Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    2 vulnerabilities by arm_trusted_firmware_project

    CVE-2016-10319 (GCVE-0-2016-10319)

    Vulnerability from nvd – Published: 2017-04-06 15:00 – Updated: 2024-09-16 17:37
    VLAI
    Summary
    In ARM Trusted Firmware 1.2 and 1.3, a malformed firmware update SMC can result in copying unexpectedly large data into secure memory because of integer overflows. This affects certain cases involving execution of both AArch64 Generic Trusted Firmware (TF) BL1 code and other firmware update code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T03:14:43.008Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://github.com/ARM-software/arm-trusted-firmware/wiki/ARM-Trusted-Firmware-Security-Advisory-TFV-1"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ARM Trusted Firmware 1.2 and 1.3, a malformed firmware update SMC can result in copying unexpectedly large data into secure memory because of integer overflows. This affects certain cases involving execution of both AArch64 Generic Trusted Firmware (TF) BL1 code and other firmware update code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-04-06T15:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/ARM-software/arm-trusted-firmware/wiki/ARM-Trusted-Firmware-Security-Advisory-TFV-1"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2016-10319",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ARM Trusted Firmware 1.2 and 1.3, a malformed firmware update SMC can result in copying unexpectedly large data into secure memory because of integer overflows. This affects certain cases involving execution of both AArch64 Generic Trusted Firmware (TF) BL1 code and other firmware update code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/ARM-software/arm-trusted-firmware/wiki/ARM-Trusted-Firmware-Security-Advisory-TFV-1",
                  "refsource": "CONFIRM",
                  "url": "https://github.com/ARM-software/arm-trusted-firmware/wiki/ARM-Trusted-Firmware-Security-Advisory-TFV-1"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2016-10319",
        "datePublished": "2017-04-06T15:00:00.000Z",
        "dateReserved": "2017-04-06T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:37:44.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2016-10319 (GCVE-0-2016-10319)

    Vulnerability from cvelistv5 – Published: 2017-04-06 15:00 – Updated: 2024-09-16 17:37
    VLAI
    Summary
    In ARM Trusted Firmware 1.2 and 1.3, a malformed firmware update SMC can result in copying unexpectedly large data into secure memory because of integer overflows. This affects certain cases involving execution of both AArch64 Generic Trusted Firmware (TF) BL1 code and other firmware update code.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T03:14:43.008Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://github.com/ARM-software/arm-trusted-firmware/wiki/ARM-Trusted-Firmware-Security-Advisory-TFV-1"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In ARM Trusted Firmware 1.2 and 1.3, a malformed firmware update SMC can result in copying unexpectedly large data into secure memory because of integer overflows. This affects certain cases involving execution of both AArch64 Generic Trusted Firmware (TF) BL1 code and other firmware update code."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2017-04-06T15:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://github.com/ARM-software/arm-trusted-firmware/wiki/ARM-Trusted-Firmware-Security-Advisory-TFV-1"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2016-10319",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In ARM Trusted Firmware 1.2 and 1.3, a malformed firmware update SMC can result in copying unexpectedly large data into secure memory because of integer overflows. This affects certain cases involving execution of both AArch64 Generic Trusted Firmware (TF) BL1 code and other firmware update code."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/ARM-software/arm-trusted-firmware/wiki/ARM-Trusted-Firmware-Security-Advisory-TFV-1",
                  "refsource": "CONFIRM",
                  "url": "https://github.com/ARM-software/arm-trusted-firmware/wiki/ARM-Trusted-Firmware-Security-Advisory-TFV-1"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2016-10319",
        "datePublished": "2017-04-06T15:00:00.000Z",
        "dateReserved": "2017-04-06T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:37:44.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }