All the vulnerabilites related to Siemens - SIMATIC CP 1616
cve-2017-2680
Vulnerability from cvelistv5
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | x_refsource_CONFIRM | |
https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_CONFIRM | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-546832.html |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2017-2680", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T13:26:04.237652Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T13:26:15.327Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T14:02:07.270Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch04" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1 Patch03" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0 Patch01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 12\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 15\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 19\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 22\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "IE/AS-i Link PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "IE/PB-Link (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.03" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.10.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542SP-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE US", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF650R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF680R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF685R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 HF26" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.7: All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP5 HF7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF31" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.0 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF30" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.4 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.5 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.01" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS ACT 3SU1 interface module PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Motor Starter M200D PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600 PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.0" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.2.0" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:18.492Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-2680", "datePublished": "2017-05-11T01:00:00", "dateReserved": "2016-12-01T00:00:00", "dateUpdated": "2024-09-10T09:33:18.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-37194
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:34.104Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1604_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1616_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1623_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1626_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1628_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37194", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-19T14:23:50.733459Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-19T14:27:20.089Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1628", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:22.914Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-37194", "datePublished": "2023-10-10T10:21:22.914Z", "dateReserved": "2023-06-28T13:43:44.254Z", "dateUpdated": "2024-09-19T14:27:20.089Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-37195
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:34.179Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-37195", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-19T14:23:19.334165Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-19T14:23:36.338Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1628", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:24.004Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-37195", "datePublished": "2023-10-10T10:21:24.004Z", "dateReserved": "2023-06-28T13:43:44.254Z", "dateUpdated": "2024-09-19T14:23:36.338Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-2681
Vulnerability from cvelistv5
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html |
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch04 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2017-2681", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-23T20:22:19.045364Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-23T20:22:26.181Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T14:02:07.386Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch04" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1 Patch03" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0 Patch01" } ] }, { "defaultStatus": "unknown", "product": "IE/AS-i Link PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "IE/PB-Link (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.03" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.10.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542SP-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF650R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF680R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF685R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.7: All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.01" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS ACT 3SU1 interface module PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Motor Starter M200D PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600 PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.0" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.2.0" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:20.658Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-2681", "datePublished": "2017-05-11T10:00:00", "dateReserved": "2016-12-01T00:00:00", "dateUpdated": "2024-09-10T09:33:20.658Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-6568
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.207Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.6" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IPC DiagMonitor", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF182C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF600R family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RFID 181EIP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-PLCSIM Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0 SP1 UPD1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF9" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.6 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V5.1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V5.1 SP1 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 SP1 HF8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2 HF10" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM150 V4.8 (Control Unit)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 343-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET CP 443-1 Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.16" } ] }, { "defaultStatus": "unknown", "product": "SITOP Manager", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "TIM 1531 IRC (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] } ], "descriptions": [ { "lang": "en", "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-09T11:51:03.049Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6568", "datePublished": "2019-04-17T13:40:24", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.207Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-28400
Vulnerability from cvelistv5
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "status": "affected", "version": "0" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p", "vendor": "siemens", "versions": [ { "lessThan": "v4.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ruggedcom_rm1224", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m804pb", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_a", "vendor": "seimens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816_1_adsl_router_annex_a", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816-1_adsl-router_annex_b", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m826-2_shdsl-router", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_2", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_3", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_evdo", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_rok", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_eu", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_nam", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_s615", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w700_ieee_802.11n_family", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1748_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_eec_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2ia_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x200_4p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x202_2p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_202_2p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x204_2", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2fm", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld_ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2020-28400", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-06-13T18:59:11.953107Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-24T18:07:44.485Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T16:33:59.218Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3 3G-Router (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IE/PB-LINK", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Power Line Booster PLB, Base Module", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SOFTNET-IE PNIO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:22.763Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-28400", "datePublished": "2021-07-13T11:02:49", "dateReserved": "2020-11-10T00:00:00", "dateUpdated": "2024-12-10T13:53:22.763Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202002-0449
Vulnerability from variot
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack.
The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device. Several Siemens products contain resource exhaustion vulnerabilities.Service operation interruption (DoS) It may be put into a state. Both Siemens SCALANCE X-200IRT and SCALANCE XB-200 are products of the German company Siemens. SCALANCE X-200IRT is an industrial Ethernet switch. SCALANCE XB-200 is a managed industrial Ethernet switch. The vulnerability stems from the program's failure to limit the allocation of memory resources. A remote attacker can use the vulnerability by sending a specially crafted package to cause a denial of service. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All Versions < V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All Versions < V4.6), PROFINET Driver for Controller (All Versions < V2.1), RUGGEDCOM RM1224 (All versions < V4.3), SCALANCE M-800 / S615 (All versions < V4.3), SCALANCE W700 IEEE 802.11n (All versions <= V6.0.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All Versions < V5.3), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions), SCALANCE XB-200, XC-200, XP-200, XF-200BA and XR-300WG (All Versions < V3.0), SCALANCE XM-400 switch family (All Versions < V6.0), SCALANCE XR-500 switch family (All Versions < V6.0), SIMATIC CP 1616 and CP 1604 (All Versions < V2.8), SIMATIC CP 343-1 (incl. SIPLUS NET variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variants) (All versions), SIMATIC CP 343-1 ERPC (All versions), SIMATIC CP 343-1 LEAN (incl. SIPLUS NET variants) (All versions), SIMATIC CP 443-1 (incl. SIPLUS NET variants) (All versions), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variants) (All versions), SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET200AL IM 157-1 PN (All versions), SIMATIC ET200M IM153-4 PN IO HF (incl. SIPLUS variants) (All versions), SIMATIC ET200M IM153-4 PN IO ST (incl. SIPLUS variants) (All versions), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All Versions < V4.2.0), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants) (All Versions < V4.1.0), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN Basic (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All Versions < V3.3.1), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants) (All Versions < V4.1.0), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET200pro, IM 154-3 PN HF (All versions), SIMATIC ET200pro, IM 154-4 PN HF (All versions), SIMATIC IPC Support, Package for VxWorks (All versions), SIMATIC MV400 family (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All Versions), SIMATIC RF180C (All versions), SIMATIC RF182C (All versions), SIMATIC RF600 family (All versions < V3), SINAMICS DCP (All Versions < V1.3), SOFTNET-IE PNIO (All versions)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202002-0449", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "scalance xb-200", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "3.0" }, { "model": "scalance xc-200", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "3.0" }, { "model": "scalance xp-200", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "3.0" }, { "model": "scalance xf-200ba", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "3.0" }, { "model": "scalance xr-300wg", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "3.0" }, { "model": "sinamics dcp", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "1.3" }, { "model": "ruggedcom rm1224", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.3" }, { "model": "simatic et200mp im155-5 pn hf", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.2.0" }, { "model": "simatic et200mp im155-5 pn st", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.0" }, { "model": "simatic et200sp im155-6 pn hf", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "3.3.1" }, { "model": "simatic et200sp im155-6 pn st", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1.0" }, { "model": "simatic cp 443-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et200pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "dk standard ethernet controller", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et200m im153-4 pn io st", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xm-400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0" }, { "model": "scalance xb-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr528", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0" }, { "model": "simatic et200al im 157-1 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x-300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance m-800", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "scalance x-200irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.3" }, { "model": "simatic cp 1616", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.8" }, { "model": "simatic mv440", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "profinet driver", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "scalance s615", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.3" }, { "model": "ek-ertec 200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic et200m im153-4 pn io hf", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et200ecopn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "im 154-4 pn hf", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ek-ertec 200p", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.6" }, { "model": "simatic cp 1604", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.8" }, { "model": "scalance xc-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr526", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0" }, { "model": "simatic cp 343-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et200s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic ipc support", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr524", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0" }, { "model": "simatic mv420", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf182c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic pn\\/pn coupler", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 343-1 advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf180c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xp-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 443-1 advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xr552", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0" }, { "model": "simatic cp 343-1 erpc", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic cp 443-1 opc ua", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "im 154-3 pn hf", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance x-400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0" }, { "model": "simatic cp 343-1 lean", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance w700 ieee 802.11n", "scope": "lte", "trust": 1.0, "vendor": "siemens", "version": "6.0.1" }, { "model": "simatic et200sp im155-6 pn basic", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "scalance xf-200", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "dk standard ethernet controller", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200p p", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "profinet driver", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ruggedcom rm1224", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance m-800", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance w700 ieee 802.11n", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance xc-200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic ipc support", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp lean", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "simatic rf182c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic pn/pn coupler 6es7158-3ad01-0xa0", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1616\u003c2.8" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1604\u003c2.8" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "443-1" }, { "model": "development/evaluation kits for profinet io dk standard ethernet controller", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "development/evaluation kits for profinet io ek-ertec", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200\u003c4.5" }, { "model": "development/evaluation kits for profinet io ek-ertec 200p", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "4.6" }, { "model": "profinet driver for controller", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "2.1" }, { "model": "scalance m-800/s615", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "4.3" }, { "model": "scalance w700 ieee 802.11n", "scope": "lte", "trust": 0.6, "vendor": "siemens", "version": "\u003c=6.0.1" }, { "model": "scalance switch", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x-200" }, { "model": "scalance x-200irt switch", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "5.3" }, { "model": "scalance switch", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x-300" }, { "model": "scalance xm-400 switch", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "6.0" }, { "model": "scalance xr-500 switch", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "6.0" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "simatic cp erpc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "443-1" }, { "model": "simatic cp opc ua", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "443-1" }, { "model": "simatic et200al im pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "157-1" }, { "model": "simatic et200m im153-4 pn io hf", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200m im153-4 pn io st", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200s", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200sp im155-6 pn basic", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200ecopn", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic ipc support,package for vxworks", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et200pro,im pn hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "154-3" }, { "model": "simatic et200pro,im pn hf", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "154-4" }, { "model": "simatic mv400", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf180c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf600", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "scalance xp 200", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "scalance xb 200", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "scalance xr 300wg", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "scalance xc 200", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "dk standard ethernet controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "profinet driver", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic ipc support", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x 200irt", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x 200irt pro", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x 300", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xr 300", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xf 200ba", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x 400", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xm 400", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xr524", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xr526", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xr528", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xr552", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1616", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1604", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200p", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 erpc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 lean", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1 advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1 opc ua", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200al im 157 1 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200m im153 4 pn io hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200m im153 4 pn io st", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ruggedcom rm1224", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200mp im155 5 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200mp im155 5 pn st", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200sp im155 6 pn basic", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200sp im155 6 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200sp im155 6 pn st", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200ecopn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et200pro", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "im 154 3 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "im 154 4 pn hf", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance m 800", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic mv440", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic mv420", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic pn pn coupler", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf180c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf182c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf600", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance s615", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance w700 ieee 802 11n", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xf 200", "version": "*" } ], "sources": [ { "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "db": "CNVD", "id": "CNVD-2020-23039" }, { "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "db": "NVD", "id": "CVE-2019-13946" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:dk_standard_ethernet_controller_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ek-ertec_200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ek-ertec_200p_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:profinet_driver", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ruggedcom_rm1224_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_m-800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_s615_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_w700_ieee_802.11n_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_xc-200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/a:siemens:simatic_ipc_support", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-014603" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Yuval Ardon and Matan Dobrushin of OTORIO reported this vulnerability to CISA and Siemens.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202002-455" } ], "trust": 0.6 }, "cve": "CVE-2019-13946", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-13946", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 1.1, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.8, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-014603", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2020-23039", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-13946", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2019-014603", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-13946", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2019-13946", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2019-014603", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2020-23039", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202002-455", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9", "trust": 0.2, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2019-13946", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "db": "CNVD", "id": "CNVD-2020-23039" }, { "db": "VULMON", "id": "CVE-2019-13946" }, { "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "db": "CNNVD", "id": "CNNVD-202002-455" }, { "db": "NVD", "id": "CVE-2019-13946" }, { "db": "NVD", "id": "CVE-2019-13946" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface. \nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack. \n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device. Several Siemens products contain resource exhaustion vulnerabilities.Service operation interruption (DoS) It may be put into a state. Both Siemens SCALANCE X-200IRT and SCALANCE XB-200 are products of the German company Siemens. SCALANCE X-200IRT is an industrial Ethernet switch. SCALANCE XB-200 is a managed industrial Ethernet switch. The vulnerability stems from the program\u0027s failure to limit the allocation of memory resources. A remote attacker can use the vulnerability by sending a specially crafted package to cause a denial of service. A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All Versions \u003c V4.5), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All Versions \u003c V4.6), PROFINET Driver for Controller (All Versions \u003c V2.1), RUGGEDCOM RM1224 (All versions \u003c V4.3), SCALANCE M-800 / S615 (All versions \u003c V4.3), SCALANCE W700 IEEE 802.11n (All versions \u003c= V6.0.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.3), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions), SCALANCE XB-200, XC-200, XP-200, XF-200BA and XR-300WG (All Versions \u003c V3.0), SCALANCE XM-400 switch family (All Versions \u003c V6.0), SCALANCE XR-500 switch family (All Versions \u003c V6.0), SIMATIC CP 1616 and CP 1604 (All Versions \u003c V2.8), SIMATIC CP 343-1 (incl. SIPLUS NET variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS NET variants) (All versions), SIMATIC CP 343-1 ERPC (All versions), SIMATIC CP 343-1 LEAN (incl. SIPLUS NET variants) (All versions), SIMATIC CP 443-1 (incl. SIPLUS NET variants) (All versions), SIMATIC CP 443-1 Advanced (incl. SIPLUS NET variants) (All versions), SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET200AL IM 157-1 PN (All versions), SIMATIC ET200M IM153-4 PN IO HF (incl. SIPLUS variants) (All versions), SIMATIC ET200M IM153-4 PN IO ST (incl. SIPLUS variants) (All versions), SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants) (All Versions \u003c V4.2.0), SIMATIC ET200MP IM155-5 PN ST (incl. SIPLUS variants) (All Versions \u003c V4.1.0), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN Basic (incl. SIPLUS variants) (All versions), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants) (All Versions \u003c V3.3.1), SIMATIC ET200SP IM155-6 PN ST (incl. SIPLUS variants) (All Versions \u003c V4.1.0), SIMATIC ET200ecoPN (except 6ES7148-6JD00-0AB0 and 6ES7146-6FF00-0AB0) (All versions), SIMATIC ET200pro, IM 154-3 PN HF (All versions), SIMATIC ET200pro, IM 154-4 PN HF (All versions), SIMATIC IPC Support, Package for VxWorks (All versions), SIMATIC MV400 family (All versions), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All Versions), SIMATIC RF180C (All versions), SIMATIC RF182C (All versions), SIMATIC RF600 family (All versions \u003c V3), SINAMICS DCP (All Versions \u003c V1.3), SOFTNET-IE PNIO (All versions)", "sources": [ { "db": "NVD", "id": "CVE-2019-13946" }, { "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "db": "CNVD", "id": "CNVD-2020-23039" }, { "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "db": "VULMON", "id": "CVE-2019-13946" } ], "trust": 2.43 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-13946", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-780073", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-20-042-04", "trust": 1.5 }, { "db": "ICS CERT", "id": "ICSA-20-042-05", "trust": 1.2 }, { "db": "CNVD", "id": "CNVD-2020-23039", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202002-455", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-014603", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-20-042-08", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-20-042-07", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-20-042-03", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-20-042-09", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-20-042-02", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-20-042-06", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-20-042-01", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-20-042-10", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.0486", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.0486.2", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2020.0486.3", "trust": 0.6 }, { "db": "IVD", "id": "1044E3A5-DC26-4D11-BF22-4B3EB64F5CC9", "trust": 0.2 }, { "db": "VULMON", "id": "CVE-2019-13946", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "db": "CNVD", "id": "CNVD-2020-23039" }, { "db": "VULMON", "id": "CVE-2019-13946" }, { "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "db": "CNNVD", "id": "CNNVD-202002-455" }, { "db": "NVD", "id": "CVE-2019-13946" } ] }, "id": "VAR-202002-0449", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "db": "CNVD", "id": "CNVD-2020-23039" } ], "trust": 1.578657311794872 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "db": "CNVD", "id": "CNVD-2020-23039" } ] }, "last_update_date": "2024-11-23T21:20:13.631000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-780073", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf" }, { "title": "Patch for Multiple Siemens product resource management error vulnerabilities", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/214023" }, { "title": "Multiple Siemens Product resource management error vulnerability fixes", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=108751" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=8b423421a5be04457be73209a34b15cb" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-23039" }, { "db": "VULMON", "id": "CVE-2019-13946" }, { "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "db": "CNNVD", "id": "CNNVD-202002-455" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "db": "NVD", "id": "CVE-2019-13946" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.1, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-04" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13946" }, { "trust": 1.2, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-05" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-13946" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-09" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-08" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-06" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-03" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-02" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-01" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.0486/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.0486.2/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.0486.3/" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-042-04" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/400.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-042-04" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-23039" }, { "db": "VULMON", "id": "CVE-2019-13946" }, { "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "db": "CNNVD", "id": "CNNVD-202002-455" }, { "db": "NVD", "id": "CVE-2019-13946" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "db": "CNVD", "id": "CNVD-2020-23039" }, { "db": "VULMON", "id": "CVE-2019-13946" }, { "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "db": "CNNVD", "id": "CNNVD-202002-455" }, { "db": "NVD", "id": "CVE-2019-13946" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-02-11T00:00:00", "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "date": "2020-04-16T00:00:00", "db": "CNVD", "id": "CNVD-2020-23039" }, { "date": "2020-02-11T00:00:00", "db": "VULMON", "id": "CVE-2019-13946" }, { "date": "2020-03-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "date": "2020-02-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202002-455" }, { "date": "2020-02-11T16:15:15.023000", "db": "NVD", "id": "CVE-2019-13946" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-16T00:00:00", "db": "CNVD", "id": "CNVD-2020-23039" }, { "date": "2022-04-12T00:00:00", "db": "VULMON", "id": "CVE-2019-13946" }, { "date": "2020-03-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-014603" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202002-455" }, { "date": "2024-11-21T04:25:45.080000", "db": "NVD", "id": "CVE-2019-13946" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202002-455" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource exhaustion vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-014603" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource management error", "sources": [ { "db": "IVD", "id": "1044e3a5-dc26-4d11-bf22-4b3eb64f5cc9" }, { "db": "CNNVD", "id": "CNNVD-202002-455" } ], "trust": 0.8 } }
var-202310-0249
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions. SIMATIC CP 1604 firmware, SIMATIC CP 1616 firmware, simatic cp 1623 Multiple Siemens products, including firmware, contain vulnerabilities related to access control.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC CP 1623, CP 1626 and CP 1628 are PCI express cards for connecting Industrial Ethernet. SIMATIC CP 1604 and CP 1616 are PCI/PCI-104 cards for connecting field devices to PROFINET Industrial Ethernet.
Siemens SIMATIC CP devices have an improper access control vulnerability
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202310-0249", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic cp 1623", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1616", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1628", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1626", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1604", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1626", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1616", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1623", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1604", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1628", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1604" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1616" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1623" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1626" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1628" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "cve": "CVE-2023-37194", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "MULTIPLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 6.5, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 2.5, "id": "CNVD-2023-75576", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:M/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "id": "CVE-2023-37194", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "OTHER", "availabilityImpact": "High", "baseScore": 6.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2023-014725", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-37194", "trust": 1.0, "value": "MEDIUM" }, { "author": "OTHER", "id": "JVNDB-2023-014725", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2023-75576", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions. SIMATIC CP 1604 firmware, SIMATIC CP 1616 firmware, simatic cp 1623 Multiple Siemens products, including firmware, contain vulnerabilities related to access control.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC CP 1623, CP 1626 and CP 1628 are PCI express cards for connecting Industrial Ethernet. SIMATIC CP 1604 and CP 1616 are PCI/PCI-104 cards for connecting field devices to PROFINET Industrial Ethernet. \n\r\n\r\nSiemens SIMATIC CP devices have an improper access control vulnerability", "sources": [ { "db": "NVD", "id": "CVE-2023-37194" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "CNVD", "id": "CNVD-2023-75576" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37194", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-784849", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU98753493", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-285-01", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-014725", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-75576", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "id": "VAR-202310-0249", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" } ], "trust": 1.5117647 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" } ] }, "last_update_date": "2024-08-14T13:19:43.499000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Improper Access Control Vulnerability of Siemens SIMATIC CP Devices", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/466711" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-284", "trust": 1.0 }, { "problemtype": "Inappropriate access control (CWE-284) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98753493/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37194" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-01" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-784849.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-75576" }, { "date": "2023-12-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "date": "2023-10-10T11:15:11.903000", "db": "NVD", "id": "CVE-2023-37194" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-11T00:00:00", "db": "CNVD", "id": "CNVD-2023-75576" }, { "date": "2023-12-25T06:04:00", "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "date": "2023-10-16T18:28:22.733000", "db": "NVD", "id": "CVE-2023-37194" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Access control vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-014725" } ], "trust": 0.8 } }
var-201705-3220
Vulnerability from variot
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. SIMATIC CP, SIMATIC RF600, SCALANCE W700, etc. are all industrial automation products from Siemens AG. A denial of service vulnerability exists in several industrial devices from Siemens. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. Attackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. SIEMENS SIMATIC CP 343-1 Std, CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std, CP 443-1 Adv (All versions before V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions before V2.1.82), SIMATIC CP 1243-1 IRC (All versions before V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions before V2.0), SIMATIC CP 1542SP-1, CP 1542SP-1 IRC, and CP 1543SP-1 (All versions before to V1.0.15), SIMATIC CP 1543-1 (All versions before V2.1), SIMATIC RF650R, RF680R, RF685R (All versions before V3.0), SIMATIC CP 1616, CP 1604, DK-16xx PN IO (All versions before V2.7), SCALANCE X-200 (All versions before V5.2.2), SCALANCE X200 IRT (All versions before V5.4.0), SCALANCE X-300/X408 (All versions before V4.1.0), SCALANCE X414 (All versions before V3.10.2), SCALANCE XM400, XR500 (All versions before V6.1), SCALANCE W700 (All versions before V6.1), SCALANCE M-800, S615 (All versions before V04.03), Softnet PROFINET IO for PC-based Windows systems (All versions before V14 SP1), IE/PB-Link (All versions before V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions before V1.2.0), SITOP UPS1600 PROFINET (All versions before V2.2.0), SIMATIC ET 200AL (All versions before V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP (All versions before V4.0.1), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP (All versions before V4.1.0), SIMATIC PN/PN Coupler (All versions before V4.0), DK Standard Ethernet Controller (All versions before V4.1.1 Patch04), EK-ERTEC 200P PN IO (All versions before V4.4.0 Patch01), EK-ERTEC 200 PN IO (All versions before V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions before V2.3), SIMATIC S7-300 incl. F and T (All versions before V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions before V6.0.6), SIMATIC S7-400-H V6 (All versions before V6.0.7), SIMATIC S7-400 PN/DP V7 incl. F (All versions), SIMATIC S7-CPU 410 (All versions before V8.2), SIMATIC S7-1200 incl. F (All versions before V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions before V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions before V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft starter 3RW44 PN (All versions), SIRIUS Motor starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions), SINAMICS DCM (All versions before V1.4 SP1 HF5), SINAMICS DCP (All versions), SINAMICS G110M / G120(C/P/D) w. PN (All versions before V4.7 SP6 HF3), SINAMICS G130 and G150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S110 w. PN (All versions before V4.4 SP1 HF5), SINAMICS S120 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS V90 w. PN (All versions before V1.1), SIMOTION (All versions before V4.5 HF1), SINUMERIK 828D (All versions before V4.5 SP6 HF2 and V4.7 before SP6 HF8), SINUMERIK 840D sl (All versions before V4.5 SP6 HF8 and V4.7 before SP4 HF1), SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet. Siemens SIMATIC S7-200 Smart, etc. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) used in small and medium-sized automation systems. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module used to support PROFINET (a new generation of automation bus standard based on industrial Ethernet technology). SIRIUS Motor starter M200D PROFINET is a motor starter. The following products and versions are affected: Siemens Extension Unit 12\" PROFINET prior to V01.01.01; Extension Unit 15\" PROFINET prior to V01.01.01; Extension Unit 19\" PROFINET prior to V01.01.01; Extension Unit 22\" PROFINET SIMATIC CP 1242-7 GPRS V2 prior to V2.1.82; SIMATIC CP 1243-7 LTE/US prior to V2.1.82; SIMATIC CP 1243-8 prior to V2.1.82; SIMATIC CP 1626 V1.1 previous version
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3220", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic dk-16xx pn io", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic rf685r", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic rf650r", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic rf680r", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic cp 1543sp-1", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic cp 1542sp-1 irc", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic cp 1542sp-1", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "scalance xr500", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "scalance s615", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "scalance m-800", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "scalance xm400", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "scalance w700", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cp 1543-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "sinamics s110 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.4" }, { "model": "simatic rf650r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "dk standard ethernet controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.1" }, { "model": "simatic cp 1626", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "scalance x414", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.10.2" }, { "model": "scalance x200 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.4.0" }, { "model": "simatic cp 1243-1 dnp3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 1242-7 gprs", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.82" }, { "model": "sinamics gl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cp 1616", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics g150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g130", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cp 1604", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "simatic s7-1200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "extension unit 22 profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "01.01.01" }, { "model": "ek-ertec 200p pn io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "ie\\/pb-link", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic cm 1542-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sirius motor starter m200d profinet", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf680r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "sinamics s110 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4" }, { "model": "extension unit 19 profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "01.01.01" }, { "model": "simatic cp 1243-1 irc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.82" }, { "model": "sinamics dcp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.2" }, { "model": "simatic cp 1542sp-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.15" }, { "model": "simatic cp 343-1 adv", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simotion", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic teleservice adapter ie standard", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 443-1 opc-ua", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "dk standard ethernet controller", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.1.1" }, { "model": "sinumerik 840d sl", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic tdc cpu555", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.1" }, { "model": "simatic et 200al", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.2" }, { "model": "sinamics g150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g110m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics gh150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cp 1543sp-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.15" }, { "model": "scalance xr500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.1" }, { "model": "simatic et 200ecopn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ek-ertec 200 pn io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "softnet profinet io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "14" }, { "model": "scalance m-800", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.03" }, { "model": "simatic hmi multi panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "scalance s615", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.03" }, { "model": "simatic cp 443-1 adv", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.17" }, { "model": "sinamics sl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics dcp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.2" }, { "model": "simotion", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "sitop psu8600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.2.0" }, { "model": "sinumerik 840d sl", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic hmi mobile panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "scalance x200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.2" }, { "model": "simatic s7-1500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "simatic cp 343-1 std", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1.3" }, { "model": "simatic cp 1243-1 iec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics g110m", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "scalance xm400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.1" }, { "model": "sinamics sm120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "scalance x408", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.0" }, { "model": "simatic cp 343-1 lean", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1.3" }, { "model": "simatic dk-1604 pn io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sirius act 3su1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "ek-ertec 200 pn io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "simatic s7-300", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "softnet profinet io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14" }, { "model": "simatic tdc cp51m1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.8" }, { "model": "simatic dk-1616 pn io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "simatic et 200mp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0.1" }, { "model": "sinamics dcm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.4" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-200 smart", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "scalance w700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.1" }, { "model": "simatic et 200m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "extension unit 12 profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "01.01.01" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "extension unit 15 profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "01.01.01" }, { "model": "simatic s7-1500 software controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "sinamics g120\\ w. pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cp 1542sp-1 irc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.15" }, { "model": "simatic cp 443-1 std", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.17" }, { "model": "sinumerik 828d", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic s7-400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.6" }, { "model": "simatic et 200sp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.0" }, { "model": "sirius soft starter 3rw44 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic teleservice adapter ie basic", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode pro v profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0.0" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "ups1600 profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.2.0" }, { "model": "sinamics dcm", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.4" }, { "model": "simatic cp 1243-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.82" }, { "model": "ie\\/as-i link pn io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic cp 1243-8", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.82" }, { "model": "sinamics v90 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.01" }, { "model": "scalance x300", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.0" }, { "model": "simatic winac rtx", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics g130", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic rf685r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "ek-ertec 200p pn io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "sinamics s150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g120\\ w. pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cp 1243-7 lte\\/us", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.82" }, { "model": "pn\\/pn coupler", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "sinumerik 828d", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic teleservice adapter ie advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "dk standard ethernet controller", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200 pn io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200p pn io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ie/as-i link pn io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ie/pb-link", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "pn/pn coupler", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x200 irt", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x300", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x408", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x414", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cm 1542-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1243-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1543-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1604", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1616", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 adv", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 lean", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 std", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 adv", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 opc-ua", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 std", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200al", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200ecopn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200m", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200pro", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200s", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200sp", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi mobile panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi multi panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-200 smart", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-300", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-400", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie basic", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter standard modem", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic winac rtx 2010", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simocode pro v profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simotion", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics dcm", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics dcp", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g110m", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g120 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g130", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g150", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s110 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s150", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics v90 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinumerik 828d", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinumerik 840d sl", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sirius act 3su1 interface module profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sirius motor starter m200d profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sirius soft starter 3rw44 pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sitop psu8600", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sitop ups1600 profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "softnet profinet io", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "for pc-based windows systems firmware" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1616" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1604" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1543-1" }, { "model": "simatic cm", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1542-1" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1243-1" }, { "model": "simatic cp opc-ua", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "443-1" }, { "model": "simatic cp adv", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "443-1" }, { "model": "simatic cp std", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "443-1" }, { "model": "simatic cp std", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "simatic cp lean", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "simatic cp adv", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "343-1" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x408" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x414" }, { "model": "scalance irt", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x200" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x200" }, { "model": "scalance", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "x300" }, { "model": "simatic rf650r", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 opc-ua", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cm 1542-1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp 1542sp-1 irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 adv", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 std", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp 1543-1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp 1543sp-1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp 1542sp-1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf680r", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "sinumerik 828d", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "sinumerik 840d sl", "version": "*" }, { "model": "ups1600 profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "softnet profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sitop psu8600", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sirius soft starter 3rw44 pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sirius act 3su1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 840d", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 828d", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics sm150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics sm120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7.5" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7.4" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics gl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simotion", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "20100" }, { "model": "simatic teleservice adapter standard modem", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-400", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-300", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-200 smart", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf685r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf680r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf650r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2000" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "343-10" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16260" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16160" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16040" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1543-12.0.28" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1543-10" }, { "model": "simatic cp 1542sp-1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic cp irc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1243-80" }, { "model": "simatic cp lte eu/us", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1243-70" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1243-10" }, { "model": "simatic cp gprs", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1242-7v20" }, { "model": "scalance xr500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance xm400", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x4140" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x4084.0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x4083.0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x3000" }, { "model": "scalance irt", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x2000" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x2000" }, { "model": "scalance w700 series", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.4" }, { "model": "scalance w700 series", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.5.4" }, { "model": "scalance s615", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance m-800", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.02" }, { "model": "scalance m-800", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "ie/as-i link pn io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "extension unit profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "22?0" }, { "model": "extension unit profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "19?0" }, { "model": "extension unit profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15?0" }, { "model": "extension unit profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12?0" }, { "model": "e/pb-link", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 840d sl", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinumerik 828d", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics sm120 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics sl150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gm150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gl150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gh150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "simatic rf685r", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "simatic rf680r", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "simatic cp", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "16162.7" }, { "model": "simatic cp 1604d", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.7" }, { "model": "simatic cp irc", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1243-82.1.82" }, { "model": "simatic cp lte eu/us", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1243-72.1.82" }, { "model": "simatic cp gprs", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1242-7v22.1.82" }, { "model": "simatic rf650r", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "simatic cp", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "443-13.2.17" }, { "model": "simatic cp", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15431.2.1" }, { "model": "simatic cm1542", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.2" }, { "model": "scalance w700", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "6.1" }, { "model": "extension unit profinet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "22?1.1.1" }, { "model": "extension unit profinet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "19?1.1.1" }, { "model": "extension unit profinet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15?1.1.1" }, { "model": "extension unit profinet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "12?1.1.1" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 std", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1542sp 1 irc", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1543sp 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1543 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf650r", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf680r", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf685r", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1616", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1604", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic dk 16xx pn io", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x200", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 lean", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x200 irt", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x408", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x414", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xm400", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xr500", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance w700", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance m 800", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance s615", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "softnet profinet io", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 adv", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ie pb link", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ie as i link pn io", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter standard modem", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie basic modem", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie advanced modem", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop psu8600", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ups1600 profinet", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200al", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200ecopn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200m", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1 std", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200pro", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200s", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "pn pn coupler", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "dk standard ethernet controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200p pn io", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200 pn io", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 200 smart", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1 adv", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 controller", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx 2010", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sirius act 3su1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sirius soft starter 3rw44 pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sirius motor starter m200d profinet", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v profinet", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcm", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1 opc ua", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g110m", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g120 c p d w pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g130", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s110 w pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics v90 w pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simotion", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1243 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi multi panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi mobile panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cm 1542 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1542sp 1", "version": null } ], "sources": [ { "db": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4" }, { "db": "CNVD", "id": "CNVD-2017-06151" }, { "db": "BID", "id": "98369" }, { "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "db": "CNNVD", "id": "CNNVD-201705-574" }, { "db": "NVD", "id": "CVE-2017-2680" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:dk_standard_ethernet_controller_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ek-ertec_200_pn_io_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ek-ertec_200p_pn_io_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ie%2Fpb-link_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ie%2Fas-i_link_pn_io_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:pn%2Fpn_coupler_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_m-800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_s615_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_w700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x200irt_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x300_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x408_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x414_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_xm400_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_xr500_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cm_1542-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1243-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1542sp-1_irc_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1542sp-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1543-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1543sp-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_lean_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_adv_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_std_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_std_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_opc-ua_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_dk-16xx_pn_io_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200al_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200ecopn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200mp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200pro_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200sp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_mobile_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_multi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf650r_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf680r_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf685r_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_software_controller_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-200_smart_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-300_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-400_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_standard_modem_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_winac_rtx_2010_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simocode_pro_v_profinet_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simotion_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_dcm_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_dcp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_g110m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_g120%28c%2Fp%2Fd%29_w._pn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_g130_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_g150_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics__s110_w._pn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_s120_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_s150_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_v90_w._pn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinumerik_828d_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinumerik_840d_sl_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sirius_act_3su1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sirius_motor_starter_m200d_profinet_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sirius_soft_starter_3rw44_pn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sitop_psu8600_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ups1600_profinet_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:softnet_profinet_io_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-004134" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.", "sources": [ { "db": "BID", "id": "98369" } ], "trust": 0.3 }, "cve": "CVE-2017-2680", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CVE-2017-2680", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CNVD-2017-06151", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "VHN-110883", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "id": "CVE-2017-2680", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2017-2680", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-2680", "trust": 1.0, "value": "MEDIUM" }, { "author": "productcert@siemens.com", "id": "CVE-2017-2680", "trust": 1.0, "value": "High" }, { "author": "NVD", "id": "CVE-2017-2680", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2017-06151", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201705-574", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-110883", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4" }, { "db": "CNVD", "id": "CNVD-2017-06151" }, { "db": "VULHUB", "id": "VHN-110883" }, { "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "db": "CNNVD", "id": "CNNVD-201705-574" }, { "db": "NVD", "id": "CVE-2017-2680" }, { "db": "NVD", "id": "CVE-2017-2680" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. SIMATIC CP, SIMATIC RF600, SCALANCE W700, etc. are all industrial automation products from Siemens AG. A denial of service vulnerability exists in several industrial devices from Siemens. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. \nAttackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. SIEMENS SIMATIC CP 343-1 Std, CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std, CP 443-1 Adv (All versions before V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions before V2.1.82), SIMATIC CP 1243-1 IRC (All versions before V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions before V2.0), SIMATIC CP 1542SP-1, CP 1542SP-1 IRC, and CP 1543SP-1 (All versions before to V1.0.15), SIMATIC CP 1543-1 (All versions before V2.1), SIMATIC RF650R, RF680R, RF685R (All versions before V3.0), SIMATIC CP 1616, CP 1604, DK-16xx PN IO (All versions before V2.7), SCALANCE X-200 (All versions before V5.2.2), SCALANCE X200 IRT (All versions before V5.4.0), SCALANCE X-300/X408 (All versions before V4.1.0), SCALANCE X414 (All versions before V3.10.2), SCALANCE XM400, XR500 (All versions before V6.1), SCALANCE W700 (All versions before V6.1), SCALANCE M-800, S615 (All versions before V04.03), Softnet PROFINET IO for PC-based Windows systems (All versions before V14 SP1), IE/PB-Link (All versions before V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions before V1.2.0), SITOP UPS1600 PROFINET (All versions before V2.2.0), SIMATIC ET 200AL (All versions before V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP (All versions before V4.0.1), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP (All versions before V4.1.0), SIMATIC PN/PN Coupler (All versions before V4.0), DK Standard Ethernet Controller (All versions before V4.1.1 Patch04), EK-ERTEC 200P PN IO (All versions before V4.4.0 Patch01), EK-ERTEC 200 PN IO (All versions before V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions before V2.3), SIMATIC S7-300 incl. F and T (All versions before V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions before V6.0.6), SIMATIC S7-400-H V6 (All versions before V6.0.7), SIMATIC S7-400 PN/DP V7 incl. F (All versions), SIMATIC S7-CPU 410 (All versions before V8.2), SIMATIC S7-1200 incl. F (All versions before V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions before V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions before V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft starter 3RW44 PN (All versions), SIRIUS Motor starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions), SINAMICS DCM (All versions before V1.4 SP1 HF5), SINAMICS DCP (All versions), SINAMICS G110M / G120(C/P/D) w. PN (All versions before V4.7 SP6 HF3), SINAMICS G130 and G150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S110 w. PN (All versions before V4.4 SP1 HF5), SINAMICS S120 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS S150 (All versions before V4.7 HF27 and V4.8 before HF4), SINAMICS V90 w. PN (All versions before V1.1), SIMOTION (All versions before V4.5 HF1), SINUMERIK 828D (All versions before V4.5 SP6 HF2 and V4.7 before SP6 HF8), SINUMERIK 840D sl (All versions before V4.5 SP6 HF8 and V4.7 before SP4 HF1), SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (All versions) could be affected by a Denial-of-Service condition induced by a specially crafted PROFINET DCP broadcast (Layer 2 - Ethernet) packet. Siemens SIMATIC S7-200 Smart, etc. Siemens SIMATIC S7-200 Smart is a programmable logic controller (PLC) used in small and medium-sized automation systems. Siemens SIMATIC CP 343-1 Advanced is an Ethernet communication module used to support PROFINET (a new generation of automation bus standard based on industrial Ethernet technology). SIRIUS Motor starter M200D PROFINET is a motor starter. The following products and versions are affected: Siemens Extension Unit 12\\\" PROFINET prior to V01.01.01; Extension Unit 15\\\" PROFINET prior to V01.01.01; Extension Unit 19\\\" PROFINET prior to V01.01.01; Extension Unit 22\\\" PROFINET SIMATIC CP 1242-7 GPRS V2 prior to V2.1.82; SIMATIC CP 1243-7 LTE/US prior to V2.1.82; SIMATIC CP 1243-8 prior to V2.1.82; SIMATIC CP 1626 V1.1 previous version", "sources": [ { "db": "NVD", "id": "CVE-2017-2680" }, { "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "db": "CNVD", "id": "CNVD-2017-06151" }, { "db": "BID", "id": "98369" }, { "db": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4" }, { "db": "VULHUB", "id": "VHN-110883" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-2680", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-18-023-02", "trust": 2.8 }, { "db": "SIEMENS", "id": "SSA-293562", "trust": 2.6 }, { "db": "SIEMENS", "id": "SSA-284673", "trust": 2.0 }, { "db": "BID", "id": "98369", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-546832", "trust": 1.7 }, { "db": "SECTRACK", "id": "1038463", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-17-129-02", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-201705-574", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2017-06151", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-18-128-01", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2017-004134", "trust": 0.8 }, { "db": "IVD", "id": "296C9514-B30D-4FA5-BCDC-9D8B2E9620C4", "trust": 0.2 }, { "db": "SEEBUG", "id": "SSVID-99023", "trust": 0.1 }, { "db": "VULHUB", "id": "VHN-110883", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4" }, { "db": "CNVD", "id": "CNVD-2017-06151" }, { "db": "VULHUB", "id": "VHN-110883" }, { "db": "BID", "id": "98369" }, { "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "db": "CNNVD", "id": "CNNVD-201705-574" }, { "db": "NVD", "id": "CVE-2017-2680" } ] }, "id": "VAR-201705-3220", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4" }, { "db": "CNVD", "id": "CNVD-2017-06151" }, { "db": "VULHUB", "id": "VHN-110883" } ], "trust": 1.5467968472 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4" }, { "db": "CNVD", "id": "CNVD-2017-06151" } ] }, "last_update_date": "2024-11-23T22:56:02.371000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-293562", "trust": 0.8, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "title": "Patch for a number of Siemens products with a denial of service vulnerability (CNVD-2017-06151)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/93364" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=70052" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-06151" }, { "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "db": "CNNVD", "id": "CNNVD-201705-574" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "CWE-20", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-110883" }, { "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "db": "NVD", "id": "CVE-2017-2680" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-023-02" }, { "trust": 2.0, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/98369" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "trust": 1.7, "url": "http://www.securitytracker.com/id/1038463" }, { "trust": 1.1, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-02" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "trust": 0.9, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2680" }, { "trust": 0.8, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-128-01" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2680" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-129-02" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-06151" }, { "db": "VULHUB", "id": "VHN-110883" }, { "db": "BID", "id": "98369" }, { "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "db": "CNNVD", "id": "CNNVD-201705-574" }, { "db": "NVD", "id": "CVE-2017-2680" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4" }, { "db": "CNVD", "id": "CNVD-2017-06151" }, { "db": "VULHUB", "id": "VHN-110883" }, { "db": "BID", "id": "98369" }, { "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "db": "CNNVD", "id": "CNNVD-201705-574" }, { "db": "NVD", "id": "CVE-2017-2680" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-05-09T00:00:00", "db": "IVD", "id": "296c9514-b30d-4fa5-bcdc-9d8b2e9620c4" }, { "date": "2017-05-09T00:00:00", "db": "CNVD", "id": "CNVD-2017-06151" }, { "date": "2017-05-11T00:00:00", "db": "VULHUB", "id": "VHN-110883" }, { "date": "2017-05-08T00:00:00", "db": "BID", "id": "98369" }, { "date": "2017-06-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "date": "2017-05-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201705-574" }, { "date": "2017-05-11T01:29:05.400000", "db": "NVD", "id": "CVE-2017-2680" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-05-09T00:00:00", "db": "CNVD", "id": "CNVD-2017-06151" }, { "date": "2020-09-29T00:00:00", "db": "VULHUB", "id": "VHN-110883" }, { "date": "2018-05-09T14:00:00", "db": "BID", "id": "98369" }, { "date": "2018-05-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-004134" }, { "date": "2022-02-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201705-574" }, { "date": "2024-11-21T03:23:57.563000", "db": "NVD", "id": "CVE-2017-2680" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201705-574" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Service disruption in products (DoS) Vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-004134" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201705-574" } ], "trust": 0.6 } }
var-201904-0174
Vulnerability from variot
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device.
The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. Attackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0174", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinamics s210", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150", "scope": "eq", "trust": 1.3, "vendor": "siemens", "version": "5.1" }, { "model": "simatic hmi comfort outdoor panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics sm120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-plcsim advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic ipc diagmonitor", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1.3" }, { "model": "simatic s7-1500s", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "sinamics gh150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic wincc runtime advanced", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode pro v pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.3" }, { "model": "sinamics gm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic s7-1500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic cp443-1 advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "sitop manager", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "sinamics sm120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic et 200 sp open controller cpu 1515sp pc2", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics g130", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "cp1604", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics s120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sitop psu8600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.5" }, { "model": "simatic hmi ktp mobile panels ktp700f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic cp443-1", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode pro v eip", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.3" }, { "model": "simatic s7-plcsim advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic s7-400 pn\\/dp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sitop ups1600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "simatic s7-1500 software controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics sm150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic rf182c", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf600r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.1" }, { "model": "cp1616", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic teleservice adapter ie standard", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic rf185c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic rf186c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic teleservice adapter ie basic", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic hmi ktp mobile panels ktp900f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-1500t", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic hmi ktp mobile panels ktp700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic hmi ktp mobile panels ktp900", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic s7-300", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gh150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic rf188c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "simatic hmi ktp mobile panels ktp400f", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "sinamics gl150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic et 200 sp open controller cpu 1515sp pc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.6" }, { "model": "sinamics g150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2" }, { "model": "sinamics s150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic winac rtx", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics sl150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.8" }, { "model": "simatic cp443-1 opc ua", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics sm150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic rf181-eip", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "tim 1531 irc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "simatic s7-1500f", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.6.1" }, { "model": "simatic cp343-1 advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics s210", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.1" }, { "model": "simatic teleservice adapter ie advanced", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 1543sp-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1604", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1616", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 adv", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200 sp open controller cpu 1515sp pc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200 sp open controller cpu 1515sp pc2", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort outdoor panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic rf185c", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.6, "vendor": "sinamics s150", "version": "5.1" }, { "model": "simatic winac rtx sp2 all", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "2010" }, { "model": "simatic s7-300 cpu family all", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7" }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics g130 and g150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf182c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic wincc runtime advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1 opc ua", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic ipc diagmonitor", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf188c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf600r", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "cp1604", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "cp1616", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et sp open controller cpu 1515sp pc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200\u003cv2.1.6" }, { "model": "simatic hmi comfort panels 4\" 22\"", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic hmi ktp mobile panels", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 cpu family", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v6" }, { "model": "sinamics s150", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s210", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "sinamics s210 sp1", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v5.1" }, { "model": "tim irc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1531" }, { "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf181-eip", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic rf186c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic s7-plcsim advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie basic", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie standard", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simocode pro eip", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v" }, { "model": "simocode pro pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v" }, { "model": "sitop manager", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sitop psu8600", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sitop ups1600", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "siamtic rf185c", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp343-1 advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic cp443-1 advanced", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "simatic et sp open controller cpu 1515sp pc2", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "200" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "sinamics s210", "version": "5.1" }, { "model": "tim irc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15310" }, { "model": "sitop ups1600", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sitop psu8600", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sitop manager", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics s210 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics s120 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s120 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics g150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g150 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "sinamics g130 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g130 sp1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g130", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.6" }, { "model": "simocode pro pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v0" }, { "model": "simocode pro eip", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v0" }, { "model": "simatic wincc runtime advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "20100" }, { "model": "simatic teleservice adapter ie standard", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic teleservice adapter ie basic", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic teleservice adapter ie advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-plcsim advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-400 pn/dp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "7" }, { "model": "simatic s7-400 pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "v60" }, { "model": "simatic s7-300 cpu", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500 software controller", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500 cpu", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf600r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf188c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf186c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf185c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf182c", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic ipc diagmonitor", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp900f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp900 mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp700f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp700 mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp400f mobile", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi ktp mobile panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic hmi comfort outdoor panels", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et200 open controller cpu 1515sp pc2", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et200 open controller cpu 1515sp pc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic cp opc ua", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp advanced", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "343-10" }, { "model": "rfid 181-eip", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16160" }, { "model": "cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16040" }, { "model": "sinamics s150 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s150 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics s120 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics s120 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g150 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g150 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics g130 sp1 hf4", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "5.1" }, { "model": "sinamics g130 hf6", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "simatic s7-300 cpu", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "v3.x.16" }, { "model": "simatic et200 open controller cpu 1515sp pc", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.1.6" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp1604", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp400f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp700f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi ktp mobile panels ktp900f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1 opc ua", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic ipc diagmonitor", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 plcsim advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic wincc runtime advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop manager", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf600r", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf188c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf186c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp1616", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf182c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf181 eip", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400 pn dp", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie basic", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie standard", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx 2010", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf185c", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v eip", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g130", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s210", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop psu8600", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop ups1600", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "tim 1531 irc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp343 1 advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500f", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500s", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500t", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp443 1 advanced", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200 sp open controller cpu 1515sp pc", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200 sp open controller cpu 1515sp pc2", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort outdoor panels", "version": "*" } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp343-1_advanced_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf185c_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-003541" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to NCCIC.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 }, "cve": "CVE-2019-6568", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CVE-2019-6568", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2019-12904", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-158003", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "id": "CVE-2019-6568", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2019-6568", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2019-6568", "trust": 1.0, "value": "HIGH" }, { "author": "productcert@siemens.com", "id": "CVE-2019-6568", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "CVE-2019-6568", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2019-12904", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201904-458", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-158003", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device. \r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. \nAttackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data", "sources": [ { "db": "NVD", "id": "CVE-2019-6568" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "BID", "id": "107842" }, { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "VULHUB", "id": "VHN-158003" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-6568", "trust": 3.6 }, { "db": "ICS CERT", "id": "ICSA-19-099-06", "trust": 2.3 }, { "db": "SIEMENS", "id": "SSA-480230", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-530931", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-19-227-04", "trust": 1.4 }, { "db": "BID", "id": "107842", "trust": 1.0 }, { "db": "CNNVD", "id": "CNNVD-201904-458", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2019-12904", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-003541", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3150", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.1204.2", "trust": 0.6 }, { "db": "IVD", "id": "A397CC8B-EE17-4FAF-8447-E9EE5F57DD12", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-158003", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "id": "VAR-201904-0174", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" } ], "trust": 1.5998432480392157 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS", "Network device" ], "sub_category": null, "trust": 0.6 }, { "category": [ "ICS" ], "sub_category": null, "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" } ] }, "last_update_date": "2024-11-23T22:25:58.024000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-480230", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "title": "SSA-530931", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" }, { "title": "Patches for multiple Siemens product denial of service vulnerabilities", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/160237" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=91286" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-125", "trust": 1.1 }, { "problemtype": "CWE-20", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-158003" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-06" }, { "trust": 2.0, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf" }, { "trust": 1.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-04" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6568" }, { "trust": 0.9, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6568" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3150/" }, { "trust": 0.6, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-06" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-099-06" }, { "trust": 0.6, "url": "https://www.securityfocus.com/bid/107842" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-webserver-28976" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/78710" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "db": "CNVD", "id": "CNVD-2019-12904" }, { "db": "VULHUB", "id": "VHN-158003" }, { "db": "BID", "id": "107842" }, { "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "db": "CNNVD", "id": "CNNVD-201904-458" }, { "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-05T00:00:00", "db": "IVD", "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12" }, { "date": "2019-05-05T00:00:00", "db": "CNVD", "id": "CNVD-2019-12904" }, { "date": "2019-04-17T00:00:00", "db": "VULHUB", "id": "VHN-158003" }, { "date": "2019-04-09T00:00:00", "db": "BID", "id": "107842" }, { "date": "2019-05-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "date": "2019-04-09T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-458" }, { "date": "2019-04-17T14:29:03.683000", "db": "NVD", "id": "CVE-2019-6568" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-05-07T00:00:00", "db": "CNVD", "id": "CNVD-2019-12904" }, { "date": "2023-01-10T00:00:00", "db": "VULHUB", "id": "VHN-158003" }, { "date": "2019-04-09T00:00:00", "db": "BID", "id": "107842" }, { "date": "2019-08-20T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-003541" }, { "date": "2023-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201904-458" }, { "date": "2024-11-21T04:46:42.773000", "db": "NVD", "id": "CVE-2019-6568" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerability related to input validation in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-003541" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201904-458" } ], "trust": 0.6 } }
var-201705-3221
Vulnerability from variot
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. SIMATIC HMI is an industrial device from Siemens AG, Germany. The SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. Attackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. A vulnerability has been identified in SIMATIC CP 343-1 Std (All versions), SIMATIC CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std (All versions < V3.2.17), SIMATIC CP 443-1 Adv (All versions < V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions < V2.1.82), SIMATIC CP 1243-1 IRC (All versions < V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions < V2.0), SIMATIC CM 1542SP-1 (All versions < V1.0.15), SIMATIC CP 1542SP-1 IRC (All versions < V1.0.15), SIMATIC CP 1543SP-1 (All versions < V1.0.15), SIMATIC CP 1543-1 (All versions < V2.1), SIMATIC RF650R (All versions < V3.0), SIMATIC RF680R (All versions < V3.0), SIMATIC RF685R (All versions < V3.0), SIMATIC CP 1616 (All versions < V2.7), SIMATIC CP 1604 (All versions < V2.7), SIMATIC DK-16xx PN IO (All versions < V2.7), SCALANCE X-200 (All versions < V5.2.2), SCALANCE X-200 IRT (All versions), SCALANCE X-300/X408 (All versions < V4.1.0), SCALANCE X414 (All versions < V3.10.2), SCALANCE XM400 (All versions < V6.1), SCALANCE XR500 (All versions < V6.1), SCALANCE W700 (All versions < V6.1), SCALANCE M-800, S615 (All versions < V4.03), Softnet PROFINET IO for PC-based Windows systems (All versions < V14 SP1), IE/PB-Link (All versions < V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions < V1.2.0), SITOP UPS1600 PROFINET (All versions < V2.2.0), SIMATIC ET 200AL (All versions < V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions < V4.0.1), SIMATIC ET 200MP IM155-5 PN ST (All versions < V4.1), SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST) (All versions), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions < V4.1.0), SIMATIC ET 200SP (except IM155-6 PN ST) (All versions), SIMATIC PN/PN Coupler (All versions < V4.0), Development/Evaluation Kit DK Standard Ethernet Controller (All versions < V4.1.1 Patch04), Development/Evaluation Kit EK-ERTEC 200P (All versions < V4.4.0 Patch01), Development/Evaluation Kit EK-ERTEC 200 (All versions < V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions < V2.3), SIMATIC S7-300 incl. F and T (All versions < V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions < V6.0.6), SIMATIC S7-400-H V6 (All versions < V6.0.7), SIMATIC S7-400 PN/DP V7 Incl. F (All versions < V7.0.2), SIMATIC S7-410 (All versions < V8.2), SIMATIC S7-1200 incl. F (All versions < V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions < V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions < V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft Starter 3RW44 PN (All versions), SIRIUS Motor Starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions < V2.0.0), SINAMICS DCM w. PN (All versions < V1.4 SP1 HF5), SINAMICS DCP w. PN (All versions < V1.2 HF 1), SINAMICS G110M w. PN (All versions < V4.7 SP6 HF3), SINAMICS G120(C/P/D) w. PN (All versions < V4.7 SP6 HF3), SINAMICS G130 V4.7 w. PN (All versions < V4.7 HF27), SINAMICS G150 V4.7 w. PN (V4.7: All versions < V4.7 HF27), SINAMICS G130 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS G150 V4.8 w. PN (All versions < V4.8 HF4), SINAMICS S110 w. PN (All versions < V4.4 SP3 HF5), SINAMICS S120 V4.7 w. PN (All versions < V4.7 HF27), and others. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Siemens SIMATIC S7-300 F, etc. Siemens SIMATIC S7-300 F is a process controller. SIMATIC HMI Comfort Panels are touch screens
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201705-3221", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinumerik 840d sl", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "4.7" }, { "model": "sinumerik 840d sl", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "4.5" }, { "model": "sinumerik 828d", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "4.7" }, { "model": "sinumerik 828d", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": "4.5" }, { "model": "simatic hmi comfort panels", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic hmi mobile panels", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "simatic rf650r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "dk standard ethernet controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.1" }, { "model": "sinamics s110 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4" }, { "model": "scalance x414", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.10.2" }, { "model": "simatic et 200sp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.0" }, { "model": "scalance x200 irt", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.4.0" }, { "model": "simatic cp 1243-1 dnp3", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 1616", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics g150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cm 1542sp-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.15" }, { "model": "sinamics g130", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cp 1604", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics s110 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.4" }, { "model": "simatic s7-1200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "ek-ertec 200p pn io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "ie\\/pb-link", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic cm 1542-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "sirius motor starter m200d profinet", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik 840d sl", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic rf680r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic cp 1243-1 irc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.82" }, { "model": "sinamics dcp", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.2" }, { "model": "simotion", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic cp 343-1 adv", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic cp 443-1 opc-ua", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200s", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "dk standard ethernet controller", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.1.1" }, { "model": "simatic teleservice adapter ie advanced modem", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic tdc cpu555", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.1" }, { "model": "simatic et 200al", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.2" }, { "model": "simatic dk-16xx pn io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.7" }, { "model": "sinamics g150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics g110m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic s7-300", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.3.17" }, { "model": "simatic cp 1543sp-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.15" }, { "model": "scalance xr500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.1" }, { "model": "simatic et 200ecopn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "ek-ertec 200 pn io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "softnet profinet io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "14" }, { "model": "scalance m-800", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.03" }, { "model": "simatic hmi multi panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "scalance s615", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.03" }, { "model": "simatic cp 443-1 adv", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.17" }, { "model": "sinamics dcp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.2" }, { "model": "simatic teleservice adapter ie basic modem", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simotion", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "sitop psu8600", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.2.0" }, { "model": "sinumerik 840d sl", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "simatic hmi mobile panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "scalance x200", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "5.2.2" }, { "model": "simatic s7-1500", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "simatic cp 343-1 std", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1.3" }, { "model": "simatic cp 1243-1 iec", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic et 200pro", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinamics g110m", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "scalance xm400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.1" }, { "model": "scalance x408", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.0" }, { "model": "simatic cp 343-1 lean", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1.3" }, { "model": "sirius act 3su1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.0" }, { "model": "ek-ertec 200 pn io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.2.1" }, { "model": "simatic tdc cp51m1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.1.8" }, { "model": "softnet profinet io", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "14" }, { "model": "simatic et 200mp", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0.1" }, { "model": "sinamics dcm", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.4" }, { "model": "simatic s7-200 smart", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.3" }, { "model": "simatic cp 1543-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.15" }, { "model": "scalance w700", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.1" }, { "model": "simatic et 200m", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "sinumerik 828d", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "simatic cp 1543sp-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "sinamics s150", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic cp 1542sp-1 irc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.0.15" }, { "model": "simatic cp 443-1 std", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.2.17" }, { "model": "simatic s7-400", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "6.0.6" }, { "model": "sirius soft starter 3rw44 pn", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simocode pro v profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0.0" }, { "model": "simatic hmi comfort panels", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "ups1600 profinet", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.2.0" }, { "model": "sinamics dcm", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.4" }, { "model": "simatic cp 1243-1", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1.82" }, { "model": "ie\\/as-i link pn io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "simatic s7-1500 software controller", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.1" }, { "model": "sinamics v90 pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.01" }, { "model": "scalance x300", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.1.0" }, { "model": "simatic winac rtx", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2010" }, { "model": "sinamics g130", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics s120", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic rf685r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "ek-ertec 200p pn io", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "4.4.0" }, { "model": "sinamics s150", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "simatic teleservice adapter standard modem", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "pn\\/pn coupler", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "sinumerik 828d", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.5" }, { "model": "sinamics g120\\ pn", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.7" }, { "model": "dk standard ethernet controller", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200 pn io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ek-ertec 200p pn io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ie/as-i link pn io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "ie/pb-link", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "pn/pn coupler", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance m-800", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance s615", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance w700", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x200 irt", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x300", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x408", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance x414", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance xm400", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "scalance xr500", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cm 1542-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1243-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1542sp-1 irc", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1542sp-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1543-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1543sp-1", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1604", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 1616", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 adv", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 lean", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 343-1 std", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 adv", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 opc-ua", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic cp 443-1 std", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic dk-16xx pn io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200al", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200ecopn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200m", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200mp", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200pro", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200s", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic et 200sp", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic hmi multi panels", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic rf650r", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic rf680r", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic rf685r", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500 software controller", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-1500", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-200 smart", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-300", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic s7-400", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie advanced", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter ie basic", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic teleservice adapter standard modem", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simatic winac rtx 2010", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simocode pro v profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "simotion", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics dcm", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics dcp", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g110m", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g120 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g130", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics g150", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s110 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics s150", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinamics v90 w. pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinumerik 828d", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sinumerik 840d sl", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sirius act 3su1 interface module profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sirius motor starter m200d profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sirius soft starter 3rw44 pn", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sitop psu8600", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "sitop ups1600 profinet", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "softnet profinet io", "scope": "eq", "trust": 0.8, "vendor": "siemens", "version": "for pc-based windows systems firmware" }, { "model": "simatic hmi multi panels", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics g150", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi mobile panels", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s120", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "4.8" }, { "model": "simatic hmi comfort panels", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinamics s110 w. pn", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": null }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "sinumerik 828d", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.4, "vendor": "sinumerik 840d sl", "version": "*" }, { "model": "ups1600 profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "softnet profinet io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sitop psu8600", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sirius soft starter 3rw44 pn", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sirius act 3su1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 840d", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 828d", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinamics sm150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics sm120", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7.5" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7.4" }, { "model": "sinamics sl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics gm150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics gl150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics gh150", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simotion", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic winac rtx", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "20100" }, { "model": "simatic teleservice adapter standard modem", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-400", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-300", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-200 smart", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic s7-1500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf685r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf680r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic rf650r", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic et", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "2000" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "443-10" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "343-10" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16260" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16160" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "16040" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1543-12.0.28" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1543-10" }, { "model": "simatic cp 1542sp-1", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "simatic cp irc", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1243-80" }, { "model": "simatic cp lte eu/us", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1243-70" }, { "model": "simatic cp", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1243-10" }, { "model": "simatic cp gprs", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "1242-7v20" }, { "model": "scalance xr500", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance xm400", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x4140" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x4084.0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x4083.0" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x3000" }, { "model": "scalance irt", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x2000" }, { "model": "scalance", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "x2000" }, { "model": "scalance w700 series", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.4" }, { "model": "scalance w700 series", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.5.4" }, { "model": "scalance s615", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "scalance m-800", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "4.02" }, { "model": "scalance m-800", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "ie/as-i link pn io", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "extension unit profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "22?0" }, { "model": "extension unit profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "19?0" }, { "model": "extension unit profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "15?0" }, { "model": "extension unit profinet", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "12?0" }, { "model": "e/pb-link", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "sinumerik 840d sl", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinumerik 828d", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.7" }, { "model": "sinamics sm120 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics sl150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gm150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gl150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "sinamics gh150 sp2", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "4.8" }, { "model": "simatic rf685r", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "simatic rf680r", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "simatic cp", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "16162.7" }, { "model": "simatic cp 1604d", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "2.7" }, { "model": "simatic cp irc", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1243-82.1.82" }, { "model": "simatic cp lte eu/us", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1243-72.1.82" }, { "model": "simatic cp gprs", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1242-7v22.1.82" }, { "model": "simatic rf650r", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "3.0" }, { "model": "simatic cp", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "443-13.2.17" }, { "model": "simatic cp", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15431.2.1" }, { "model": "simatic cm1542", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.2" }, { "model": "scalance w700", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "6.1" }, { "model": "extension unit profinet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "22?1.1.1" }, { "model": "extension unit profinet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "19?1.1.1" }, { "model": "extension unit profinet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "15?1.1.1" }, { "model": "extension unit profinet", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "12?1.1.1" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 std", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1542sp 1 irc", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1543sp 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1543 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf650r", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf680r", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic rf685r", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1616", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1604", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic dk 16xx pn io", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x200", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 lean", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x200 irt", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x408", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance x414", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xm400", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance xr500", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance w700", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance m 800", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "scalance s615", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "softnet profinet io", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 343 1 adv", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ie pb link", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ie as i link pn io", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter standard modem", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie basic modem", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic teleservice adapter ie advanced modem", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sitop psu8600", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ups1600 profinet", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200al", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200ecopn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200m", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1 std", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200mp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200pro", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200s", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic et 200sp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "pn pn coupler", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "dk standard ethernet controller", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200p pn io", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "ek ertec 200 pn io", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 200 smart", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 300", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1 adv", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 400", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1200", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic s7 1500 controller", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic winac rtx 2010", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sirius act 3su1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sirius soft starter 3rw44 pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sirius motor starter m200d profinet", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simocode pro v profinet", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcm", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 443 1 opc ua", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics dcp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g110m", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g120 c p d w pn", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g130", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics g150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s110 w pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s120", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics s150", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "sinamics v90 w pn", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simotion", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1243 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi comfort panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi multi panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic hmi mobile panels", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cm 1542 1", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "simatic cp 1542sp 1", "version": null } ], "sources": [ { "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "db": "CNVD", "id": "CNVD-2017-06153" }, { "db": "BID", "id": "98369" }, { "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "db": "CNNVD", "id": "CNNVD-201705-639" }, { "db": "NVD", "id": "CVE-2017-2681" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "cpe_match": [ { "cpe22Uri": "cpe:/o:siemens:dk_standard_ethernet_controller_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ek-ertec_200_pn_io_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ek-ertec_200p_pn_io_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ie%2Fpb-link_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ie%2Fas-i_link_pn_io_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:pn%2Fpn_coupler_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_m-800_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_s615_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_w700_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x200irt_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x300_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x408_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_x414_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_xm400_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:scalance_xr500_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cm_1542-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1243-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1542sp-1_irc_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1542sp-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1543-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1543sp-1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_lean_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_adv_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_343-1_std_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_std_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_opc-ua_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_dk-16xx_pn_io_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200al_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200ecopn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200mp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200pro_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200s_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_et_200sp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_mobile_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_hmi_multi_panels", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf650r_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf680r_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_rf685r_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1200_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_software_controller_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-200_smart_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-300_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_s7-400_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_teleservice_adapter_standard_modem_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simatic_winac_rtx_2010_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simocode_pro_v_profinet_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:simotion_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_dcm_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_dcp_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_g110m_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_g120%28c%2Fp%2Fd%29_w._pn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_g130_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_g150_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics__s110_w._pn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_s120_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_s150_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinamics_v90_w._pn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinumerik_828d_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sinumerik_840d_sl_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sirius_act_3su1_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sirius_motor_starter_m200d_profinet_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sirius_soft_starter_3rw44_pn_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:sitop_psu8600_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:ups1600_profinet_firmware", "vulnerable": true }, { "cpe22Uri": "cpe:/o:siemens:softnet_profinet_io_firmware", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-004135" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.", "sources": [ { "db": "BID", "id": "98369" } ], "trust": 0.3 }, "cve": "CVE-2017-2681", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CVE-2017-2681", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 1.8, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CNVD-2017-06153", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "33467505-7492-4ae1-b978-12f61201709a", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.2, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "VHN-110884", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "id": "CVE-2017-2681", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2017-2681", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2017-2681", "trust": 1.0, "value": "MEDIUM" }, { "author": "productcert@siemens.com", "id": "CVE-2017-2681", "trust": 1.0, "value": "High" }, { "author": "NVD", "id": "CVE-2017-2681", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2017-06153", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201705-639", "trust": 0.6, "value": "MEDIUM" }, { "author": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a", "trust": 0.2, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-110884", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "db": "CNVD", "id": "CNVD-2017-06153" }, { "db": "VULHUB", "id": "VHN-110884" }, { "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "db": "CNNVD", "id": "CNNVD-201705-639" }, { "db": "NVD", "id": "CVE-2017-2681" }, { "db": "NVD", "id": "CVE-2017-2681" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. SIMATIC HMI is an industrial device from Siemens AG, Germany. The SIMATIC HMI panels are used for operator control and monitoring of machines and equipment. Multiple Siemens Products is prone to multiple denial-of-service vulnerabilities. \nAttackers can exploit these issues to cause a denial-of-service condition. Manual restart of the server is required to resume normal operation. A vulnerability has been identified in SIMATIC CP 343-1 Std (All versions), SIMATIC CP 343-1 Lean (All versions), SIMATIC CP 343-1 Adv (All versions), SIMATIC CP 443-1 Std (All versions \u003c V3.2.17), SIMATIC CP 443-1 Adv (All versions \u003c V3.2.17), SIMATIC CP 443-1 OPC-UA (All versions), SIMATIC CP 1243-1 (All versions \u003c V2.1.82), SIMATIC CP 1243-1 IRC (All versions \u003c V2.1.82), SIMATIC CP 1243-1 IEC (All versions), SIMATIC CP 1243-1 DNP3 (All versions), SIMATIC CM 1542-1 (All versions \u003c V2.0), SIMATIC CM 1542SP-1 (All versions \u003c V1.0.15), SIMATIC CP 1542SP-1 IRC (All versions \u003c V1.0.15), SIMATIC CP 1543SP-1 (All versions \u003c V1.0.15), SIMATIC CP 1543-1 (All versions \u003c V2.1), SIMATIC RF650R (All versions \u003c V3.0), SIMATIC RF680R (All versions \u003c V3.0), SIMATIC RF685R (All versions \u003c V3.0), SIMATIC CP 1616 (All versions \u003c V2.7), SIMATIC CP 1604 (All versions \u003c V2.7), SIMATIC DK-16xx PN IO (All versions \u003c V2.7), SCALANCE X-200 (All versions \u003c V5.2.2), SCALANCE X-200 IRT (All versions), SCALANCE X-300/X408 (All versions \u003c V4.1.0), SCALANCE X414 (All versions \u003c V3.10.2), SCALANCE XM400 (All versions \u003c V6.1), SCALANCE XR500 (All versions \u003c V6.1), SCALANCE W700 (All versions \u003c V6.1), SCALANCE M-800, S615 (All versions \u003c V4.03), Softnet PROFINET IO for PC-based Windows systems (All versions \u003c V14 SP1), IE/PB-Link (All versions \u003c V3.0), IE/AS-i Link PN IO (All versions), SIMATIC Teleservice Adapter Standard Modem, IE Basic, IE Advanced (All versions), SITOP PSU8600 PROFINET (All versions \u003c V1.2.0), SITOP UPS1600 PROFINET (All versions \u003c V2.2.0), SIMATIC ET 200AL (All versions \u003c V1.0.2), SIMATIC ET 200ecoPN (All versions), SIMATIC ET 200M (All versions), SIMATIC ET 200MP IM155-5 PN BA (All versions \u003c V4.0.1), SIMATIC ET 200MP IM155-5 PN ST (All versions \u003c V4.1), SIMATIC ET 200MP (except IM155-5 PN BA and IM155-5 PN ST) (All versions), SIMATIC ET 200pro (All versions), SIMATIC ET 200S (All versions), SIMATIC ET 200SP IM155-6 PN ST (All versions \u003c V4.1.0), SIMATIC ET 200SP (except IM155-6 PN ST) (All versions), SIMATIC PN/PN Coupler (All versions \u003c V4.0), Development/Evaluation Kit DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch04), Development/Evaluation Kit EK-ERTEC 200P (All versions \u003c V4.4.0 Patch01), Development/Evaluation Kit EK-ERTEC 200 (All versions \u003c V4.2.1 Patch03), SIMATIC S7-200 SMART (All versions \u003c V2.3), SIMATIC S7-300 incl. F and T (All versions \u003c V3.X.14), SIMATIC S7-400 PN/DP V6 Incl. F (All versions \u003c V6.0.6), SIMATIC S7-400-H V6 (All versions \u003c V6.0.7), SIMATIC S7-400 PN/DP V7 Incl. F (All versions \u003c V7.0.2), SIMATIC S7-410 (All versions \u003c V8.2), SIMATIC S7-1200 incl. F (All versions \u003c V4.2.1), SIMATIC S7-1500 incl. F, T, and TF (All versions \u003c V2.1), SIMATIC S7-1500 Software Controller incl. F (All versions \u003c V2.1), SIMATIC WinAC RTX 2010 incl. F (All versions), SIRIUS ACT 3SU1 interface module PROFINET (All versions), SIRIUS Soft Starter 3RW44 PN (All versions), SIRIUS Motor Starter M200D PROFINET (All versions), SIMOCODE pro V PROFINET (All versions \u003c V2.0.0), SINAMICS DCM w. PN (All versions \u003c V1.4 SP1 HF5), SINAMICS DCP w. PN (All versions \u003c V1.2 HF 1), SINAMICS G110M w. PN (All versions \u003c V4.7 SP6 HF3), SINAMICS G120(C/P/D) w. PN (All versions \u003c V4.7 SP6 HF3), SINAMICS G130 V4.7 w. PN (All versions \u003c V4.7 HF27), SINAMICS G150 V4.7 w. PN (V4.7: All versions \u003c V4.7 HF27), SINAMICS G130 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS G150 V4.8 w. PN (All versions \u003c V4.8 HF4), SINAMICS S110 w. PN (All versions \u003c V4.4 SP3 HF5), SINAMICS S120 V4.7 w. PN (All versions \u003c V4.7 HF27), and others. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Siemens SIMATIC S7-300 F, etc. Siemens SIMATIC S7-300 F is a process controller. SIMATIC HMI Comfort Panels are touch screens", "sources": [ { "db": "NVD", "id": "CVE-2017-2681" }, { "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "db": "CNVD", "id": "CNVD-2017-06153" }, { "db": "BID", "id": "98369" }, { "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "db": "VULHUB", "id": "VHN-110884" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-2681", "trust": 3.6 }, { "db": "SIEMENS", "id": "SSA-293562", "trust": 2.6 }, { "db": "BID", "id": "98369", "trust": 2.0 }, { "db": "SECTRACK", "id": "1038463", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-17-129-02", "trust": 1.7 }, { "db": "CNVD", "id": "CNVD-2017-06153", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201705-639", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2017-004135", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-18-023-02", "trust": 0.3 }, { "db": "SIEMENS", "id": "SSA-284673", "trust": 0.3 }, { "db": "IVD", "id": "33467505-7492-4AE1-B978-12F61201709A", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-110884", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "db": "CNVD", "id": "CNVD-2017-06153" }, { "db": "VULHUB", "id": "VHN-110884" }, { "db": "BID", "id": "98369" }, { "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "db": "CNNVD", "id": "CNNVD-201705-639" }, { "db": "NVD", "id": "CVE-2017-2681" } ] }, "id": "VAR-201705-3221", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "db": "CNVD", "id": "CNVD-2017-06153" }, { "db": "VULHUB", "id": "VHN-110884" } ], "trust": 1.5075520524444446 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "db": "CNVD", "id": "CNVD-2017-06153" } ] }, "last_update_date": "2024-11-23T22:56:02.322000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-293562", "trust": 0.8, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "title": "Patch for Siemens SIMATIC HMI Denial of Service Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/93365" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=70109" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-06153" }, { "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "db": "CNNVD", "id": "CNNVD-201705-639" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "CWE-20", "trust": 0.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-110884" }, { "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "db": "NVD", "id": "CVE-2017-2681" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "trust": 1.7, "url": "http://www.securityfocus.com/bid/98369" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "trust": 1.7, "url": "http://www.securitytracker.com/id/1038463" }, { "trust": 1.1, "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-02" }, { "trust": 1.0, "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2681" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-2681" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-129-02" }, { "trust": 0.3, "url": "http://subscriber.communications.siemens.com/" }, { "trust": 0.3, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-023-02" }, { "trust": 0.3, "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2017-06153" }, { "db": "VULHUB", "id": "VHN-110884" }, { "db": "BID", "id": "98369" }, { "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "db": "CNNVD", "id": "CNNVD-201705-639" }, { "db": "NVD", "id": "CVE-2017-2681" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "db": "CNVD", "id": "CNVD-2017-06153" }, { "db": "VULHUB", "id": "VHN-110884" }, { "db": "BID", "id": "98369" }, { "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "db": "CNNVD", "id": "CNNVD-201705-639" }, { "db": "NVD", "id": "CVE-2017-2681" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-05-09T00:00:00", "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "date": "2017-05-09T00:00:00", "db": "CNVD", "id": "CNVD-2017-06153" }, { "date": "2017-05-11T00:00:00", "db": "VULHUB", "id": "VHN-110884" }, { "date": "2017-05-08T00:00:00", "db": "BID", "id": "98369" }, { "date": "2017-06-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "date": "2017-05-12T00:00:00", "db": "CNNVD", "id": "CNNVD-201705-639" }, { "date": "2017-05-11T10:29:00.180000", "db": "NVD", "id": "CVE-2017-2681" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-05-09T00:00:00", "db": "CNVD", "id": "CNVD-2017-06153" }, { "date": "2020-09-29T00:00:00", "db": "VULHUB", "id": "VHN-110884" }, { "date": "2018-05-09T14:00:00", "db": "BID", "id": "98369" }, { "date": "2017-09-11T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-004135" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201705-639" }, { "date": "2024-11-21T03:23:57.917000", "db": "NVD", "id": "CVE-2017-2681" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-201705-639" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens SIMATIC HMI Denial of service vulnerability", "sources": [ { "db": "IVD", "id": "33467505-7492-4ae1-b978-12f61201709a" }, { "db": "CNVD", "id": "CNVD-2017-06153" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201705-639" } ], "trust": 0.6 } }
var-202310-0250
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again. SIMATIC CP 1604 firmware, SIMATIC CP 1616 firmware, simatic cp 1623 Multiple Siemens products such as firmware contain a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. SIMATIC CP 1623, CP 1626 and CP 1628 are PCI express cards for connecting Industrial Ethernet. SIMATIC CP 1604 and CP 1616 are PCI/PCI-104 cards for connecting field devices to PROFINET Industrial Ethernet
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202310-0250", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic cp 1623", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1616", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1628", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1626", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1604", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1626", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1616", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1623", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1604", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1628", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1604" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1616" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1623" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1626" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1628" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75575" }, { "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "db": "NVD", "id": "CVE-2023-37195" } ] }, "cve": "CVE-2023-37195", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "MEDIUM", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 4.7, "confidentialityImpact": "NONE", "exploitabilityScore": 3.4, "id": "CNVD-2023-75575", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:L/AC:M/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 0.8, "id": "CVE-2023-37195", "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "OTHER", "availabilityImpact": "High", "baseScore": 4.4, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2023-014726", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-37195", "trust": 1.0, "value": "MEDIUM" }, { "author": "OTHER", "id": "JVNDB-2023-014726", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2023-75575", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75575" }, { "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "db": "NVD", "id": "CVE-2023-37195" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again. SIMATIC CP 1604 firmware, SIMATIC CP 1616 firmware, simatic cp 1623 Multiple Siemens products such as firmware contain a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state. SIMATIC CP 1623, CP 1626 and CP 1628 are PCI express cards for connecting Industrial Ethernet. SIMATIC CP 1604 and CP 1616 are PCI/PCI-104 cards for connecting field devices to PROFINET Industrial Ethernet", "sources": [ { "db": "NVD", "id": "CVE-2023-37195" }, { "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "db": "CNVD", "id": "CNVD-2023-75575" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37195", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-784849", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU98753493", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-285-01", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-014726", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-75575", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75575" }, { "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "db": "NVD", "id": "CVE-2023-37195" } ] }, "id": "VAR-202310-0250", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-75575" } ], "trust": 1.5117647 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75575" } ] }, "last_update_date": "2024-08-14T13:19:43.887000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens SIMATIC CP device resource consumption out of control vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchInfo/show/466716" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75575" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "Resource exhaustion (CWE-400) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "db": "NVD", "id": "CVE-2023-37195" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98753493/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37195" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-01" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-784849.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75575" }, { "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "db": "NVD", "id": "CVE-2023-37195" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-75575" }, { "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "db": "NVD", "id": "CVE-2023-37195" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-75575" }, { "date": "2023-12-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "date": "2023-10-10T11:15:11.983000", "db": "NVD", "id": "CVE-2023-37195" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-11T00:00:00", "db": "CNVD", "id": "CNVD-2023-75575" }, { "date": "2023-12-25T06:04:00", "db": "JVNDB", "id": "JVNDB-2023-014726" }, { "date": "2023-10-16T18:31:17.237000", "db": "NVD", "id": "CVE-2023-37195" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource Exhaustion Vulnerability in Multiple Siemens Products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-014726" } ], "trust": 0.8 } }