    CVE-2024-35295 (GCVE-0-2024-35295)

    Vulnerability from cvelistv5 – Published: 2025-06-11 06:55 – Updated: 2025-06-12 05:13
    VLAI
    Summary
    A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Innomotics Perfect Harmony GH180 Affected: V8.0 , < V8.3.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-35295",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-11T13:21:32.040525Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-11T13:21:36.605Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Perfect Harmony GH180",
              "vendor": "Innomotics",
              "versions": [
                {
                  "lessThan": "V8.3.3",
                  "status": "affected",
                  "version": "V8.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Perfect Harmony GH180 (All versions \u003e= V8.0 \u003c V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device\u0027s control unit configuration. This could allow an attacker with physical access to the maintenance connection\u0027s door port to perform arbitrary configuration changes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 5.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-12T05:13:25.889Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-771113.html"
            },
            {
              "url": "https://www.innomotics.com/hub/en/ISA-771113"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-35295",
        "datePublished": "2025-06-11T06:55:31.200Z",
        "dateReserved": "2024-05-15T15:36:13.543Z",
        "dateUpdated": "2025-06-12T05:13:25.889Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-35295 (GCVE-0-2024-35295)

    Vulnerability from nvd – Published: 2025-06-11 06:55 – Updated: 2025-06-12 05:13
    VLAI
    Summary
    A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Innomotics Perfect Harmony GH180 Affected: V8.0 , < V8.3.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-35295",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-11T13:21:32.040525Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-11T13:21:36.605Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Perfect Harmony GH180",
              "vendor": "Innomotics",
              "versions": [
                {
                  "lessThan": "V8.3.3",
                  "status": "affected",
                  "version": "V8.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Perfect Harmony GH180 (All versions \u003e= V8.0 \u003c V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device\u0027s control unit configuration. This could allow an attacker with physical access to the maintenance connection\u0027s door port to perform arbitrary configuration changes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 5.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306: Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-12T05:13:25.889Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-771113.html"
            },
            {
              "url": "https://www.innomotics.com/hub/en/ISA-771113"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2024-35295",
        "datePublished": "2025-06-11T06:55:31.200Z",
        "dateReserved": "2024-05-15T15:36:13.543Z",
        "dateUpdated": "2025-06-12T05:13:25.889Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }