    Vulnerability from variot - Updated: 2023-12-18 13:20

    Stack-based buffer overflow in WTclient.dll in SCADA Engine BACnet OPC Client before 1.0.25 allows user-assisted remote attackers to execute arbitrary code via a crafted .csv file, related to a status log message. This vulnerability WTclient.dll Due to the library. SCADA is the data acquisition and monitoring control system. BACnet OPC Client is prone to a buffer-overflow vulnerability because it fails to perform adequate boundary checks on user-supplied data. Failed exploit attempts will likely result in denial-of-service conditions. ----------------------------------------------------------------------

    Windows Applications Insecure Library Loading

    The Official, Verified Secunia List: http://secunia.com/advisories/windows_insecure_library_loading/

    The list is continuously updated as we confirm the vulnerability reports so check back regularly too see if any of your apps are affected.


    TITLE: SCADA Engine BACnet OPC Client Buffer Overflow Vulnerability

    SECUNIA ADVISORY ID: SA41466

    VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/41466/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=41466

    RELEASE DATE: 2010-09-18

    DISCUSS ADVISORY: http://secunia.com/advisories/41466/#comments

    AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)

    http://secunia.com/advisories/41466/

    ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS

    https://ca.secunia.com/?page=viewadvisory&vuln_id=41466

    ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING

    http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/

    DESCRIPTION: A vulnerability has been discovered in SCADA Engine BACnet OPC Client, which can be exploited by malicious people to compromise a user's system. tricking a user into opening a specially crafted *.csv file.

    The vulnerability is confirmed in version 1.0.24. Other versions may also be affected.

    SOLUTION: Do not open untrusted files.

    PROVIDED AND/OR DISCOVERED BY: Jeremy Brown

    OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/

    DEEP LINKS: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/

    EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/

    EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/

    EXPLOIT: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/


    About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.

    Subscribe: http://secunia.com/advisories/secunia_security_advisories/

    Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/

    Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.


    Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org


    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201102-0181",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "engine bacnet opc client",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "scada",
            "version": "1.0.24"
          },
          {
            "model": "bacnet opc client",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "scadaengine",
            "version": "1.0.24"
          },
          {
            "model": null,
            "scope": null,
            "trust": 0.8,
            "vendor": "scada engine",
            "version": null
          },
          {
            "model": "bacnet opc client",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "scada engine",
            "version": "version  1.0.24"
          },
          {
            "model": "bacnet opc client",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "scadaengine",
            "version": "1.0.24"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "db": "NVD",
            "id": "CVE-2010-4740"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:scadaengine:bacnet_opc_client:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.0.24",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2010-4740"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Jeremy Brown",
        "sources": [
          {
            "db": "BID",
            "id": "43289"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ],
        "trust": 0.9
      },
      "cve": "CVE-2010-4740",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 9.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 8.6,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": true,
                "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 9.3,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2010-4740",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": null,
                "accessVector": null,
                "authentication": null,
                "author": "IVD",
                "availabilityImpact": null,
                "baseScore": null,
                "confidentialityImpact": null,
                "exploitabilityScore": null,
                "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d",
                "impactScore": null,
                "integrityImpact": null,
                "severity": null,
                "trust": 0.2,
                "vectorString": null,
                "version": "unknown"
              }
            ],
            "cvssV3": [],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2010-4740",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CARNEGIE MELLON",
                "id": "VU#660688",
                "trust": 0.8,
                "value": "3.22"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201102-232",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "IVD",
                "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1",
                "trust": 0.2,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "db": "NVD",
            "id": "CVE-2010-4740"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Stack-based buffer overflow in WTclient.dll in SCADA Engine BACnet OPC Client before 1.0.25 allows user-assisted remote attackers to execute arbitrary code via a crafted .csv file, related to a status log message. This vulnerability WTclient.dll Due to the library. SCADA is the data acquisition and monitoring control system. BACnet OPC Client is prone to a buffer-overflow vulnerability because it fails to perform adequate boundary checks on user-supplied data. Failed exploit attempts will likely result in denial-of-service conditions. ----------------------------------------------------------------------\n\n\nWindows Applications Insecure Library Loading\n\nThe Official, Verified Secunia List:\nhttp://secunia.com/advisories/windows_insecure_library_loading/\n\nThe list is continuously updated as we confirm the vulnerability reports so check back regularly too see if any of your apps are affected. \n\n\n----------------------------------------------------------------------\n\nTITLE:\nSCADA Engine BACnet OPC Client Buffer Overflow Vulnerability\n\nSECUNIA ADVISORY ID:\nSA41466\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/41466/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=41466\n\nRELEASE DATE:\n2010-09-18\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/41466/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/41466/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=41466\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nA vulnerability has been discovered in SCADA Engine BACnet OPC\nClient, which can be exploited by malicious people to compromise a\nuser\u0027s system. tricking a user into opening a\nspecially crafted *.csv file. \n\nThe vulnerability is confirmed in version 1.0.24. Other versions may\nalso be affected. \n\nSOLUTION:\nDo not open untrusted files. \n\nPROVIDED AND/OR DISCOVERED BY:\nJeremy Brown\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2010-4740"
          },
          {
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          },
          {
            "db": "BID",
            "id": "43289"
          },
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "PACKETSTORM",
            "id": "93978"
          }
        ],
        "trust": 3.6
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "SECUNIA",
            "id": "41466",
            "trust": 3.9
          },
          {
            "db": "BID",
            "id": "43289",
            "trust": 3.5
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-10-264-01",
            "trust": 3.2
          },
          {
            "db": "CERT/CC",
            "id": "VU#660688",
            "trust": 3.2
          },
          {
            "db": "NVD",
            "id": "CVE-2010-4740",
            "trust": 2.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060",
            "trust": 1.0
          },
          {
            "db": "SREASON",
            "id": "8083",
            "trust": 1.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232",
            "trust": 0.6
          },
          {
            "db": "IVD",
            "id": "7D7A45C1-463F-11E9-BBB9-000C29342CB1",
            "trust": 0.2
          },
          {
            "db": "IVD",
            "id": "8CB14B48-1FAE-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          },
          {
            "db": "PACKETSTORM",
            "id": "93978",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          },
          {
            "db": "BID",
            "id": "43289"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "db": "PACKETSTORM",
            "id": "93978"
          },
          {
            "db": "NVD",
            "id": "CVE-2010-4740"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ]
      },
      "id": "VAR-201102-0181",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          }
        ],
        "trust": 1.84375
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 1.0
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:20:18.233000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Distributors",
            "trust": 0.8,
            "url": "http://www.scadaengine.com/distributor.html"
          },
          {
            "title": "SCADA Engine - Downloads",
            "trust": 0.8,
            "url": "http://www.scadaengine.com/downloads.html"
          },
          {
            "title": "SCADA Engine - Home",
            "trust": 0.8,
            "url": "http://www.scadaengine.com/index.html"
          },
          {
            "title": "Patch for SCADA Engine BACnet OPC Client Buffer Overflow Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/3032"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-119",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "db": "NVD",
            "id": "CVE-2010-4740"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.2,
            "url": "http://www.securityfocus.com/bid/43289"
          },
          {
            "trust": 3.2,
            "url": "http://www.us-cert.gov/control_systems/pdf/icsa-10-264-01.pdf"
          },
          {
            "trust": 2.4,
            "url": "http://secunia.com/advisories/41466"
          },
          {
            "trust": 2.4,
            "url": "http://www.kb.cert.org/vuls/id/660688"
          },
          {
            "trust": 1.6,
            "url": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt"
          },
          {
            "trust": 1.5,
            "url": "http://secunia.com/advisories/41466/"
          },
          {
            "trust": 1.0,
            "url": "http://securityreason.com/securityalert/8083"
          },
          {
            "trust": 0.8,
            "url": "http://www.scadaengine.com/software1.html"
          },
          {
            "trust": 0.8,
            "url": "http://www.scadaengine.com/downloads.html"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2010-4740"
          },
          {
            "trust": 0.8,
            "url": "http://jvn.jp/cert/jvnvu660688"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2010-4740"
          },
          {
            "trust": 0.3,
            "url": "http://www.scadaengine.com/software7.html"
          },
          {
            "trust": 0.1,
            "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=41466"
          },
          {
            "trust": 0.1,
            "url": "http://secunia.com/advisories/41466/#comments"
          },
          {
            "trust": 0.1,
            "url": "http://secunia.com/products/corporate/evm/"
          },
          {
            "trust": 0.1,
            "url": "http://secunia.com/advisories/secunia_security_advisories/"
          },
          {
            "trust": 0.1,
            "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
          },
          {
            "trust": 0.1,
            "url": "http://secunia.com/advisories/windows_insecure_library_loading/"
          },
          {
            "trust": 0.1,
            "url": "http://secunia.com/vulnerability_scanning/personal/"
          },
          {
            "trust": 0.1,
            "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
          },
          {
            "trust": 0.1,
            "url": "http://secunia.com/advisories/about_secunia_advisories/"
          }
        ],
        "sources": [
          {
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          },
          {
            "db": "BID",
            "id": "43289"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "db": "PACKETSTORM",
            "id": "93978"
          },
          {
            "db": "NVD",
            "id": "CVE-2010-4740"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          },
          {
            "db": "BID",
            "id": "43289"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "db": "PACKETSTORM",
            "id": "93978"
          },
          {
            "db": "NVD",
            "id": "CVE-2010-4740"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2010-09-19T00:00:00",
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "date": "2010-09-19T00:00:00",
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2011-02-03T00:00:00",
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "date": "2010-09-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          },
          {
            "date": "2010-09-16T00:00:00",
            "db": "BID",
            "id": "43289"
          },
          {
            "date": "2011-03-03T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "date": "2010-09-18T10:27:24",
            "db": "PACKETSTORM",
            "id": "93978"
          },
          {
            "date": "2011-02-16T03:00:03.633000",
            "db": "NVD",
            "id": "CVE-2010-4740"
          },
          {
            "date": "2011-02-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2011-02-03T00:00:00",
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "date": "2010-09-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          },
          {
            "date": "2011-02-16T06:29:00",
            "db": "BID",
            "id": "43289"
          },
          {
            "date": "2011-03-03T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2011-001152"
          },
          {
            "date": "2011-09-22T03:27:13.570000",
            "db": "NVD",
            "id": "CVE-2010-4740"
          },
          {
            "date": "2011-02-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SCADA engine BACnet OPC Client Buffer Overflow Vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CERT/CC",
            "id": "VU#660688"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2010-2060"
          }
        ],
        "trust": 1.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Buffer overflow",
        "sources": [
          {
            "db": "IVD",
            "id": "7d7a45c1-463f-11e9-bbb9-000c29342cb1"
          },
          {
            "db": "IVD",
            "id": "8cb14b48-1fae-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201102-232"
          }
        ],
        "trust": 1.0
      }
    }

    CVE-2015-0981 (GCVE-0-2015-0981)

    Vulnerability from nvd – Published: 2015-03-14 01:00 – Updated: 2024-08-06 04:26
    VLAI
    Summary
    The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-03-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T04:26:11.513Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-03-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-03-14T01:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2015-0981",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2015-0981",
        "datePublished": "2015-03-14T01:00:00.000Z",
        "dateReserved": "2015-01-10T00:00:00.000Z",
        "dateUpdated": "2024-08-06T04:26:11.513Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-0980 (GCVE-0-2015-0980)

    Vulnerability from nvd – Published: 2015-03-14 01:00 – Updated: 2024-08-06 04:26
    VLAI
    Summary
    Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-03-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T04:26:11.502Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-03-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-03-14T01:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2015-0980",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2015-0980",
        "datePublished": "2015-03-14T01:00:00.000Z",
        "dateReserved": "2015-01-10T00:00:00.000Z",
        "dateUpdated": "2024-08-06T04:26:11.502Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-0979 (GCVE-0-2015-0979)

    Vulnerability from nvd – Published: 2015-03-14 01:00 – Updated: 2024-08-06 04:26
    VLAI
    Summary
    Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-03-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T04:26:11.571Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-03-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-03-14T01:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2015-0979",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2015-0979",
        "datePublished": "2015-03-14T01:00:00.000Z",
        "dateReserved": "2015-01-10T00:00:00.000Z",
        "dateUpdated": "2024-08-06T04:26:11.571Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2010-4740 (GCVE-0-2010-4740)

    Vulnerability from nvd – Published: 2011-02-16 01:00 – Updated: 2024-08-07 03:55
    VLAI
    Summary
    Stack-based buffer overflow in WTclient.dll in SCADA Engine BACnet OPC Client before 1.0.25 allows user-assisted remote attackers to execute arbitrary code via a crafted .csv file, related to a status log message.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://www.us-cert.gov/control_systems/pdf/ICSA-1… x_refsource_MISC
    http://securityreason.com/securityalert/8083 third-party-advisoryx_refsource_SREASON
    http://secunia.com/advisories/41466 third-party-advisoryx_refsource_SECUNIA
    http://packetstormsecurity.org/1009-exploits/bacn… x_refsource_MISC
    http://www.securityfocus.com/bid/43289 vdb-entryx_refsource_BID
    http://www.kb.cert.org/vuls/id/660688 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2010-09-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T03:55:35.024Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-10-264-01.pdf"
              },
              {
                "name": "8083",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SREASON",
                  "x_transferred"
                ],
                "url": "http://securityreason.com/securityalert/8083"
              },
              {
                "name": "41466",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/41466"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt"
              },
              {
                "name": "43289",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/43289"
              },
              {
                "name": "VU#660688",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/660688"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2010-09-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Stack-based buffer overflow in WTclient.dll in SCADA Engine BACnet OPC Client before 1.0.25 allows user-assisted remote attackers to execute arbitrary code via a crafted .csv file, related to a status log message."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2011-09-22T09:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-10-264-01.pdf"
            },
            {
              "name": "8083",
              "tags": [
                "third-party-advisory",
                "x_refsource_SREASON"
              ],
              "url": "http://securityreason.com/securityalert/8083"
            },
            {
              "name": "41466",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/41466"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt"
            },
            {
              "name": "43289",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/43289"
            },
            {
              "name": "VU#660688",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/660688"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2010-4740",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Stack-based buffer overflow in WTclient.dll in SCADA Engine BACnet OPC Client before 1.0.25 allows user-assisted remote attackers to execute arbitrary code via a crafted .csv file, related to a status log message."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-10-264-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-10-264-01.pdf"
                },
                {
                  "name": "8083",
                  "refsource": "SREASON",
                  "url": "http://securityreason.com/securityalert/8083"
                },
                {
                  "name": "41466",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/41466"
                },
                {
                  "name": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt"
                },
                {
                  "name": "43289",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/43289"
                },
                {
                  "name": "VU#660688",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/660688"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2010-4740",
        "datePublished": "2011-02-16T01:00:00.000Z",
        "dateReserved": "2011-02-15T00:00:00.000Z",
        "dateUpdated": "2024-08-07T03:55:35.024Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-0979 (GCVE-0-2015-0979)

    Vulnerability from cvelistv5 – Published: 2015-03-14 01:00 – Updated: 2024-08-06 04:26
    VLAI
    Summary
    Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-03-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T04:26:11.571Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-03-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-03-14T01:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2015-0979",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2015-0979",
        "datePublished": "2015-03-14T01:00:00.000Z",
        "dateReserved": "2015-01-10T00:00:00.000Z",
        "dateUpdated": "2024-08-06T04:26:11.571Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-0981 (GCVE-0-2015-0981)

    Vulnerability from cvelistv5 – Published: 2015-03-14 01:00 – Updated: 2024-08-06 04:26
    VLAI
    Summary
    The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-03-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T04:26:11.513Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-03-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-03-14T01:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2015-0981",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2015-0981",
        "datePublished": "2015-03-14T01:00:00.000Z",
        "dateReserved": "2015-01-10T00:00:00.000Z",
        "dateUpdated": "2024-08-06T04:26:11.513Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2015-0980 (GCVE-0-2015-0980)

    Vulnerability from cvelistv5 – Published: 2015-03-14 01:00 – Updated: 2024-08-06 04:26
    VLAI
    Summary
    Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Date Public
    2015-03-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T04:26:11.502Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2015-03-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2015-03-14T01:57:01.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "ID": "CVE-2015-0980",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-069-03"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2015-0980",
        "datePublished": "2015-03-14T01:00:00.000Z",
        "dateReserved": "2015-01-10T00:00:00.000Z",
        "dateUpdated": "2024-08-06T04:26:11.502Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2010-4740 (GCVE-0-2010-4740)

    Vulnerability from cvelistv5 – Published: 2011-02-16 01:00 – Updated: 2024-08-07 03:55
    VLAI
    Summary
    Stack-based buffer overflow in WTclient.dll in SCADA Engine BACnet OPC Client before 1.0.25 allows user-assisted remote attackers to execute arbitrary code via a crafted .csv file, related to a status log message.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    http://www.us-cert.gov/control_systems/pdf/ICSA-1… x_refsource_MISC
    http://securityreason.com/securityalert/8083 third-party-advisoryx_refsource_SREASON
    http://secunia.com/advisories/41466 third-party-advisoryx_refsource_SECUNIA
    http://packetstormsecurity.org/1009-exploits/bacn… x_refsource_MISC
    http://www.securityfocus.com/bid/43289 vdb-entryx_refsource_BID
    http://www.kb.cert.org/vuls/id/660688 third-party-advisoryx_refsource_CERT-VN
    Date Public
    2010-09-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-07T03:55:35.024Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-10-264-01.pdf"
              },
              {
                "name": "8083",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SREASON",
                  "x_transferred"
                ],
                "url": "http://securityreason.com/securityalert/8083"
              },
              {
                "name": "41466",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_SECUNIA",
                  "x_transferred"
                ],
                "url": "http://secunia.com/advisories/41466"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt"
              },
              {
                "name": "43289",
                "tags": [
                  "vdb-entry",
                  "x_refsource_BID",
                  "x_transferred"
                ],
                "url": "http://www.securityfocus.com/bid/43289"
              },
              {
                "name": "VU#660688",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/660688"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2010-09-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Stack-based buffer overflow in WTclient.dll in SCADA Engine BACnet OPC Client before 1.0.25 allows user-assisted remote attackers to execute arbitrary code via a crafted .csv file, related to a status log message."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2011-09-22T09:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-10-264-01.pdf"
            },
            {
              "name": "8083",
              "tags": [
                "third-party-advisory",
                "x_refsource_SREASON"
              ],
              "url": "http://securityreason.com/securityalert/8083"
            },
            {
              "name": "41466",
              "tags": [
                "third-party-advisory",
                "x_refsource_SECUNIA"
              ],
              "url": "http://secunia.com/advisories/41466"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt"
            },
            {
              "name": "43289",
              "tags": [
                "vdb-entry",
                "x_refsource_BID"
              ],
              "url": "http://www.securityfocus.com/bid/43289"
            },
            {
              "name": "VU#660688",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/660688"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2010-4740",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Stack-based buffer overflow in WTclient.dll in SCADA Engine BACnet OPC Client before 1.0.25 allows user-assisted remote attackers to execute arbitrary code via a crafted .csv file, related to a status log message."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-10-264-01.pdf",
                  "refsource": "MISC",
                  "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-10-264-01.pdf"
                },
                {
                  "name": "8083",
                  "refsource": "SREASON",
                  "url": "http://securityreason.com/securityalert/8083"
                },
                {
                  "name": "41466",
                  "refsource": "SECUNIA",
                  "url": "http://secunia.com/advisories/41466"
                },
                {
                  "name": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.org/1009-exploits/bacnet-overflow.py.txt"
                },
                {
                  "name": "43289",
                  "refsource": "BID",
                  "url": "http://www.securityfocus.com/bid/43289"
                },
                {
                  "name": "VU#660688",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/660688"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2010-4740",
        "datePublished": "2011-02-16T01:00:00.000Z",
        "dateReserved": "2011-02-15T00:00:00.000Z",
        "dateUpdated": "2024-08-07T03:55:35.024Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }