GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2019-6813 (GCVE-0-2019-6813)

Vulnerability from cvelistv5 – Published: 2019-09-17 19:56 – Updated: 2024-08-04 20:31
VLAI
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.
CWE
  • CWE-754 - Improper Check for Unusual or Exceptional Conditions
Impacted products
Vendor Product Version CPE status
CVE-2019-6813 BMXNOR0200H Ethernet / Serial RTU module Affected: all firmware versions
guessed Create a notification for this product.
CVE-2019-6813 Modicon M340 controller Affected: all firmware versions
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.281Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-02/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BMXNOR0200H Ethernet / Serial RTU module",
          "vendor": "CVE-2019-6813",
          "versions": [
            {
              "status": "affected",
              "version": "all firmware versions"
            }
          ]
        },
        {
          "product": "Modicon M340 controller",
          "vendor": "CVE-2019-6813",
          "versions": [
            {
              "status": "affected",
              "version": "all firmware versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-754",
              "description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-02T12:11:18.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-02/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6813",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BMXNOR0200H Ethernet / Serial RTU module",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all firmware versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Modicon M340 controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all firmware versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CVE-2019-6813"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"
            },
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-02/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-02/"
            },
            {
              "name": "https://security.cse.iitk.ac.in/responsible-disclosure",
              "refsource": "MISC",
              "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6813",
    "datePublished": "2019-09-17T19:56:55.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.281Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-6813",
      "date": "2026-09-16",
      "epss": "0.02084",
      "percentile": "0.80613"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"05CBA9AD-ECB7-453F-8551-DD176FDE8043\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"138681A2-0146-492B-8E10-06849FC27C6E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1D0B4021-E058-4B5B-823B-BB1C0A939E30\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"60D9A366-3394-4275-B884-AE6E7227156E\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.\"}, {\"lang\": \"es\", \"value\": \"Una CWE-754: Existe una vulnerabilidad de Comprobaci\\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en el m\\u00f3dulo BMXNOR0200H Ethernet/Serial RTU (todas las versiones de firmware) y el controlador Modicon M340 (todas las versiones de firmware), lo que podr\\u00eda causar una denegaci\\u00f3n de servicio cuando son recibidos por el dispositivo paquetes SNMP truncados sobre el puerto 161/UDP.\"}]",
      "id": "CVE-2019-6813",
      "lastModified": "2024-11-21T04:47:12.570",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:C\", \"baseScore\": 7.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2019-09-17T20:15:12.000",
      "references": "[{\"url\": \"https://security.cse.iitk.ac.in/responsible-disclosure\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-02/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://security.cse.iitk.ac.in/responsible-disclosure\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-02/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-754\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-754\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-6813\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2019-09-17T20:15:12.000\",\"lastModified\":\"2024-11-21T04:47:12.570\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could cause denial of service when truncated SNMP packets on port 161/UDP are received by the device.\"},{\"lang\":\"es\",\"value\":\"Una CWE-754: Existe una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en el m\u00f3dulo BMXNOR0200H Ethernet/Serial RTU (todas las versiones de firmware) y el controlador Modicon M340 (todas las versiones de firmware), lo que podr\u00eda causar una denegaci\u00f3n de servicio cuando son recibidos por el dispositivo paquetes SNMP truncados sobre el puerto 161/UDP.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":7.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-754\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"05CBA9AD-ECB7-453F-8551-DD176FDE8043\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"138681A2-0146-492B-8E10-06849FC27C6E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D0B4021-E058-4B5B-823B-BB1C0A939E30\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"60D9A366-3394-4275-B884-AE6E7227156E\"}]}]}],\"references\":[{\"url\":\"https://security.cse.iitk.ac.in/responsible-disclosure\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-02/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.cse.iitk.ac.in/responsible-disclosure\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-02/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…