Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    6 vulnerabilities found for maxview_storage_manager by microchip

    CVE-2023-51438 (GCVE-0-2023-51438)

    Vulnerability from cvelistv5 – Published: 2024-01-09 10:00 – Updated: 2025-05-22 17:57
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    Siemens SIMATIC IPC1047E Affected: All versions with maxView Storage Manager < V4.14.00.26068 on Windows
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: All versions with maxView Storage Manager < V4.14.00.26068 on Windows
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: All versions with maxView Storage Manager < V4.14.00.26068 on Windows
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:32:09.431Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-702935.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51438",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-22T17:51:00.924153Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-22T17:57:26.766Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC1047E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC647E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC847E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish\u00ae server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T10:00:13.080Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-702935.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-51438",
        "datePublished": "2024-01-09T10:00:13.080Z",
        "dateReserved": "2023-12-19T11:46:45.583Z",
        "dateUpdated": "2025-05-22T17:57:26.766Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-22216 (GCVE-0-2024-22216)

    Vulnerability from cvelistv5 – Published: 2024-01-08 00:00 – Updated: 2025-06-18 16:54
    VLAI
    Summary
    In default installations of Microchip maxView Storage Manager (for Adaptec Smart Storage Controllers) where Redfish server is configured for remote system management, unauthorized access can occur, with data modification and information disclosure. This affects 3.00.23484 through 4.14.00.26064 (except for the patched versions 3.07.23980 and 4.07.00.25339).
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-284 - Improper Access Control
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T22:35:34.882Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.microchip.com/en-us/solutions/embedded-security/how-to-report-potential-product-security-vulnerabilities/maxview-storage-manager-redfish-server-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-22216",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-08T14:16:33.392817Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-284",
                    "description": "CWE-284 Improper Access Control",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-18T16:54:35.287Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In default installations of Microchip maxView Storage Manager (for Adaptec Smart Storage Controllers) where Redfish server is configured for remote system management, unauthorized access can occur, with data modification and information disclosure. This affects 3.00.23484 through 4.14.00.26064 (except for the patched versions 3.07.23980 and 4.07.00.25339)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-08T06:37:22.420Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.microchip.com/en-us/solutions/embedded-security/how-to-report-potential-product-security-vulnerabilities/maxview-storage-manager-redfish-server-vulnerability"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-22216",
        "datePublished": "2024-01-08T00:00:00.000Z",
        "dateReserved": "2024-01-08T00:00:00.000Z",
        "dateUpdated": "2025-06-18T16:54:35.287Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23588 (GCVE-0-2023-23588)

    Vulnerability from cvelistv5 – Published: 2023-04-11 09:03 – Updated: 2024-10-15 17:12
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application. A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    Impacted products
    Vendor Product Version
    Siemens SIMATIC IPC1047 Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC IPC1047E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
    Create a notification for this product.
    Siemens SIMATIC IPC647D Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
    Create a notification for this product.
    Siemens SIMATIC IPC847D Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:35:33.386Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23588",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T17:09:07.958283Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T17:12:13.841Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC1047",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC1047E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC647D",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC647E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC847D",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC847E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application.\r\nA local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-11T09:03:01.130Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-23588",
        "datePublished": "2023-04-11T09:03:01.130Z",
        "dateReserved": "2023-01-13T14:55:01.563Z",
        "dateUpdated": "2024-10-15T17:12:13.841Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-51438 (GCVE-0-2023-51438)

    Vulnerability from nvd – Published: 2024-01-09 10:00 – Updated: 2025-05-22 17:57
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    Siemens SIMATIC IPC1047E Affected: All versions with maxView Storage Manager < V4.14.00.26068 on Windows
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: All versions with maxView Storage Manager < V4.14.00.26068 on Windows
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: All versions with maxView Storage Manager < V4.14.00.26068 on Windows
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T22:32:09.431Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-702935.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-51438",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-22T17:51:00.924153Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-22T17:57:26.766Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC1047E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC647E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC847E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish\u00ae server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20: Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T10:00:13.080Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-702935.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-51438",
        "datePublished": "2024-01-09T10:00:13.080Z",
        "dateReserved": "2023-12-19T11:46:45.583Z",
        "dateUpdated": "2025-05-22T17:57:26.766Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-22216 (GCVE-0-2024-22216)

    Vulnerability from nvd – Published: 2024-01-08 00:00 – Updated: 2025-06-18 16:54
    VLAI
    Summary
    In default installations of Microchip maxView Storage Manager (for Adaptec Smart Storage Controllers) where Redfish server is configured for remote system management, unauthorized access can occur, with data modification and information disclosure. This affects 3.00.23484 through 4.14.00.26064 (except for the patched versions 3.07.23980 and 4.07.00.25339).
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-284 - Improper Access Control
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T22:35:34.882Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.microchip.com/en-us/solutions/embedded-security/how-to-report-potential-product-security-vulnerabilities/maxview-storage-manager-redfish-server-vulnerability"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-22216",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-08T14:16:33.392817Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-284",
                    "description": "CWE-284 Improper Access Control",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-18T16:54:35.287Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In default installations of Microchip maxView Storage Manager (for Adaptec Smart Storage Controllers) where Redfish server is configured for remote system management, unauthorized access can occur, with data modification and information disclosure. This affects 3.00.23484 through 4.14.00.26064 (except for the patched versions 3.07.23980 and 4.07.00.25339)."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-08T06:37:22.420Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.microchip.com/en-us/solutions/embedded-security/how-to-report-potential-product-security-vulnerabilities/maxview-storage-manager-redfish-server-vulnerability"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-22216",
        "datePublished": "2024-01-08T00:00:00.000Z",
        "dateReserved": "2024-01-08T00:00:00.000Z",
        "dateUpdated": "2025-06-18T16:54:35.287Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-23588 (GCVE-0-2023-23588)

    Vulnerability from nvd – Published: 2023-04-11 09:03 – Updated: 2024-10-15 17:12
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager < 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application. A local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
    Assigner
    Impacted products
    Vendor Product Version
    Siemens SIMATIC IPC1047 Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC IPC1047E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
    Create a notification for this product.
    Siemens SIMATIC IPC647D Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
    Create a notification for this product.
    Siemens SIMATIC IPC847D Affected: All versions
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: All versions with maxView Storage Manager < 4.09.00.25611 on Windows
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T10:35:33.386Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-23588",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-15T17:09:07.958283Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-15T17:12:13.841Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC1047",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC1047E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC647D",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC647E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC847D",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC IPC847E",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC IPC1047 (All versions), SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC647D (All versions), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows), SIMATIC IPC847D (All versions), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c 4.09.00.25611 on Windows). The Adaptec Maxview application on affected devices is using a non-unique TLS certificate across installations to protect the communication from the local browser to the local application.\r\nA local attacker may use this key to decrypt intercepted local traffic between the browser and the application and could perform a man-in-the-middle attack in order to modify data in transit."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 6.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-200",
                  "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-11T09:03:01.130Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-511182.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2023-23588",
        "datePublished": "2023-04-11T09:03:01.130Z",
        "dateReserved": "2023-01-13T14:55:01.563Z",
        "dateUpdated": "2024-10-15T17:12:13.841Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }