GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2011-4508 (GCVE-0-2011-4508)

Vulnerability from cvelistv5 – Published: 2012-02-03 20:00 – Updated: 2024-09-16 20:47
VLAI
Summary
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
Severity
No CVSS data available.
CWE
  • n/a
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T00:09:18.474Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-02-03T20:00:00.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2011-4508",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2011-4508",
    "datePublished": "2012-02-03T20:00:00.000Z",
    "dateReserved": "2011-11-22T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:47:55.183Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2011-4508",
      "date": "2026-09-20",
      "epss": "0.0299",
      "percentile": "0.86719"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7D596C29-36F8-44F2-897D-FD107769E5A9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2D84E29A-4BC2-4229-83C3-D9F7A641D19C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9B3ADDE1-1F91-43E7-A3C3-3069916F4B23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1432EC7A-47B2-41D1-B90B-72DBB79AC266",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "1A4B1323-9AF3-424F-925A-A62F35E575E0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:sp2:*:*:*:*:*:*",
                  "matchCriteriaId": "E454C72B-7804-402B-9C6A-687BF2C45D39",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:wincc:*:sp2:*:*:*:*:*:*",
                  "matchCriteriaId": "9FE44373-06BD-4AA0-8778-06F2A150510C",
                  "versionEndIncluding": "v11",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*",
                  "matchCriteriaId": "18A9883B-80E1-4B2E-88DA-D2326AE3DC08",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:wincc:v11:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "F53FDA20-FE97-4BA3-9165-F0BD7A25FA5F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DC593746-B329-43EA-8CA1-AA56AC5A3B10",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*",
                  "matchCriteriaId": "442AC914-BDD5-4D0C-9E04-88F60EE2B730",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D9749966-1666-4F7D-90D0-17AFBB88AE83",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9471D239-08B1-4076-82F7-2B73F4E343CE",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1AE3AE80-C7A2-4581-993A-536936F6D315",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie."
        },
        {
          "lang": "es",
          "value": "El servidor web HMI de Siemens WinCC flexible v2004, v2005, v2007 y v2008 antes de SP3, WinCC V11 (tambi\u00e9n conocido como TIA Portal) antes de SP2 Update 1, TP, OP, MP, Comfort Panels, y de los paneles de Mobile Panels SIMATIC HMI, WinCC V11 Advanced Runtime, y WinCC flexible Runtime genera tokens de autenticaci\u00f3n para cookies, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes remotos a la hora de evitar la autenticaci\u00f3n usando una cookie manipulada."
        }
      ],
      "id": "CVE-2011-4508",
      "lastModified": "2024-11-21T01:32:26.773",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "HIGH",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "COMPLETE",
              "baseScore": 9.3,
              "confidentialityImpact": "COMPLETE",
              "integrityImpact": "COMPLETE",
              "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 10.0,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ]
      },
      "published": "2012-02-03T20:55:01.250",
      "references": [
        {
          "source": "cret@cert.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
        },
        {
          "source": "cret@cert.org",
          "tags": [
            "US Government Resource"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "US Government Resource"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
        }
      ],
      "sourceIdentifier": "cret@cert.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-287"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7D596C29-36F8-44F2-897D-FD107769E5A9",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2D84E29A-4BC2-4229-83C3-D9F7A641D19C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9B3ADDE1-1F91-43E7-A3C3-3069916F4B23",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1432EC7A-47B2-41D1-B90B-72DBB79AC266",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:sp1:*:*:*:*:*:*",
                    "matchCriteriaId": "1A4B1323-9AF3-424F-925A-A62F35E575E0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:sp2:*:*:*:*:*:*",
                    "matchCriteriaId": "E454C72B-7804-402B-9C6A-687BF2C45D39",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc:*:sp2:*:*:*:*:*:*",
                    "matchCriteriaId": "9FE44373-06BD-4AA0-8778-06F2A150510C",
                    "versionEndIncluding": "v11",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*",
                    "matchCriteriaId": "18A9883B-80E1-4B2E-88DA-D2326AE3DC08",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc:v11:sp1:*:*:*:*:*:*",
                    "matchCriteriaId": "F53FDA20-FE97-4BA3-9165-F0BD7A25FA5F",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DC593746-B329-43EA-8CA1-AA56AC5A3B10",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*",
                    "matchCriteriaId": "442AC914-BDD5-4D0C-9E04-88F60EE2B730",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D9749966-1666-4F7D-90D0-17AFBB88AE83",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9471D239-08B1-4076-82F7-2B73F4E343CE",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1AE3AE80-C7A2-4581-993A-536936F6D315",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie."
          },
          {
            "lang": "es",
            "value": "El servidor web HMI de Siemens WinCC flexible v2004, v2005, v2007 y v2008 antes de SP3, WinCC V11 (tambi\u00e9n conocido como TIA Portal) antes de SP2 Update 1, TP, OP, MP, Comfort Panels, y de los paneles de Mobile Panels SIMATIC HMI, WinCC V11 Advanced Runtime, y WinCC flexible Runtime genera tokens de autenticaci\u00f3n para cookies, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes remotos a la hora de evitar la autenticaci\u00f3n usando una cookie manipulada."
          }
        ],
        "id": "CVE-2011-4508",
        "lastModified": "2026-04-29T01:13:23.040",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.3,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ]
        },
        "published": "2012-02-03T20:55:01.250",
        "references": [
          {
            "source": "cret@cert.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
          },
          {
            "source": "cret@cert.org",
            "tags": [
              "US Government Resource"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "US Government Resource"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
          }
        ],
        "sourceIdentifier": "cret@cert.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…