Vulnerabilites related to Accellion - File Transfer Appliance
CVE-2019-5623 (GCVE-0-2019-5623)
Vulnerability from cvelistv5
Published
2020-04-29 22:15
Modified
2024-09-16 20:48
Severity ?
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Summary
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection').
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:51.319Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "File Transfer Appliance",
          "vendor": "Accellion",
          "versions": [
            {
              "status": "affected",
              "version": "FTA_8_0_540"
            }
          ]
        }
      ],
      "datePublic": "2011-03-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-29T22:15:29",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
        }
      ],
      "title": "Accellion File Transfer Appliance Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
      "x_generator": {
        "engine": "Tod\u0027s Junk Converter 0.0.2"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2011-03-11T00:00:00.000Z",
          "ID": "CVE-2019-5623",
          "STATE": "PUBLIC",
          "TITLE": "Accellion File Transfer Appliance Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "File Transfer Appliance",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "FTA_8_0_540"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Accellion"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
          }
        ],
        "generator": {
          "engine": "Tod\u0027s Junk Converter 0.0.2"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2",
              "refsource": "MISC",
              "url": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5623",
    "datePublished": "2020-04-29T22:15:29.271646Z",
    "dateReserved": "2019-01-07T00:00:00",
    "dateUpdated": "2024-09-16T20:48:06.058Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5622 (GCVE-0-2019-5622)
Vulnerability from cvelistv5
Published
2020-04-29 22:15
Modified
2024-09-16 18:55
Severity ?
CWE
  • CWE-798 - Use of Hard-coded Credentials
Summary
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:51.539Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "File Transfer Appliance",
          "vendor": "Accellion",
          "versions": [
            {
              "status": "affected",
              "version": "FTA_8_0_540"
            }
          ]
        }
      ],
      "datePublic": "2011-03-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798: Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-29T22:15:28",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
        }
      ],
      "title": "Accellion File Transfer Appliance Use of Hard-coded Credentials",
      "x_generator": {
        "engine": "Tod\u0027s Junk Converter 0.0.2"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "",
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2011-03-11T00:00:00.000Z",
          "ID": "CVE-2019-5622",
          "STATE": "PUBLIC",
          "TITLE": "Accellion File Transfer Appliance Use of Hard-coded Credentials"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "File Transfer Appliance",
                      "version": {
                        "version_data": [
                          {
                            "platform": "",
                            "version_affected": "=",
                            "version_name": "",
                            "version_value": "FTA_8_0_540"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Accellion"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
          }
        ],
        "generator": {
          "engine": "Tod\u0027s Junk Converter 0.0.2"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798: Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2",
              "refsource": "MISC",
              "url": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5622",
    "datePublished": "2020-04-29T22:15:28.858702Z",
    "dateReserved": "2019-01-07T00:00:00",
    "dateUpdated": "2024-09-16T18:55:28.051Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-202004-0659
Vulnerability from variot

Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials. (DoS) It may be put into a state. This product supports online sharing and file synchronization using AES 128/256. The vulnerability stems from the lack of effective trust management mechanisms in network systems or products. Attackers can use the default password or hard-coded passwords, hard-coded certificates, etc. to attack the affected components

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0659",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "file transfer appliance",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "accellion",
        "version": "8_0_540"
      },
      {
        "model": "file transfer appliance",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "accellion",
        "version": "fta_8_0_540"
      },
      {
        "model": "file transfer appliance fta 8 0 540",
        "scope": null,
        "trust": 0.6,
        "vendor": "accellion",
        "version": null
      },
      {
        "model": "file transfer appliance",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "accellion",
        "version": "8 0 540"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5622"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:accellion:file_transfer_appliance",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      }
    ]
  },
  "cve": "CVE-2019-5622",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-5622",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2019-015545",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-27443",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-5622",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2019-015545",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-5622",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2019-015545",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-27443",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202004-2438",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-5622",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5622"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials. (DoS) It may be put into a state. This product supports online sharing and file synchronization using AES 128/256. The vulnerability stems from the lack of effective trust management mechanisms in network systems or products. Attackers can use the default password or hard-coded passwords, hard-coded certificates, etc. to attack the affected components",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-5622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5622"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-5622",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5622",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5622"
      }
    ]
  },
  "id": "VAR-202004-0659",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:59:21.379000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.accellion.com/"
      },
      {
        "title": "Patch for Accellion File Transfer Appliance Trust Management Issue Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/216957"
      },
      {
        "title": "Accellion File Transfer Appliance Repair measures for trust management problem vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117774"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-798",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5622"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-5622"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-5622"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/798.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-5622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5622"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5622"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5622"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "date": "2020-04-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-5622"
      },
      {
        "date": "2020-06-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "date": "2020-04-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      },
      {
        "date": "2020-04-29T23:15:13.157000",
        "db": "NVD",
        "id": "CVE-2019-5622"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "date": "2020-05-07T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-5622"
      },
      {
        "date": "2020-06-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-015545"
      },
      {
        "date": "2020-05-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      },
      {
        "date": "2024-11-21T04:45:15.403000",
        "db": "NVD",
        "id": "CVE-2019-5622"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Accellion File Transfer Appliance Trust Management Issue Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27443"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      }
    ],
    "trust": 1.2
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2438"
      }
    ],
    "trust": 0.6
  }
}

var-202004-0653
Vulnerability from variot

Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection'). (DoS) It may be put into a state. Accellion File Transfer Appliance is a file transfer device of American Accellion company. This product supports online sharing and file synchronization using AES 128/256. The vulnerability stems from the fact that the network system or product did not properly filter the special elements in the process of constructing executable commands from external input data. Attackers can use this vulnerability to execute illegal commands

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202004-0653",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "file transfer appliance",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "accellion",
        "version": "8_0_540"
      },
      {
        "model": "file transfer appliance",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "accellion",
        "version": "fta_8_0_540"
      },
      {
        "model": "file transfer appliance fta 8 0 540",
        "scope": null,
        "trust": 0.6,
        "vendor": "accellion",
        "version": null
      },
      {
        "model": "file transfer appliance",
        "scope": "eq",
        "trust": 0.1,
        "vendor": "accellion",
        "version": "8 0 540"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5623"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5623"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:accellion:file_transfer_appliance",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      }
    ]
  },
  "cve": "CVE-2019-5623",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-5623",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2019-015546",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2020-27444",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-5623",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2019-015546",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-5623",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2019-015546",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-27444",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202004-2439",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-5623",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5623"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5623"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027). (DoS) It may be put into a state. Accellion File Transfer Appliance is a file transfer device of American Accellion company. This product supports online sharing and file synchronization using AES 128/256. The vulnerability stems from the fact that the network system or product did not properly filter the special elements in the process of constructing executable commands from external input data. Attackers can use this vulnerability to execute illegal commands",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-5623"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5623"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-5623",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5623",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5623"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5623"
      }
    ]
  },
  "id": "VAR-202004-0653",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:51:27.358000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.accellion.com/"
      },
      {
        "title": "Patch for Accellion File Transfer Appliance operating system command injection vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/216963"
      },
      {
        "title": "Accellion File Transfer Appliance Fixes for operating system command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=117934"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.8
      },
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5623"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.rapid7.com/db/modules/exploit/linux/misc/accellion_fta_mpipe2"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-5623"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-5623"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/78.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-5623"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5623"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-5623"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5623"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "date": "2020-04-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-5623"
      },
      {
        "date": "2020-06-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "date": "2020-04-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      },
      {
        "date": "2020-04-29T23:15:13.220000",
        "db": "NVD",
        "id": "CVE-2019-5623"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-05-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "date": "2020-05-07T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-5623"
      },
      {
        "date": "2020-06-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-015546"
      },
      {
        "date": "2020-05-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      },
      {
        "date": "2024-11-21T04:45:15.510000",
        "db": "NVD",
        "id": "CVE-2019-5623"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Accellion File Transfer Appliance operating system command injection vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-27444"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      }
    ],
    "trust": 1.2
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202004-2439"
      }
    ],
    "trust": 0.6
  }
}