Vulnerabilites related to ABB, Busch-Jaeger - BCU KNX, BA-U1.0.21
CVE-2024-4008 (GCVE-0-2024-4008)
Vulnerability from cvelistv5
Published
2024-06-05 17:15
Modified
2025-09-17 05:33
CWE
  • CWE-497 - [LLM] Exposure of Sensitive System Information to an Unauthorized Control Sphere
Summary
FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4008",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-10T11:08:58.207948Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-10T11:09:06.018Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.325Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010B0001/sd-u12-55-11-825",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "2.4! Display 55, SD/U12.55.11-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310011B0001/sd-u12-55-1-825",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "2.4! Display 55, SD/SD/U12.55.1-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010B0003/",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "2.4! Display 63, SD/U12.63.11-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310011B0003/rt-u12-86-1-825",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "RoomTouch 4\", RT/U12.86.1-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010B0004/rt-u12-86-11-825",
          "defaultStatus": "unaffected",
          "product": "RoomTouch 4\", RT/U12.86.11-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010B0006/sd-u12-70-11-4015",
          "defaultStatus": "unaffected",
          "product": "2,4\u0027\u0027 Display 70, SD/U12.70.11-4015",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310011B00004/sd-u12-70-1-4015",
          "defaultStatus": "unaffected",
          "product": "2,4\u0027\u0027 Display 70, SD-U12-70-1-4015",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010W0001/rt-u12-86-11-811",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "RoomTouch 4\", RT/U12.86.11-811",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310011W0001/rt-u12-86-1-811",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "RoomTouch 4\", RT-U12-86-1-811",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2CKA006120A0079/ba-u1-0-11",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "BCU KNX, BA-U1.0.11",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.3.0.33",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2CKA006120A0080/ba-u1-0-1",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "BCU KNX, BA-U1.0.1",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.3.0.33",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2CKA006120A0081/ba-u1-0-21",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "BCU KNX, BA-U1.0.21",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.3.0.33",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2024-06-05T16:16:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System\u0026nbsp;"
            }
          ],
          "value": "FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NO",
            "Recovery": "NOT_DEFINED",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "GREEN",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/S:N/AU:N/V:D/RE:M/U:Green",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-497",
              "description": "CWE-497 [LLM] Exposure of Sensitive System Information to an Unauthorized Control Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-17T05:33:02.694Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "FDSK Leak in KNX Secure Devices",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2024-4008",
    "datePublished": "2024-06-05T17:15:56.523Z",
    "dateReserved": "2024-04-19T17:09:06.029Z",
    "dateUpdated": "2025-09-17T05:33:02.694Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4009 (GCVE-0-2024-4009)
Vulnerability from cvelistv5
Published
2024-06-05 17:19
Modified
2025-03-27 20:31
Summary
Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4009",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-06T13:52:06.305528Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-294",
                "description": "CWE-294 Authentication Bypass by Capture-replay",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-27T20:31:09.386Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:57.233Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010B0001/sd-u12-55-11-825",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "2.4! Display 55, SD/U12.55.11-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310011B0001/sd-u12-55-1-825",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "2.4! Display 55, SD/SD/U12.55.1-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010B0003/",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "2.4! Display 63, SD/U12.63.11-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310011B0003/rt-u12-86-1-825",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "RoomTouch 4\", RT/U12.86.1-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010B0004/rt-u12-86-11-825",
          "defaultStatus": "unaffected",
          "product": "RoomTouch 4\", RT/U12.86.11-825",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010B0006/sd-u12-70-11-4015",
          "defaultStatus": "unaffected",
          "product": "2,4\u0027\u0027 Display 70, SD/U12.70.11-4015",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310011B00004/sd-u12-70-1-4015",
          "defaultStatus": "unaffected",
          "product": "2,4\u0027\u0027 Display 70, SD-U12-70-1-4015",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310010W0001/rt-u12-86-11-811",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "RoomTouch 4\", RT/U12.86.11-811",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2TMA310011W0001/rt-u12-86-1-811",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "RoomTouch 4\", RT-U12-86-1-811",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.00",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2CKA006120A0079/ba-u1-0-11",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "BCU KNX, BA-U1.0.11",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.3.0.33",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2CKA006120A0080/ba-u1-0-1",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "BCU KNX, BA-U1.0.1",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.3.0.33",
              "versionType": "custom"
            }
          ]
        },
        {
          "collectionURL": "https://new.abb.com/products/de/2CKA006120A0081/ba-u1-0-21",
          "defaultStatus": "unaffected",
          "platforms": [
            "proprietary"
          ],
          "product": "BCU KNX, BA-U1.0.21",
          "vendor": "ABB, Busch-Jaeger",
          "versions": [
            {
              "status": "affected",
              "version": "1.3.0.33",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2024-06-05T16:16:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eReplay Attack\u003c/span\u003e\n\nin ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System\u0026nbsp;\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Replay Attack\n\nin ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 9.2,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NO",
            "Recovery": "NOT_DEFINED",
            "Safety": "NEGLIGIBLE",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "GREEN",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "DIFFUSE",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H/S:N/AU:N/V:D/RE:M/U:Green",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "MODERATE"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-05T17:19:07.010Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108464A0803\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Replay Attack in KNX Secure Devices",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2024-4009",
    "datePublished": "2024-06-05T17:19:07.010Z",
    "dateReserved": "2024-04-19T17:09:27.489Z",
    "dateUpdated": "2025-03-27T20:31:09.386Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}