Refine your search

1 vulnerability found for FactoryTalk View Machine Edition by Rockwell Automation

CVE-2025-9064 (GCVE-0-2025-9064)
Vulnerability from nvd
Published
2025-10-14 12:22
Modified
2025-10-14 18:46
CWE
  • CWE-287 - Improper Authentication
Summary
A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9064",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T18:46:24.670147Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T18:46:34.339Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk View Machine Edition",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V15.00 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T12:22:36.551Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cp\u003e-FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\u2019s \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-Patch \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571\"\u003eBF31001\u003c/a\u003e\u0026nbsp; \u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-PanelView Plus 7 Performance Series B \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026amp;mode=3\u0026amp;refSoft=1\u0026amp;versions=61168\"\u003eV14.103\u003c/a\u003e firmware package \u0026nbsp;\u003c/p\u003e\u003c/div\u003e"
            }
          ],
          "value": "-FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\u2019s \n\n\n\n-Patch  BF31001 https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571 \u00a0 \u00a0\n\n\n\n\u00a0\n\n\n\n-PanelView Plus 7 Performance Series B  V14.103 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx  firmware package"
        }
      ],
      "source": {
        "advisory": "SD1753",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk View Machine Edition Path Traversal",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-9064",
    "datePublished": "2025-10-14T12:22:36.551Z",
    "dateReserved": "2025-08-15T13:56:26.986Z",
    "dateUpdated": "2025-10-14T18:46:34.339Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}