Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    6 vulnerabilities found for sysmac_studio by omron

    CVE-2022-45792 (GCVE-0-2022-45792)

    Vulnerability from cvelistv5 – Published: 2024-01-22 17:46 – Updated: 2025-06-17 21:19
    VLAI
    Title
    Directory Traversal in Project File Format allows overwrite (Zip Slip)
    Summary
    Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Impacted products
    Vendor Product Version
    Omron Sysmac Studio Affected: 0 , < 1.54.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:17:04.101Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45792",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-30T18:36:27.204028Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T21:19:25.577Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "x86",
                "64 bit"
              ],
              "product": "Sysmac Studio",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThan": "1.54.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user."
                }
              ],
              "value": "Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-165",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-165 File Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-22T17:46:36.699Z",
            "orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
            "shortName": "Dragos"
          },
          "references": [
            {
              "url": "https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Directory Traversal in Project File Format allows overwrite (Zip Slip)",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
        "assignerShortName": "Dragos",
        "cveId": "CVE-2022-45792",
        "datePublished": "2024-01-22T17:46:36.699Z",
        "dateReserved": "2022-11-22T17:52:43.198Z",
        "dateUpdated": "2025-06-17T21:19:25.577Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34151 (GCVE-0-2022-34151)

    Vulnerability from cvelistv5 – Published: 2022-07-04 01:51 – Updated: 2026-06-02 19:47
    VLAI
    Summary
    Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of Hard-coded Credentials
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    References
    Impacted products
    Vendor Product Version
    OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:16:17.136Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.4,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34151",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:47:06.554385Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-798",
                    "description": "CWE-798 Use of Hard-coded Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:47:10.923Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
              "vendor": "OMRON Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-04T02:25:19.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2022-34151",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "OMRON Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Use of Hard-coded Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
                },
                {
                  "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2022-34151",
        "datePublished": "2022-07-04T01:51:00.000Z",
        "dateReserved": "2022-06-21T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:47:10.923Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33208 (GCVE-0-2022-33208)

    Vulnerability from cvelistv5 – Published: 2022-07-04 01:50 – Updated: 2024-08-03 08:01
    VLAI
    Summary
    Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.
    Severity
    No CVSS data available.
    CWE
    • Authentication Bypass by Capture-replay
    Assigner
    References
    Impacted products
    Vendor Product Version
    OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:01:20.422Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
              "vendor": "OMRON Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Authentication Bypass by Capture-replay",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-04T02:25:11.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2022-33208",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "OMRON Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Authentication Bypass by Capture-replay"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
                },
                {
                  "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2022-33208",
        "datePublished": "2022-07-04T01:50:44.000Z",
        "dateReserved": "2022-06-21T00:00:00.000Z",
        "dateUpdated": "2024-08-03T08:01:20.422Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45792 (GCVE-0-2022-45792)

    Vulnerability from nvd – Published: 2024-01-22 17:46 – Updated: 2025-06-17 21:19
    VLAI
    Title
    Directory Traversal in Project File Format allows overwrite (Zip Slip)
    Summary
    Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    Impacted products
    Vendor Product Version
    Omron Sysmac Studio Affected: 0 , < 1.54.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:17:04.101Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45792",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-30T18:36:27.204028Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-17T21:19:25.577Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows",
                "x86",
                "64 bit"
              ],
              "product": "Sysmac Studio",
              "vendor": "Omron",
              "versions": [
                {
                  "lessThan": "1.54.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user."
                }
              ],
              "value": "Project files may contain malicious contents which the software will use to create files on the filesystem. This allows directory traversal and overwriting files with the privileges of the logged-in user."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-165",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-165 File Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-22T17:46:36.699Z",
            "orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
            "shortName": "Dragos"
          },
          "references": [
            {
              "url": "https://www.dragos.com/advisory/omron-plc-and-engineering-software-network-and-file-format-access/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Directory Traversal in Project File Format allows overwrite (Zip Slip)",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
        "assignerShortName": "Dragos",
        "cveId": "CVE-2022-45792",
        "datePublished": "2024-01-22T17:46:36.699Z",
        "dateReserved": "2022-11-22T17:52:43.198Z",
        "dateUpdated": "2025-06-17T21:19:25.577Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-34151 (GCVE-0-2022-34151)

    Vulnerability from nvd – Published: 2022-07-04 01:51 – Updated: 2026-06-02 19:47
    VLAI
    Summary
    Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • Use of Hard-coded Credentials
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    References
    Impacted products
    Vendor Product Version
    OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:16:17.136Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.4,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-34151",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:47:06.554385Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-798",
                    "description": "CWE-798 Use of Hard-coded Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:47:10.923Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
              "vendor": "OMRON Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-04T02:25:19.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2022-34151",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "OMRON Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Use of Hard-coded Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
                },
                {
                  "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2022-34151",
        "datePublished": "2022-07-04T01:51:00.000Z",
        "dateReserved": "2022-06-21T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:47:10.923Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-33208 (GCVE-0-2022-33208)

    Vulnerability from nvd – Published: 2022-07-04 01:50 – Updated: 2024-08-03 08:01
    VLAI
    Summary
    Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.
    Severity
    No CVSS data available.
    CWE
    • Authentication Bypass by Capture-replay
    Assigner
    References
    Impacted products
    Vendor Product Version
    OMRON Corporation Machine automation controller NJ series, Machine automation controller NX series, Automation software 'Sysmac Studio', and Programmable Terminal (PT) NA series Affected: Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T08:01:20.422Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
              "vendor": "OMRON Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Authentication Bypass by Capture-replay",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-04T02:25:11.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2022-33208",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Machine automation controller NJ series, Machine automation controller NX series, Automation software \u0027Sysmac Studio\u0027, and Programmable Terminal (PT) NA series",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "OMRON Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software \u0027Sysmac Studio\u0027 all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software \u0027Sysmac Studio\u0027 and/or a Programmable Terminal (PT) to access the controller."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Authentication Bypass by Capture-replay"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf",
                  "refsource": "MISC",
                  "url": "https://www.ia.omron.com/product/vulnerability/OMSR-2022-001_en.pdf"
                },
                {
                  "name": "https://jvn.jp/en/vu/JVNVU97050784/index.html",
                  "refsource": "MISC",
                  "url": "https://jvn.jp/en/vu/JVNVU97050784/index.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2022-33208",
        "datePublished": "2022-07-04T01:50:44.000Z",
        "dateReserved": "2022-06-21T00:00:00.000Z",
        "dateUpdated": "2024-08-03T08:01:20.422Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }