    VAR-202206-1629

    Vulnerability from variot - Updated: 2023-12-18 13:59

    ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202206-1629",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "control center",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "asus",
            "version": "1.4.2.5"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:asus:control_center:1.4.2.5:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          }
        ]
      },
      "cve": "CVE-2022-26668",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.4,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.4,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "VHN-417337",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULMON",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.4,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2022-26668",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "MEDIUM",
                "trust": 0.1,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "impactScore": 2.5,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "twcert@cert.org.tw",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 3.9,
                "impactScore": 3.4,
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-26668",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "twcert@cert.org.tw",
                "id": "CVE-2022-26668",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202206-2018",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-417337",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2022-26668",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417337"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26668"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          },
          {
            "db": "VULHUB",
            "id": "VHN-417337"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26668"
          }
        ],
        "trust": 1.08
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-26668",
            "trust": 1.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-417337",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26668",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417337"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26668"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ]
      },
      "id": "VAR-202206-1629",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417337"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T13:59:40.466000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "ASUS Control Center Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=198148"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-863",
            "trust": 1.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417337"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-26668/"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/863.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417337"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26668"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-417337"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26668"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26668"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-06-20T00:00:00",
            "db": "VULHUB",
            "id": "VHN-417337"
          },
          {
            "date": "2022-06-20T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-26668"
          },
          {
            "date": "2022-06-20T06:15:08.827000",
            "db": "NVD",
            "id": "CVE-2022-26668"
          },
          {
            "date": "2022-06-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-06-27T00:00:00",
            "db": "VULHUB",
            "id": "VHN-417337"
          },
          {
            "date": "2022-06-27T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-26668"
          },
          {
            "date": "2022-06-27T18:46:18.067000",
            "db": "NVD",
            "id": "CVE-2022-26668"
          },
          {
            "date": "2022-07-01T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ASUS Control Center Security hole",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2018"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202206-1464

    Vulnerability from variot - Updated: 2023-12-18 11:55

    ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data. The software can monitor and control ASUS servers and workstations

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202206-1464",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "control center",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "asus",
            "version": "1.4.2.5"
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:asus:control_center:1.4.2.5:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          }
        ]
      },
      "cve": "CVE-2022-26669",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 4.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 4.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "VHN-417338",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "VULMON",
                "availabilityImpact": "NONE",
                "baseScore": 4.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2022-26669",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "MEDIUM",
                "trust": 0.1,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "twcert@cert.org.tw",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2022-26669",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "twcert@cert.org.tw",
                "id": "CVE-2022-26669",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202206-2017",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-417338",
                "trust": 0.1,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2022-26669",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417338"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26669"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data. The software can monitor and control ASUS servers and workstations",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          },
          {
            "db": "VULHUB",
            "id": "VHN-417338"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26669"
          }
        ],
        "trust": 1.08
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2022-26669",
            "trust": 1.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017",
            "trust": 0.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-62186",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-417338",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26669",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417338"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26669"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ]
      },
      "id": "VAR-202206-1464",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417338"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T11:55:56.931000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "ASUS Control Center SQL Repair measures for injecting vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=197756"
          }
        ],
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-89",
            "trust": 1.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417338"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.8,
            "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
          },
          {
            "trust": 0.6,
            "url": "https://cxsecurity.com/cveshow/cve-2022-26669/"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/89.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-417338"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26669"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-417338"
          },
          {
            "db": "VULMON",
            "id": "CVE-2022-26669"
          },
          {
            "db": "NVD",
            "id": "CVE-2022-26669"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-06-20T00:00:00",
            "db": "VULHUB",
            "id": "VHN-417338"
          },
          {
            "date": "2022-06-20T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-26669"
          },
          {
            "date": "2022-06-20T06:15:08.903000",
            "db": "NVD",
            "id": "CVE-2022-26669"
          },
          {
            "date": "2022-06-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-06-27T00:00:00",
            "db": "VULHUB",
            "id": "VHN-417338"
          },
          {
            "date": "2022-06-27T00:00:00",
            "db": "VULMON",
            "id": "CVE-2022-26669"
          },
          {
            "date": "2022-06-27T18:45:05.067000",
            "db": "NVD",
            "id": "CVE-2022-26669"
          },
          {
            "date": "2022-07-01T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "ASUS Control Center SQL Injection vulnerability",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ],
        "trust": 0.6
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SQL injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202206-2017"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2022-26669 (GCVE-0-2022-26669)

    Vulnerability from nvd – Published: 2022-06-20 05:30 – Updated: 2024-09-17 02:42
    VLAI
    Title
    ASUS Control Center - SQL Injection
    Summary
    ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    ASUS Control Center Affected: 1.4.2.5
    Create a notification for this product.
    Date Public
    2022-04-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:11:44.296Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Control Center",
              "vendor": "ASUS",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.4.2.5"
                }
              ]
            }
          ],
          "datePublic": "2022-04-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-20T05:30:30.000Z",
            "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
            "shortName": "twcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update version to 1.4.3.2"
            }
          ],
          "source": {
            "advisory": "TVN-202203002",
            "discovery": "EXTERNAL"
          },
          "title": "ASUS Control Center - SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "AKA": "TWCERT/CC",
              "ASSIGNER": "cve@cert.org.tw",
              "DATE_PUBLIC": "2022-04-26T05:10:00.000Z",
              "ID": "CVE-2022-26669",
              "STATE": "PUBLIC",
              "TITLE": "ASUS Control Center - SQL Injection"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Control Center",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.4.2.5"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ASUS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-89 SQL Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html",
                  "refsource": "MISC",
                  "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update version to 1.4.3.2"
              }
            ],
            "source": {
              "advisory": "TVN-202203002",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "assignerShortName": "twcert",
        "cveId": "CVE-2022-26669",
        "datePublished": "2022-06-20T05:30:31.029Z",
        "dateReserved": "2022-03-08T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:42:16.801Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26668 (GCVE-0-2022-26668)

    Vulnerability from nvd – Published: 2022-06-20 05:30 – Updated: 2024-09-17 02:42
    VLAI
    Title
    ASUS Control Center - Broken Access Control
    Summary
    ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service.
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    References
    Impacted products
    Vendor Product Version
    ASUS Control Center Affected: 1.4.2.5
    Create a notification for this product.
    Date Public
    2022-04-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:11:43.535Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Control Center",
              "vendor": "ASUS",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.4.2.5"
                }
              ]
            }
          ],
          "datePublic": "2022-04-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269 Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-20T05:30:29.000Z",
            "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
            "shortName": "twcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update version to 1.4.3.2"
            }
          ],
          "source": {
            "advisory": "TVN-202203001",
            "discovery": "EXTERNAL"
          },
          "title": "ASUS Control Center - Broken Access Control",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "AKA": "TWCERT/CC",
              "ASSIGNER": "cve@cert.org.tw",
              "DATE_PUBLIC": "2022-04-26T05:10:00.000Z",
              "ID": "CVE-2022-26668",
              "STATE": "PUBLIC",
              "TITLE": "ASUS Control Center - Broken Access Control"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Control Center",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.4.2.5"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ASUS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-269 Improper Privilege Management"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html",
                  "refsource": "MISC",
                  "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update version to 1.4.3.2"
              }
            ],
            "source": {
              "advisory": "TVN-202203001",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "assignerShortName": "twcert",
        "cveId": "CVE-2022-26668",
        "datePublished": "2022-06-20T05:30:29.581Z",
        "dateReserved": "2022-03-08T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:42:54.277Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26669 (GCVE-0-2022-26669)

    Vulnerability from cvelistv5 – Published: 2022-06-20 05:30 – Updated: 2024-09-17 02:42
    VLAI
    Title
    ASUS Control Center - SQL Injection
    Summary
    ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    ASUS Control Center Affected: 1.4.2.5
    Create a notification for this product.
    Date Public
    2022-04-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:11:44.296Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Control Center",
              "vendor": "ASUS",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.4.2.5"
                }
              ]
            }
          ],
          "datePublic": "2022-04-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-20T05:30:30.000Z",
            "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
            "shortName": "twcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update version to 1.4.3.2"
            }
          ],
          "source": {
            "advisory": "TVN-202203002",
            "discovery": "EXTERNAL"
          },
          "title": "ASUS Control Center - SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "AKA": "TWCERT/CC",
              "ASSIGNER": "cve@cert.org.tw",
              "DATE_PUBLIC": "2022-04-26T05:10:00.000Z",
              "ID": "CVE-2022-26669",
              "STATE": "PUBLIC",
              "TITLE": "ASUS Control Center - SQL Injection"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Control Center",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.4.2.5"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ASUS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "ASUS Control Center is vulnerable to SQL injection. An authenticated remote attacker with general user privilege can inject SQL command to specific API parameters to acquire database schema or access data."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-89 SQL Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html",
                  "refsource": "MISC",
                  "url": "https://www.twcert.org.tw/tw/cp-132-6056-b0d90-1.html"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update version to 1.4.3.2"
              }
            ],
            "source": {
              "advisory": "TVN-202203002",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "assignerShortName": "twcert",
        "cveId": "CVE-2022-26669",
        "datePublished": "2022-06-20T05:30:31.029Z",
        "dateReserved": "2022-03-08T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:42:16.801Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-26668 (GCVE-0-2022-26668)

    Vulnerability from cvelistv5 – Published: 2022-06-20 05:30 – Updated: 2024-09-17 02:42
    VLAI
    Title
    ASUS Control Center - Broken Access Control
    Summary
    ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service.
    CWE
    • CWE-269 - Improper Privilege Management
    Assigner
    References
    Impacted products
    Vendor Product Version
    ASUS Control Center Affected: 1.4.2.5
    Create a notification for this product.
    Date Public
    2022-04-26 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T05:11:43.535Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Control Center",
              "vendor": "ASUS",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.4.2.5"
                }
              ]
            }
          ],
          "datePublic": "2022-04-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-269",
                  "description": "CWE-269 Improper Privilege Management",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-06-20T05:30:29.000Z",
            "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
            "shortName": "twcert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update version to 1.4.3.2"
            }
          ],
          "source": {
            "advisory": "TVN-202203001",
            "discovery": "EXTERNAL"
          },
          "title": "ASUS Control Center - Broken Access Control",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "AKA": "TWCERT/CC",
              "ASSIGNER": "cve@cert.org.tw",
              "DATE_PUBLIC": "2022-04-26T05:10:00.000Z",
              "ID": "CVE-2022-26668",
              "STATE": "PUBLIC",
              "TITLE": "ASUS Control Center - Broken Access Control"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Control Center",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.4.2.5"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ASUS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "ASUS Control Center API has a broken access control vulnerability. An unauthenticated remote attacker can call privileged API functions to perform partial system operations or cause partial disrupt of service."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-269 Improper Privilege Management"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html",
                  "refsource": "MISC",
                  "url": "https://www.twcert.org.tw/tw/cp-132-6055-c6500-1.html"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update version to 1.4.3.2"
              }
            ],
            "source": {
              "advisory": "TVN-202203001",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "assignerShortName": "twcert",
        "cveId": "CVE-2022-26668",
        "datePublished": "2022-06-20T05:30:29.581Z",
        "dateReserved": "2022-03-08T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:42:54.277Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }