    VAR-201803-1560

    Vulnerability from variot - Updated: 2023-12-18 12:18

    This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Customer-Link App and Customer-Link Bridge. The issue results from the lack of a proper protection mechanism against unauthorized firmware updates. An attacker can leverage this vulnerability to inject CAN messages. Was ZDI-CAN-5264. Volkswagen Customer-Link Application and HTC Customer-Link Bridge Contains an injection vulnerability. Zero Day Initiative Is vulnerable to this vulnerability ZDI-CAN-5264 Was numbered.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Volkswagen Customer-Link App is a mobile application for Volkswagen Automotive Company to monitor vehicle status. HTC Customer-Link Bridge is an IoT device jointly released by Volkswagen Automotive and HTC, used to monitor vehicle information and provide other road information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201803-1560",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "customer-link",
            "scope": "eq",
            "trust": 1.8,
            "vendor": "volkswagen",
            "version": "1.30"
          },
          {
            "model": "customer-link bridge",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "htc",
            "version": null
          },
          {
            "model": "customer-link bridge",
            "scope": null,
            "trust": 0.8,
            "vendor": "htc",
            "version": null
          },
          {
            "model": "customer-link app",
            "scope": null,
            "trust": 0.7,
            "vendor": "volkswagen",
            "version": null
          },
          {
            "model": "customer-link app",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "volkswagen",
            "version": "1.30"
          },
          {
            "model": "htc customer-link bridge",
            "scope": null,
            "trust": 0.6,
            "vendor": "volkswagen",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-18-214"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-1170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:volkswagen:customer-link:1.30:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:a:htc:customer-link_bridge:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-1170"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Aaron Luo Spencer Hsieh (TrendMicro)",
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-18-214"
          }
        ],
        "trust": 0.7
      },
      "cve": "CVE-2018-1170",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 8.3,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2018-1170",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 1.5,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 8.3,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2018-05971",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-1170",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-1170",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "ZDI",
                "id": "CVE-2018-1170",
                "trust": 0.7,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2018-05971",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201803-101",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-18-214"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-1170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Customer-Link App and Customer-Link Bridge. The issue results from the lack of a proper protection mechanism against unauthorized firmware updates. An attacker can leverage this vulnerability to inject CAN messages. Was ZDI-CAN-5264. Volkswagen Customer-Link Application and HTC Customer-Link Bridge Contains an injection vulnerability. Zero Day Initiative Is vulnerable to this vulnerability ZDI-CAN-5264 Was numbered.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Volkswagen Customer-Link App is a mobile application for Volkswagen Automotive Company to monitor vehicle status. HTC Customer-Link Bridge is an IoT device jointly released by Volkswagen Automotive and HTC, used to monitor vehicle information and provide other road information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-1170"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "db": "ZDI",
            "id": "ZDI-18-214"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ],
        "trust": 3.33
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-1170",
            "trust": 3.7
          },
          {
            "db": "ZDI",
            "id": "ZDI-18-214",
            "trust": 3.7
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486",
            "trust": 0.8
          },
          {
            "db": "ZDI_CAN",
            "id": "ZDI-CAN-5264",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "ZDI",
            "id": "ZDI-18-214"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-1170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ]
      },
      "id": "VAR-201803-1560",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          }
        ],
        "trust": 1.475
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "IoT"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:18:59.970000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "HTC AND VOLKSWAGEN JOIN FORCES ON THE INTERNET OF VEHICLES",
            "trust": 0.8,
            "url": "https://www.htc.com/us/about/newsroom/2015/2015-12-25-htc-and-volkswagen-join-forces-on-the-internet-of-vehicles/"
          },
          {
            "title": "Patch for Volkswagen Customer-Link App and HTC Customer-Link Bridge injection vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/122619"
          },
          {
            "title": "Volkswagen Customer-Link App  and HTC Customer-Link Bridge Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=78889"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-Other",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-74",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-1170"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.2,
            "url": "https://zerodayinitiative.com/advisories/zdi-18-214"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-1170"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-1170"
          },
          {
            "trust": 0.8,
            "url": "https://www.zerodayinitiative.com/advisories/zdi-18-214/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-1170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "ZDI",
            "id": "ZDI-18-214"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-1170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-02-27T00:00:00",
            "db": "ZDI",
            "id": "ZDI-18-214"
          },
          {
            "date": "2018-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "date": "2018-04-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "date": "2018-03-02T01:29:00.317000",
            "db": "NVD",
            "id": "CVE-2018-1170"
          },
          {
            "date": "2018-03-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-02-27T00:00:00",
            "db": "ZDI",
            "id": "ZDI-18-214"
          },
          {
            "date": "2018-03-22T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-05971"
          },
          {
            "date": "2018-04-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          },
          {
            "date": "2020-08-28T15:16:09.567000",
            "db": "NVD",
            "id": "CVE-2018-1170"
          },
          {
            "date": "2019-10-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Volkswagen Customer-Link Application and  HTC Customer-Link Bridge Injection vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002486"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201803-101"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2023-6073 (GCVE-0-2023-6073)

    Vulnerability from cvelistv5 – Published: 2023-11-10 07:32 – Updated: 2025-02-27 20:34 X_Automotive X_Volkswagen X_Vw X_Ivi
    VLAI
    Title
    DoS and Control of Volume Settings for VW ID.3 ICAS3 IVI ECU
    Summary
    Attacker can perform a Denial of Service attack to crash the ICAS 3 IVI ECU in a Volkswagen ID.3 (and other vehicles of the VW Group with the same hardware) and spoof volume setting commands to irreversibly turn on audio volume to maximum via REST API calls.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    Volkswagen ID.3 Affected: 0 , < 3.2 (custom)
    Create a notification for this product.
    Credits
    Hannah Wieser Jannis Hamborg Timm Lauser Thomas Schäfer Christoph Krauß
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:21:17.281Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://asrg.io/cve-2023-6073-dos-and-control-of-volume-settings-for-vw-id-3-icas3-ivi-ecu/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-6073",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-27T20:31:42.577215Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-27T20:34:00.676Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "ICAS 3 IVI ECU"
              ],
              "product": "ID.3",
              "vendor": "Volkswagen",
              "versions": [
                {
                  "lessThan": "3.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hannah Wieser"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Jannis Hamborg"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Timm Lauser"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Thomas Sch\u00e4fer"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Christoph Krau\u00df"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAttacker can perform a Denial of Service attack to crash the ICAS 3 IVI ECU in a Volkswagen ID.3 (and other vehicles of the VW Group with the same hardware) and spoof volume setting commands to irreversibly turn on audio volume to maximum via REST API calls.\u003c/span\u003e\u003cbr\u003e"
                }
              ],
              "value": "Attacker can perform a Denial of Service attack to crash the ICAS 3 IVI ECU in a Volkswagen ID.3 (and other vehicles of the VW Group with the same hardware) and spoof volume setting commands to irreversibly turn on audio volume to maximum via REST API calls.\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-173",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-173 Action Spoofing"
                }
              ]
            },
            {
              "capecId": "CAPEC-624",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-624 Fault Injection"
                }
              ]
            },
            {
              "capecId": "CAPEC-212",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-212 Functionality Misuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Volume Control"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "DoS"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-10T07:32:16.964Z",
            "orgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
            "shortName": "ASRG"
          },
          "references": [
            {
              "url": "https://asrg.io/cve-2023-6073-dos-and-control-of-volume-settings-for-vw-id-3-icas3-ivi-ecu/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "x_Automotive",
            "x_Volkswagen",
            "x_VW",
            "x_IVI"
          ],
          "title": "DoS and Control of Volume Settings for VW ID.3 ICAS3 IVI ECU",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
        "assignerShortName": "ASRG",
        "cveId": "CVE-2023-6073",
        "datePublished": "2023-11-10T07:32:16.964Z",
        "dateReserved": "2023-11-10T07:06:53.421Z",
        "dateUpdated": "2025-02-27T20:34:00.676Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-1170 (GCVE-0-2018-1170)

    Vulnerability from cvelistv5 – Published: 2018-03-02 01:00 – Updated: 2024-08-05 03:51
    VLAI
    Summary
    This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Customer-Link App and Customer-Link Bridge. The issue results from the lack of a proper protection mechanism against unauthorized firmware updates. An attacker can leverage this vulnerability to inject CAN messages. Was ZDI-CAN-5264.
    Severity
    No CVSS data available.
    CWE
    • CWE-693 - Protection Mechanism Failure
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2018-02-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T03:51:48.902Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://zerodayinitiative.com/advisories/ZDI-18-214"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Volkswagen Customer-Link App",
              "vendor": "Volkswagen",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.30"
                }
              ]
            }
          ],
          "datePublic": "2018-02-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Customer-Link App and Customer-Link Bridge. The issue results from the lack of a proper protection mechanism against unauthorized firmware updates. An attacker can leverage this vulnerability to inject CAN messages. Was ZDI-CAN-5264."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-693",
                  "description": "CWE-693-Protection Mechanism Failure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-03-02T00:57:01.000Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://zerodayinitiative.com/advisories/ZDI-18-214"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "zdi-disclosures@trendmicro.com",
              "ID": "CVE-2018-1170",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Volkswagen Customer-Link App",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.30"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Volkswagen"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Customer-Link App and Customer-Link Bridge. The issue results from the lack of a proper protection mechanism against unauthorized firmware updates. An attacker can leverage this vulnerability to inject CAN messages. Was ZDI-CAN-5264."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-693-Protection Mechanism Failure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://zerodayinitiative.com/advisories/ZDI-18-214",
                  "refsource": "MISC",
                  "url": "https://zerodayinitiative.com/advisories/ZDI-18-214"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2018-1170",
        "datePublished": "2018-03-02T01:00:00.000Z",
        "dateReserved": "2017-12-05T00:00:00.000Z",
        "dateUpdated": "2024-08-05T03:51:48.902Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-6073 (GCVE-0-2023-6073)

    Vulnerability from nvd – Published: 2023-11-10 07:32 – Updated: 2025-02-27 20:34 X_Automotive X_Volkswagen X_Vw X_Ivi
    VLAI
    Title
    DoS and Control of Volume Settings for VW ID.3 ICAS3 IVI ECU
    Summary
    Attacker can perform a Denial of Service attack to crash the ICAS 3 IVI ECU in a Volkswagen ID.3 (and other vehicles of the VW Group with the same hardware) and spoof volume setting commands to irreversibly turn on audio volume to maximum via REST API calls.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    Volkswagen ID.3 Affected: 0 , < 3.2 (custom)
    Create a notification for this product.
    Credits
    Hannah Wieser Jannis Hamborg Timm Lauser Thomas Schäfer Christoph Krauß
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T08:21:17.281Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://asrg.io/cve-2023-6073-dos-and-control-of-volume-settings-for-vw-id-3-icas3-ivi-ecu/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-6073",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-27T20:31:42.577215Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-27T20:34:00.676Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "ICAS 3 IVI ECU"
              ],
              "product": "ID.3",
              "vendor": "Volkswagen",
              "versions": [
                {
                  "lessThan": "3.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Hannah Wieser"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Jannis Hamborg"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Timm Lauser"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Thomas Sch\u00e4fer"
            },
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Christoph Krau\u00df"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAttacker can perform a Denial of Service attack to crash the ICAS 3 IVI ECU in a Volkswagen ID.3 (and other vehicles of the VW Group with the same hardware) and spoof volume setting commands to irreversibly turn on audio volume to maximum via REST API calls.\u003c/span\u003e\u003cbr\u003e"
                }
              ],
              "value": "Attacker can perform a Denial of Service attack to crash the ICAS 3 IVI ECU in a Volkswagen ID.3 (and other vehicles of the VW Group with the same hardware) and spoof volume setting commands to irreversibly turn on audio volume to maximum via REST API calls.\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-173",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-173 Action Spoofing"
                }
              ]
            },
            {
              "capecId": "CAPEC-624",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-624 Fault Injection"
                }
              ]
            },
            {
              "capecId": "CAPEC-212",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-212 Functionality Misuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "Volume Control"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "DoS"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-11-10T07:32:16.964Z",
            "orgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
            "shortName": "ASRG"
          },
          "references": [
            {
              "url": "https://asrg.io/cve-2023-6073-dos-and-control-of-volume-settings-for-vw-id-3-icas3-ivi-ecu/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "tags": [
            "x_Automotive",
            "x_Volkswagen",
            "x_VW",
            "x_IVI"
          ],
          "title": "DoS and Control of Volume Settings for VW ID.3 ICAS3 IVI ECU",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
        "assignerShortName": "ASRG",
        "cveId": "CVE-2023-6073",
        "datePublished": "2023-11-10T07:32:16.964Z",
        "dateReserved": "2023-11-10T07:06:53.421Z",
        "dateUpdated": "2025-02-27T20:34:00.676Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-1170 (GCVE-0-2018-1170)

    Vulnerability from nvd – Published: 2018-03-02 01:00 – Updated: 2024-08-05 03:51
    VLAI
    Summary
    This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Customer-Link App and Customer-Link Bridge. The issue results from the lack of a proper protection mechanism against unauthorized firmware updates. An attacker can leverage this vulnerability to inject CAN messages. Was ZDI-CAN-5264.
    Severity
    No CVSS data available.
    CWE
    • CWE-693 - Protection Mechanism Failure
    Assigner
    zdi
    References
    Impacted products
    Date Public
    2018-02-27 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T03:51:48.902Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://zerodayinitiative.com/advisories/ZDI-18-214"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Volkswagen Customer-Link App",
              "vendor": "Volkswagen",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.30"
                }
              ]
            }
          ],
          "datePublic": "2018-02-27T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Customer-Link App and Customer-Link Bridge. The issue results from the lack of a proper protection mechanism against unauthorized firmware updates. An attacker can leverage this vulnerability to inject CAN messages. Was ZDI-CAN-5264."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-693",
                  "description": "CWE-693-Protection Mechanism Failure",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-03-02T00:57:01.000Z",
            "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
            "shortName": "zdi"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://zerodayinitiative.com/advisories/ZDI-18-214"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "zdi-disclosures@trendmicro.com",
              "ID": "CVE-2018-1170",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Volkswagen Customer-Link App",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.30"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Volkswagen"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "This vulnerability allows adjacent attackers to inject arbitrary Controller Area Network messages on vulnerable installations of Volkswagen Customer-Link App 1.30 and HTC Customer-Link Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Customer-Link App and Customer-Link Bridge. The issue results from the lack of a proper protection mechanism against unauthorized firmware updates. An attacker can leverage this vulnerability to inject CAN messages. Was ZDI-CAN-5264."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-693-Protection Mechanism Failure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://zerodayinitiative.com/advisories/ZDI-18-214",
                  "refsource": "MISC",
                  "url": "https://zerodayinitiative.com/advisories/ZDI-18-214"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "assignerShortName": "zdi",
        "cveId": "CVE-2018-1170",
        "datePublished": "2018-03-02T01:00:00.000Z",
        "dateReserved": "2017-12-05T00:00:00.000Z",
        "dateUpdated": "2024-08-05T03:51:48.902Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }