Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    1 vulnerability by 3onedata

    CVE-2025-13605 (GCVE-0-2025-13605)

    Vulnerability from cvelistv5 – Published: 2026-05-04 14:52 – Updated: 2026-05-04 15:28
    VLAI
    Title
    Shell command injection in 3onedata GW1101-1D(RS-485)-TB-P modbus gateway
    Summary
    3onedata modbus gateway device model GW1101-1D(RS-485)-TB-P (hardware version V2.2.0) allows authenticated users to execute arbitrary shell commands in the context of the root user by providing payload in the "IP address" field of the diagnosis test tools. This issue has been resolved in firmware version 3.0.59B2024080600R4353
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    URL Tags
    https://cert.pl/en/posts/2026/05/CVE-2025-13605 third-party-advisory
    Impacted products
    Vendor Product Version
    3onedata GW1101-1D(RS-485)-TB-P Affected: 0 , < 3.0.59B2024080600R4353 (custom)
    Create a notification for this product.
    Date Public
    2026-05-04 14:50
    Credits
    Jarosław Wawiórko Łukasz Rybak
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-13605",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-04T15:28:34.977201Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-04T15:28:56.851Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "GW1101-1D(RS-485)-TB-P",
              "vendor": "3onedata",
              "versions": [
                {
                  "lessThan": "3.0.59B2024080600R4353",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Jaros\u0142aw Wawi\u00f3rko"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "\u0141ukasz Rybak"
            }
          ],
          "datePublic": "2026-05-04T14:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "3onedata modbus gateway device model\u0026nbsp;GW1101-1D(RS-485)-TB-P (hardware version V2.2.0)\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eallows authenticated users to execute arbitrary shell commands in the context of the root user by providing payload in the \"IP address\" field of the diagnosis test tools.\u003cbr\u003e\u003c/span\u003eThis issue has been resolved in firmware version 3.0.59B2024080600R4353"
                }
              ],
              "value": "3onedata modbus gateway device model\u00a0GW1101-1D(RS-485)-TB-P (hardware version V2.2.0)\u00a0allows authenticated users to execute arbitrary shell commands in the context of the root user by providing payload in the \"IP address\" field of the diagnosis test tools.\nThis issue has been resolved in firmware version 3.0.59B2024080600R4353"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-04T14:52:39.300Z",
            "orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
            "shortName": "CERT-PL"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://cert.pl/en/posts/2026/05/CVE-2025-13605"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Shell command injection in 3onedata GW1101-1D(RS-485)-TB-P modbus gateway",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
        "assignerShortName": "CERT-PL",
        "cveId": "CVE-2025-13605",
        "datePublished": "2026-05-04T14:52:39.300Z",
        "dateReserved": "2025-11-24T14:44:56.542Z",
        "dateUpdated": "2026-05-04T15:28:56.851Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }