Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    4 vulnerabilities by archos

    VAR-201911-1282

    Vulnerability from variot - Updated: 2023-12-18 13:56

    On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. Archos Safe-T The device contains an information disclosure vulnerability.Information may be obtained. Archos Safe-T is a hardware-based cryptocurrency wallet device. The vulnerability is caused by a configuration error such as a network system or a product running. An unauthorized attacker can exploit the vulnerability to obtain sensitive information about the affected component

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201911-1282",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "safe-t",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "archos",
            "version": null
          },
          {
            "model": "safe-t",
            "scope": null,
            "trust": 1.4,
            "vendor": "archos",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:archos:safe-t:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-14358"
          }
        ]
      },
      "cve": "CVE-2019-14358",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 1.9,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.4,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "LOW",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Local",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 1.9,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2019-14358",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Low",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 2.1,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2019-40098",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Physical",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.6,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2019-14358",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-14358",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2019-40098",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201911-043",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device\u0027s USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. Archos Safe-T The device contains an information disclosure vulnerability.Information may be obtained. Archos Safe-T is a hardware-based cryptocurrency wallet device. The vulnerability is caused by a configuration error such as a network system or a product running. An unauthorized attacker can exploit the vulnerability to obtain sensitive information about the affected component",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-14358"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-14358",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-043",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ]
      },
      "id": "VAR-201911-1282",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          }
        ],
        "trust": 1.225
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:56:29.604000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.archos.com/fr/home.html"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-203",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-200",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14358"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "https://blog.inhq.net/posts/oled-side-channel-status-summary/"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-14358"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-14358"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-14358"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-11-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          },
          {
            "date": "2019-11-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "date": "2019-11-02T17:15:10.477000",
            "db": "NVD",
            "id": "CVE-2019-14358"
          },
          {
            "date": "2019-11-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-11-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          },
          {
            "date": "2019-11-18T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-011722"
          },
          {
            "date": "2021-07-21T11:39:23.747000",
            "db": "NVD",
            "id": "CVE-2019-14358"
          },
          {
            "date": "2019-11-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ]
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Archos Safe-T Information Disclosure Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2019-40098"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-043"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201911-0456

    Vulnerability from variot - Updated: 2023-12-18 13:38

    The Archos Core 101 Android device with a build fingerprint of archos/MTKAC101CR3G_ARCHOS/ac101cr3g:7.0/NRD90M/20180611.034442:user/release-keys contains a pre-installed app with a package name of com.roco.autogen app (versionCode=1, versionName=1) that allows any app co-located on the device to programmatically disable and enable Wi-Fi without the corresponding access permission through an exported interface. Archos Core 101 Android Devices are vulnerable to improper assignment of permissions to critical resources.Information may be tampered with. Archos Core 101 is a tablet computer from Archos, France.

    Archos Core 101 has an access control error vulnerability. The vulnerability stems from a network system or product that did not properly restrict access to resources from unauthorized roles. An attacker could use this vulnerability to unauthorizedly disable and enable Wi-Fi

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201911-0456",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "core 101",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "archos",
            "version": null
          },
          {
            "model": "core 101",
            "scope": null,
            "trust": 0.8,
            "vendor": "archos",
            "version": null
          },
          {
            "model": "core",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "archos",
            "version": "101"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15387"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:archos:core_101_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:archos:core_101:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-15387"
          }
        ]
      },
      "cve": "CVE-2019-15387",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 2.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "LOW",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Local",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 2.1,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2019-15387",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Low",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 2.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2020-16015",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 1.8,
                "impactScore": 1.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Local",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 3.3,
                "baseSeverity": "Low",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2019-15387",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2019-15387",
                "trust": 1.8,
                "value": "LOW"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-16015",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201911-885",
                "trust": 0.6,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15387"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "The Archos Core 101 Android device with a build fingerprint of archos/MTKAC101CR3G_ARCHOS/ac101cr3g:7.0/NRD90M/20180611.034442:user/release-keys contains a pre-installed app with a package name of com.roco.autogen app (versionCode=1, versionName=1) that allows any app co-located on the device to programmatically disable and enable Wi-Fi without the corresponding access permission through an exported interface. Archos Core 101 Android Devices are vulnerable to improper assignment of permissions to critical resources.Information may be tampered with. Archos Core 101 is a tablet computer from Archos, France. \n\r\n\r\nArchos Core 101 has an access control error vulnerability. The vulnerability stems from a network system or product that did not properly restrict access to resources from unauthorized roles. An attacker could use this vulnerability to unauthorizedly disable and enable Wi-Fi",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2019-15387"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2019-15387",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-885",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15387"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ]
      },
      "id": "VAR-201911-0456",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          }
        ],
        "trust": 1.6
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          }
        ]
      },
      "last_update_date": "2023-12-18T13:38:05.372000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Tablets",
            "trust": 0.8,
            "url": "https://www.archos.com/us/products/tablets/"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-862",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-732",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15387"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.4,
            "url": "https://www.kryptowire.com/android-firmware-2019/"
          },
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2019-15387"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-15387"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15387"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "db": "NVD",
            "id": "CVE-2019-15387"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-03-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          },
          {
            "date": "2019-11-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "date": "2019-11-14T17:15:18.927000",
            "db": "NVD",
            "id": "CVE-2019-15387"
          },
          {
            "date": "2019-11-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-03-08T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          },
          {
            "date": "2019-11-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2019-012169"
          },
          {
            "date": "2020-08-24T17:37:01.140000",
            "db": "NVD",
            "id": "CVE-2019-15387"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Archos Core 101 Access Control Error Vulnerability",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-16015"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "access control error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201911-885"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2019-14358 (GCVE-0-2019-14358)

    Vulnerability from cvelistv5 – Published: 2019-11-02 16:26 – Updated: 2024-08-05 00:12
    VLAI
    Summary
    On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:12:43.565Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.inhq.net/posts/oled-side-channel-status-summary/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device\u0027s USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-11-02T16:26:43.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.inhq.net/posts/oled-side-channel-status-summary/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-14358",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device\u0027s USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://blog.inhq.net/posts/oled-side-channel-status-summary/",
                  "refsource": "MISC",
                  "url": "https://blog.inhq.net/posts/oled-side-channel-status-summary/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-14358",
        "datePublished": "2019-11-02T16:26:43.000Z",
        "dateReserved": "2019-07-28T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:12:43.565Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2019-14358 (GCVE-0-2019-14358)

    Vulnerability from nvd – Published: 2019-11-02 16:26 – Updated: 2024-08-05 00:12
    VLAI
    Summary
    On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T00:12:43.565Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.inhq.net/posts/oled-side-channel-status-summary/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device\u0027s USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-11-02T16:26:43.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.inhq.net/posts/oled-side-channel-status-summary/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2019-14358",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "On Archos Safe-T devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device\u0027s USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://blog.inhq.net/posts/oled-side-channel-status-summary/",
                  "refsource": "MISC",
                  "url": "https://blog.inhq.net/posts/oled-side-channel-status-summary/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-14358",
        "datePublished": "2019-11-02T16:26:43.000Z",
        "dateReserved": "2019-07-28T00:00:00.000Z",
        "dateUpdated": "2024-08-05T00:12:43.565Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }