Vulnerabilites related to Tenda - AC5
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/1/1.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/1/1.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetSysTime function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25210", "lastModified": "2025-02-13T15:15:15.430", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:07.793", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/1/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/1/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/5/5.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/5/5.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the check_param_changed function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25213", "lastModified": "2025-02-12T22:15:29.340", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:07.907", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/5/5.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/5/5.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | f1202_firmware | 1.2.0.20\(408\) | |
tenda | f1202 | - | |
tenda | fh1202_firmware | 1.2.0.19_en | |
tenda | fh1202 | - | |
tenda | f1202_firmware | 1.0br | |
tenda | f1202 | - | |
tenda | ac10_firmware | 1.0 | |
tenda | ac10 | - | |
tenda | ac1206_firmware | 1.0 | |
tenda | ac1206 | - | |
tenda | ac7_firmware | 1.0 | |
tenda | ac7 | - | |
tenda | ac5_firmware | 1.0 | |
tenda | ac5 | - | |
tenda | ac9_firmware | 3.0 | |
tenda | ac9 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "25D11FC4-85C7-4F6C-81A2-AF9CB6BE1507", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*", "matchCriteriaId": "C36B9BA7-B171-453D-951B-23CA2F19111A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*", "matchCriteriaId": "83FA7DD8-061F-4893-ADBB-1FD1E6849107", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "54F7AF9E-E4EC-4060-B1F4-29A891970DDE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF48C35A-8042-4E7B-B672-8904B999E9AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "FD539CFA-4D45-4776-9E62-66EB123456BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "6A71BB02-CEFA-4B73-8B24-D4217C261D39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "D7D1050F-CA28-4365-8C46-6D6AF7572EAA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient." } ], "id": "CVE-2023-37717", "lastModified": "2024-11-21T08:12:10.257", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-07-14T00:15:09.477", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | f1202_firmware | 1.2.0.20\(408\) | |
tenda | f1202 | - | |
tenda | fh1202_firmware | 1.2.0.19_en | |
tenda | fh1202 | - | |
tenda | f1202_firmware | 1.0br | |
tenda | f1202 | - | |
tenda | ac10_firmware | 1.0 | |
tenda | ac10 | - | |
tenda | ac1206_firmware | 1.0 | |
tenda | ac1206 | - | |
tenda | ac7_firmware | 1.0 | |
tenda | ac7 | - | |
tenda | ac5_firmware | 1.0 | |
tenda | ac5 | - | |
tenda | ac9_firmware | 3.0 | |
tenda | ac9 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "25D11FC4-85C7-4F6C-81A2-AF9CB6BE1507", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*", "matchCriteriaId": "C36B9BA7-B171-453D-951B-23CA2F19111A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*", "matchCriteriaId": "83FA7DD8-061F-4893-ADBB-1FD1E6849107", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "54F7AF9E-E4EC-4060-B1F4-29A891970DDE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF48C35A-8042-4E7B-B672-8904B999E9AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "FD539CFA-4D45-4776-9E62-66EB123456BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "6A71BB02-CEFA-4B73-8B24-D4217C261D39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "D7D1050F-CA28-4365-8C46-6D6AF7572EAA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting." } ], "id": "CVE-2023-37716", "lastModified": "2024-11-21T08:12:10.067", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-07-14T00:15:09.430", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function." } ], "id": "CVE-2023-38935", "lastModified": "2024-11-21T08:14:28.643", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.277", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat." } ], "id": "CVE-2023-41557", "lastModified": "2024-11-21T08:21:17.497", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:14.100", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet." } ], "id": "CVE-2023-41562", "lastModified": "2024-11-21T08:21:18.267", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:14.573", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.311349 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.311349 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.591224 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.47 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.47:*:*:*:*:*:*:*", "matchCriteriaId": "2D94CA12-3FED-4730-B1B4-4F6AAA3AB17E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad clasificada como cr\u00edtica en Tenda AC5 1.0/15.03.06.47. Esta afecta la funci\u00f3n fromadvsetlanip del archivo /goform/AdvSetLanip. La manipulaci\u00f3n del argumento lanMask provoca un desbordamiento del b\u00fafer. Es posible iniciar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-5795", "lastModified": "2025-06-09T19:08:11.737", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-06T19:15:28.617", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.311349" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.311349" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.591224" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-120" } ], "source": "cna@vuldb.com", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/10/10.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/10/10.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formWifiBasicSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25217", "lastModified": "2025-02-12T21:15:11.623", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:08.053", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/10/10.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/10/10.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/3/3.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/3/3.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25215", "lastModified": "2025-02-12T21:15:11.290", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:07.980", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/3/3.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/3/3.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://ac15v10.com | Broken Link, URL Repurposed | |
cve@mitre.org | http://tenda.com | Vendor Advisory | |
cve@mitre.org | https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | http://ac15v10.com | Broken Link, URL Repurposed | |
af854a3a-2127-422b-91ae-364da2661108 | http://tenda.com | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md | Broken Link |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.20_multi | |
tenda | ac15 | 1.0 | |
tenda | ac5_firmware | 15.03.06.48_multi | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*", "matchCriteriaId": "BAF4BBA3-7C56-4383-B167-933075D5C39F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D5059CAD-BD1A-4808-BCED-006444E60701", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.48_multi:*:*:*:*:*:*:*", "matchCriteriaId": "E540AF96-2B4E-4223-B15A-8DA89D2D12F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE." }, { "lang": "es", "value": "M\u00faltiples dispositivos Tenda est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n, como AC15V1.0 Firmware versi\u00f3n V15.03.05.20_multi... AC5V1.0 Firmware versi\u00f3n V15.03.06.48_multi, etc. un atacante puede obtener informaci\u00f3n confidencial, e incluso combinarla con una inyecci\u00f3n de comandos autenticados para implementar RCE" } ], "id": "CVE-2021-44971", "lastModified": "2024-11-21T06:31:45.903", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-01-28T19:15:07.963", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link", "URL Repurposed" ], "url": "http://ac15v10.com" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://tenda.com" }, { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "URL Repurposed" ], "url": "http://ac15v10.com" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://tenda.com" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-697" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10 | 4.0 | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function." } ], "id": "CVE-2023-38937", "lastModified": "2024-11-21T08:14:28.943", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.413", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting." } ], "id": "CVE-2023-41559", "lastModified": "2024-11-21T08:21:17.803", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:14.280", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.311348 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.311348 | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?submit.591223 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0 | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.47 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.47:*:*:*:*:*:*:*", "matchCriteriaId": "2D94CA12-3FED-4730-B1B4-4F6AAA3AB17E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad clasificada como cr\u00edtica en Tenda AC5 15.03.06.47. Este problema afecta a la funci\u00f3n formSetPPTPUserList del archivo /goform/setPptpUserList. La manipulaci\u00f3n de la lista de argumentos provoca un desbordamiento del b\u00fafer. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-5794", "lastModified": "2025-06-09T19:08:21.053", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-06T19:15:28.393", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.311348" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.311348" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.591223" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-120" } ], "source": "cna@vuldb.com", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/7/7.md | Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Not Applicable | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/7/7.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Not Applicable |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the add_white_node function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25220", "lastModified": "2025-02-12T21:15:12.137", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:08.177", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/7/7.md" }, { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/7/7.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10 | 4.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function." } ], "id": "CVE-2023-38931", "lastModified": "2024-11-21T08:14:28.000", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:10.977", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://packetstormsecurity.com/files/161119/Tenda-AC5-AC1200-Wireless-Cross-Site-Scripting.html | Exploit, Third Party Advisory, VDB Entry | |
cve@mitre.org | https://www.hackingarticles.in/exploiting-stored-cross-site-scripting-at-tenda-ac5-ac1200/ | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/161119/Tenda-AC5-AC1200-Wireless-Cross-Site-Scripting.html | Exploit, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.hackingarticles.in/exploiting-stored-cross-site-scripting-at-tenda-ac5-ac1200/ | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.47 | |
tenda | ac5 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.47:*:*:*:*:*:*:*", "matchCriteriaId": "2D94CA12-3FED-4730-B1B4-4F6AAA3AB17E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A Stored Cross-site scripting (XSS) vulnerability in /main.html Wifi Settings in Tenda AC5 AC1200 version V15.03.06.47_multi allows remote attackers to inject arbitrary web script or HTML via the Wifi Name parameter." }, { "lang": "es", "value": "Una vulnerabilidad de tipo Cross-site scripting (XSS) almacenado en Wifi Settings de /main.html en Tenda AC5 AC1200 versi\u00f3n V15.03.06.47_multi, permite a atacantes remotos inyectar script web o HTML arbitrario por medio del par\u00e1metro Wifi Name" } ], "id": "CVE-2021-3186", "lastModified": "2025-07-07T17:21:17.707", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-01-26T18:16:28.147", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "VDB Entry" ], "url": "http://packetstormsecurity.com/files/161119/Tenda-AC5-AC1200-Wireless-Cross-Site-Scripting.html" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.hackingarticles.in/exploiting-stored-cross-site-scripting-at-tenda-ac5-ac1200/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "VDB Entry" ], "url": "http://packetstormsecurity.com/files/161119/Tenda-AC5-AC1200-Wireless-Cross-Site-Scripting.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.hackingarticles.in/exploiting-stored-cross-site-scripting-at-tenda-ac5-ac1200/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function." } ], "id": "CVE-2023-38930", "lastModified": "2024-11-21T08:14:27.803", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:10.907", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/4/4.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/4/4.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25214", "lastModified": "2025-02-12T21:15:11.117", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:07.940", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/4/4.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/4/4.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function." } ], "id": "CVE-2023-38933", "lastModified": "2024-11-21T08:14:28.333", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.133", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 5.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind." } ], "id": "CVE-2023-41556", "lastModified": "2024-11-21T08:21:17.330", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:13.697", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/2205794866/Tenda/blob/main/AC5/1.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/2205794866/Tenda/blob/main/AC5/1.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 V15.03.06.28 is vulnerable to Buffer Overflow via the initWebs function." } ], "id": "CVE-2023-30368", "lastModified": "2025-02-04T21:15:24.520", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-24T14:15:07.860", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC5/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC5/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo." } ], "id": "CVE-2023-41563", "lastModified": "2024-11-21T08:21:18.430", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:15.043", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/9/9.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/9/9.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25216", "lastModified": "2025-02-12T21:15:11.453", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:08.017", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/9/9.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/9/9.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/2/2.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/2/2.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25211", "lastModified": "2025-02-13T15:15:15.660", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:07.827", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/2/2.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/2/2.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/8/8.md | Third Party Advisory | |
cve@mitre.org | https://www.dlink.com/en/security-bulletin/ | Not Applicable | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/8/8.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.dlink.com/en/security-bulletin/ | Not Applicable |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25218", "lastModified": "2025-02-12T21:15:11.810", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:08.100", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/8/8.md" }, { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/8/8.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable" ], "url": "https://www.dlink.com/en/security-bulletin/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/11/11.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/11/11.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25219", "lastModified": "2025-02-12T21:15:11.973", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:08.140", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/11/11.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/11/11.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 5.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg." } ], "id": "CVE-2023-41553", "lastModified": "2024-11-21T08:21:16.867", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:13.280", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedEndTime-21d53a41781f80fb8a90f08898e8d404?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedStartTime-21d53a41781f803f97eeddd9828c5c84?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.314365 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.314365 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.603774 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.603775 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.47 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.47:*:*:*:*:*:*:*", "matchCriteriaId": "2D94CA12-3FED-4730-B1B4-4F6AAA3AB17E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC5 15.03.06.47, clasificada como cr\u00edtica. Esta vulnerabilidad afecta a una funcionalidad desconocida del archivo /goform/openSchedWifi. La manipulaci\u00f3n del argumento schedStartTime/schedEndTime provoca un desbordamiento del b\u00fafer en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-6886", "lastModified": "2025-07-01T16:47:02.973", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-30T05:15:40.763", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedEndTime-21d53a41781f80fb8a90f08898e8d404?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedStartTime-21d53a41781f803f97eeddd9828c5c84?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.314365" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.314365" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.603774" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.603775" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_time-21d53a41781f8002bdb3fe8344d6fd8c?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_timeZone-21d53a41781f8021ae2fd2ac639f1b3f?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.314366 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.314366 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.603788 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.603789 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.47 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.47:*:*:*:*:*:*:*", "matchCriteriaId": "2D94CA12-3FED-4730-B1B4-4F6AAA3AB17E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC5 15.03.06.47, clasificada como cr\u00edtica. Este problema afecta a una funcionalidad desconocida del archivo /goform/SetSysTimeCfg. La manipulaci\u00f3n del argumento time/timeZone provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-6887", "lastModified": "2025-07-01T16:42:48.927", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-30T05:15:41.103", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_time-21d53a41781f8002bdb3fe8344d6fd8c?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_timeZone-21d53a41781f8021ae2fd2ac639f1b3f?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.314366" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.314366" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.603788" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.603789" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetRebootTimer-20a53a41781f80a6b9a8f6e5915cf256?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.311622 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.311622 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.591981 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.47 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.47:*:*:*:*:*:*:*", "matchCriteriaId": "2D94CA12-3FED-4730-B1B4-4F6AAA3AB17E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC5 15.03.06.47. Se ha clasificado como cr\u00edtica. La funci\u00f3n formSetRebootTimer del archivo /goform/SetRebootTimer est\u00e1 afectada. La manipulaci\u00f3n del argumento rebootTime provoca un desbordamiento del b\u00fafer en la pila. Es posible ejecutar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-5863", "lastModified": "2025-06-09T19:02:45.383", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-09T06:15:25.870", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetRebootTimer-20a53a41781f80a6b9a8f6e5915cf256?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.311622" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.311622" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.591981" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac." } ], "id": "CVE-2023-31587", "lastModified": "2025-01-27T21:15:10.623", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-05-16T15:15:09.277", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/yanbushuang/CVE/blob/main/TendaAC5.md" }, { "source": "cve@mitre.org", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/download/detail-2740.html" }, { "source": "cve@mitre.org", "tags": [ "Patch" ], "url": "https://www.tenda.com.cn/product/AC5.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/yanbushuang/CVE/blob/main/TendaAC5.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/download/detail-2740.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch" ], "url": "https://www.tenda.com.cn/product/AC5.html" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md | Exploit, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md | Exploit, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function." } ], "id": "CVE-2023-38936", "lastModified": "2024-11-21T08:14:28.797", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.343", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Vendor Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Vendor Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/6/6.md | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/DrizzlingSun/Tenda/blob/main/AC5/6/6.md | Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetWirelessRepeat function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "id": "CVE-2023-25212", "lastModified": "2025-02-13T15:15:15.907", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-04-07T02:15:07.867", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/6/6.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/6/6.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md | Exploit, Third Party Advisory |
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg." } ], "id": "CVE-2023-41561", "lastModified": "2024-11-21T08:21:18.100", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:14.483", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2023-38935 (GCVE-0-2023-38935)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.522Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38935", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T20:06:05.688360Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T20:07:56.040Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38935", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T20:07:56.040Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41561 (GCVE-0-2023-41561)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.314Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "us_ac5v1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41561", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T18:56:47.271577Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:00:27.519Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:37:22.259883", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/formSetPPTPServer/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41561", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:00:27.519Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5863 (GCVE-0-2025-5863)
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.311622 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.311622 | signature, permissions-required | |
https://vuldb.com/?submit.591981 | third-party-advisory | |
https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetRebootTimer-20a53a41781f80a6b9a8f6e5915cf256?source=copy_link | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5863", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-10T14:43:54.154172Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-10T14:44:55.857Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC5", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.47" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC5 15.03.06.47 ausgemacht. Es geht dabei um die Funktion formSetRebootTimer der Datei /goform/SetRebootTimer. Durch die Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-09T05:31:07.242Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-311622 | Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.311622" }, { "name": "VDB-311622 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.311622" }, { "name": "Submit #591981 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.591981" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetRebootTimer-20a53a41781f80a6b9a8f6e5915cf256?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-08T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-08T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-08T15:32:27.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-5863", "datePublished": "2025-06-09T05:31:07.242Z", "dateReserved": "2025-06-08T13:27:21.149Z", "dateUpdated": "2025-06-10T14:44:55.857Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25213 (GCVE-0-2023-25213)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.251Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/5/5.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25213", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T21:11:50.335837Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-12T21:11:55.049Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the check_param_changed function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/5/5.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25213", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-12T21:11:55.049Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41556 (GCVE-0-2023-41556)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.265Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41556", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:38:05.672947Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:40:15.233Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:25:24.881206", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41556", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:40:15.233Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41562 (GCVE-0-2023-41562)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.185Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41562", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T18:52:45.696202Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T18:55:00.806Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:17:16.245089", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41562", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T18:55:00.806Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25210 (GCVE-0-2023-25210)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.212Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/1/1.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25210", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-13T14:43:08.008066Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-13T14:43:12.934Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetSysTime function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/1/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25210", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-13T14:43:12.934Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-3186 (GCVE-0-2021-3186)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T16:45:51.490Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.hackingarticles.in/exploiting-stored-cross-site-scripting-at-tenda-ac5-ac1200/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/161119/Tenda-AC5-AC1200-Wireless-Cross-Site-Scripting.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A Stored Cross-site scripting (XSS) vulnerability in /main.html Wifi Settings in Tenda AC5 AC1200 version V15.03.06.47_multi allows remote attackers to inject arbitrary web script or HTML via the Wifi Name parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-01-26T15:06:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.hackingarticles.in/exploiting-stored-cross-site-scripting-at-tenda-ac5-ac1200/" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/161119/Tenda-AC5-AC1200-Wireless-Cross-Site-Scripting.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-3186", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A Stored Cross-site scripting (XSS) vulnerability in /main.html Wifi Settings in Tenda AC5 AC1200 version V15.03.06.47_multi allows remote attackers to inject arbitrary web script or HTML via the Wifi Name parameter." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.hackingarticles.in/exploiting-stored-cross-site-scripting-at-tenda-ac5-ac1200/", "refsource": "MISC", "url": "https://www.hackingarticles.in/exploiting-stored-cross-site-scripting-at-tenda-ac5-ac1200/" }, { "name": "http://packetstormsecurity.com/files/161119/Tenda-AC5-AC1200-Wireless-Cross-Site-Scripting.html", "refsource": "MISC", "url": "http://packetstormsecurity.com/files/161119/Tenda-AC5-AC1200-Wireless-Cross-Site-Scripting.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-3186", "datePublished": "2021-01-24T19:35:34", "dateReserved": "2021-01-21T00:00:00", "dateUpdated": "2024-08-03T16:45:51.490Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37717 (GCVE-0-2023-37717)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:27.232Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0BR_V1.2.0.20(408)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.2.0.19_EN" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37717", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T15:36:28.731124Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:39:40.848Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37717", "datePublished": "2023-07-14T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-10-30T15:39:40.848Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25219 (GCVE-0-2023-25219)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.261Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/11/11.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25219", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T20:43:15.379906Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-12T20:43:22.111Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/11/11.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25219", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-12T20:43:22.111Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41559 (GCVE-0-2023-41559)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.261Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41559", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:26:04.363328Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:28:01.330Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:19:49.860110", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41559", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:28:01.330Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25220 (GCVE-0-2023-25220)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.190Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/7/7.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25220", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T20:36:21.148696Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-12T20:36:24.949Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the add_white_node function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/7/7.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25220", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-12T20:36:24.949Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41557 (GCVE-0-2023-41557)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.298Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41557", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:35:12.448972Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:36:24.229Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:23:38.395267", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41557", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:36:24.229Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-30368 (GCVE-0-2023-30368)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:21:44.817Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/2205794866/Tenda/blob/main/AC5/1.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-30368", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T20:58:00.415211Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T20:58:06.750Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 V15.03.06.28 is vulnerable to Buffer Overflow via the initWebs function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-24T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/2205794866/Tenda/blob/main/AC5/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-30368", "datePublished": "2023-04-24T00:00:00.000Z", "dateReserved": "2023-04-07T00:00:00.000Z", "dateUpdated": "2025-02-04T20:58:06.750Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-44971 (GCVE-0-2021-44971)
Vulnerability from cvelistv5
- n/a
▼ | URL | Tags |
---|---|---|
http://tenda.com | x_refsource_MISC | |
http://ac15v10.com | x_refsource_MISC | |
https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:32:13.606Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://tenda.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://ac15v10.com" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-28T18:17:04", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://tenda.com" }, { "tags": [ "x_refsource_MISC" ], "url": "http://ac15v10.com" }, { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-44971", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://tenda.com", "refsource": "MISC", "url": "http://tenda.com" }, { "name": "http://ac15v10.com", "refsource": "MISC", "url": "http://ac15v10.com" }, { "name": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md", "refsource": "MISC", "url": "https://github.com/21Gun5/my_cve/blob/main/tenda/bypass_auth.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-44971", "datePublished": "2022-01-28T18:17:04", "dateReserved": "2021-12-13T00:00:00", "dateUpdated": "2024-08-04T04:32:13.606Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41553 (GCVE-0-2023-41553)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.339Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41553", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:45:49.593482Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:47:38.332Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:31:36.490197", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetRouteStatic/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41553", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:47:38.332Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38930 (GCVE-0-2023-38930)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.646Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0,V15.03.06.44" }, { "status": "affected", "version": "F1203 V2.0.1.6," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0,V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0,V15.03.06.42_multi" }, { "status": "affected", "version": "FH1205 V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38930", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T19:31:04.398117Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T19:35:44.164Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38930", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T19:35:44.164Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25212 (GCVE-0-2023-25212)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.120Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/6/6.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25212", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-13T14:40:15.480910Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-13T14:40:23.359Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetWirelessRepeat function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/6/6.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25212", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-13T14:40:23.359Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37716 (GCVE-0-2023-37716)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:26.317Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0BR_V1.2.0.20(408)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.2.0.19_EN" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v.1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v3.0" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37716", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T15:41:48.422746Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:44:13.700Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37716", "datePublished": "2023-07-14T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-10-30T15:44:13.700Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38936 (GCVE-0-2023-38936)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.689Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38936", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T20:02:03.283677Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T20:05:36.911Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38936", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T20:05:36.911Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25216 (GCVE-0-2023-25216)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.270Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/9/9.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25216", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T21:00:11.688128Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-12T21:00:24.904Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/9/9.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25216", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-12T21:00:24.904Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38937 (GCVE-0-2023-38937)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.643Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38937", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T14:37:17.298133Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T14:40:31.909Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38937", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T14:40:31.909Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38933 (GCVE-0-2023-38933)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.649Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38933", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T13:48:33.206945Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T13:51:46.931Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38933", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T13:51:46.931Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25214 (GCVE-0-2023-25214)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.204Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/4/4.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25214", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T21:06:32.989637Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-12T21:06:37.880Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/4/4.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25214", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-12T21:06:37.880Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25218 (GCVE-0-2023-25218)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.254Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.dlink.com/en/security-bulletin/" }, { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/8/8.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25218", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T20:51:47.395795Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-12T20:51:51.317Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.dlink.com/en/security-bulletin/" }, { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/8/8.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25218", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-12T20:51:51.317Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25215 (GCVE-0-2023-25215)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.300Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/3/3.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25215", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T21:01:23.253466Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-12T21:01:26.906Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/3/3.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25215", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-12T21:01:26.906Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-6887 (GCVE-0-2025-6887)
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.314366 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.314366 | signature, permissions-required | |
https://vuldb.com/?submit.603788 | third-party-advisory | |
https://vuldb.com/?submit.603789 | third-party-advisory | |
https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_time-21d53a41781f8002bdb3fe8344d6fd8c?source=copy_link | related | |
https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_timeZone-21d53a41781f8021ae2fd2ac639f1b3f?source=copy_link | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-6887", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-30T16:10:08.094822Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-30T16:20:32.529Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC5", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.47" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC5 15.03.06.47 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um eine nicht n\u00e4her spezifizierte Funktion der Datei /goform/SetSysTimeCfg. Durch Manipulieren des Arguments time/timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-30T04:32:29.352Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-314366 | Tenda AC5 SetSysTimeCfg stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.314366" }, { "name": "VDB-314366 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.314366" }, { "name": "Submit #603788 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.603788" }, { "name": "Submit #603789 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow (Duplicate)", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.603789" }, { "tags": [ "related" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_time-21d53a41781f8002bdb3fe8344d6fd8c?source=copy_link" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_timeZone-21d53a41781f8021ae2fd2ac639f1b3f?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-28T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-28T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-28T17:03:52.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC5 SetSysTimeCfg stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-6887", "datePublished": "2025-06-30T04:32:29.352Z", "dateReserved": "2025-06-28T14:58:40.648Z", "dateUpdated": "2025-06-30T16:20:32.529Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41563 (GCVE-0-2023-41563)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.265Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v3.0_v15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "us_ac5v1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41563", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T18:47:11.788881Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T18:50:56.783Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:38:53.547135", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/GetParentControlInfo/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41563", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T18:50:56.783Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-6886 (GCVE-0-2025-6886)
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.314365 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.314365 | signature, permissions-required | |
https://vuldb.com/?submit.603774 | third-party-advisory | |
https://vuldb.com/?submit.603775 | third-party-advisory | |
https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedEndTime-21d53a41781f80fb8a90f08898e8d404?source=copy_link | related | |
https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedStartTime-21d53a41781f803f97eeddd9828c5c84?source=copy_link | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-6886", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-30T16:27:27.047025Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-30T16:27:50.848Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC5", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.47" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_ (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda AC5 15.03.06.47 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um eine nicht n\u00e4her bekannte Funktion der Datei /goform/openSchedWifi. Durch das Manipulieren des Arguments schedStartTime/schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-30T04:02:23.680Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-314365 | Tenda AC5 openSchedWifi stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.314365" }, { "name": "VDB-314365 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.314365" }, { "name": "Submit #603774 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.603774" }, { "name": "Submit #603775 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow (Duplicate)", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.603775" }, { "tags": [ "related" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedEndTime-21d53a41781f80fb8a90f08898e8d404?source=copy_link" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedStartTime-21d53a41781f803f97eeddd9828c5c84?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-28T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-28T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-28T17:03:41.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC5 openSchedWifi stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-6886", "datePublished": "2025-06-30T04:02:23.680Z", "dateReserved": "2025-06-28T14:58:38.446Z", "dateUpdated": "2025-06-30T16:27:50.848Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5794 (GCVE-0-2025-5794)
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.311348 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.311348 | signature, permissions-required | |
https://vuldb.com/?submit.591223 | third-party-advisory | |
https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0?source=copy_link | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5794", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-09T15:11:12.378126Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-09T15:11:15.451Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC5", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.47" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC5 15.03.06.47 entdeckt. Betroffen davon ist die Funktion formSetPPTPUserList der Datei /goform/setPptpUserList. Durch Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-06T18:31:07.897Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-311348 | Tenda AC5 setPptpUserList formSetPPTPUserList buffer overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.311348" }, { "name": "VDB-311348 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.311348" }, { "name": "Submit #591223 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.591223" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-06T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-06T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-06T10:34:36.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC5 setPptpUserList formSetPPTPUserList buffer overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-5794", "datePublished": "2025-06-06T18:31:07.897Z", "dateReserved": "2025-06-06T08:29:28.742Z", "dateUpdated": "2025-06-09T15:11:15.451Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25211 (GCVE-0-2023-25211)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:35.978Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/2/2.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25211", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-13T14:41:58.488011Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-13T14:42:12.372Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/2/2.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25211", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-13T14:42:12.372Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-31587 (GCVE-0-2023-31587)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:53:30.911Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.tenda.com.cn/product/AC5.html" }, { "tags": [ "x_transferred" ], "url": "https://www.tenda.com.cn/download/detail-2740.html" }, { "tags": [ "x_transferred" ], "url": "https://github.com/yanbushuang/CVE/blob/main/TendaAC5.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-31587", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-23T17:03:27.322016Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "description": "CWE-noinfo Not enough information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-27T21:07:10.517Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-05-16T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.tenda.com.cn/product/AC5.html" }, { "url": "https://www.tenda.com.cn/download/detail-2740.html" }, { "url": "https://github.com/yanbushuang/CVE/blob/main/TendaAC5.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-31587", "datePublished": "2023-05-16T00:00:00.000Z", "dateReserved": "2023-04-29T00:00:00.000Z", "dateUpdated": "2025-01-27T21:07:10.517Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5795 (GCVE-0-2025-5795)
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.311349 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.311349 | signature, permissions-required | |
https://vuldb.com/?submit.591224 | third-party-advisory | |
https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530?source=copy_link | exploit | |
https://www.tenda.com.cn/ | product |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5795", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-09T15:10:41.055915Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-09T15:10:44.767Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC5", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0" }, { "status": "affected", "version": "15.03.06.47" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_backup (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC5 1.0/15.03.06.47 gefunden. Betroffen hiervon ist die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip. Mittels dem Manipulieren des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-06T18:31:11.459Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-311349 | Tenda AC5 AdvSetLanip fromadvsetlanip buffer overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.311349" }, { "name": "VDB-311349 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.311349" }, { "name": "Submit #591224 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.591224" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-06T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-06T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-06T10:34:38.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC5 AdvSetLanip fromadvsetlanip buffer overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-5795", "datePublished": "2025-06-06T18:31:11.459Z", "dateReserved": "2025-06-06T08:29:30.876Z", "dateUpdated": "2025-06-09T15:10:44.767Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25217 (GCVE-0-2023-25217)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.074Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/10/10.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25217", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-12T20:58:19.774003Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-12T20:58:25.449Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formWifiBasicSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-07T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DrizzlingSun/Tenda/blob/main/AC5/10/10.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25217", "datePublished": "2023-04-07T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-02-12T20:58:25.449Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38931 (GCVE-0-2023-38931)
Vulnerability from cvelistv5
- n/a
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.242Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38931", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T13:52:20.173225Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T13:55:25.786Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38931", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T13:55:25.786Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202308-3695
Vulnerability from variot
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of AC7 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3695", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011082" }, { "db": "NVD", "id": "CVE-2023-41557" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-41557" } ] }, "cve": "CVE-2023-41557", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-41557", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-41557", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-41557", "trust": 1.8, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011082" }, { "db": "NVD", "id": "CVE-2023-41557" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of AC7 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-41557" }, { "db": "JVNDB", "id": "JVNDB-2023-011082" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-41557", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-011082", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011082" }, { "db": "NVD", "id": "CVE-2023-41557" } ] }, "id": "VAR-202308-3695", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-13T22:37:43.002000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011082" }, { "db": "NVD", "id": "CVE-2023-41557" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromaddressnat/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41557" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011082" }, { "db": "NVD", "id": "CVE-2023-41557" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-011082" }, { "db": "NVD", "id": "CVE-2023-41557" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-011082" }, { "date": "2023-08-30T13:15:00", "db": "NVD", "id": "CVE-2023-41557" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-12T05:53:00", "db": "JVNDB", "id": "JVNDB-2023-011082" }, { "date": "2023-08-31T18:40:00", "db": "NVD", "id": "CVE-2023-41557" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC7\u00a0 firmware and \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011082" } ], "trust": 0.8 } }
var-202308-3957
Vulnerability from variot
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3957", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011501" }, { "db": "NVD", "id": "CVE-2023-41561" } ] }, "cve": "CVE-2023-41561", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-41561", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-41561", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-41561", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-41561", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011501" }, { "db": "NVD", "id": "CVE-2023-41561" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-41561" }, { "db": "JVNDB", "id": "JVNDB-2023-011501" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-41561", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-011501", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011501" }, { "db": "NVD", "id": "CVE-2023-41561" } ] }, "id": "VAR-202308-3957", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43844455 }, "last_update_date": "2024-08-14T15:00:06.542000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011501" }, { "db": "NVD", "id": "CVE-2023-41561" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/peris-navince/founded-0-days/blob/main/formsetpptpserver/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41561" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011501" }, { "db": "NVD", "id": "CVE-2023-41561" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-011501" }, { "db": "NVD", "id": "CVE-2023-41561" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-011501" }, { "date": "2023-08-30T13:15:14.483000", "db": "NVD", "id": "CVE-2023-41561" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T07:04:00", "db": "JVNDB", "id": "JVNDB-2023-011501" }, { "date": "2023-09-01T20:16:09.883000", "db": "NVD", "id": "CVE-2023-41561" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 firmware and \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011501" } ], "trust": 0.8 } }
var-202308-4017
Vulnerability from variot
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4017", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "5.03.06.42_multi" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011083" }, { "db": "NVD", "id": "CVE-2023-41556" } ] }, "cve": "CVE-2023-41556", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-41556", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-41556", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-41556", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-41556", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011083" }, { "db": "NVD", "id": "CVE-2023-41556" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-41556" }, { "db": "JVNDB", "id": "JVNDB-2023-011083" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-41556", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-011083", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011083" }, { "db": "NVD", "id": "CVE-2023-41556" } ] }, "id": "VAR-202308-4017", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43844455 }, "last_update_date": "2024-08-14T15:05:27.688000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011083" }, { "db": "NVD", "id": "CVE-2023-41556" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromsetipmacbind/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41556" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011083" }, { "db": "NVD", "id": "CVE-2023-41556" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-011083" }, { "db": "NVD", "id": "CVE-2023-41556" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-011083" }, { "date": "2023-08-30T13:15:13.697000", "db": "NVD", "id": "CVE-2023-41556" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-12T05:53:00", "db": "JVNDB", "id": "JVNDB-2023-011083" }, { "date": "2023-08-31T18:40:18.453000", "db": "NVD", "id": "CVE-2023-41556" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011083" } ], "trust": 0.8 } }
var-202308-3781
Vulnerability from variot
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3781", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "fh1205", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.0.7\\(775\\)" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "f1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "fh1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1205", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "f1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "cve": "CVE-2023-38933", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38933", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38933", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38933", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38933", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38933" }, { "db": "JVNDB", "id": "JVNDB-2023-021661" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38933", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021661", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "id": "VAR-202308-3781", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3288697725 }, "last_update_date": "2024-08-14T13:19:52.824000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetclientstate/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38933" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "db": "NVD", "id": "CVE-2023-38933" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "date": "2023-08-07T19:15:11.133000", "db": "NVD", "id": "CVE-2023-38933" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021661" }, { "date": "2023-08-10T17:17:41.653000", "db": "NVD", "id": "CVE-2023-38933" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021661" } ], "trust": 0.8 } }
var-202304-0459
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0459", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "db": "NVD", "id": "CVE-2023-25219" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-25219" } ] }, "cve": "CVE-2023-25219", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25219", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-25219", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-496", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "db": "NVD", "id": "CVE-2023-25219" }, { "db": "CNNVD", "id": "CNNVD-202304-496" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25219" }, { "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "db": "VULMON", "id": "CVE-2023-25219" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25219", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006856", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-496", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25219", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25219" }, { "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "db": "NVD", "id": "CVE-2023-25219" }, { "db": "CNNVD", "id": "CNNVD-202304-496" } ] }, "id": "VAR-202304-0459", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T13:11:28.182000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "db": "NVD", "id": "CVE-2023-25219" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/11/11.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25219" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25219/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25219" }, { "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "db": "NVD", "id": "CVE-2023-25219" }, { "db": "CNNVD", "id": "CNNVD-202304-496" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-25219" }, { "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "db": "NVD", "id": "CVE-2023-25219" }, { "db": "CNNVD", "id": "CNNVD-202304-496" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25219" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "date": "2023-04-07T02:15:08.140000", "db": "NVD", "id": "CVE-2023-25219" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-496" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25219" }, { "date": "2023-11-16T07:05:00", "db": "JVNDB", "id": "JVNDB-2023-006856" }, { "date": "2023-04-13T17:45:10.830000", "db": "NVD", "id": "CVE-2023-25219" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-496" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-496" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006856" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-496" } ], "trust": 0.6 } }
var-202308-3852
Vulnerability from variot
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. AC7 firmware, f1203 firmware, fh1205 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3852", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "fh1205", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.0.7\\(775\\)" }, { "model": "f1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "f1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1205", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021095" }, { "db": "NVD", "id": "CVE-2023-38930" } ] }, "cve": "CVE-2023-38930", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38930", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38930", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38930", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38930", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021095" }, { "db": "NVD", "id": "CVE-2023-38930" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. AC7 firmware, f1203 firmware, fh1205 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38930" }, { "db": "JVNDB", "id": "JVNDB-2023-021095" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38930", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021095", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021095" }, { "db": "NVD", "id": "CVE-2023-38930" } ] }, "id": "VAR-202308-3852", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.29616356499999996 }, "last_update_date": "2024-08-14T15:00:06.598000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021095" }, { "db": "NVD", "id": "CVE-2023-38930" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/addwifimacfilter/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38930" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021095" }, { "db": "NVD", "id": "CVE-2023-38930" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021095" }, { "db": "NVD", "id": "CVE-2023-38930" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-18T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021095" }, { "date": "2023-08-07T19:15:10.907000", "db": "NVD", "id": "CVE-2023-38930" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-18T06:42:00", "db": "JVNDB", "id": "JVNDB-2023-021095" }, { "date": "2023-08-09T18:05:36.363000", "db": "NVD", "id": "CVE-2023-38930" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021095" } ], "trust": 0.8 } }
var-202304-0527
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0527", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5 us ac5v1.0rtl v15.03.06.28", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57679" }, { "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "db": "NVD", "id": "CVE-2023-25215" } ] }, "cve": "CVE-2023-25215", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-57679", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-25215", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25215", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-25215", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-25215", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2023-57679", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202304-497", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57679" }, { "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "db": "CNNVD", "id": "CNNVD-202304-497" }, { "db": "NVD", "id": "CVE-2023-25215" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25215" }, { "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "db": "CNVD", "id": "CNVD-2023-57679" }, { "db": "VULMON", "id": "CVE-2023-25215" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25215", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2023-006860", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-57679", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202304-497", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25215", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57679" }, { "db": "VULMON", "id": "CVE-2023-25215" }, { "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "db": "CNNVD", "id": "CNNVD-202304-497" }, { "db": "NVD", "id": "CVE-2023-25215" } ] }, "id": "VAR-202304-0527", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-57679" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57679" } ] }, "last_update_date": "2024-08-14T15:41:52.201000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "db": "NVD", "id": "CVE-2023-25215" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/3/3.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25215" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25215/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57679" }, { "db": "VULMON", "id": "CVE-2023-25215" }, { "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "db": "CNNVD", "id": "CNNVD-202304-497" }, { "db": "NVD", "id": "CVE-2023-25215" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-57679" }, { "db": "VULMON", "id": "CVE-2023-25215" }, { "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "db": "CNNVD", "id": "CNNVD-202304-497" }, { "db": "NVD", "id": "CVE-2023-25215" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-19T00:00:00", "db": "CNVD", "id": "CNVD-2023-57679" }, { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25215" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-497" }, { "date": "2023-04-07T02:15:07.980000", "db": "NVD", "id": "CVE-2023-25215" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-20T00:00:00", "db": "CNVD", "id": "CNVD-2023-57679" }, { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25215" }, { "date": "2023-11-16T07:08:00", "db": "JVNDB", "id": "JVNDB-2023-006860" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-497" }, { "date": "2023-04-13T17:44:35.293000", "db": "NVD", "id": "CVE-2023-25215" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-497" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006860" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-497" } ], "trust": 0.6 } }
var-202308-3714
Vulnerability from variot
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3714", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "fh1205", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.0.7\\(775\\)" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "f1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "fh1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1205", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "f1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "cve": "CVE-2023-38936", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38936", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38936", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38936", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38936", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38936" }, { "db": "JVNDB", "id": "JVNDB-2023-021659" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38936", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021659", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "id": "VAR-202308-3714", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3288697725 }, "last_update_date": "2024-08-14T15:36:47.021000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetspeedwan/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38936" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "db": "NVD", "id": "CVE-2023-38936" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "date": "2023-08-07T19:15:11.343000", "db": "NVD", "id": "CVE-2023-38936" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021659" }, { "date": "2023-08-10T18:20:51.897000", "db": "NVD", "id": "CVE-2023-38936" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021659" } ], "trust": 0.8 } }
var-202305-1572
Vulnerability from variot
Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. Shenzhen Tenda Technology Co.,Ltd. of AC5 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker could exploit this vulnerability to cause arbitrary code execution
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202305-1572", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v15.03.06.28" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40600" }, { "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "db": "NVD", "id": "CVE-2023-31587" } ] }, "cve": "CVE-2023-31587", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-40600", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-31587", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-31587", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-31587", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-31587", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2023-40600", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202305-1519", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40600" }, { "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "db": "CNNVD", "id": "CNNVD-202305-1519" }, { "db": "NVD", "id": "CVE-2023-31587" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. Shenzhen Tenda Technology Co.,Ltd. of AC5 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker could exploit this vulnerability to cause arbitrary code execution", "sources": [ { "db": "NVD", "id": "CVE-2023-31587" }, { "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "db": "CNVD", "id": "CNVD-2023-40600" }, { "db": "VULMON", "id": "CVE-2023-31587" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-31587", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2023-010288", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-40600", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202305-1519", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-31587", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40600" }, { "db": "VULMON", "id": "CVE-2023-31587" }, { "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "db": "CNNVD", "id": "CNNVD-202305-1519" }, { "db": "NVD", "id": "CVE-2023-31587" } ] }, "id": "VAR-202305-1572", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-40600" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40600" } ] }, "last_update_date": "2024-08-14T13:52:30.492000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "db": "NVD", "id": "CVE-2023-31587" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://www.tenda.com.cn/download/detail-2740.html" }, { "trust": 2.5, "url": "https://www.tenda.com.cn/product/ac5.html" }, { "trust": 2.5, "url": "https://github.com/yanbushuang/cve/blob/main/tendaac5.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-31587" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-31587/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-40600" }, { "db": "VULMON", "id": "CVE-2023-31587" }, { "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "db": "CNNVD", "id": "CNNVD-202305-1519" }, { "db": "NVD", "id": "CVE-2023-31587" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-40600" }, { "db": "VULMON", "id": "CVE-2023-31587" }, { "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "db": "CNNVD", "id": "CNNVD-202305-1519" }, { "db": "NVD", "id": "CVE-2023-31587" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-05-24T00:00:00", "db": "CNVD", "id": "CNVD-2023-40600" }, { "date": "2023-05-16T00:00:00", "db": "VULMON", "id": "CVE-2023-31587" }, { "date": "2023-12-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "date": "2023-05-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202305-1519" }, { "date": "2023-05-16T15:15:09.277000", "db": "NVD", "id": "CVE-2023-31587" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-05-24T00:00:00", "db": "CNVD", "id": "CNVD-2023-40600" }, { "date": "2023-05-16T00:00:00", "db": "VULMON", "id": "CVE-2023-31587" }, { "date": "2023-12-08T05:33:00", "db": "JVNDB", "id": "JVNDB-2023-010288" }, { "date": "2023-05-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202305-1519" }, { "date": "2023-05-22T17:20:22.587000", "db": "NVD", "id": "CVE-2023-31587" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202305-1519" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Firmware vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-010288" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202305-1519" } ], "trust": 0.6 } }
var-202304-0599
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0599", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5 us ac5v1.0rtl v15.03.06.28", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57680" }, { "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "db": "NVD", "id": "CVE-2023-25211" } ] }, "cve": "CVE-2023-25211", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-57680", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-25211", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25211", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-25211", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-25211", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2023-57680", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202304-499", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57680" }, { "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "db": "CNNVD", "id": "CNNVD-202304-499" }, { "db": "NVD", "id": "CVE-2023-25211" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25211" }, { "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "db": "CNVD", "id": "CNVD-2023-57680" }, { "db": "VULMON", "id": "CVE-2023-25211" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25211", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2023-006906", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-57680", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202304-499", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25211", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57680" }, { "db": "VULMON", "id": "CVE-2023-25211" }, { "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "db": "CNNVD", "id": "CNNVD-202304-499" }, { "db": "NVD", "id": "CVE-2023-25211" } ] }, "id": "VAR-202304-0599", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-57680" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57680" } ] }, "last_update_date": "2024-08-14T15:16:07.015000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "db": "NVD", "id": "CVE-2023-25211" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/2/2.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25211" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25211/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57680" }, { "db": "VULMON", "id": "CVE-2023-25211" }, { "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "db": "CNNVD", "id": "CNNVD-202304-499" }, { "db": "NVD", "id": "CVE-2023-25211" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-57680" }, { "db": "VULMON", "id": "CVE-2023-25211" }, { "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "db": "CNNVD", "id": "CNNVD-202304-499" }, { "db": "NVD", "id": "CVE-2023-25211" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-19T00:00:00", "db": "CNVD", "id": "CNVD-2023-57680" }, { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25211" }, { "date": "2023-11-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-499" }, { "date": "2023-04-07T02:15:07.827000", "db": "NVD", "id": "CVE-2023-25211" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-20T00:00:00", "db": "CNVD", "id": "CNVD-2023-57680" }, { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25211" }, { "date": "2023-11-17T00:47:00", "db": "JVNDB", "id": "JVNDB-2023-006906" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-499" }, { "date": "2023-04-13T17:43:49.710000", "db": "NVD", "id": "CVE-2023-25211" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-499" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006906" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-499" } ], "trust": 0.6 } }
var-202308-3841
Vulnerability from variot
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3841", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011498" }, { "db": "NVD", "id": "CVE-2023-41563" } ] }, "cve": "CVE-2023-41563", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-41563", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-41563", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-41563", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-41563", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011498" }, { "db": "NVD", "id": "CVE-2023-41563" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-41563" }, { "db": "JVNDB", "id": "JVNDB-2023-011498" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-41563", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-011498", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011498" }, { "db": "NVD", "id": "CVE-2023-41563" } ] }, "id": "VAR-202308-3841", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43844455 }, "last_update_date": "2024-08-14T14:48:56.348000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011498" }, { "db": "NVD", "id": "CVE-2023-41563" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/peris-navince/founded-0-days/blob/main/getparentcontrolinfo/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41563" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011498" }, { "db": "NVD", "id": "CVE-2023-41563" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-011498" }, { "db": "NVD", "id": "CVE-2023-41563" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-011498" }, { "date": "2023-08-30T13:15:15.043000", "db": "NVD", "id": "CVE-2023-41563" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T07:01:00", "db": "JVNDB", "id": "JVNDB-2023-011498" }, { "date": "2023-09-01T19:54:35.217000", "db": "NVD", "id": "CVE-2023-41563" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 firmware and \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011498" } ], "trust": 0.8 } }
var-202304-0458
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetSysTime function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0458", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "db": "NVD", "id": "CVE-2023-25210" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-25210" } ] }, "cve": "CVE-2023-25210", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25210", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-25210", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-500", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "db": "NVD", "id": "CVE-2023-25210" }, { "db": "CNNVD", "id": "CNNVD-202304-500" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetSysTime function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25210" }, { "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "db": "VULMON", "id": "CVE-2023-25210" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25210", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006907", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-500", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25210", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25210" }, { "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "db": "NVD", "id": "CVE-2023-25210" }, { "db": "CNNVD", "id": "CNNVD-202304-500" } ] }, "id": "VAR-202304-0458", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T14:03:23.236000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "db": "NVD", "id": "CVE-2023-25210" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/1/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25210" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25210/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25210" }, { "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "db": "NVD", "id": "CVE-2023-25210" }, { "db": "CNNVD", "id": "CNNVD-202304-500" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-25210" }, { "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "db": "NVD", "id": "CVE-2023-25210" }, { "db": "CNNVD", "id": "CNNVD-202304-500" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25210" }, { "date": "2023-11-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "date": "2023-04-07T02:15:07.793000", "db": "NVD", "id": "CVE-2023-25210" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-500" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25210" }, { "date": "2023-11-17T00:47:00", "db": "JVNDB", "id": "JVNDB-2023-006907" }, { "date": "2023-04-13T17:43:34.923000", "db": "NVD", "id": "CVE-2023-25210" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-500" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-500" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006907" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-500" } ], "trust": 0.6 } }
var-202304-0618
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the check_param_changed function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0618", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "db": "NVD", "id": "CVE-2023-25213" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-25213" } ] }, "cve": "CVE-2023-25213", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25213", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-25213", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-501", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "db": "NVD", "id": "CVE-2023-25213" }, { "db": "CNNVD", "id": "CNNVD-202304-501" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the check_param_changed function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25213" }, { "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "db": "VULMON", "id": "CVE-2023-25213" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25213", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006862", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-501", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25213", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25213" }, { "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "db": "NVD", "id": "CVE-2023-25213" }, { "db": "CNNVD", "id": "CNNVD-202304-501" } ] }, "id": "VAR-202304-0618", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T11:54:44.658000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "db": "NVD", "id": "CVE-2023-25213" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/5/5.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25213" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25213/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25213" }, { "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "db": "NVD", "id": "CVE-2023-25213" }, { "db": "CNNVD", "id": "CNNVD-202304-501" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-25213" }, { "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "db": "NVD", "id": "CVE-2023-25213" }, { "db": "CNNVD", "id": "CNNVD-202304-501" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25213" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "date": "2023-04-07T02:15:07.907000", "db": "NVD", "id": "CVE-2023-25213" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-501" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25213" }, { "date": "2023-11-16T07:09:00", "db": "JVNDB", "id": "JVNDB-2023-006862" }, { "date": "2023-04-13T17:44:09.427000", "db": "NVD", "id": "CVE-2023-25213" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-501" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-501" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006862" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-501" } ], "trust": 0.6 } }
var-202304-0584
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0584", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5 us ac5v1.0rtl v15.03.06.28", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57678" }, { "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "db": "NVD", "id": "CVE-2023-25214" } ] }, "cve": "CVE-2023-25214", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-57678", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-25214", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25214", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-25214", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-25214", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2023-57678", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202304-502", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57678" }, { "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "db": "CNNVD", "id": "CNNVD-202304-502" }, { "db": "NVD", "id": "CVE-2023-25214" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25214" }, { "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "db": "CNVD", "id": "CNVD-2023-57678" }, { "db": "VULMON", "id": "CVE-2023-25214" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25214", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2023-006861", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-57678", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202304-502", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25214", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57678" }, { "db": "VULMON", "id": "CVE-2023-25214" }, { "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "db": "CNNVD", "id": "CNNVD-202304-502" }, { "db": "NVD", "id": "CVE-2023-25214" } ] }, "id": "VAR-202304-0584", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-57678" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57678" } ] }, "last_update_date": "2024-08-14T15:00:24.420000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "db": "NVD", "id": "CVE-2023-25214" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/4/4.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25214" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25214/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-57678" }, { "db": "VULMON", "id": "CVE-2023-25214" }, { "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "db": "CNNVD", "id": "CNNVD-202304-502" }, { "db": "NVD", "id": "CVE-2023-25214" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-57678" }, { "db": "VULMON", "id": "CVE-2023-25214" }, { "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "db": "CNNVD", "id": "CNNVD-202304-502" }, { "db": "NVD", "id": "CVE-2023-25214" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-19T00:00:00", "db": "CNVD", "id": "CNVD-2023-57678" }, { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25214" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-502" }, { "date": "2023-04-07T02:15:07.940000", "db": "NVD", "id": "CVE-2023-25214" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-20T00:00:00", "db": "CNVD", "id": "CNVD-2023-57678" }, { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25214" }, { "date": "2023-11-16T07:08:00", "db": "JVNDB", "id": "JVNDB-2023-006861" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-502" }, { "date": "2023-04-13T17:44:21.567000", "db": "NVD", "id": "CVE-2023-25214" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-502" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006861" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-502" } ], "trust": 0.6 } }
var-202304-0585
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetWirelessRepeat function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0585", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "db": "NVD", "id": "CVE-2023-25212" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-25212" } ] }, "cve": "CVE-2023-25212", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25212", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-25212", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-498", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "db": "NVD", "id": "CVE-2023-25212" }, { "db": "CNNVD", "id": "CNNVD-202304-498" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetWirelessRepeat function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25212" }, { "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "db": "VULMON", "id": "CVE-2023-25212" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25212", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006863", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-498", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25212", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25212" }, { "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "db": "NVD", "id": "CVE-2023-25212" }, { "db": "CNNVD", "id": "CNNVD-202304-498" } ] }, "id": "VAR-202304-0585", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T12:54:26.360000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "db": "NVD", "id": "CVE-2023-25212" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/6/6.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25212" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25212/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25212" }, { "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "db": "NVD", "id": "CVE-2023-25212" }, { "db": "CNNVD", "id": "CNNVD-202304-498" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-25212" }, { "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "db": "NVD", "id": "CVE-2023-25212" }, { "db": "CNNVD", "id": "CNNVD-202304-498" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25212" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "date": "2023-04-07T02:15:07.867000", "db": "NVD", "id": "CVE-2023-25212" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-498" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25212" }, { "date": "2023-11-16T07:10:00", "db": "JVNDB", "id": "JVNDB-2023-006863" }, { "date": "2023-04-13T17:43:57.860000", "db": "NVD", "id": "CVE-2023-25212" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-498" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-498" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006863" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-498" } ], "trust": 0.6 } }
var-202308-4200
Vulnerability from variot
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4200", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "5.03.06.42_multi" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011115" }, { "db": "NVD", "id": "CVE-2023-41553" } ] }, "cve": "CVE-2023-41553", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-41553", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-41553", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-41553", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-41553", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011115" }, { "db": "NVD", "id": "CVE-2023-41553" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetStaticRouteCfg. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware and AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-41553" }, { "db": "JVNDB", "id": "JVNDB-2023-011115" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-41553", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-011115", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011115" }, { "db": "NVD", "id": "CVE-2023-41553" } ] }, "id": "VAR-202308-4200", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43844455 }, "last_update_date": "2024-08-14T15:20:57.244000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011115" }, { "db": "NVD", "id": "CVE-2023-41553" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromsetroutestatic/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41553" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011115" }, { "db": "NVD", "id": "CVE-2023-41553" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-011115" }, { "db": "NVD", "id": "CVE-2023-41553" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-011115" }, { "date": "2023-08-30T13:15:13.280000", "db": "NVD", "id": "CVE-2023-41553" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-12T06:21:00", "db": "JVNDB", "id": "JVNDB-2023-011115" }, { "date": "2023-08-31T18:40:45.207000", "db": "NVD", "id": "CVE-2023-41553" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC9\u00a0 firmware and \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011115" } ], "trust": 0.8 } }
var-202304-0528
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the add_white_node function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0528", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "db": "NVD", "id": "CVE-2023-25220" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-25220" } ] }, "cve": "CVE-2023-25220", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25220", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-25220", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-492", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "db": "NVD", "id": "CVE-2023-25220" }, { "db": "CNNVD", "id": "CNNVD-202304-492" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the add_white_node function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25220" }, { "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "db": "VULMON", "id": "CVE-2023-25220" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25220", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006855", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-492", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25220", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25220" }, { "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "db": "NVD", "id": "CVE-2023-25220" }, { "db": "CNNVD", "id": "CNNVD-202304-492" } ] }, "id": "VAR-202304-0528", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T13:36:22.523000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "db": "NVD", "id": "CVE-2023-25220" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://www.dlink.com/en/security-bulletin/" }, { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/7/7.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25220" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25220/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25220" }, { "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "db": "NVD", "id": "CVE-2023-25220" }, { "db": "CNNVD", "id": "CNNVD-202304-492" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-25220" }, { "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "db": "NVD", "id": "CVE-2023-25220" }, { "db": "CNNVD", "id": "CNNVD-202304-492" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25220" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "date": "2023-04-07T02:15:08.177000", "db": "NVD", "id": "CVE-2023-25220" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-492" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25220" }, { "date": "2023-11-16T07:04:00", "db": "JVNDB", "id": "JVNDB-2023-006855" }, { "date": "2023-04-13T17:45:17.310000", "db": "NVD", "id": "CVE-2023-25220" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-492" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-492" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006855" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-492" } ], "trust": 0.6 } }
var-202201-1106
Vulnerability from variot
Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE. AC15V1.0 and AC5V1.0 An improper comparison vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC15 is a wireless router from the Chinese company Tenda
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202201-1106", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac15", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.20_multi" }, { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.48_multi" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac15", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac15v1.0 15.03.05.20 multi", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null }, { "model": "ac15v1.0 15.03.06.48 multi", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-22299" }, { "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "db": "NVD", "id": "CVE-2021-44971" } ] }, "cve": "CVE-2021-44971", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "nvd@nist.gov", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-44971", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 1.8, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2022-22299", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-44971", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-44971", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2021-44971", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2021-44971", "trust": 0.8, "value": "Critical" }, { "author": "CNVD", "id": "CNVD-2022-22299", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202201-2607", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-22299" }, { "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "db": "CNNVD", "id": "CNNVD-202201-2607" }, { "db": "NVD", "id": "CVE-2021-44971" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE. AC15V1.0 and AC5V1.0 An improper comparison vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC15 is a wireless router from the Chinese company Tenda", "sources": [ { "db": "NVD", "id": "CVE-2021-44971" }, { "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "db": "CNVD", "id": "CNVD-2022-22299" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-44971", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-004279", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-22299", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202201-2607", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-22299" }, { "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "db": "CNNVD", "id": "CNNVD-202201-2607" }, { "db": "NVD", "id": "CVE-2021-44971" } ] }, "id": "VAR-202201-1106", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-22299" } ], "trust": 1.4021206866666667 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-22299" } ] }, "last_update_date": "2024-11-23T22:20:40.388000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page", "trust": 0.8, "url": "https://tenda.com/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004279" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-697", "trust": 1.0 }, { "problemtype": "Inappropriate comparison (CWE-697) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "db": "NVD", "id": "CVE-2021-44971" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/21gun5/my_cve/blob/main/tenda/bypass_auth.md" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-44971" }, { "trust": 1.6, "url": "http://ac15v10.com" }, { "trust": 1.6, "url": "http://tenda.com" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-22299" }, { "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "db": "CNNVD", "id": "CNNVD-202201-2607" }, { "db": "NVD", "id": "CVE-2021-44971" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-22299" }, { "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "db": "CNNVD", "id": "CNNVD-202201-2607" }, { "db": "NVD", "id": "CVE-2021-44971" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-03-24T00:00:00", "db": "CNVD", "id": "CNVD-2022-22299" }, { "date": "2023-04-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "date": "2022-01-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202201-2607" }, { "date": "2022-01-28T19:15:07.963000", "db": "NVD", "id": "CVE-2021-44971" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-03-24T00:00:00", "db": "CNVD", "id": "CNVD-2022-22299" }, { "date": "2023-04-04T05:01:00", "db": "JVNDB", "id": "JVNDB-2022-004279" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202201-2607" }, { "date": "2024-11-21T06:31:45.903000", "db": "NVD", "id": "CVE-2021-44971" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-2607" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "AC15V1.0\u00a0 and \u00a0AC5V1.0\u00a0 Improper Comparison Vulnerability in Firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-004279" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-2607" } ], "trust": 0.6 } }
var-202304-0504
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0504", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "db": "NVD", "id": "CVE-2023-25216" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-25216" } ] }, "cve": "CVE-2023-25216", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25216", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-25216", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-494", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "db": "NVD", "id": "CVE-2023-25216" }, { "db": "CNNVD", "id": "CNNVD-202304-494" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25216" }, { "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "db": "VULMON", "id": "CVE-2023-25216" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25216", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006859", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-494", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25216", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25216" }, { "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "db": "NVD", "id": "CVE-2023-25216" }, { "db": "CNNVD", "id": "CNNVD-202304-494" } ] }, "id": "VAR-202304-0504", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T13:00:11.971000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "db": "NVD", "id": "CVE-2023-25216" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/9/9.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25216" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25216/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25216" }, { "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "db": "NVD", "id": "CVE-2023-25216" }, { "db": "CNNVD", "id": "CNNVD-202304-494" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-25216" }, { "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "db": "NVD", "id": "CVE-2023-25216" }, { "db": "CNNVD", "id": "CNNVD-202304-494" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25216" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "date": "2023-04-07T02:15:08.017000", "db": "NVD", "id": "CVE-2023-25216" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-494" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25216" }, { "date": "2023-11-16T07:07:00", "db": "JVNDB", "id": "JVNDB-2023-006859" }, { "date": "2023-04-13T17:44:42.100000", "db": "NVD", "id": "CVE-2023-25216" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-494" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-494" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006859" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-494" } ], "trust": 0.6 } }
var-202308-4265
Vulnerability from variot
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4265", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011504" }, { "db": "NVD", "id": "CVE-2023-41559" } ] }, "cve": "CVE-2023-41559", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-41559", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-41559", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-41559", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-41559", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011504" }, { "db": "NVD", "id": "CVE-2023-41559" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-41559" }, { "db": "JVNDB", "id": "JVNDB-2023-011504" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-41559", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-011504", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011504" }, { "db": "NVD", "id": "CVE-2023-41559" } ] }, "id": "VAR-202308-4265", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43844455 }, "last_update_date": "2024-08-14T15:20:57.186000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011504" }, { "db": "NVD", "id": "CVE-2023-41559" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromnatstaticsetting/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41559" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011504" }, { "db": "NVD", "id": "CVE-2023-41559" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-011504" }, { "db": "NVD", "id": "CVE-2023-41559" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-011504" }, { "date": "2023-08-30T13:15:14.280000", "db": "NVD", "id": "CVE-2023-41559" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T07:09:00", "db": "JVNDB", "id": "JVNDB-2023-011504" }, { "date": "2023-09-01T19:10:58.247000", "db": "NVD", "id": "CVE-2023-41559" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011504" } ], "trust": 0.8 } }
var-202308-4145
Vulnerability from variot
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4145", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac8", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.34.06" }, { "model": "f1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "fh1203", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "2.0.1.6" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "fh1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "f1203", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac8", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "cve": "CVE-2023-38931", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38931", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38931", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38931", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38931", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38931" }, { "db": "JVNDB", "id": "JVNDB-2023-021662" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38931", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021662", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "id": "VAR-202308-4145", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.29234484666666666 }, "last_update_date": "2024-08-14T14:23:50.165000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/cloudv2_setaccount/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38931" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "db": "NVD", "id": "CVE-2023-38931" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "date": "2023-08-07T19:15:10.977000", "db": "NVD", "id": "CVE-2023-38931" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021662" }, { "date": "2023-08-10T17:17:05.110000", "db": "NVD", "id": "CVE-2023-38931" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021662" } ], "trust": 0.8 } }
var-202308-4213
Vulnerability from variot
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4213", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac8", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.34.06" }, { "model": "ac6", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac6", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac8", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "cve": "CVE-2023-38937", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38937", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38937", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38937", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38937", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38937" }, { "db": "JVNDB", "id": "JVNDB-2023-021658" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38937", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021658", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "id": "VAR-202308-4213", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3871988366666666 }, "last_update_date": "2024-08-14T15:26:26.130000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetvirtualser/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38937" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "db": "NVD", "id": "CVE-2023-38937" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "date": "2023-08-07T19:15:11.413000", "db": "NVD", "id": "CVE-2023-38937" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021658" }, { "date": "2023-08-10T18:22:01.703000", "db": "NVD", "id": "CVE-2023-38937" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021658" } ], "trust": 0.8 } }
var-202304-0768
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formWifiBasicSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0768", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "db": "NVD", "id": "CVE-2023-25217" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-25217" } ] }, "cve": "CVE-2023-25217", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25217", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-25217", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-495", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "db": "NVD", "id": "CVE-2023-25217" }, { "db": "CNNVD", "id": "CNNVD-202304-495" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formWifiBasicSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25217" }, { "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "db": "VULMON", "id": "CVE-2023-25217" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25217", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006858", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-495", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25217", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25217" }, { "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "db": "NVD", "id": "CVE-2023-25217" }, { "db": "CNNVD", "id": "CNNVD-202304-495" } ] }, "id": "VAR-202304-0768", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T12:41:13.898000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "db": "NVD", "id": "CVE-2023-25217" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/10/10.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25217" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25217/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25217" }, { "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "db": "NVD", "id": "CVE-2023-25217" }, { "db": "CNNVD", "id": "CNNVD-202304-495" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-25217" }, { "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "db": "NVD", "id": "CVE-2023-25217" }, { "db": "CNNVD", "id": "CNNVD-202304-495" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25217" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "date": "2023-04-07T02:15:08.053000", "db": "NVD", "id": "CVE-2023-25217" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-495" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25217" }, { "date": "2023-11-16T07:06:00", "db": "JVNDB", "id": "JVNDB-2023-006858" }, { "date": "2023-04-13T17:44:51.210000", "db": "NVD", "id": "CVE-2023-25217" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-495" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-495" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006858" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-495" } ], "trust": 0.6 } }
var-202307-1306
Vulnerability from variot
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1306", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "f1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0br" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "3.0" }, { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "f1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.2.0.20\\(408\\)" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "fh1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.2.0.19_en" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37716" } ] }, "cve": "CVE-2023-37716", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-37716", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-37716", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202307-1255", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "db": "NVD", "id": "CVE-2023-37716" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting", "sources": [ { "db": "NVD", "id": "CVE-2023-37716" }, { "db": "VULMON", "id": "CVE-2023-37716" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37716", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202307-1255", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-37716", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-37716" }, { "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "db": "NVD", "id": "CVE-2023-37716" } ] }, "id": "VAR-202307-1306", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5256526420000001 }, "last_update_date": "2024-08-14T14:09:54.108000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37716" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromnatstaticsetting/report.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-37716/" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37716" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-37716" }, { "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "db": "NVD", "id": "CVE-2023-37716" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-37716" }, { "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "db": "NVD", "id": "CVE-2023-37716" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-14T00:00:00", "db": "VULMON", "id": "CVE-2023-37716" }, { "date": "2023-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "date": "2023-07-14T00:15:09.430000", "db": "NVD", "id": "CVE-2023-37716" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-14T00:00:00", "db": "VULMON", "id": "CVE-2023-37716" }, { "date": "2023-07-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-1255" }, { "date": "2023-07-21T14:33:30.690000", "db": "NVD", "id": "CVE-2023-37716" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1255" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda F1202 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1255" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1255" } ], "trust": 0.6 } }
var-202304-0586
Vulnerability from variot
Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-0586", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "db": "NVD", "id": "CVE-2023-25218" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-25218" } ] }, "cve": "CVE-2023-25218", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-25218", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-25218", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-493", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "db": "NVD", "id": "CVE-2023-25218" }, { "db": "CNNVD", "id": "CNNVD-202304-493" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-25218" }, { "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "db": "VULMON", "id": "CVE-2023-25218" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-25218", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-006857", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-493", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-25218", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25218" }, { "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "db": "NVD", "id": "CVE-2023-25218" }, { "db": "CNNVD", "id": "CNNVD-202304-493" } ] }, "id": "VAR-202304-0586", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T13:16:47.151000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "db": "NVD", "id": "CVE-2023-25218" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://www.dlink.com/en/security-bulletin/" }, { "trust": 2.5, "url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/8/8.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-25218" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-25218/" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-25218" }, { "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "db": "NVD", "id": "CVE-2023-25218" }, { "db": "CNNVD", "id": "CNNVD-202304-493" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-25218" }, { "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "db": "NVD", "id": "CVE-2023-25218" }, { "db": "CNNVD", "id": "CNNVD-202304-493" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25218" }, { "date": "2023-11-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "date": "2023-04-07T02:15:08.100000", "db": "NVD", "id": "CVE-2023-25218" }, { "date": "2023-04-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-493" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-04-07T00:00:00", "db": "VULMON", "id": "CVE-2023-25218" }, { "date": "2023-11-16T07:06:00", "db": "JVNDB", "id": "JVNDB-2023-006857" }, { "date": "2023-04-13T17:45:02.777000", "db": "NVD", "id": "CVE-2023-25218" }, { "date": "2023-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-493" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-493" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-006857" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-493" } ], "trust": 0.6 } }
var-202307-1183
Vulnerability from variot
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202307-1183", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "f1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0br" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "3.0" }, { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "f1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.2.0.20\\(408\\)" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "fh1202", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.2.0.19_en" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0" } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37717" } ] }, "cve": "CVE-2023-37717", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-37717", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-37717", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202307-1259", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "db": "NVD", "id": "CVE-2023-37717" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient", "sources": [ { "db": "NVD", "id": "CVE-2023-37717" }, { "db": "VULMON", "id": "CVE-2023-37717" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37717", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202307-1259", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-37717", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-37717" }, { "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "db": "NVD", "id": "CVE-2023-37717" } ] }, "id": "VAR-202307-1183", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5256526420000001 }, "last_update_date": "2024-08-14T15:41:40.794000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Tenda F1202 Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247158" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37717" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromdhcplistclient/repot.md" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-37717/" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37717" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-37717" }, { "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "db": "NVD", "id": "CVE-2023-37717" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-37717" }, { "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "db": "NVD", "id": "CVE-2023-37717" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-14T00:00:00", "db": "VULMON", "id": "CVE-2023-37717" }, { "date": "2023-07-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "date": "2023-07-14T00:15:09.477000", "db": "NVD", "id": "CVE-2023-37717" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-07-14T00:00:00", "db": "VULMON", "id": "CVE-2023-37717" }, { "date": "2023-07-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202307-1259" }, { "date": "2023-07-21T14:31:56.167000", "db": "NVD", "id": "CVE-2023-37717" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda F1202 Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202307-1259" } ], "trust": 0.6 } }
var-202308-4027
Vulnerability from variot
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4027", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac8", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.34.06" }, { "model": "ac1206", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.23" }, { "model": "ac10", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.03.10.13" }, { "model": "ac1206", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac10", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac8", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "cve": "CVE-2023-38935", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-38935", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-38935", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-38935", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-38935", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-38935" }, { "db": "JVNDB", "id": "JVNDB-2023-021660" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-38935", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-021660", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "id": "VAR-202308-4027", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3871988366666666 }, "last_update_date": "2024-08-14T14:16:59.792000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetqosband/readme.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-38935" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "db": "NVD", "id": "CVE-2023-38935" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "date": "2023-08-07T19:15:11.277000", "db": "NVD", "id": "CVE-2023-38935" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-01-19T07:51:00", "db": "JVNDB", "id": "JVNDB-2023-021660" }, { "date": "2023-08-10T17:18:24.527000", "db": "NVD", "id": "CVE-2023-38935" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-021660" } ], "trust": 0.8 } }
var-202308-4199
Vulnerability from variot
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202308-4199", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.42_multi" }, { "model": "ac7", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.44" }, { "model": "ac7", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac9", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011500" }, { "db": "NVD", "id": "CVE-2023-41562" } ] }, "cve": "CVE-2023-41562", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "nvd@nist.gov", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2023-41562", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-41562", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "nvd@nist.gov", "id": "CVE-2023-41562", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "CVE-2023-41562", "trust": 0.8, "value": "Critical" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011500" }, { "db": "NVD", "id": "CVE-2023-41562" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet. Shenzhen Tenda Technology Co.,Ltd. of AC9 firmware, AC7 firmware, AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-41562" }, { "db": "JVNDB", "id": "JVNDB-2023-011500" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-41562", "trust": 2.6 }, { "db": "JVNDB", "id": "JVNDB-2023-011500", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011500" }, { "db": "NVD", "id": "CVE-2023-41562" } ] }, "id": "VAR-202308-4199", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.43844455 }, "last_update_date": "2024-08-14T14:36:40.968000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011500" }, { "db": "NVD", "id": "CVE-2023-41562" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/peris-navince/founded-0-days/blob/main/setsmartpowermanagement/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-41562" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011500" }, { "db": "NVD", "id": "CVE-2023-41562" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-011500" }, { "db": "NVD", "id": "CVE-2023-41562" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-011500" }, { "date": "2023-08-30T13:15:14.573000", "db": "NVD", "id": "CVE-2023-41562" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T07:03:00", "db": "JVNDB", "id": "JVNDB-2023-011500" }, { "date": "2023-09-01T20:04:12.327000", "db": "NVD", "id": "CVE-2023-41562" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-011500" } ], "trust": 0.8 } }
var-202304-2237
Vulnerability from variot
Tenda AC5 V15.03.06.28 is vulnerable to Buffer Overflow via the initWebs function. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202304-2237", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac5", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac5 firmware 15.03.06.28" }, { "model": "ac5", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac5", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-008844" }, { "db": "NVD", "id": "CVE-2023-30368" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-30368" } ] }, "cve": "CVE-2023-30368", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-30368", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-30368", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202304-1901", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-008844" }, { "db": "NVD", "id": "CVE-2023-30368" }, { "db": "CNNVD", "id": "CNNVD-202304-1901" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC5 V15.03.06.28 is vulnerable to Buffer Overflow via the initWebs function. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2023-30368" }, { "db": "JVNDB", "id": "JVNDB-2023-008844" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-30368", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-008844", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202304-1901", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-008844" }, { "db": "NVD", "id": "CVE-2023-30368" }, { "db": "CNNVD", "id": "CNNVD-202304-1901" } ] }, "id": "VAR-202304-2237", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.75 }, "last_update_date": "2023-12-18T12:33:49.402000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-008844" }, { "db": "NVD", "id": "CVE-2023-30368" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/2205794866/tenda/blob/main/ac5/1.md" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-30368" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-30368/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-008844" }, { "db": "NVD", "id": "CVE-2023-30368" }, { "db": "CNNVD", "id": "CNNVD-202304-1901" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2023-008844" }, { "db": "NVD", "id": "CVE-2023-30368" }, { "db": "CNNVD", "id": "CNNVD-202304-1901" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-008844" }, { "date": "2023-04-24T14:15:07.860000", "db": "NVD", "id": "CVE-2023-30368" }, { "date": "2023-04-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-1901" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-04T03:16:00", "db": "JVNDB", "id": "JVNDB-2023-008844" }, { "date": "2023-04-28T02:54:16.583000", "db": "NVD", "id": "CVE-2023-30368" }, { "date": "2023-05-04T00:00:00", "db": "CNNVD", "id": "CNNVD-202304-1901" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-1901" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-008844" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202304-1901" } ], "trust": 0.6 } }