All the vulnerabilites related to Siemens - SITOP Manager
cve-2019-6568
Vulnerability from cvelistv5
Published
2019-04-17 13:40
Modified
2024-08-04 20:23
Summary
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1616 Version: All versions
Siemens SIMATIC CP 343-1 Advanced Version: All versions
Siemens SIMATIC CP 443-1 Version: All versions < V3.3
Siemens SIMATIC CP 443-1 Version: All versions < V3.3
Siemens SIMATIC CP 443-1 Advanced Version: All versions < V3.3
Siemens SIMATIC CP 443-1 OPC UA Version: All versions
Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU Version: All versions < V3.2.16
Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU Version: All versions < V3.2.16
Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU Version: All versions < V3.2.16
Siemens SIMATIC ET 200S IM151-8 PN/DP CPU Version: All versions < V3.2.16
Siemens SIMATIC ET 200S IM151-8F PN/DP CPU Version: All versions < V3.2.16
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Version: All versions < V2.1.6
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V2.7
Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) Version: All versions < V15.1 Upd4
Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) Version: All versions < V15.1 Upd4
Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F Version: All versions < V15.1 Upd4
Siemens SIMATIC IPC DiagMonitor Version: All versions < V5.1.3
Siemens SIMATIC RF182C Version: All versions
Siemens SIMATIC RF185C Version: All versions < V1.1.0
Siemens SIMATIC RF186C Version: All versions < V1.1.0
Siemens SIMATIC RF188C Version: All versions < V1.1.0
Siemens SIMATIC RF600R family Version: All versions < V3.2.1
Siemens SIMATIC RFID 181EIP Version: All versions
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.6.1
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V2.7
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.16
Siemens SIMATIC S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-300 CPU 319-3 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Version: All versions < V3.2.16
Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions < V2.0 SP1 UPD1
Siemens SIMATIC Teleservice Adapter IE Advanced Version: All versions
Siemens SIMATIC Teleservice Adapter IE Basic Version: All versions
Siemens SIMATIC Teleservice Adapter IE Standard Version: All versions
Siemens SIMATIC WinAC RTX 2010 Version: All versions < V2010 SP3
Siemens SIMATIC WinAC RTX F 2010 Version: All versions < V2010 SP3
Siemens SIMATIC WinCC Runtime Advanced Version: All versions < V15.1 Upd4
Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) Version: All versions < V1.1.3
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Version: All versions < V2.1.3
Siemens SINAMICS G130 V4.6 Control Unit Version: All versions
Siemens SINAMICS G130 V4.7 Control Unit Version: All versions
Siemens SINAMICS G130 V4.7 SP1 Control Unit Version: All versions
Siemens SINAMICS G130 V4.8 Control Unit Version: All versions < V4.8 HF6
Siemens SINAMICS G130 V5.1 Control Unit Version: All versions
Siemens SINAMICS G130 V5.1 SP1 Control Unit Version: All versions < V5.1 SP1 HF4
Siemens SINAMICS G150 V4.6 Control Unit Version: All versions
Siemens SINAMICS G150 V4.7 Control Unit Version: All versions
Siemens SINAMICS G150 V4.7 SP1 Control Unit Version: All versions
Siemens SINAMICS G150 V4.8 Control Unit Version: All versions < V4.8 HF6
Siemens SINAMICS G150 V5.1 Control Unit Version: All versions
Siemens SINAMICS G150 V5.1 SP1 Control Unit Version: All versions < V5.1 SP1 HF4
Siemens SINAMICS GH150 V4.7 (Control Unit) Version: All versions
Siemens SINAMICS GH150 V4.8 (Control Unit) Version: All versions < V4.8 SP2 HF9
Siemens SINAMICS GL150 V4.7 (Control Unit) Version: All versions
Siemens SINAMICS GL150 V4.8 (Control Unit) Version: All versions < V4.8 SP2 HF9
Siemens SINAMICS GM150 V4.7 (Control Unit) Version: All versions
Siemens SINAMICS GM150 V4.8 (Control Unit) Version: All versions < V4.8 SP2 HF9
Siemens SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants) Version: All versions
Siemens SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) Version: All versions
Siemens SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants) Version: All versions
Siemens SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants) Version: All versions < V4.8 HF6
Siemens SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants) Version: All versions
Siemens SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants) Version: All versions < V5.1 SP1 HF4
Siemens SINAMICS S150 V4.6 Control Unit Version: All versions
Siemens SINAMICS S150 V4.7 Control Unit Version: All versions
Siemens SINAMICS S150 V4.7 SP1 Control Unit Version: All versions
Siemens SINAMICS S150 V4.8 Control Unit Version: All versions < V4.8 HF6
Siemens SINAMICS S150 V5.1 Control Unit Version: All versions
Siemens SINAMICS S150 V5.1 SP1 Control Unit Version: All versions < V5.1 SP1 HF4
Siemens SINAMICS S210 Version: All versions < V5.1 SP1 HF8
Siemens SINAMICS SL150 V4.7 (Control Unit) Version: All versions < V4.7 HF33
Siemens SINAMICS SL150 V4.8 (Control Unit) Version: All versions
Siemens SINAMICS SM120 V4.7 (Control Unit) Version: All versions
Siemens SINAMICS SM120 V4.8 (Control Unit) Version: All versions < V4.8 SP2 HF10
Siemens SINAMICS SM150 V4.8 (Control Unit) Version: All versions
Siemens SIPLUS ET 200S IM151-8 PN/DP CPU Version: All versions < V3.2.16
Siemens SIPLUS ET 200S IM151-8F PN/DP CPU Version: All versions < V3.2.16
Siemens SIPLUS NET CP 343-1 Advanced Version: All versions
Siemens SIPLUS NET CP 443-1 Version: All versions < V3.3
Siemens SIPLUS NET CP 443-1 Advanced Version: All versions < V3.3
Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.16
Siemens SIPLUS S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.16
Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.16
Siemens SIPLUS S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.16
Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.16
Siemens SITOP Manager Version: All versions < V1.1
Siemens SITOP PSU8600 Version: All versions < V1.5
Siemens SITOP UPS1600 (incl. SIPLUS variants) Version: All versions < V2.3
Siemens TIM 1531 IRC (incl. SIPLUS NET variants) Version: All versions < V2.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.207Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC DiagMonitor",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF182C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF185C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF186C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF188C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RFID 181EIP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0 SP1 UPD1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S210",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF33"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF10"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP Manager",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:03.049Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6568",
    "datePublished": "2019-04-17T13:40:24",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-201904-0174
Vulnerability from variot

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device.

The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. Attackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0174",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sinamics s210",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics sm120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-plcsim advanced",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1.3"
      },
      {
        "model": "simatic s7-1500s",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.1"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simocode pro v pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.3"
      },
      {
        "model": "sinamics gm150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.1"
      },
      {
        "model": "simatic cp443-1 advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sitop manager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic et 200 sp open controller cpu 1515sp pc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics g130",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "cp1604",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "sinamics s120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "sitop psu8600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.5"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic cp443-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simocode pro v eip",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.3"
      },
      {
        "model": "simatic s7-plcsim advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-400 pn\\/dp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sitop ups1600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics sm150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic rf182c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic rf600r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.1"
      },
      {
        "model": "cp1616",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic teleservice adapter ie standard",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic rf185c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "simatic rf186c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-1500t",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic s7-300",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gh150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic rf188c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic et 200 sp open controller cpu 1515sp pc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.6"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic winac rtx",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "sinamics sl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic cp443-1 opc ua",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic rf181-eip",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "tim 1531 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic s7-1500f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.1"
      },
      {
        "model": "simatic cp343-1 advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics s210",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1604",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1616",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200 sp open controller cpu 1515sp pc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200 sp open controller cpu 1515sp pc2",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf185c",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "sinamics s150",
        "version": "5.1"
      },
      {
        "model": "simatic winac rtx sp2 all",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic s7-300 cpu family all",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn/dp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130 and g150",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf182c",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp443-1 opc ua",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf188c",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf600r",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "cp1604",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "cp1616",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et sp open controller cpu 1515sp pc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "200\u003cv2.1.6"
      },
      {
        "model": "simatic hmi comfort panels 4\" 22\"",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 cpu family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6"
      },
      {
        "model": "sinamics s150",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s210",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "sinamics s210 sp1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "tim irc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1531"
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf181-eip",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf186c",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-plcsim advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie standard",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro eip",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v"
      },
      {
        "model": "simocode pro pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v"
      },
      {
        "model": "sitop manager",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop psu8600",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop ups1600",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siamtic rf185c",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp343-1 advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp443-1",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp443-1 advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et sp open controller cpu 1515sp pc2",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "200"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinamics s210",
        "version": "5.1"
      },
      {
        "model": "tim irc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15310"
      },
      {
        "model": "sitop ups1600",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sitop psu8600",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sitop manager",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics s210 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s150 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics s150 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "sinamics s120 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics s120 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "sinamics g150 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g150 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "sinamics g130 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g130 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "simocode pro pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v0"
      },
      {
        "model": "simocode pro eip",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v0"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "20100"
      },
      {
        "model": "simatic teleservice adapter ie standard",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-plcsim advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-400 pn/dp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "7"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v60"
      },
      {
        "model": "simatic s7-300 cpu",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500 cpu",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf600r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf188c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf186c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf185c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf182c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp900f mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp900 mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp700f mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp700 mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp400f mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et200 open controller cpu 1515sp pc2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et200 open controller cpu 1515sp pc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic cp opc ua",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "343-10"
      },
      {
        "model": "rfid 181-eip",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16160"
      },
      {
        "model": "cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16040"
      },
      {
        "model": "sinamics s150 sp1 hf4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s150 hf6",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics s120 sp1 hf4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s120 hf6",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g150 sp1 hf4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g150 hf6",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g130 sp1 hf4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g130 hf6",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-300 cpu",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v3.x.16"
      },
      {
        "model": "simatic et200 open controller cpu 1515sp pc",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.1.6"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "cp1604",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp400f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp700",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp700f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp900",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp900f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp443 1 opc ua",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic ipc diagmonitor",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 plcsim advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc runtime advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop manager",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf600r",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf188c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf186c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "cp1616",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf182c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf181 eip",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 pn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 pn dp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie basic",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie standard",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx 2010",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf185c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v eip",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s210",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop psu8600",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop ups1600",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "tim 1531 irc",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp343 1 advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500s",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500t",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp443 1",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp443 1 advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200 sp open controller cpu 1515sp pc",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200 sp open controller cpu 1515sp pc2",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort outdoor panels",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp343-1_advanced_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf185c_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported this vulnerability to NCCIC.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-6568",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-6568",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-12904",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-158003",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6568",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-6568",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6568",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2019-6568",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6568",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-12904",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201904-458",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158003",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device. \r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. \nAttackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6568",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-099-06",
        "trust": 2.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-480230",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-530931",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-227-04",
        "trust": 1.4
      },
      {
        "db": "BID",
        "id": "107842",
        "trust": 1.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.3150",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1204.2",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "A397CC8B-EE17-4FAF-8447-E9EE5F57DD12",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "id": "VAR-201904-0174",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      }
    ],
    "trust": 1.5998432480392157
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:25:58.024000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-480230",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
      },
      {
        "title": "SSA-530931",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
      },
      {
        "title": "Patches for multiple Siemens product denial of service vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/160237"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=91286"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-125",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-06"
      },
      {
        "trust": 2.0,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-04"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6568"
      },
      {
        "trust": 0.9,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6568"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.3150/"
      },
      {
        "trust": 0.6,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-06"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-099-06"
      },
      {
        "trust": 0.6,
        "url": "https://www.securityfocus.com/bid/107842"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-webserver-28976"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/78710"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-05T00:00:00",
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "date": "2019-05-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "date": "2019-04-17T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "BID",
        "id": "107842"
      },
      {
        "date": "2019-05-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "date": "2019-04-17T14:29:03.683000",
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "date": "2023-01-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "BID",
        "id": "107842"
      },
      {
        "date": "2019-08-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "date": "2023-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "date": "2024-11-21T04:46:42.773000",
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability related to input validation in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      }
    ],
    "trust": 0.6
  }
}

var-202203-1191
Vulnerability from variot

The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference. OPC Foundation of ua-nodeset For products from other vendors, NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202203-1191",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ua-nodeset",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "opcfoundation",
        "version": "1.05.01"
      },
      {
        "model": "simatic net pc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic net pc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic net pc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "17"
      },
      {
        "model": "simatic net pc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "telecontrol server basic",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "sitop manager",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "telecontrol server basic",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ua-nodeset",
        "scope": null,
        "trust": 0.8,
        "vendor": "opc",
        "version": null
      },
      {
        "model": "simatic net pc",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "sitop manager",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2021-45117",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2021-45117",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "id": "CVE-2021-45117",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2021-45117",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-45117",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2021-45117",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202203-1906",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-45117",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-45117"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference. OPC Foundation of ua-nodeset For products from other vendors, NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-45117"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-45117"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-45117",
        "trust": 3.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-285795",
        "trust": 2.5
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-132-08",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU92977068",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.2358",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2022051719",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1906",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-45117",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-45117"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "id": "VAR-202203-1191",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.35
  },
  "last_update_date": "2024-11-23T21:50:30.008000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/Live-Hack-CVE/CVE-2021-45117 "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-476",
        "trust": 1.0
      },
      {
        "problemtype": "NULL Pointer dereference (CWE-476) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://files.opcfoundation.org/securitybulletins/opc%20foundation%20security%20bulletin%20cve-2021-45117.pdf"
      },
      {
        "trust": 2.5,
        "url": "https://www.youtube.com/watch?v=qv-rbdcav4k"
      },
      {
        "trust": 2.5,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-285795.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92977068/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45117"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-132-08"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-opc-ua-ansic-stack-38293"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-132-08"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2022051719"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2021-45117/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.2358"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/476.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2021-45117"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-132-08"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-45117"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2021-45117"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-03-21T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-45117"
      },
      {
        "date": "2023-07-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "date": "2022-03-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      },
      {
        "date": "2022-03-21T15:15:07.927000",
        "db": "NVD",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-09-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-45117"
      },
      {
        "date": "2023-07-12T08:30:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      },
      {
        "date": "2022-05-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      },
      {
        "date": "2024-11-21T06:31:59.667000",
        "db": "NVD",
        "id": "CVE-2021-45117"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "OPC\u00a0Foundation\u00a0 of \u00a0ua-nodeset\u00a0 in products from other multiple vendors \u00a0NULL\u00a0 Pointer dereference vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-018979"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "code problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202203-1906"
      }
    ],
    "trust": 0.6
  }
}