Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    2 vulnerabilities found for CleverControl employee monitoring software by CleverControl

    CVE-2025-10548 (GCVE-0-2025-10548)

    Vulnerability from cvelistv5 – Published: 2025-09-23 06:49 – Updated: 2025-11-03 18:08
    VLAI
    Title
    Missing Certificate Validation in CleverControl Installer Allows Remote Code Execution
    Summary
    The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-295 - Improper Certificate Validation
    Assigner
    References
    Impacted products
    Credits
    Daniel Hirschberger, SEC Consult Vulnerability Lab Thorger Jansen, SEC Consult Vulnerability Lab Tobias Niemann, SEC Consult Vulnerability Lab Marius Renner, SEC Consult Vulnerability Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "LOW",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10548",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-23T19:34:25.010051Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-23T19:34:50.357Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T18:08:42.269Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Sep/71"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "CleverControl employee monitoring software",
              "vendor": "CleverControl",
              "versions": [
                {
                  "status": "affected",
                  "version": "11.5.1041.6"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Daniel Hirschberger, SEC Consult Vulnerability Lab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Thorger Jansen, SEC Consult Vulnerability Lab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Tobias Niemann, SEC Consult Vulnerability Lab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Marius Renner, SEC Consult Vulnerability Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using \u003ccode\u003ecurl.exe --insecure\u003c/code\u003e, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.\u003c/p\u003e"
                }
              ],
              "value": "The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-558",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-558 Replace Trusted Executable"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-295",
                  "description": "CWE-295 Improper Certificate Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-23T06:49:33.659Z",
            "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "shortName": "SEC-VLab"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://r.sec-consult.com/clevercontrol"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication."
                }
              ],
              "value": "The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Missing Certificate Validation in CleverControl Installer Allows Remote Code Execution",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "assignerShortName": "SEC-VLab",
        "cveId": "CVE-2025-10548",
        "datePublished": "2025-09-23T06:49:33.659Z",
        "dateReserved": "2025-09-16T11:38:55.400Z",
        "dateUpdated": "2025-11-03T18:08:42.269Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-10548 (GCVE-0-2025-10548)

    Vulnerability from nvd – Published: 2025-09-23 06:49 – Updated: 2025-11-03 18:08
    VLAI
    Title
    Missing Certificate Validation in CleverControl Installer Allows Remote Code Execution
    Summary
    The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-295 - Improper Certificate Validation
    Assigner
    References
    Impacted products
    Credits
    Daniel Hirschberger, SEC Consult Vulnerability Lab Thorger Jansen, SEC Consult Vulnerability Lab Tobias Niemann, SEC Consult Vulnerability Lab Marius Renner, SEC Consult Vulnerability Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "LOW",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-10548",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-23T19:34:25.010051Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-23T19:34:50.357Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-03T18:08:42.269Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2025/Sep/71"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "CleverControl employee monitoring software",
              "vendor": "CleverControl",
              "versions": [
                {
                  "status": "affected",
                  "version": "11.5.1041.6"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Daniel Hirschberger, SEC Consult Vulnerability Lab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Thorger Jansen, SEC Consult Vulnerability Lab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Tobias Niemann, SEC Consult Vulnerability Lab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Marius Renner, SEC Consult Vulnerability Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using \u003ccode\u003ecurl.exe --insecure\u003c/code\u003e, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.\u003c/p\u003e"
                }
              ],
              "value": "The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-558",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-558 Replace Trusted Executable"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-295",
                  "description": "CWE-295 Improper Certificate Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-23T06:49:33.659Z",
            "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "shortName": "SEC-VLab"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://r.sec-consult.com/clevercontrol"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication."
                }
              ],
              "value": "The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Missing Certificate Validation in CleverControl Installer Allows Remote Code Execution",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "assignerShortName": "SEC-VLab",
        "cveId": "CVE-2025-10548",
        "datePublished": "2025-09-23T06:49:33.659Z",
        "dateReserved": "2025-09-16T11:38:55.400Z",
        "dateUpdated": "2025-11-03T18:08:42.269Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }