CVE-2017-6019
Vulnerability from cvelistv5
Published
2017-04-07 22:00
Modified
2024-08-05 15:18
Severity ?
EPSS score ?
Summary
An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01 | Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/96543 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02 | Mitigation, Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.exploit-db.com/exploits/41537/ | ||
af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/96543 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02 | Mitigation, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.exploit-db.com/exploits/41537/ |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Schneider Electric Conext ComBox |
Version: Schneider Electric Conext ComBox |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T15:18:49.485Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01" }, { "name": "96543", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/96543" }, { "name": "41537", "tags": [ "exploit", "x_refsource_EXPLOIT-DB", "x_transferred" ], "url": "https://www.exploit-db.com/exploits/41537/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Schneider Electric Conext ComBox", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Schneider Electric Conext ComBox" } ] } ], "datePublic": "2017-04-07T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-15T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01" }, { "name": "96543", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/96543" }, { "name": "41537", "tags": [ "exploit", "x_refsource_EXPLOIT-DB" ], "url": "https://www.exploit-db.com/exploits/41537/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2017-6019", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Schneider Electric Conext ComBox", "version": { "version_data": [ { "version_value": "Schneider Electric Conext ComBox" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02" }, { "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01", "refsource": "CONFIRM", "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01" }, { "name": "96543", "refsource": "BID", "url": "http://www.securityfocus.com/bid/96543" }, { "name": "41537", "refsource": "EXPLOIT-DB", "url": "https://www.exploit-db.com/exploits/41537/" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2017-6019", "datePublished": "2017-04-07T22:00:00", "dateReserved": "2017-02-16T00:00:00", "dateUpdated": "2024-08-05T15:18:49.485Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2017-6019\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-04-07T22:59:01.810\",\"lastModified\":\"2024-11-21T03:28:54.930\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto un problema en Schneider Electric Conext ComBox, modelo 865-1058, todas las versiones de firmware anteriores a V3.03 BN 830. Una serie de solicitudes r\u00e1pidas al dispositivo puede hacer que reinicie.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"baseScore\":7.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:conext_combox_865-1058_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.03\",\"matchCriteriaId\":\"BDAB5C65-3978-47CC-80DE-1368764F90B6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:conext_combox_865-1058:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"209ADC1B-DFA8-422E-8F98-EB7397CB853A\"}]}]}],\"references\":[{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/96543\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.exploit-db.com/exploits/41537/\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/96543\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.exploit-db.com/exploits/41537/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.