Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-10053 (GCVE-0-2020-10053)
Vulnerability from cvelistv5
- CWE-312 - Cleartext Storage of Sensitive Information
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | SIMATIC RTLS Locating Manager |
Version: All versions < V2.12 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:50:57.831Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC RTLS Locating Manager", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.12" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-312", "description": "CWE-312: Cleartext Storage of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-11-09T11:31:37", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10053", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC RTLS Locating Manager", "version": { "version_data": [ { "version_value": "All versions \u003c V2.12" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-312: Cleartext Storage of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-10053", "datePublished": "2021-11-09T11:31:37", "dateReserved": "2020-03-04T00:00:00", "dateUpdated": "2024-08-04T10:50:57.831Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-10053\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-11-09T12:15:08.150\",\"lastModified\":\"2024-11-21T04:54:42.733\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC RTLS Locating Manager (Todas las versiones anteriores a V2.12). La aplicaci\u00f3n afectada escribe datos confidenciales, como las credenciales de la base de datos en los archivos de configuraci\u00f3n. Un atacante local con acceso a los archivos de configuraci\u00f3n podr\u00eda usar esta informaci\u00f3n para lanzar otros ataques\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.12\",\"matchCriteriaId\":\"90B8EC72-CF5E-42F4-AB20-1F13B3BE322D\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
gsd-2020-10053
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2020-10053", "description": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.", "id": "GSD-2020-10053" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-10053" ], "details": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.", "id": "GSD-2020-10053", "modified": "2023-12-13T01:22:04.083890Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10053", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC RTLS Locating Manager", "version": { "version_data": [ { "version_value": "All versions \u003c V2.12" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-312: Cleartext Storage of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.12", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-10053" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-312" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6 } }, "lastModifiedDate": "2021-11-11T02:24Z", "publishedDate": "2021-11-09T12:15Z" } } }
ghsa-xcm6-w86x-xg6r
Vulnerability from github
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.
{ "affected": [], "aliases": [ "CVE-2020-10053" ], "database_specific": { "cwe_ids": [ "CWE-312" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-11-09T12:15:00Z", "severity": "MODERATE" }, "details": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.", "id": "GHSA-xcm6-w86x-xg6r", "modified": "2022-05-24T19:20:11Z", "published": "2022-05-24T19:20:11Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-10053" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" } ], "schema_version": "1.4.0", "severity": [] }
cnvd-2021-89428
Vulnerability from cnvd
目前厂商已发布升级补丁以修复漏洞,补丁获取链接: https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf
Name | Siemens SIMATIC RTLS Locating Manager <2.12 |
---|
{ "cves": { "cve": { "cveNumber": "CVE-2020-10053", "cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2020-10053" } }, "description": "SIMATIC RTLS Locating Manager\u7528\u4e8e\u914d\u7f6e\u3001\u64cd\u4f5c\u548c\u7ef4\u62a4SIMATIC RTLS\u88c5\u7f6e\uff0c\u8be5\u88c5\u7f6e\u662f\u4e00\u4e2a\u5b9e\u65f6\u65e0\u7ebf\u5b9a\u4f4d\u7cfb\u7edf\uff0c\u53ef\u63d0\u4f9b\u5b9a\u4f4d\u89e3\u51b3\u65b9\u6848\u3002\n\nSiemens SIMATIC RTLS Locating Manager\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5e94\u7528\u7a0b\u5e8f\u4f1a\u5728\u914d\u7f6e\u6587\u4ef6\u4e2d\u5199\u5165\u654f\u611f\u6570\u636e\uff0c\u4f8b\u5982\u6570\u636e\u5e93\u51ed\u636e\u3002\u53ef\u4ee5\u8bbf\u95ee\u914d\u7f6e\u6587\u4ef6\u7684\u672c\u5730\u653b\u51fb\u8005\u53ef\u4ee5\u4f7f\u7528\u6b64\u4fe1\u606f\u53d1\u8d77\u8fdb\u4e00\u6b65\u7684\u653b\u51fb\u3002", "formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u53d1\u5e03\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6f0f\u6d1e\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf", "isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e", "number": "CNVD-2021-89428", "openTime": "2021-11-20", "patchDescription": "SIMATIC RTLS Locating Manager\u7528\u4e8e\u914d\u7f6e\u3001\u64cd\u4f5c\u548c\u7ef4\u62a4SIMATIC RTLS\u88c5\u7f6e\uff0c\u8be5\u88c5\u7f6e\u662f\u4e00\u4e2a\u5b9e\u65f6\u65e0\u7ebf\u5b9a\u4f4d\u7cfb\u7edf\uff0c\u53ef\u63d0\u4f9b\u5b9a\u4f4d\u89e3\u51b3\u65b9\u6848\u3002\r\n\r\nSiemens SIMATIC RTLS Locating Manager\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5e94\u7528\u7a0b\u5e8f\u4f1a\u5728\u914d\u7f6e\u6587\u4ef6\u4e2d\u5199\u5165\u654f\u611f\u6570\u636e\uff0c\u4f8b\u5982\u6570\u636e\u5e93\u51ed\u636e\u3002\u53ef\u4ee5\u8bbf\u95ee\u914d\u7f6e\u6587\u4ef6\u7684\u672c\u5730\u653b\u51fb\u8005\u53ef\u4ee5\u4f7f\u7528\u6b64\u4fe1\u606f\u53d1\u8d77\u8fdb\u4e00\u6b65\u7684\u653b\u51fb\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002", "patchName": "Siemens SIMATIC RTLS Locating Manager\u654f\u611f\u4fe1\u606f\u660e\u6587\u5b58\u50a8\u6f0f\u6d1e\u7684\u8865\u4e01", "products": { "product": "Siemens SIMATIC RTLS Locating Manager \u003c2.12" }, "referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf", "serverity": "\u4f4e", "submitTime": "2021-11-12", "title": "Siemens SIMATIC RTLS Locating Manager\u654f\u611f\u4fe1\u606f\u660e\u6587\u5b58\u50a8\u6f0f\u6d1e" }
fkie_cve-2020-10053
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_rtls_locating_manager | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "90B8EC72-CF5E-42F4-AB20-1F13B3BE322D", "versionEndExcluding": "2.12", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC RTLS Locating Manager (Todas las versiones anteriores a V2.12). La aplicaci\u00f3n afectada escribe datos confidenciales, como las credenciales de la base de datos en los archivos de configuraci\u00f3n. Un atacante local con acceso a los archivos de configuraci\u00f3n podr\u00eda usar esta informaci\u00f3n para lanzar otros ataques" } ], "id": "CVE-2020-10053", "lastModified": "2024-11-21T04:54:42.733", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-11-09T12:15:08.150", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-312" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
ICSA-21-315-11
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "SIMATIC RTLS Locating Manager before V2.12 contains multiple vulnerabilities that could allow an attacker to read sensitive data or trigger a denial-of-service condition of the application service.\n\nSiemens has released an update for the SIMATIC RTLS Locating Manager and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-145157: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V2.12 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-145157.json" }, { "category": "self", "summary": "SSA-145157: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V2.12 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-145157.txt" }, { "category": "self", "summary": "SSA-145157: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V2.12 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-11 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-315-11.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-11 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-315-11" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SIMATIC RTLS Locating Manager", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-315-11", "initial_release_date": "2021-11-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.12", "product": { "name": "SIMATIC RTLS Locating Manager", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC RTLS Locating Manager" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-10052", "cwe": { "id": "CWE-532", "name": "Insertion of Sensitive Information into Log File" }, "notes": [ { "category": "summary", "text": "The affected application writes sensitive data, such as usernames and passwords in log files. A local attacker with access to the log files could use this information to launch further attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2020-10052 - SIMATIC RTLS Locating Manager", "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "summary": "CVE-2020-10052 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-10052.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.12 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "category": "mitigation", "details": "Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional local accounts on the server", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-10052" }, { "cve": "CVE-2020-10053", "cwe": { "id": "CWE-312", "name": "Cleartext Storage of Sensitive Information" }, "notes": [ { "category": "summary", "text": "The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2020-10053 - SIMATIC RTLS Locating Manager", "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "summary": "CVE-2020-10053 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-10053.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.12 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "category": "mitigation", "details": "Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional local accounts on the server", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-10053" }, { "cve": "CVE-2020-10054", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The affected application does not properly handle the import of large configuration files. A local attacker could import a specially crafted file which could lead to a denial-of-service condition of the application service.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2020-10054 - SIMATIC RTLS Locating Manager", "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "summary": "CVE-2020-10054 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-10054.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.12 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "category": "mitigation", "details": "Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional local accounts on the server", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-10054" } ] }
icsa-21-315-11
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "notes": [ { "category": "summary", "text": "SIMATIC RTLS Locating Manager before V2.12 contains multiple vulnerabilities that could allow an attacker to read sensitive data or trigger a denial-of-service condition of the application service.\n\nSiemens has released an update for the SIMATIC RTLS Locating Manager and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-145157: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V2.12 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-145157.json" }, { "category": "self", "summary": "SSA-145157: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V2.12 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-145157.txt" }, { "category": "self", "summary": "SSA-145157: Multiple Vulnerabilities in SIMATIC RTLS Locating Manager before V2.12 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-11 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-315-11.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-315-11 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-315-11" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SIMATIC RTLS Locating Manager", "tracking": { "current_release_date": "2025-05-06T06:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-315-11", "initial_release_date": "2021-11-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-11-09T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2025-05-06T06:00:00.000000Z", "legacy_version": "Revision", "number": "2", "summary": "Revision - Fixing typos" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2.12", "product": { "name": "SIMATIC RTLS Locating Manager", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "SIMATIC RTLS Locating Manager" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-10052", "cwe": { "id": "CWE-532", "name": "Insertion of Sensitive Information into Log File" }, "notes": [ { "category": "summary", "text": "The affected application writes sensitive data, such as usernames and passwords in log files. A local attacker with access to the log files could use this information to launch further attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2020-10052 - SIMATIC RTLS Locating Manager", "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "summary": "CVE-2020-10052 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-10052.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.12 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "category": "mitigation", "details": "Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional local accounts on the server", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-10052" }, { "cve": "CVE-2020-10053", "cwe": { "id": "CWE-312", "name": "Cleartext Storage of Sensitive Information" }, "notes": [ { "category": "summary", "text": "The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2020-10053 - SIMATIC RTLS Locating Manager", "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "summary": "CVE-2020-10053 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-10053.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.12 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "category": "mitigation", "details": "Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional local accounts on the server", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-10053" }, { "cve": "CVE-2020-10054", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "The affected application does not properly handle the import of large configuration files. A local attacker could import a specially crafted file which could lead to a denial-of-service condition of the application service.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2020-10054 - SIMATIC RTLS Locating Manager", "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "summary": "CVE-2020-10054 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-10054.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V2.12 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109803363/" }, { "category": "mitigation", "details": "Apply security hardening of the Windows Server, where the RTLS Locating Manager is installed on, in accordance with your corporate security policies or up-to-date hardening guidelines", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional local accounts on the server", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2020-10054" } ] }
var-202111-0487
Vulnerability from variot
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202111-0487", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic rtls locating manager", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.12" }, { "model": "simatic rtls locating manager", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "2.12" }, { "model": "simatic rtls locating manager", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "db": "NVD", "id": "CVE-2020-10053" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202111-774" } ], "trust": 0.6 }, "cve": "CVE-2020-10053", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2020-10053", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 1.8, "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "nvd@nist.gov", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2020-10053", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-10053", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2020-10053", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "CVE-2020-10053", "trust": 0.8, "value": "Medium" }, { "author": "CNNVD", "id": "CNNVD-202111-774", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "db": "CNNVD", "id": "CNNVD-202111-774" }, { "db": "NVD", "id": "CVE-2020-10053" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions \u003c V2.12). The affected application writes sensitive data, such as database credentials in configuration files. A local attacker with access to the configuration files could use this information to launch further attacks", "sources": [ { "db": "NVD", "id": "CVE-2020-10053" }, { "db": "JVNDB", "id": "JVNDB-2021-014839" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-10053", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-145157", "trust": 1.6 }, { "db": "ICS CERT", "id": "ICSA-21-315-11", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU95671889", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-014839", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021111912", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202111-774", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "db": "CNNVD", "id": "CNNVD-202111-774" }, { "db": "NVD", "id": "CVE-2020-10053" } ] }, "id": "VAR-202111-0487", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.35 }, "last_update_date": "2024-08-14T12:52:04.516000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-145157", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" }, { "title": "SIMATIC RTLS Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=169811" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "db": "CNNVD", "id": "CNNVD-202111-774" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-312", "trust": 1.0 }, { "problemtype": "Plaintext storage of important information (CWE-312) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "db": "NVD", "id": "CVE-2020-10053" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-10053" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu95671889/index.html" }, { "trust": 0.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-315-11" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-rtls-locating-manager-three-vulnerabilities-36833" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-315-11" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021111912" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "db": "CNNVD", "id": "CNNVD-202111-774" }, { "db": "NVD", "id": "CVE-2020-10053" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "db": "CNNVD", "id": "CNNVD-202111-774" }, { "db": "NVD", "id": "CVE-2020-10053" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "date": "2021-11-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202111-774" }, { "date": "2021-11-09T12:15:08.150000", "db": "NVD", "id": "CVE-2020-10053" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-10-28T07:59:00", "db": "JVNDB", "id": "JVNDB-2021-014839" }, { "date": "2021-11-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202111-774" }, { "date": "2021-11-11T02:24:34.970000", "db": "NVD", "id": "CVE-2020-10053" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202111-774" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "SIMATIC\u00a0RTLS\u00a0Locating\u00a0Manager\u00a0 Vulnerability in plaintext storage of important information in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-014839" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202111-774" } ], "trust": 0.6 } }
CERTFR-2021-AVI-854
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneVendor | Product | Description | ||
---|---|---|---|---|
Siemens | N/A | Capital VSTAR versions incluant les modules DNS | ||
Siemens | N/A | Nucleus Source Code toutes versions | ||
Siemens | N/A | Mendix Applications using Mendix 9 toutes versions antérieures à V9.6.2 | ||
Siemens | N/A | Nucleus NET toutes versions | ||
Siemens | N/A | SIMATIC WinCC V15 toutes versions | ||
Siemens | N/A | SIMATIC WinCC V17 toutes versions | ||
Siemens | N/A | SIMATIC WinCC OA V3.18 toutes versions | ||
Siemens | N/A | NX 1980 Series toutes versions antérieures à V1984 | ||
Siemens | N/A | APOGEE MEC (PPC) (BACnet) toutes versions | ||
Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions | ||
Siemens | N/A | SIMATIC WinCC V7.5 toutes versions antérieures à V7.5 SP2 Update 5 | ||
Siemens | N/A | SIMATIC WinCC OA V3.17 toutes versions | ||
Siemens | N/A | Climatix POL909 (AWM module) toutes versions antérieures à V11.34 | ||
Siemens | N/A | SCALANCE W1750D toutes versions antérieures à V8.7.1.3 | ||
Siemens | N/A | SIMATIC PCS 7 V9.0 toutes versions | ||
Siemens | N/A | Siveillance Video DLNA Server 2021 R1 | ||
Siemens | N/A | SIMATIC PCS 7 V9.1 toutes versions | ||
Siemens | N/A | Mendix Applications using Mendix 7 toutes versions antérieures à V7.23.26 | ||
Siemens | N/A | SIMATIC WinCC V7.4 toutes versions | ||
Siemens | N/A | APOGEE PXC Modular (BACnet) toutes versions | ||
Siemens | N/A | Nucleus Source Code versions incluant les modules DNS | ||
Siemens | N/A | SIMATIC WinCC V16 toutes versions | ||
Siemens | N/A | SIMATIC Information Server toutes versions >= V2019 SP1 | ||
Siemens | N/A | SICAM 230 toutes versions | ||
Siemens | N/A | Nucleus ReadyStart V4 toutes versions antérieures à V4.1.1 | ||
Siemens | N/A | Mendix Applications using Mendix 8 toutes versions antérieures à V8.18.13 | ||
Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions | ||
Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2017.02.4 | ||
Siemens | N/A | SIMATIC RTLS Locating Manager toutes versions antérieures à V2.12 | ||
Siemens | N/A | Siveillance Video DLNA Server 2020 R1, 2020 R2, 2020 R3 | ||
Siemens | N/A | Capital VSTAR toutes versions | ||
Siemens | N/A | Siveillance Video DLNA Server 2019 R1, 2019 R2, 2019 R3 | ||
Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2013.08 | ||
Siemens | N/A | APOGEE MEC (PPC) (P2 Ethernet) toutes versions | ||
Siemens | N/A | PSS(R)ODMS V12 toutes versions antérieures à V12.2.6.1 | ||
Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2012.12 | ||
Siemens | N/A | SENTRON powermanager V3 toutes versions | ||
Siemens | N/A | APOGEE PXC Compact (BACnet) toutes versions | ||
Siemens | N/A | TALON TC Compact (BACnet) toutes versions | ||
Siemens | N/A | NX 1980 Series toutes versions antérieures à V1988 | ||
Siemens | N/A | PSS(R)E V34 toutes versions antérieures à V34.9.1 | ||
Siemens | N/A | APOGEE MBC (PPC) (P2 Ethernet) toutes versions | ||
Siemens | N/A | NX 1953 Series toutes versions antérieures à V1973.3700 | ||
Siemens | N/A | APOGEE MBC (PPC) (BACnet) toutes versions | ||
Siemens | N/A | PSS(R)E V35 toutes versions antérieures à V35.3.2 | ||
Siemens | N/A | SIMATIC PCS 7 V8.2 toutes versions | ||
Siemens | N/A | TALON TC Modular (BACnet) toutes versions |
{ "$ref": "https://www.cert.ssi.gouv.fr/openapi.json", "affected_systems": [ { "description": "Capital VSTAR versions incluant les modules DNS", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus Source Code toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix 9 toutes versions ant\u00e9rieures \u00e0 V9.6.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus NET toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V15 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V17 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC OA V3.18 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "NX 1980 Series toutes versions ant\u00e9rieures \u00e0 V1984", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MEC (PPC) (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Compact (P2 Ethernet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V7.5 toutes versions ant\u00e9rieures \u00e0 V7.5 SP2 Update 5", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC OA V3.17 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Climatix POL909 (AWM module) toutes versions ant\u00e9rieures \u00e0 V11.34", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SCALANCE W1750D toutes versions ant\u00e9rieures \u00e0 V8.7.1.3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PCS 7 V9.0 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Video DLNA Server 2021 R1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PCS 7 V9.1 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix 7 toutes versions ant\u00e9rieures \u00e0 V7.23.26", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V7.4 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Modular (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus Source Code versions incluant les modules DNS", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC WinCC V16 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC Information Server toutes versions \u003e= V2019 SP1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SICAM 230 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus ReadyStart V4 toutes versions ant\u00e9rieures \u00e0 V4.1.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Mendix Applications using Mendix 8 toutes versions ant\u00e9rieures \u00e0 V8.18.13", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Modular (P2 Ethernet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2017.02.4", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC RTLS Locating Manager toutes versions ant\u00e9rieures \u00e0 V2.12", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Video DLNA Server 2020 R1, 2020 R2, 2020 R3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Capital VSTAR toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Siveillance Video DLNA Server 2019 R1, 2019 R2, 2019 R3", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2013.08", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MEC (PPC) (P2 Ethernet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "PSS(R)ODMS V12 toutes versions ant\u00e9rieures \u00e0 V12.2.6.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2012.12", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SENTRON powermanager V3 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE PXC Compact (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TALON TC Compact (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "NX 1980 Series toutes versions ant\u00e9rieures \u00e0 V1988", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "PSS(R)E V34 toutes versions ant\u00e9rieures \u00e0 V34.9.1", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MBC (PPC) (P2 Ethernet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "NX 1953 Series toutes versions ant\u00e9rieures \u00e0 V1973.3700", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "APOGEE MBC (PPC) (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "PSS(R)E V35 toutes versions ant\u00e9rieures \u00e0 V35.3.2", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "SIMATIC PCS 7 V8.2 toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } }, { "description": "TALON TC Modular (BACnet) toutes versions", "product": { "name": "N/A", "vendor": { "name": "Siemens", "scada": true } } } ], "affected_systems_content": null, "content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n", "cves": [ { "name": "CVE-2020-27009", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27009" }, { "name": "CVE-2021-31881", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31881" }, { "name": "CVE-2020-28388", "url": "https://www.cve.org/CVERecord?id=CVE-2020-28388" }, { "name": "CVE-2021-42026", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42026" }, { "name": "CVE-2021-37734", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37734" }, { "name": "CVE-2021-42025", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42025" }, { "name": "CVE-2021-37732", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37732" }, { "name": "CVE-2021-31888", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31888" }, { "name": "CVE-2020-27736", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27736" }, { "name": "CVE-2021-31885", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31885" }, { "name": "CVE-2021-31887", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31887" }, { "name": "CVE-2020-10053", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10053" }, { "name": "CVE-2021-37735", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37735" }, { "name": "CVE-2021-41533", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41533" }, { "name": "CVE-2021-25663", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25663" }, { "name": "CVE-2021-31884", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31884" }, { "name": "CVE-2021-42015", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42015" }, { "name": "CVE-2021-40366", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40366" }, { "name": "CVE-2020-15795", "url": "https://www.cve.org/CVERecord?id=CVE-2020-15795" }, { "name": "CVE-2021-31882", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31882" }, { "name": "CVE-2021-25664", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25664" }, { "name": "CVE-2021-41057", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41057" }, { "name": "CVE-2021-37207", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37207" }, { "name": "CVE-2021-40358", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40358" }, { "name": "CVE-2020-10052", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10052" }, { "name": "CVE-2021-37726", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37726" }, { "name": "CVE-2020-10054", "url": "https://www.cve.org/CVERecord?id=CVE-2020-10054" }, { "name": "CVE-2021-41535", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41535" }, { "name": "CVE-2021-37727", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37727" }, { "name": "CVE-2021-27393", "url": "https://www.cve.org/CVERecord?id=CVE-2021-27393" }, { "name": "CVE-2021-31346", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31346" }, { "name": "CVE-2021-40364", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40364" }, { "name": "CVE-2020-27738", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27738" }, { "name": "CVE-2021-31889", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31889" }, { "name": "CVE-2021-42021", "url": "https://www.cve.org/CVERecord?id=CVE-2021-42021" }, { "name": "CVE-2021-31883", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31883" }, { "name": "CVE-2021-41538", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41538" }, { "name": "CVE-2021-40359", "url": "https://www.cve.org/CVERecord?id=CVE-2021-40359" }, { "name": "CVE-2021-31886", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31886" }, { "name": "CVE-2021-41534", "url": "https://www.cve.org/CVERecord?id=CVE-2021-41534" }, { "name": "CVE-2021-31890", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31890" }, { "name": "CVE-2021-37730", "url": "https://www.cve.org/CVERecord?id=CVE-2021-37730" }, { "name": "CVE-2021-31345", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31345" }, { "name": "CVE-2020-27737", "url": "https://www.cve.org/CVERecord?id=CVE-2020-27737" }, { "name": "CVE-2021-31344", "url": "https://www.cve.org/CVERecord?id=CVE-2021-31344" }, { "name": "CVE-2021-25677", "url": "https://www.cve.org/CVERecord?id=CVE-2021-25677" } ], "initial_release_date": "2021-11-09T00:00:00", "last_revision_date": "2021-11-09T00:00:00", "links": [], "reference": "CERTFR-2021-AVI-854", "revisions": [ { "description": "Version initiale", "revision_date": "2021-11-09T00:00:00.000000" } ], "risks": [ { "description": "D\u00e9ni de service \u00e0 distance" }, { "description": "Ex\u00e9cution de code arbitraire \u00e0 distance" }, { "description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es" }, { "description": "Contournement de la politique de s\u00e9curit\u00e9" }, { "description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es" } ], "summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n", "title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens", "vendor_advisories": [ { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-248289 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-703715 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-703715.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-840188 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-362164 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-044112 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-328042 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-917476 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-114589 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-201384 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-201384.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-537983 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-537983.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-779699 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-580693 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-185699 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-740908 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-740908.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-145157 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-338732 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-755517 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf" }, { "published_at": null, "title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-705111 du 9 novembre 2021", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.