CVE-2021-22764
Vulnerability from cvelistv5
Published
2021-06-11 15:40
Modified
2024-11-24 14:41
Severity ?
Summary
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:07.316Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02%2Chttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.\u003c/p\u003e"
            }
          ],
          "value": "A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-24T14:41:33.312Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-159-02.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2021-22764",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "PowerLogic PM55xx, PowerLogic EGX100, and PowerLogic EGX300 (see security notification for version infromation)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02,http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03",
              "refsource": "MISC",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02,http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2021-22764",
    "datePublished": "2021-06-11T15:40:47",
    "dateReserved": "2021-01-06T00:00:00",
    "dateUpdated": "2024-11-24T14:41:33.312Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-22764\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-06-11T16:15:10.390\",\"lastModified\":\"2024-11-24T15:15:04.637\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.\"},{\"lang\":\"es\",\"value\":\"Un CWE-287: Se presenta una vulnerabilidad de autenticaci\u00f3n inapropiada en PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 y PowerLogic EGX300 (v\u00e9ase la notificaci\u00f3n de seguridad para obtener informaci\u00f3n sobre la versi\u00f3n) que podr\u00eda causar la p\u00e9rdida de conectividad con el dispositivo por medio del protocolo Modbus TCP cuando un atacante env\u00eda una petici\u00f3n HTTP especialmente dise\u00f1ada\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm5560_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.7.8\",\"matchCriteriaId\":\"0F8EC9ED-1E27-40B8-84A8-F66BC9FD0803\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm5560:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DDB1B76-3862-462E-B55D-875EBE508B92\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm5561_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.7.3\",\"matchCriteriaId\":\"EE3EFC50-39EA-4029-9713-9D191357DD29\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm5561:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00D6C9E0-7DB3-4742-86F0-3430E99D1B1D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm5562_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.5.4\",\"matchCriteriaId\":\"FDBB46A2-4EAD-41DA-AC02-5E985EB755A1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm5562:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"55D7896E-3EFA-4632-B0D2-273084D56936\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:powerlogic_pm5563_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.7.8\",\"matchCriteriaId\":\"4E870589-0ADF-4B76-89CF-2D36F5C61CF0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:powerlogic_pm5563:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C5D4C9C4-C258-453B-85E4-893978D6C499\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-159-02.pdf\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-02%2Chttp://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.