GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2017-7968 (GCVE-0-2017-7968)

Vulnerability from cvelistv5 – Published: 2017-05-19 15:00 – Updated: 2024-08-05 16:19
VLAI
Summary
An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges.
CWE
References
Impacted products
Vendor Product Version CPE status
n/a Schneider Electric Wonderware InduSoft Web Studio Affected: Schneider Electric Wonderware InduSoft Web Studio
Date Public
2017-05-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.522Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-138-02"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-02"
          },
          {
            "name": "98544",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98544"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Wonderware InduSoft Web Studio",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Wonderware InduSoft Web Studio"
            }
          ]
        }
      ],
      "datePublic": "2017-05-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system\u0027s path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-05-24T09:57:01.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-138-02"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-02"
        },
        {
          "name": "98544",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98544"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2017-7968",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Wonderware InduSoft Web Studio",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Wonderware InduSoft Web Studio"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system\u0027s path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-276"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-138-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-138-02"
            },
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-02",
              "refsource": "MISC",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-02"
            },
            {
              "name": "98544",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/98544"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2017-7968",
    "datePublished": "2017-05-19T15:00:00.000Z",
    "dateReserved": "2017-04-19T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.522Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-7968",
      "date": "2026-09-19",
      "epss": "0.00432",
      "percentile": "0.3701"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:schneider-electric:wonderware_indusoft_web_studio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "93923A2F-FFAB-4418-8F1E-603DF4C1DEB1",
                  "versionEndIncluding": "8.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system\u0027s path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges."
        },
        {
          "lang": "es",
          "value": "Un problema de permisos predeterminado incorrecto se descubri\u00f3 en Schneider Electric Wonderware InduSoft Web Studio v8.0 revisi\u00f3n 3 y versiones anteriores. Despu\u00e9s de la instalaci\u00f3n, Wonderware InduSoft Web Studio crea un nuevo directorio y dos archivos, que se colocan en la ruta del sistema y pueden ser manipulados por no administradores. Esto podr\u00eda permitir a un usuario autenticado escalar sus privilegios."
        }
      ],
      "id": "CVE-2017-7968",
      "lastModified": "2024-11-21T03:33:04.003",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 7.2,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2017-05-19T15:29:00.287",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-02"
        },
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/98544"
        },
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-138-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/98544"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-138-02"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-276"
            }
          ],
          "source": "cybersecurity@se.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-276"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:schneider-electric:wonderware_indusoft_web_studio:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "93923A2F-FFAB-4418-8F1E-603DF4C1DEB1",
                    "versionEndIncluding": "8.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system\u0027s path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges."
          },
          {
            "lang": "es",
            "value": "Un problema de permisos predeterminado incorrecto se descubri\u00f3 en Schneider Electric Wonderware InduSoft Web Studio v8.0 revisi\u00f3n 3 y versiones anteriores. Despu\u00e9s de la instalaci\u00f3n, Wonderware InduSoft Web Studio crea un nuevo directorio y dos archivos, que se colocan en la ruta del sistema y pueden ser manipulados por no administradores. Esto podr\u00eda permitir a un usuario autenticado escalar sus privilegios."
          }
        ],
        "id": "CVE-2017-7968",
        "lastModified": "2026-05-13T00:24:29.033",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2017-05-19T15:29:00.287",
        "references": [
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-02"
          },
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/98544"
          },
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-138-02"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-090-02"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/98544"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-138-02"
          }
        ],
        "sourceIdentifier": "cybersecurity@se.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-276"
              }
            ],
            "source": "cybersecurity@se.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-276"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…