CVE-2019-19276 (GCVE-0-2019-19276)
Vulnerability from cvelistv5
- CWE-787 - Out-of-bounds Write
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) |
Version: All versions < V16 Update 4 |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:09:39.475Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 4"
}
]
},
{
"product": "SIMATIC HMI KTP Mobile Panels",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-12T13:18:21",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19276",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-19276",
"datePublished": "2021-05-12T13:18:21",
"dateReserved": "2019-11-26T00:00:00",
"dateUpdated": "2024-08-05T02:09:39.475Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2019-19276\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-05-12T14:15:10.543\",\"lastModified\":\"2024-11-21T04:34:28.863\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 1st Generation (incluyendo variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels (Todas las versiones anteriores a V16 Update 4). Los paquetes especialmente dise\u00f1ados enviados al puerto 161/udp pueden hacer que el servicio SNMP de los dispositivos afectados se bloquee. Se requiere un reinicio manual del dispositivo para reanudar el funcionamiento del servicio\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1470479-8A5B-4A72-8B3C-A8311F787F81\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"85144667-DFAD-459A-84BE-E842CBC941ED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_3:*:*:*:*:*:*\",\"matchCriteriaId\":\"8A7EA7D4-1505-48CE-BCAC-15D65F199529\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1CEB200-E38F-4629-9279-5AF065396678\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"3CFD6C34-08A0-4653-A5DD-8CD4F43EF246\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FECA798-00DC-4182-AEA4-E06F9C697755\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_3:*:*:*:*:*:*\",\"matchCriteriaId\":\"77C80EA7-5B3F-42FE-9BF0-8B01674BA168\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3BCFE761-35C9-43EF-85BC-E8083B9F75CB\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
gsd-2019-19276
Vulnerability from gsd
{
"GSD": {
"alias": "CVE-2019-19276",
"description": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.",
"id": "GSD-2019-19276"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2019-19276"
],
"details": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.",
"id": "GSD-2019-19276",
"modified": "2023-12-13T01:23:54.230414Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19276",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19276"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4
}
},
"lastModifiedDate": "2021-06-02T18:18Z",
"publishedDate": "2021-05-12T14:15Z"
}
}
}
ghsa-v5g4-whqh-4265
Vulnerability from github
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.
{
"affected": [],
"aliases": [
"CVE-2019-19276"
],
"database_specific": {
"cwe_ids": [
"CWE-787"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-05-12T14:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.",
"id": "GHSA-v5g4-whqh-4265",
"modified": "2022-05-24T19:02:16Z",
"published": "2022-05-24T19:02:16Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-19276"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
cnvd-2021-41245
Vulnerability from cnvd
目前厂商已发布升级补丁以修复漏洞,补丁获取链接: https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf
| Name | ['SIEMENS SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) <v16 update 4', 'Siemens SIMATIC HMI KTP Mobile Panels <v16 update 4'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2019-19276",
"cveUrl": "https://nvd.nist.gov/vuln/detail/CVE-2019-19276"
}
},
"description": "Siemens SIMATIC\u662f\u897f\u95e8\u5b50\uff08Siemens\uff09\u7684\u4e00\u6b3e\u7ec4\u6001\u8f6f\u4ef6\u3002\n\n\u591a\u6b3eSiemens\u4ea7\u54c1\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u53d1\u9001\u5230\u7aef\u53e3161/UDP\u7684\u7279\u5236\u6570\u636e\u5305\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5bfc\u81f4\u53d7\u5f71\u54cd\u8bbe\u5907\u7684SNMP\u670d\u52a1\u5d29\u6e83\u3002",
"formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u53d1\u5e03\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6f0f\u6d1e\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-41245",
"openTime": "2021-06-13",
"patchDescription": "Siemens SIMATIC\u662f\u897f\u95e8\u5b50\uff08Siemens\uff09\u7684\u4e00\u6b3e\u7ec4\u6001\u8f6f\u4ef6\u3002\r\n\r\n\u591a\u6b3eSiemens\u4ea7\u54c1\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u53d1\u9001\u5230\u7aef\u53e3161/UDP\u7684\u7279\u5236\u6570\u636e\u5305\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5bfc\u81f4\u53d7\u5f71\u54cd\u8bbe\u5907\u7684SNMP\u670d\u52a1\u5d29\u6e83\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "\u591a\u6b3eSiemens\u4ea7\u54c1\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff08CNVD-2021-41245\uff09\u7684\u8865\u4e01",
"products": {
"product": [
"SIEMENS SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) \u003cv16 update 4",
"Siemens SIMATIC HMI KTP Mobile Panels \u003cv16 update 4"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf",
"serverity": "\u4e2d",
"submitTime": "2021-05-19",
"title": "\u591a\u6b3eSiemens\u4ea7\u54c1\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\uff08CNVD-2021-41245\uff09"
}
icsa-21-131-06
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Younes Dragoni",
"Alessandro Di Pinto"
],
"organization": "Nozomi Networks",
"summary": "coordinated disclosure"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "A denial-of-service vulnerability in WinCC Runtime could allow an unauthenticated attacker with network access to cause a denial-of-service condition in the SNMP service by sending crafted SNMP packets to port 161/udp.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-594364: Denial-of-Service Vulnerability in SNMP Implementation of WinCC Runtime - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-594364.json"
},
{
"category": "self",
"summary": "SSA-594364: Denial-of-Service Vulnerability in SNMP Implementation of WinCC Runtime - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-594364.txt"
},
{
"category": "self",
"summary": "SSA-594364: Denial-of-Service Vulnerability in SNMP Implementation of WinCC Runtime - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-131-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-131-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-131-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-131-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SNMP Implementation of WinCC Runtime",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-131-06",
"initial_release_date": "2021-05-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-05-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16_Update_4",
"product": {
"name": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16_Update_4",
"product": {
"name": "SIMATIC HMI KTP Mobile Panels",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI KTP Mobile Panels"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-19276",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2019-19276 - SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-19276 - SIMATIC HMI KTP Mobile Panels",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-19276 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-19276.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "mitigation",
"details": "Disable SNMP if this is supported by the product. Disabling SNMP fully mitigates the vulnerability",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict network access to port 161/udp of affected devices to trusted devices or IP addresses",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2019-19276"
}
]
}
ICSA-21-131-06
Vulnerability from csaf_cisa
Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Younes Dragoni",
"Alessandro Di Pinto"
],
"organization": "Nozomi Networks",
"summary": "coordinated disclosure"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"notes": [
{
"category": "summary",
"text": "A denial-of-service vulnerability in WinCC Runtime could allow an unauthenticated attacker with network access to cause a denial-of-service condition in the SNMP service by sending crafted SNMP packets to port 161/udp.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-594364: Denial-of-Service Vulnerability in SNMP Implementation of WinCC Runtime - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-594364.json"
},
{
"category": "self",
"summary": "SSA-594364: Denial-of-Service Vulnerability in SNMP Implementation of WinCC Runtime - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-594364.txt"
},
{
"category": "self",
"summary": "SSA-594364: Denial-of-Service Vulnerability in SNMP Implementation of WinCC Runtime - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-131-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-131-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-21-131-06 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-131-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SNMP Implementation of WinCC Runtime",
"tracking": {
"current_release_date": "2025-05-06T06:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-21-131-06",
"initial_release_date": "2021-05-11T00:00:00.000000Z",
"revision_history": [
{
"date": "2021-05-11T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-05-06T06:00:00.000000Z",
"legacy_version": "Revision",
"number": "2",
"summary": "Revision - Fixing typos"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16_Update_4",
"product": {
"name": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV16_Update_4",
"product": {
"name": "SIMATIC HMI KTP Mobile Panels",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI KTP Mobile Panels"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-19276",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"summary": "CVE-2019-19276 - SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-19276 - SIMATIC HMI KTP Mobile Panels",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"summary": "CVE-2019-19276 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-19276.json"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V16 Update 4 or later version",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109775861/"
},
{
"category": "mitigation",
"details": "Disable SNMP if this is supported by the product. Disabling SNMP fully mitigates the vulnerability",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Restrict network access to port 161/udp of affected devices to trusted devices or IP addresses",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"title": "CVE-2019-19276"
}
]
}
fkie_cve-2019-19276
Vulnerability from fkie_nvd
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf | Patch, Vendor Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:-:*:*:*:*:*:*",
"matchCriteriaId": "C1470479-8A5B-4A72-8B3C-A8311F787F81",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_2:*:*:*:*:*:*",
"matchCriteriaId": "85144667-DFAD-459A-84BE-E842CBC941ED",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_3:*:*:*:*:*:*",
"matchCriteriaId": "8A7EA7D4-1505-48CE-BCAC-15D65F199529",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:-:*:*:*:*:*:*",
"matchCriteriaId": "3CFD6C34-08A0-4653-A5DD-8CD4F43EF246",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_2:*:*:*:*:*:*",
"matchCriteriaId": "6FECA798-00DC-4182-AEA4-E06F9C697755",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_3:*:*:*:*:*:*",
"matchCriteriaId": "77C80EA7-5B3F-42FE-9BF0-8B01674BA168",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 1st Generation (incluyendo variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels (Todas las versiones anteriores a V16 Update 4). Los paquetes especialmente dise\u00f1ados enviados al puerto 161/udp pueden hacer que el servicio SNMP de los dispositivos afectados se bloquee. Se requiere un reinicio manual del dispositivo para reanudar el funcionamiento del servicio"
}
],
"id": "CVE-2019-19276",
"lastModified": "2024-11-21T04:34:28.863",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-05-12T14:15:10.543",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
var-202105-0068
Vulnerability from variot
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202105-0068",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "16"
},
{
"model": "simatic hmi ktp mobile panels",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "16"
},
{
"model": "simatic hmi ktp mobile panels",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic hmi comfort panels",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"db": "NVD",
"id": "CVE-2019-19276"
}
]
},
"cve": "CVE-2019-19276",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CVE-2019-19276",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2019-19276",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "Low",
"baseScore": 5.3,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-19276",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-19276",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2019-19276",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202104-975",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202105-541",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202105-541"
},
{
"db": "NVD",
"id": "CVE-2019-19276"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-19276"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "VULMON",
"id": "CVE-2019-19276"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-19276",
"trust": 3.3
},
{
"db": "SIEMENS",
"id": "SSA-594364",
"trust": 1.7
},
{
"db": "JVN",
"id": "JVNVU91051134",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007395",
"trust": 0.8
},
{
"db": "CS-HELP",
"id": "SB2021041363",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2021051309",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2021.1602",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-21-131-06",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202105-541",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2019-19276",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-19276"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202105-541"
},
{
"db": "NVD",
"id": "CVE-2019-19276"
}
]
},
"id": "VAR-202105-0068",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.57371795
},
"last_update_date": "2024-08-14T12:56:54.515000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-594364",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
},
{
"title": "Multiple Siemens Fix for device buffer error vulnerability",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=149969"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=3a6418c2c9d9d914ae85f34d330d364e"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-19276"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"db": "CNNVD",
"id": "CNNVD-202105-541"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [ Other ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"db": "NVD",
"id": "CVE-2019-19276"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-19276"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91051134/"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-06"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/siemens-simatic-wincc-denial-of-service-via-snmp-35359"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.1602"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2021051309"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/787.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-594364.txt"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2019-19276"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202105-541"
},
{
"db": "NVD",
"id": "CVE-2019-19276"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2019-19276"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202105-541"
},
{
"db": "NVD",
"id": "CVE-2019-19276"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-05-12T00:00:00",
"db": "VULMON",
"id": "CVE-2019-19276"
},
{
"date": "2022-02-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"date": "2021-04-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"date": "2021-05-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202105-541"
},
{
"date": "2021-05-12T14:15:10.543000",
"db": "NVD",
"id": "CVE-2019-19276"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-05-12T00:00:00",
"db": "VULMON",
"id": "CVE-2019-19276"
},
{
"date": "2022-02-09T09:11:00",
"db": "JVNDB",
"id": "JVNDB-2021-007395"
},
{
"date": "2021-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"date": "2021-06-03T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202105-541"
},
{
"date": "2021-06-02T18:18:33.440000",
"db": "NVD",
"id": "CVE-2019-19276"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202105-541"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC\u00a0HMI\u00a0Comfort\u00a0Panels\u00a01st\u00a0Generation\u00a0 and \u00a0SIMATIC\u00a0HMI\u00a0KTP\u00a0Mobile\u00a0Panels\u00a0 Out-of-bounds Vulnerability in Microsoft",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-007395"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
}
],
"trust": 0.6
}
}
CERTFR-2021-AVI-357
Vulnerability from certfr_avis
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer un déni de service à distance, une atteinte à la confidentialité des données et une élévation de privilèges.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | TECNOMATIX Plan Simulation versions antérieures à 16.0.5 | ||
| Siemens | N/A | SIMATIC NET CP 1545-1, CP 343-1 toutes versions | ||
| Siemens | N/A | SIMATIC NET CP 1243-1, CP 1243-7, CP 1243-8 versions 3.1.39 et ultérieures | ||
| Siemens | N/A | SINAMICS SL150, SM150, SM150i toutes versions | ||
| Siemens | N/A | SIMATIC IPC127E, IPC427E, IPC477E, IPC527G, IPC547G toutes versions | ||
| Siemens | N/A | SINUMERIK ONE 840D et PPU 1740 toutes versions | ||
| Siemens | N/A | MENDIX Database Replication versions antérieures à 7.0.1 | ||
| Siemens | N/A | SINAMICS GH150, GL150 (X30), GM150 (X30), SH150, SM120 avec les versions de HMI Panel antérieures à v16 update 4 | ||
| Siemens | N/A | RUGGEDCOM RM1224 versions antérieures à 6.4 | ||
| Siemens | N/A | SIMATIC WinCC runtime advanced versions antérieures à 16 update 4 | ||
| Siemens | N/A | MENDIX module Excel Importer versions antérieures à 9.0.3 | ||
| Siemens | N/A | SCALANCE XM-400, XR-500, M-800, S615 versions antérieures à 6.4 | ||
| Siemens | N/A | SCALANCE W1750D versions v8.3.0.1, v8.6.0 et v8.7.0 | ||
| Siemens | N/A | SIMATIC MV500 toutes versions | ||
| Siemens | N/A | SIMATIC IPC627E, IPC647E, IPC677E, IPC847E versions antérieures à 25.02.08 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 toutes versions | ||
| Siemens | N/A | SIMATIC HMI versions antérieures à 16 update 4 | ||
| Siemens | N/A | SINEMA Remote Connect Server versions antérieures à 3.0 SP1 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU 1515SP PC2 toutes versions | ||
| Siemens | N/A | SIMATIC Field PG M6 toutes versions | ||
| Siemens | N/A | SIMATIC ITP1000 versions antérieures à 23.01.08 | ||
| Siemens | N/A | TIM 1531 toutes versions | ||
| Siemens | N/A | SIMATIC NET CP 1542, CP 1543-1 versions 2.0 et ultérieures | ||
| Siemens | N/A | SINUMERIK 828D HW PPU.4, MC MCU 170 toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU 1518-4 ou 1518F-4 toutes versions | ||
| Siemens | N/A | SIMATIC Field PG M5 versions antérieures à 22.01.08 |
| Title | Publication Time | Tags | |
|---|---|---|---|
|
|
|||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "TECNOMATIX Plan Simulation versions ant\u00e9rieures \u00e0 16.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 1545-1, CP 343-1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 1243-1, CP 1243-7, CP 1243-8 versions 3.1.39 et ult\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS SL150, SM150, SM150i toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC127E, IPC427E, IPC477E, IPC527G, IPC547G toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK ONE 840D et PPU 1740 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "MENDIX Database Replication versions ant\u00e9rieures \u00e0 7.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS GH150, GL150 (X30), GM150 (X30), SH150, SM120 avec les versions de HMI Panel ant\u00e9rieures \u00e0 v16 update 4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224 versions ant\u00e9rieures \u00e0 6.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC runtime advanced versions ant\u00e9rieures \u00e0 16 update 4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "MENDIX module Excel Importer versions ant\u00e9rieures \u00e0 9.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM-400, XR-500, M-800, S615 versions ant\u00e9rieures \u00e0 6.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D versions v8.3.0.1, v8.6.0 et v8.7.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV500 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC IPC627E, IPC647E, IPC677E, IPC847E versions ant\u00e9rieures \u00e0 25.02.08",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI versions ant\u00e9rieures \u00e0 16 update 4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Remote Connect Server versions ant\u00e9rieures \u00e0 3.0 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Field PG M6 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITP1000 versions ant\u00e9rieures \u00e0 23.01.08",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 1531 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 1542, CP 1543-1 versions 2.0 et ult\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK 828D HW PPU.4, MC MCU 170 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU 1518-4 ou 1518F-4 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Field PG M5 versions ant\u00e9rieures \u00e0 22.01.08",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-25146",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25146"
},
{
"name": "CVE-2020-24636",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24636"
},
{
"name": "CVE-2020-15798",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-15798"
},
{
"name": "CVE-2021-25158",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25158"
},
{
"name": "CVE-2019-8262",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8262"
},
{
"name": "CVE-2019-8277",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8277"
},
{
"name": "CVE-2021-25157",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25157"
},
{
"name": "CVE-2021-25144",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25144"
},
{
"name": "CVE-2021-27385",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27385"
},
{
"name": "CVE-2021-25661",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25661"
},
{
"name": "CVE-2019-8265",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8265"
},
{
"name": "CVE-2021-25662",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25662"
},
{
"name": "CVE-2021-25161",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25161"
},
{
"name": "CVE-2020-8745",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8745"
},
{
"name": "CVE-2019-8260",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8260"
},
{
"name": "CVE-2021-27386",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27386"
},
{
"name": "CVE-2019-8263",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8263"
},
{
"name": "CVE-2021-25660",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25660"
},
{
"name": "CVE-2020-28393",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28393"
},
{
"name": "CVE-2021-25150",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25150"
},
{
"name": "CVE-2019-8261",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8261"
},
{
"name": "CVE-2019-8259",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8259"
},
{
"name": "CVE-2019-5317",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-5317"
},
{
"name": "CVE-2021-25145",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25145"
},
{
"name": "CVE-2021-31341",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31341"
},
{
"name": "CVE-2021-27396",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27396"
},
{
"name": "CVE-2020-8698",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8698"
},
{
"name": "CVE-2020-25705",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25705"
},
{
"name": "CVE-2021-25148",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25148"
},
{
"name": "CVE-2019-8280",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8280"
},
{
"name": "CVE-2021-27384",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27384"
},
{
"name": "CVE-2020-0591",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-0591"
},
{
"name": "CVE-2020-0590",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-0590"
},
{
"name": "CVE-2019-8275",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8275"
},
{
"name": "CVE-2021-25149",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25149"
},
{
"name": "CVE-2020-25242",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25242"
},
{
"name": "CVE-2021-27397",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27397"
},
{
"name": "CVE-2019-5319",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-5319"
},
{
"name": "CVE-2021-25156",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25156"
},
{
"name": "CVE-2019-8264",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8264"
},
{
"name": "CVE-2019-19276",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19276"
},
{
"name": "CVE-2020-8694",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8694"
},
{
"name": "CVE-2021-25160",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25160"
},
{
"name": "CVE-2021-25159",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25159"
},
{
"name": "CVE-2021-25155",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25155"
},
{
"name": "CVE-2021-31339",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31339"
},
{
"name": "CVE-2021-27383",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27383"
},
{
"name": "CVE-2020-8744",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8744"
},
{
"name": "CVE-2021-25143",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25143"
},
{
"name": "CVE-2021-25162",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25162"
},
{
"name": "CVE-2021-27398",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27398"
},
{
"name": "CVE-2020-24635",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-24635"
}
],
"initial_release_date": "2021-05-11T00:00:00",
"last_revision_date": "2021-05-11T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-854248.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-324955.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-983548.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-723417.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-919955.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501073.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-676775.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf"
}
],
"reference": "CERTFR-2021-AVI-357",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-05-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nun d\u00e9ni de service \u00e0 distance, une atteinte \u00e0 la confidentialit\u00e9 des\ndonn\u00e9es et une \u00e9l\u00e9vation de privil\u00e8ges.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens du 11 mai 2021",
"url": null
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.