GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2018-10510 (GCVE-0-2018-10510)

Vulnerability from cvelistv5 – Published: 2018-08-15 19:00 – Updated: 2024-08-05 07:39
VLAI
Summary
A Directory Traversal Remote Code Execution vulnerability in Trend Micro Control Manager (versions 6.0 and 7.0) could allow an attacker to execute arbitrary code on vulnerable installations.
CWE
  • Directory Traversal
References
Impacted products
Vendor Product Version CPE status
Trend Micro Trend Micro Control Manager Affected: 6.0 and 7.0
guessed Create a notification for this product.
Date Public
2018-08-15 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:39:07.994Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://success.trendmicro.com/solution/1120112"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Trend Micro Control Manager",
          "vendor": "Trend Micro",
          "versions": [
            {
              "status": "affected",
              "version": "6.0 and 7.0"
            }
          ]
        }
      ],
      "datePublic": "2018-08-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Directory Traversal Remote Code Execution vulnerability in Trend Micro Control Manager (versions 6.0 and 7.0) could allow an attacker to execute arbitrary code on vulnerable installations."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Directory Traversal",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-15T18:57:01.000Z",
        "orgId": "7f7bd7df-cffe-4fdb-ab6d-859363b89272",
        "shortName": "trendmicro"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://success.trendmicro.com/solution/1120112"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@trendmicro.com",
          "ID": "CVE-2018-10510",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Trend Micro Control Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.0 and 7.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Trend Micro"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Directory Traversal Remote Code Execution vulnerability in Trend Micro Control Manager (versions 6.0 and 7.0) could allow an attacker to execute arbitrary code on vulnerable installations."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Directory Traversal"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://success.trendmicro.com/solution/1120112",
              "refsource": "CONFIRM",
              "url": "https://success.trendmicro.com/solution/1120112"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7f7bd7df-cffe-4fdb-ab6d-859363b89272",
    "assignerShortName": "trendmicro",
    "cveId": "CVE-2018-10510",
    "datePublished": "2018-08-15T19:00:00.000Z",
    "dateReserved": "2018-04-27T00:00:00.000Z",
    "dateUpdated": "2024-08-05T07:39:07.994Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-10510",
      "date": "2026-09-16",
      "epss": "0.06464",
      "percentile": "0.93384"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:trendmicro:control_manager:6.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2F7E3779-69E4-46AB-94E3-4A81E35A5194\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:trendmicro:control_manager:7.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6F58BCC4-75BE-4B7D-8E29-27CAE3184858\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A2572D17-1DE6-457B-99CC-64AFD54487EA\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A Directory Traversal Remote Code Execution vulnerability in Trend Micro Control Manager (versions 6.0 and 7.0) could allow an attacker to execute arbitrary code on vulnerable installations.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de salto de directorio por ejecuci\\u00f3n remota de c\\u00f3digo en Trend Micro Control Manager (versiones 6.0 y 7.0) podr\\u00eda permitir que un atacante ejecute c\\u00f3digo arbitrario en instalaciones vulnerables.\"}]",
      "id": "CVE-2018-10510",
      "lastModified": "2024-11-21T03:41:28.010",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-08-15T19:29:00.230",
      "references": "[{\"url\": \"https://success.trendmicro.com/solution/1120112\", \"source\": \"security@trendmicro.com\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://success.trendmicro.com/solution/1120112\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "security@trendmicro.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-22\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-10510\",\"sourceIdentifier\":\"security@trendmicro.com\",\"published\":\"2018-08-15T19:29:00.230\",\"lastModified\":\"2024-11-21T03:41:28.010\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Directory Traversal Remote Code Execution vulnerability in Trend Micro Control Manager (versions 6.0 and 7.0) could allow an attacker to execute arbitrary code on vulnerable installations.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de salto de directorio por ejecuci\u00f3n remota de c\u00f3digo en Trend Micro Control Manager (versiones 6.0 y 7.0) podr\u00eda permitir que un atacante ejecute c\u00f3digo arbitrario en instalaciones vulnerables.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trendmicro:control_manager:6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F7E3779-69E4-46AB-94E3-4A81E35A5194\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:trendmicro:control_manager:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F58BCC4-75BE-4B7D-8E29-27CAE3184858\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A2572D17-1DE6-457B-99CC-64AFD54487EA\"}]}]}],\"references\":[{\"url\":\"https://success.trendmicro.com/solution/1120112\",\"source\":\"security@trendmicro.com\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://success.trendmicro.com/solution/1120112\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…