CVE-2013-6920
Vulnerability from cvelistv5
Published
2013-12-07 00:00
Modified
2024-08-06 17:53
Severity ?
Summary
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T17:53:45.861Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-12-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-10T14:06:15",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-6920",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01"
            },
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-6920",
    "datePublished": "2013-12-07T00:00:00",
    "dateReserved": "2013-12-02T00:00:00",
    "dateUpdated": "2024-08-06T17:53:45.861Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2013-6920\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2013-12-07T00:55:04.147\",\"lastModified\":\"2024-11-21T01:59:58.257\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.\"},{\"lang\":\"es\",\"value\":\"Los controladores Siemens SINAMICS S/G con firmware anterior a 4.6.11 no requiere autenticaci\u00f3n para sesiones FTP y TELNET, lo que permite a atacantes remotos evadir restricciones de acceso intencionadas a trav\u00e9s de trafico TCP al puerto (1) 21 o (2) 23.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinamics_s\\\\/g_family_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.6\",\"matchCriteriaId\":\"F15BC1E1-45E3-44F0-BD41-E7A73FB33662\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g110:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5ADF0BB-01FA-4FE4-BF4D-D33A6C5DAAFD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g110d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5CE4257F-7262-4CC0-A874-374106B4B2C8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61A60DCE-384B-43A4-A669-973FB8ECA932\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g120c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"909DED2E-4CA6-4A07-B924-797260FDE2E4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g120d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"75ED7DEA-67F8-4971-A076-79AF82026FD0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g120p:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21FAA04F-FBE9-4EFA-BE79-1EAFF47A20D3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"373DBE44-AC28-4D04-93BB-35CD8C60E899\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2296CA65-0E89-4BCB-8003-E7212BF1F585\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_g180:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC515520-BB04-4849-ACE8-87ED5D591454\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6218802E-D3B1-4197-A6B5-7343A50F7D88\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5A824BD-935F-4E53-8313-C5544B0489C7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_s120cm:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C0ECF745-CE82-42C6-9EA0-12FBD89F6220\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D48682C-A39D-4A09-B904-50FA64A9D2A5\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01\",\"source\":\"cve@mitre.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-338-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-742938.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-742938.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.