*:*:x64:* cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.2029:*:*:*:*:*:arm64:* |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2021-34527", "options": [ { "Exploitation": "active" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-01-24T16:04:14.042095Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2021-11-03", "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-34527" }, "type": "kev" } } ], "providerMetadata": { "dateUpdated": "2025-07-30T01:38:07.359Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2021-11-03T00:00:00+00:00", "value": "CVE-2021-34527 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2025-04-16T15:43:25.216Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "url": "https://www.vicarius.io/vsociety/posts/cve-2021-34527-printnightmare-detection-script" }, { "url": "https://www.vicarius.io/vsociety/posts/cve-2021-34527-printnightmare-mitigation-script" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://portal.msrc.microsoft.com/en-US/security-guidance/advisory/CVE-2021-34527" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/167261/Print-Spooler-Remote-DLL-Injection.html" } ], "title": "CVE Program Container", "x_generator": { "engine": "ADPogram 0.0.1" } } ], "cna": { "affected": [ { "cpes": [ "cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.2029:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.2029:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.2029:*:*:*:*:*:arm64:*" ], "platforms": [ "32-bit Systems", "x64-based Systems", "ARM64-based Systems" ], "product": "Windows 10 Version 1809", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.17763.2029", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2019:10.0.17763.2029:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2019", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.17763.2029", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2019:10.0.17763.2029:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2019 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.17763.2029", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2022:10.0.20348.230:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2022", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.20348.230", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_20H2:10.0.19042.1083:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_20H2:10.0.19042.1083:*:*:*:*:*:arm64:*" ], "platforms": [ "32-bit Systems", "ARM64-based Systems" ], "product": "Windows 10 Version 20H2", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19042.1083", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_20H2:10.0.19042.1083:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server version 20H2", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19042.1083", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_11_21H2:10.0.22000.318:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_11_21H2:10.0.22000.318:*:*:*:*:*:arm64:*" ], "platforms": [ "x64-based Systems", "ARM64-based Systems" ], "product": "Windows 11 version 21H2", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.22000.318", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_21H2:10.0.19044.1415:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_21H2:10.0.19044.1415:*:*:*:*:*:arm64:*", "cpe:2.3:o:microsoft:windows_10_21H2:10.0.19044.1415:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems", "ARM64-based Systems" ], "product": "Windows 10 Version 21H2", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19044.1415", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_11_22H2:10.0.22621.674:*:*:*:*:*:arm64:*", "cpe:2.3:o:microsoft:windows_11_22H2:10.0.22621.674:*:*:*:*:*:x64:*" ], "platforms": [ "ARM64-based Systems", "x64-based Systems" ], "product": "Windows 11 version 22H2", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.22621.674", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_22H2:10.0.19045.2251:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_10_22H2:10.0.19045.2251:*:*:*:*:*:arm64:*", "cpe:2.3:o:microsoft:windows_10_22H2:10.0.19045.2251:*:*:*:*:*:x86:*" ], "platforms": [ "x64-based Systems", "ARM64-based Systems", "32-bit Systems" ], "product": "Windows 10 Version 22H2", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19045.2251", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_1507:10.0.10240.18969:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_1507:10.0.10240.18969:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems", "x64-based Systems" ], "product": "Windows 10 Version 1507", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.10240.18969", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_1607:10.0.14393.4470:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_1607:10.0.14393.4470:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems", "x64-based Systems" ], "product": "Windows 10 Version 1607", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.14393.4470", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2016:10.0.14393.4470:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2016", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.14393.4470", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2016:10.0.14393.4470:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2016 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.14393.4470", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_rt_8.1:6.3.9600.20046:*:*:*:*:*:*:*" ], "platforms": [ "ARM64-based Systems" ], "product": "Windows 8.1", "vendor": "Microsoft", "versions": [ { "lessThan": "6.3.9600.20046", "status": "affected", "version": "6.3.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_sp2:6.0.6003.21138:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems" ], "product": "Windows Server 2008 Service Pack 2", "vendor": "Microsoft", "versions": [ { "lessThan": "6.0.6003.21138", "status": "affected", "version": "6.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_sp2:6.0.6003.21138:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_server_2008_sp2:6.0.6003.21138:*:*:*:*:*:x86:*" ], "platforms": [ "32-bit Systems", "x64-based Systems" ], "product": "Windows Server 2008 Service Pack 2 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "6.0.6003.21138", "status": "affected", "version": "6.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_sp2:6.0.6003.21138:*:*:*:*:*:x86:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2008 Service Pack 2", "vendor": "Microsoft", "versions": [ { "lessThan": "6.0.6003.21138", "status": "affected", "version": "6.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_R2:6.1.7601.25633:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2008 R2 Service Pack 1", "vendor": "Microsoft", "versions": [ { "lessThan": "6.1.7601.25633", "status": "affected", "version": "6.1.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_R2:6.1.7601.25633:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2008 R2 Service Pack 1 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "6.1.7601.25633", "status": "affected", "version": "6.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2012:6.2.9200.23383:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2012", "vendor": "Microsoft", "versions": [ { "lessThan": "6.2.9200.23383", "status": "affected", "version": "6.2.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2012:6.2.9200.23383:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2012 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "6.2.9200.23383", "status": "affected", "version": "6.2.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2012_R2:6.3.9600.20046:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2012 R2", "vendor": "Microsoft", "versions": [ { "lessThan": "6.3.9600.20046", "status": "affected", "version": "6.3.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2012_R2:6.3.9600.20046:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2012 R2 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "6.3.9600.20046", "status": "affected", "version": "6.3.0", "versionType": "custom" } ] } ], "datePublic": "2021-07-01T07:00:00.000Z", "descriptions": [ { "lang": "en-US", "value": "\u003cp\u003eA remote code execution vulnerability exists when the Windows Print Spooler service improperly performs privileged file operations. An attacker who successfully exploited this vulnerability could run arbitrary code with SYSTEM privileges. An attacker could then install programs; view, change, or delete data; or create new accounts with full user rights.\u003c/p\u003e\n\u003cp\u003eUPDATE July 7, 2021: The security update for Windows Server 2012, Windows Server 2016 and Windows 10, Version 1607 have been released. Please see the Security Updates table for the applicable update for your system. We recommend that you install these updates immediately. If you are unable to install these updates, see the FAQ and Workaround sections in this CVE for information on how to help protect your system from this vulnerability.\u003c/p\u003e\n\u003cp\u003eIn addition to installing the updates, in order to secure your system, you must confirm that the following registry settings are set to 0 (zero) or are not defined (\u003cstrong\u003eNote\u003c/strong\u003e: These registry keys do not exist by default, and therefore are already at the secure setting.), also that your Group Policy setting are correct (see FAQ):\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eHKEY_LOCAL_MACHINE\\SOFTWARE\\Policies\\Microsoft\\Windows NT\\Printers\\PointAndPrint\u003c/li\u003e\n\u003cli\u003eNoWarningNoElevationOnInstall = 0 (DWORD) or not defined (default setting)\u003c/li\u003e\n\u003cli\u003eUpdatePromptSettings = 0 (DWORD) or not defined (default setting)\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHaving NoWarningNoElevationOnInstall set to 1 makes your system vulnerable by design.\u003c/strong\u003e\u003c/p\u003e\n\u003cp\u003eUPDATE July 6, 2021: Microsoft has completed the investigation and has released security updates to address this vulnerability. Please see the Security Updates table for the applicable update for your system. We recommend that you install these updates immediately. If you are unable to install these updates, see the FAQ and Workaround sections in this CVE for information on how to help protect your system from this vulnerability. See also \u003ca href=\"https://support.microsoft.com/topic/31b91c02-05bc-4ada-a7ea-183b129578a7\"\u003eKB5005010: Restricting installation of new printer drivers after applying the July 6, 2021 updates\u003c/a\u003e.\u003c/p\u003e\n\u003cp\u003eNote that the security updates released on and after July 6, 2021 contain protections for CVE-2021-1675 and the additional remote code execution exploit in the Windows Print Spooler service known as \u201cPrintNightmare\u201d, documented in CVE-2021-34527.\u003c/p\u003e\n" } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:O/RC:C", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en-US", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "Remote Code Execution", "lang": "en-US", "type": "Impact" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-28T22:37:17.773Z", "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8", "shortName": "microsoft" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://portal.msrc.microsoft.com/en-US/security-guidance/advisory/CVE-2021-34527" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/167261/Print-Spooler-Remote-DLL-Injection.html" } ], "title": "Windows Print Spooler Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8", "assignerShortName": "microsoft", "cveId": "CVE-2021-34527", "datePublished": "2021-07-02T21:25:11.000Z", "dateReserved": "2021-06-09T00:00:00.000Z", "dateUpdated": "2025-07-30T01:38:07.359Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22809 (GCVE-0-2021-22809)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.517Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:44", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22809", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22809", "datePublished": "2022-01-28T19:09:44", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.517Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22813 (GCVE-0-2021-22813)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.536Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:47", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22813", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22813", "datePublished": "2022-01-28T19:09:47", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.536Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22816 (GCVE-0-2021-22816)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.524Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:41", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22816", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E, 337E, 350E and 357E RTUs with firmware V8.18.1 and prior" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22816", "datePublished": "2022-01-28T19:09:41", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.524Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22807 (GCVE-0-2021-22807)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.471Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:42", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22807", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22807", "datePublished": "2022-01-28T19:09:42", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.471Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22814 (GCVE-0-2021-22814)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.480Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:48", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22814", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22814", "datePublished": "2022-01-28T19:09:48", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.480Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-1675 (GCVE-0-2021-1675)
Vulnerability from cvelistv5
Published
2021-06-08 22:46
Modified
2025-07-30 01:38
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Elevation of Privilege
Summary
Windows Print Spooler Remote Code Execution Vulnerability
References
URL | Tags | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Microsoft | Windows 10 Version 1809 |
Version: 10.0.0 < 10.0.17763.1999 cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.1999:*:*:*:*:*:x86:* cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.1999:*:*:*:*:*:x64:* cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.1999:*:*:*:*:*:arm64:* |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2021-1675", "options": [ { "Exploitation": "active" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-20T19:19:04.437235Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2021-11-03", "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-1675" }, "type": "kev" } } ], "providerMetadata": { "dateUpdated": "2025-07-30T01:38:09.160Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2021-11-03T00:00:00+00:00", "value": "CVE-2021-1675 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-03T16:18:11.042Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://portal.msrc.microsoft.com/en-US/security-guidance/advisory/CVE-2021-1675" }, { "name": "VU#383432", "tags": [ "third-party-advisory", "x_refsource_CERT-VN", "x_transferred" ], "url": "https://www.kb.cert.org/vuls/id/383432" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/163349/Microsoft-PrintNightmare-Proof-Of-Concept.html" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/163351/PrintNightmare-Windows-Spooler-Service-Remote-Code-Execution.html" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/167261/Print-Spooler-Remote-DLL-Injection.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "cpes": [ "cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.1999:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.1999:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_10_1809:10.0.17763.1999:*:*:*:*:*:arm64:*" ], "platforms": [ "32-bit Systems", "x64-based Systems", "ARM64-based Systems" ], "product": "Windows 10 Version 1809", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.17763.1999", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2019:10.0.17763.1999:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2019", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.17763.1999", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2019:10.0.17763.1999:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2019 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.17763.1999", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_1909:10.0.18363.1621:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_1909:10.0.18363.1621:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_10_1809:10.0.18363.1621:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems", "x64-based Systems", "ARM64-based Systems" ], "product": "Windows 10 Version 1909", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.18363.1621", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_21H1:10.0.19043.1052:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_10_21H1:10.0.19043.1052:*:*:*:*:*:arm64:*", "cpe:2.3:o:microsoft:windows_10_21H1:10.0.19043.1052:*:*:*:*:*:x86:*" ], "platforms": [ "x64-based Systems", "ARM64-based Systems", "32-bit Systems" ], "product": "Windows 10 Version 21H1", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19043.1052", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_1809:10.0.19041.1052:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems", "ARM64-based Systems", "x64-based Systems" ], "product": "Windows 10 Version 2004", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19041.1052", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2004:10.0.19041.1052:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server version 2004", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19041.1052", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_20H2:10.0.19042.1052:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_20H2:10.0.19042.1052:*:*:*:*:*:arm64:*" ], "platforms": [ "32-bit Systems", "ARM64-based Systems" ], "product": "Windows 10 Version 20H2", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19042.1052", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_20H2:10.0.19042.1052:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server version 20H2", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.19042.1052", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_1507:10.0.10240.18967:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_1507:10.0.10240.18967:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems", "x64-based Systems" ], "product": "Windows 10 Version 1507", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.10240.18967", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_10_1607:10.0.14393.4467:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_10_1607:10.0.14393.4467:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems", "x64-based Systems" ], "product": "Windows 10 Version 1607", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.14393.4467", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2016:10.0.14393.4467:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2016", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.14393.4467", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2016:10.0.14393.4467:*:*:*:*:*:*:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2016 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "10.0.14393.4467", "status": "affected", "version": "10.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_7:6.1.7601.25632:sp1:*:*:*:*:x86:*" ], "platforms": [ "32-bit Systems" ], "product": "Windows 7", "vendor": "Microsoft", "versions": [ { "lessThan": "6.1.7601.25632", "status": "affected", "version": "6.1.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_7:6.1.7601.25632:sp1:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows 7 Service Pack 1", "vendor": "Microsoft", "versions": [ { "lessThan": "6.1.7601.25632", "status": "affected", "version": "6.1.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_8.1:6.3.9600.20045:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_8.1:6.3.9600.20044:*:*:*:*:*:x86:*", "cpe:2.3:o:microsoft:windows_8.1:6.3.9600.20045:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_8.1:6.3.9600.20044:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_rt_8.1:6.3.9600.20045:*:*:*:*:*:*:*" ], "platforms": [ "32-bit Systems", "x64-based Systems", "ARM64-based Systems" ], "product": "Windows 8.1", "vendor": "Microsoft", "versions": [ { "lessThan": "6.3.9600.20045", "status": "affected", "version": "6.3.0", "versionType": "custom" }, { "lessThan": "6.3.9600.20044", "status": "affected", "version": "6.3.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_sp2:6.0.6003.21137:*:*:*:*:*:x64:*" ], "platforms": [ "32-bit Systems" ], "product": "Windows Server 2008 Service Pack 2", "vendor": "Microsoft", "versions": [ { "lessThan": "6.0.6003.21137", "status": "affected", "version": "6.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_sp2:6.0.6003.21137:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_server_2008_sp2:6.0.6003.21137:*:*:*:*:*:x86:*" ], "platforms": [ "32-bit Systems", "x64-based Systems" ], "product": "Windows Server 2008 Service Pack 2 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "6.0.6003.21137", "status": "affected", "version": "6.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_sp2:6.0.6003.21137:*:*:*:*:*:x86:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2008 Service Pack 2", "vendor": "Microsoft", "versions": [ { "lessThan": "6.0.6003.21137", "status": "affected", "version": "6.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_R2:6.1.7601.25632:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2008 R2 Service Pack 1", "vendor": "Microsoft", "versions": [ { "lessThan": "6.1.7601.25632", "status": "affected", "version": "6.1.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2008_R2:6.1.7601.25632:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2008 R2 Service Pack 1 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "6.1.7601.25632", "status": "affected", "version": "6.0.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2012:6.2.9200.23372:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2012", "vendor": "Microsoft", "versions": [ { "lessThan": "6.2.9200.23372", "status": "affected", "version": "6.2.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2012:6.2.9200.23372:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2012 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "6.2.9200.23372", "status": "affected", "version": "6.2.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2012_R2:6.3.9600.20045:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_server_2012_R2:6.3.9600.20044:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2012 R2", "vendor": "Microsoft", "versions": [ { "lessThan": "6.3.9600.20045", "status": "affected", "version": "6.3.0", "versionType": "custom" }, { "lessThan": "6.3.9600.20044", "status": "affected", "version": "6.3.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:microsoft:windows_server_2012_R2:6.3.9600.20045:*:*:*:*:*:x64:*", "cpe:2.3:o:microsoft:windows_server_2012_R2:6.3.9600.20044:*:*:*:*:*:x64:*" ], "platforms": [ "x64-based Systems" ], "product": "Windows Server 2012 R2 (Server Core installation)", "vendor": "Microsoft", "versions": [ { "lessThan": "6.3.9600.20045", "status": "affected", "version": "6.3.0", "versionType": "custom" }, { "lessThan": "6.3.9600.20044", "status": "affected", "version": "6.3.0", "versionType": "custom" } ] } ], "datePublic": "2021-06-08T07:00:00.000Z", "descriptions": [ { "lang": "en-US", "value": "Windows Print Spooler Remote Code Execution Vulnerability" } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en-US", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "Elevation of Privilege", "lang": "en-US", "type": "Impact" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-29T14:55:40.040Z", "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8", "shortName": "microsoft" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://portal.msrc.microsoft.com/en-US/security-guidance/advisory/CVE-2021-1675" }, { "name": "VU#383432", "tags": [ "third-party-advisory", "x_refsource_CERT-VN" ], "url": "https://www.kb.cert.org/vuls/id/383432" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/163349/Microsoft-PrintNightmare-Proof-Of-Concept.html" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/163351/PrintNightmare-Windows-Spooler-Service-Remote-Code-Execution.html" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/167261/Print-Spooler-Remote-DLL-Injection.html" } ], "title": "Windows Print Spooler Remote Code Execution Vulnerability" } }, "cveMetadata": { "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8", "assignerShortName": "microsoft", "cveId": "CVE-2021-1675", "datePublished": "2021-06-08T22:46:11.000Z", "dateReserved": "2020-12-02T00:00:00.000Z", "dateUpdated": "2025-07-30T01:38:09.160Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22808 (GCVE-0-2021-22808)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.461Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:43", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22808", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-07" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22808", "datePublished": "2022-01-28T19:09:43", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.461Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-22815 (GCVE-0-2021-22815)
Vulnerability from cvelistv5
Published
2022-01-28 19:09
Modified
2024-08-03 18:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
References
URL | Tags | |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:51:07.471Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T19:09:49", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2021-22815", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03", "refsource": "MISC", "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-03" } ] } } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2021-22815", "datePublished": "2022-01-28T19:09:49", "dateReserved": "2021-01-06T00:00:00", "dateUpdated": "2024-08-03T18:51:07.471Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-28895 (GCVE-0-2020-28895)
Vulnerability from cvelistv5
Published
2021-02-03 15:16
Modified
2024-08-04 16:41
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption.
References
URL | Tags | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:41:00.095Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "credits": [ { "lang": "en", "value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e" } ], "datePublic": "2020-12-14T00:00:00", "descriptions": [ { "lang": "en", "value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-19T23:22:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "tags": [ "x_refsource_MISC" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ], "source": { "discovery": "EXTERNAL" }, "title": "integer overflow in calloc", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-28895", "STATE": "PUBLIC", "TITLE": "integer overflow in calloc" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "credit": [ { "lang": "eng", "value": "Reported by Omri Ben Bassat \u003cv-obenbassat@microsoft.com\u003e" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block\u0027s size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=defects\u0026on=view\u0026id=V7LIBC-1327" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2020-28895" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2022.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" } ] }, "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-28895", "datePublished": "2021-02-03T15:16:34", "dateReserved": "2020-11-17T00:00:00", "dateUpdated": "2024-08-04T16:41:00.095Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…